PENTAIR Intellibrite 5g White And Color Pool And Spa Lights User Guide
- June 3, 2024
- Pentair
Table of Contents
- **
- PENTAIR Intellibrite 5g White And Color Pool And Spa Lights
- IMPORTANT WARNING AND SAFETY INSTRUCTIONS
- IntelliBrite® 5G Pool and Spa Lights Overview
- INTELLIBRITE® 5G POOL AND SPA LIGHT FIXTURE INSTALLATION (NEW POOL
- INSTALLING THE INTELLIBRITE® 5G POOL AND SPA LIGHT FIXTURE (AFTER
- Troubleshooting
- INSTALLING THE INTELLIBRITE® POOL LIGHT ASSEMBLY WITH NEW GASKET (see
- Wide and Narrow Angle Lens Adjustment
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
**
**
PENTAIR Intellibrite 5g White And Color Pool And Spa Lights
Before Installing
luminaries read the following:
WARNING
Always install a new lens gasket (see part number in this User’s Guide on page
9 and 19), when ever reassembling the light. Failure to do so may permit water
to leak into the assembly which could cause; (a) an electrical hazard
resulting in death or serious injury to pool users, installer, or others due
to electrical shock, or (b) breakage of the lamp or lens, which likewise could
result in serious injury to pool user, installers, or bystanders, or in damage
to property.
FOR 12 VAC LUMINARIES: ALWAYS USE A SEPARATE STEP DOWN TRANSFORMER TO POWER
LUMINARIES. SEE DIAGRAM ON PAGE 7. Note: Connect all three wires to the
corresponding circuit wires in the Junction Box (black wire to power, white
wire to common, and green wire to ground).
12 VAC LUMINARIES SPECIFICATION: 12 VAC, 50/60 Hz REPLACE ANY CRACKED
PROTECTIVE SHIELD (CRACKED LENS) WITH NEW LENS AND GASKET.
CAUTION
THE INTELLIBRITE 5G LED POOL LIGHT AND SPA LIGHT CANNOT BE USED ON A DIMMER
CIRCUIT. USING A DIMMER SWITCH WILL RESULT IN PERMANENT DAMAGE TO THE LIGHT.
IMPORTANT WARNING AND SAFETY INSTRUCTIONS
DANGER
- SERIOUS BODILY INJURY OR DEATH CAN RESULT IF THIS LIGHT IS NOT INSTALLED AND USED CORRECTLY.
- INSTALLERS, POOL OPERATORS AND POOL OWNERS MUST READ THESE WARNINGS AND ALL INSTRUCTIONS BEFORE USING THE POOL AND/OR SPA LIGHT.
WARNING
Most states and local codes regulate the construction, installation, and
operation of public pools and spas, and the construction of residential pools
and spas. It is important to comply with these codes, many of which directly
regulate the installation and use of this product. Consult your local building
and health codes for more information.
IMPORTANT NOTICE – Attention Installer: This Installation and User’s
Guide (“Guide”) contains important information about the installation,
operation and safe use of this underwater pool and spa light. This Guide
should be given to the owner and/or operator of this equipment.
WARNING
Before installing this product, read and follow all warning notices and
instructions in this Guide. Failure to follow warnings and instructions can
result in severe injury, death, or property damage.
Call 800-831-7133 for additional free
copies of these instructions. Please refer to
www.pentairpool.com for more information related
to this products.
DANGER
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION:
THE INTELLIBRITE® POOL AND SPA LIGHT REQUIRE HIGH VOLTAGE WHICH CAN SHOCK,
BURN, OR CAUSE DEATH.
BEFORE WORKING ON POOL AND SPA LIGHTS always disconnect power to the pool
and/or spa lights at the circuit breaker from the light before servicing the
light. Failure to do so could result in death or serious injury to service
person, pool users or others due to electric shock.
