Product Information

The product is the X-2 TM boiler, designed for natural gas usage only. It includes various components such as gas valves, burner orifices, pilot assembly, ignition cables, and machine screws.

  • Key No. | Description | Part Number [Quantity]
  • X-202 | Gas Valve (Natural Gas), Honeywell VR8204C3007 | 109620-01 [1]
  • X-203 | N/A | N/A
  • X-204 | Gas Valve (Natural Gas), 3A Honeywell VR8304P4496 | N/A
  • X-205 | Gas Valve (LP Gas), Honeywell VR8204C3015 | 109615-01 [1]
  • X-206 | Gas Valve (LP Gas), Honeywell VR8304P4314 | N/A
  • X-207 | N/A | 109622-01 [1] X-208 | N/A | 109621-01 [1]
  • X-209 | N/A | 109731-02 [1], 109731-03 [1], 109731-04 [1], 109731-05 [1], 109731-06 [1], 109731-07 [1], 109731-08 [1], 109731-09 [1]
    • Burner Orifices – Natural Gas #47 | 3C Burner Orifices – LP Gas 1.20mm | 109733-01 [1] (16 orifices), 109734-01 [1] (16 orifices)
    • Pilot Assembly – Natural Gas | 3E Pilot Assembly – LP Gas | 3F Main Burner | 108112-01 [1], 109630-01 [1], 109628-01 [3 burners per kit] 1/4 Pilot Tubing | 109611-01 [1]
    • Ground Wire Assembl y | 109623-01 [1]
    • Ignition Cable/Boot – Natural Gas Only | 3J
    • Ignition Cable Boot – Natural Gas Only | 3K Machine Screw, 10-32 x 1/4 with External Tooth Washer | 3L

Product Usage Instructions

  1. Make sure the boiler is installed by a qualified installer.
  2. Refer to the provided model number and serial number when seeking information and support.
  3. Retain the user manual for future reference.
  4. For any issues or support, contact a heating contractor.
  5. Read the instructions carefully before installing the boiler.
  6. Ensure proper installation, adjustment, alteration, service, and maintenance to prevent property damage, injury, or loss of life.

Models

  • X-202
  • X-203
  • X-204
  • X-205
  • X-206
  • X-207
  • X-208
  • X-209
  • Water Boiler
  • Cast Iron
  • Chimney Vent
  • Gas Fired

TO THE INSTALLER

  • Affix these instructions adjacent to boiler.
  • Provide model number and serial number when seeking information and support.

TO THE CONSUMER
Retain these instructions for future reference. Contact heating contractor for all issues and support.

WARNING
Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or loss of life. For assistance or additional information, consult a qualified installer, service agency or gas supplier. Read these instructions carefully before installing.

Service Parts (continued)Burnham-X-202-Gas-Fired-Water-
Boilers-

Key No. Description Part Number [Quantity]
X-202 X-203 X-204

3A

| Gas Valve (Natural Gas), Honeywell VR8204C3007| 109620-01 [1]| N/A
Gas Valve (Natural Gas), Honeywell VR8304P4496| N/A| 109622-01 [1]
Gas Valve (LP Gas), Honeywell VR8204C3015| 109615-01 [1]| N/A
Gas Valve (LP Gas), Honeywell VR8304P4314| N/A| 109621-01 [1]

3B

| ½” Gas Manifold| 109731-02 [1]| 109731-03 [1]| 109731-04 [1]| 109731-05 [1]| 109731-06 [1]| N/A
¾” Gas Manifold| N/A| 109731-07 [1]| 109731-08 [1]| 109731-09 [1]

3C

| Burner Orifices – Natural Gas #47| 109733-01 [1] (16 orifices)
Burner Orifices – LP Gas 1.20mm| 109734-01 [1] (16 orifices)
3D| Pilot Burner| 109629-01 [1]

3E

| Pilot Assembly – Natural Gas| 108112-01 [1]
Pilot Assembly – LP Gas| 109630-01 [1]
3F| Main Burner| 109628-01 [3 burners per kit]
3G| 1/4″ Pilot Tubing| 109611-01 [1]
3H| Ground Wire Assembly| 109623-01 [1]
3J| Ignition Cable/Boot – Natural Gas Only| Available with 3E
3K| Ignition Cable Boot – Natural Gas Only
3L| Machine Screw, 10-32 x 1/4″ with External Tooth Washer| Source Locally Natural Gas [2], LP Gas [1]

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Burnham User Manuals

Related Manuals