This underwater light must be installed by a licensed or certified electrician
or a qualified pool professional in accordance with the current National
Electrical Code (NEC), NFPA 70 or the Canadian Electrical Code (CEC), CSA
C22.1. All applicable local installation codes and ordinances must also be
adhered to. Improper installation will create an electrical hazard which could
result in death or serious injury to pool users, installers or others due to
electrical shock, and may also cause damage to property. Always disconnect the
power to the pool light at the circuit breaker before servicing the light.
Failure to do so could result in death or serious injury to serviceman, pool
users or others due to electrical shock.
WARNING
Important Safety Information for Pentair Water Pool and Spa Niche and Light
Installation
- All Niche and Light installations must conform with all codes. If local codes mandate a cord seal, use Pentair Water Pool and Spa plastic niches (P/N 79206600 and P/N 79206700) and Cord Seal Kit (P/N 670044).
- Under no circumstances replace lights by splicing wire under water or behind niche.
WARNING
RISK OF ELECTRIC SHOCK AND INJURY. USE ONLY THE INSTALLATION METHOD SPECIFIED
BELOW.
Location of Luminaire Use| Pentair Water Pool and Spa Fountain Fixture* (P/N
560001 and P/N 560000)| Required Installation Method
---|---|---
Swimming Pool and Spa| Wet-Niche Swimming Pool (or Spa) Luminaire (Light)|
Fixture Housing (Forming Shell) ONLY. DO NOT USE Fountain Fixture Stand.
Fountain| Wet-Niche Submersible Luminaire (Light) swimming Pool (or Spa)
Luminair (Light)| Fixture Housing (Forming Shell) or Fountain Fixture Stand
Note:
Wet-niche luminaires complying with requirements for both uses may bare
both the Listed Wet-Niche Submersible Luminaires UL Mark. A luminaire not
bearing the corresponding UL Listing Mark is not considered by UL to have been
produced under UL’s Listing and Follow-Up Service for the associated usage
location.
CAUTION
The IntelliBrite® 5G Light fixture must only be used with Pentair Water
Pool and Spa fixture housings (niches). If the IntelliBrite light fixture is
installed into other niches, the installation will not carry U.L. approval and
will void all warranties.
NOTICE:
The external flexible cable or cord of this luminaire cannot be replaced; if
the cord is damaged, the luminaire shall be destroyed.
WARNING
For countries in compliance with International Electromechnical Commission
(IEC) regulatory standards: The light fixture must be installed by a licensed
or certified electrician or a qualified pool service person, in accordance with
IEC 364-7-702 and all applicable local codes and ordinance. Improper
installation will create an electrical hazard, which could result in death or
serious injury to pool user, installer or other due to electrical shock and
may also cause damage to the property.
WARNING
Salt is an inherently corrosive material. While the levels of salt required
for proper operation of an electronic chlorine generator are relatively low
when compared to sea water and other salt solutions, placing any amount of
salt in your pool increases the likelihood of corrosion or other deterioration
of pool equipment and any surfaces used in and around your pool. Metal parts
and certain natural and man-made surfaces are particularly susceptible to
corrosion and deterioration when used in and around salt water pools. Pentair
does not represent or otherwise guarantee that the proper use of an electronic
chlorine generator will prevent corrosion or other deterioration of pool
equipment and any surfaces used in and around your pool. Consult your
experienced pool professional, who should be able to advise you on the proper
material selection, installation techniques for those materials, and the
proper use, care and maintenance of those materials for your specific pool type
and location in order to minimize the corrosion and deterioration that is
inherent in and around salt water pools.
POOL AND SPA FIXED LUMINARIES: Follow these guidelines when installing,
replacing or repairing Pentair Aquatic Systems Pool and Spa fixed luminaries:
- REPLACE ANY CRACKED PROTECTIVE SHIELD (CRACKED LENS) WITH NEW LENS AND GASKET. FOR MORE INFORMATION SEE PAGE 11.
- FOR LIGHT OPERATION, ONLY USE A SAFETY ISOLATION TRANSFORMER.
CAUTION
Luminaires not suitable for direct mounting on normally flammable surfaces
(suitable ONLY for mounting on non-combustible surfaces. Fixed pool and spa
luminaries specification:
12 VAC 50/60 Hz – 120VAC ,50/60 Hz.
- Surface Mount
IntelliBrite® 5G Pool and Spa Lights Overview
This manual describes how to install the IntelliBrite 5G white and color pool light and the IntelliBrite 5G white and color spa light. The IntelliBrite 5G white light provides a brilliant white light for a spectacular effect in your pool and spa. The IntelliBrite 5G white light lens geometry (pool light only) provides a choice between two light beam shapes; wider coverage with less intensity, or narrower coverage with more intensity. The IntelliBrite 5G color light provides brilliant vivid multi-colors with spectacular effects for your pool and spa. Choose one of the seven pre-programmed color light shows or select one of the five fixed colors to create virtually endless range of dramatic underwater lighting effects for a spectacular effect in your pool and spa.
Operating Pool and Spa Lights Using a Wall Switch (12 VAC)
IntelliBrite 5G pool and spa lights can be manually controlled using a
standard wall-mount light switch. Multiple IntelliBrite lights can be
connected via a junction box to a single switch so that all lights can be
switched on and off together. IntelliBrite lights can also be automatically
controlled via Pentair IntelliTouch®, EasyTouch® and SunTouch® Control
Systems. Note: Multiple IntelliBrite 5G pool/spa lights can also be controlled
using the IntelliBrite Controller, for more information see page 2.
Using an External Transformer for Multiple IntelliBrite 12 VAC Lights
When using multiple IntelliBrite 12 VAC lights on a 300 Watt transformer, it
is recommended that no more than three IntelliBrite pool lights and one (1)
IntelliBrite Spa light be used. It is also recommended not to exceed 100 feet
of total cable run between the transformer and light. Note: For long cable
lengths, set transformer to 14 VAC
(see diagrams below). Powering on
IntelliBrite® 5G Color Lights
When the IntelliBrite light is powered on, a momentarily white light will
illuminate, followed by the previously selected color. Note: If power to the
light is off for more than five (5) seconds, the last color show mode or fixed
color that was saved will be displayed.
Selecting a light show mode or fixed color
Switch power on to the light. A white light will momentarily illuminate,
followed by the previously selected color. To select a color show mode (1-7)
or fixed color (8-12), turn the wall switch off/on a specific number of times.
Each number (1-12) shown below corresponds to the number of times to power-
cycle the switch to activate a color light show or fixed color. For details
about saving color effects while in “show” modes, see “Hold” and “Recall”
feature on page 4. Example: To select California Sunset Mode; turn the light
on, then turn off and on six times. During the off/on switching process, no
illumination will occur, SAm Mode: Cycles through white, magenta, blue and
green colors (emulates the Pentair SAm® color changing light).
Party Mode: Rapid color changing building energy and excitement.
Romance Mode: Slow color transitions creating a mesmerizing and calming
effect.
Caribbean Mode: Transitions between a variety of blues and greens.
American Mode: Patriotic red, white and blue transition. California Sunset Mode: Dramatic transitions of orange,
red and magenta tones.
Royal Mode: Richer, deeper color tones.
Blue: Fixed color.
Green: Fixed color.
Red: Fixed color.
White: Fixed color.
Magenta: Fixed color.
Hold: Save the current color effect during a color light show.
Recall: Activate the last saved color effect.
Saving a Color Mode or Fixed Color: When power is switched off to the
IntelliBrite color lights, the last color show mode or fixed color will be
saved. The next time the light is powered on, the previously saved color show
mode or fixed color will be displayed. For example, while in “Party Mode”
switch the light off. Wait more than 10 seconds, switch the light back on to
resume “Party Mode.”
WARNING
During the off/on switching process, before the selected color is displayed,
no illumination will occur for a brief second. This operating mode is normal
during the switching process. During this period the pool and spa will be dark
and precautions should be taken to avoid unforeseen accidents. Failure to
observe this warning may result in serious injury or death to pool and spa
users.
Using an IntelliBrite Color Light Controller
Using the IntelliBrite Controller (sold separately, P/N 600054), IntelliBrite
5G color pool/spa lights can all be synchronized so that individual or
multiple IntelliBrite lights all lights can be switched on and off together.
To select a color light show mode or fixed color mode, rotate the dial so that
it points to the desired selection.
Hold and Recall Feature: When IntelliBrite color lights are powered on,
the previously selected color will be displayed, unless the HOLD or RECALL
feature was previously enabled.
Hold button/LED: Press this button (LED on) to capture and save a color
effect while displaying one of the light show modes. When the button is
pressed, the LED will be on, indicating that the color effect is captured.
Recall Button/LED: Use this button (LED on) to activate the last saved
color effect. When the button is pressed, the LED will be on, indicating that
the color effect is being displayed.
Replacing the IntelliBrite® 5G Pool and Spa Light Assembly (in an existing
pool or spa)
DANGER
Risk of Electrical Shock or Electrocution!
This underwater light must be installed by a licensed or certified electrician
or a qualified pool professional in accordance with the National Electrical
Code and all applicable local codes and ordinances. Improper installation will
create an electrical hazard which could result in death or serious injury to
pool users, installers or others due to electrical shock, and may also cause
damage to property. Always disconnect the power to the pool light at the
circuit breaker before servicing the light. Failure to do so could result in
death or serious injury to serviceman, pool users or others due to electrical
shock.
Verify that the pool and spa meets the requirements of the current National
Electrical Code and all local codes and ordinances. A licensed or certified
electrician must install the electrical system to meet or exceed those
requirements before the underwater light is installed. Some of the
requirements of the National Electrical Code which the pool’s electrical
system must meet are as follows:
- The lighting circuit has a Ground Fault Circuit Interrupter (GFCI) for line voltage models, and has an appropriately rated circuit breaker.
- The Junction Box (or, for 12 volt models, the low voltage transformer) is located at least eight (8) inches (20.3 cm) above ground level and at least 48 inches (1.219 m) from the edge of the pool; see Figure 1 on page 7.
- The light fixture and all metal items within five (5) feet (1.524 m) of the pool are properly electrically bonded.
- The wet niche is properly installed so that the top edge of the underwater light’s lens is at least 18 inches below the surface of the water in the pool; see Figure 1 on page 7.
- The wet niche is properly electrically bonded and grounded via the No. 8 AWG ground connector located at the rear of the niche; see Figure 1 on page 7.
- To be certain that the pool’s electrical system meets all applicable requirements, the electrician should also consult the local building department. Note: Use only Pentair wet niches to insure proper bonding and grounding connections.
Replacing the IntelliBrite® 5G Pool and Spa Light Assembly
(After Electrical Requirements Are Met)
The following removal and installation instructions describe how to remove and
install the IntelliBrite pool and spa light assembly. Also use these
instructions after completing the following light replacement procedure:
- IntelliBrite Spa Light and Face Ring Gasket and Lens Removal and Installation instructions, on page 19.
WARNING
Failure to bring the pool or spa’s electrical system up to code requirements
before installing the underwater light will create an electrical hazard which
could result in death or serious injury to pool users, installers, or others
due to electrical shock, and may also cause damage to property.
-
WARNING! Switch off main electrical switch or circuit breaker, and the switch which operates the IntelliBrite underwater light.
-
To remove light fixture assembly from the pool. Remove the special bronze pilot screw at top of face ring. Remove the IntelliBrite light assembly from the niche and place it on the deck.
-
Cut the cord about 12 inches (30.5 cm) from the back of the light assembly.
-
Remove Junction Box cover, disconnect the light fixture wires, and pull the cord through the conduit. Tip: Before pulling the cord, tape the new cord to the existing cord, This might make it easier to feed the new cord through the conduit (see following step).
-
Feed the new light fixture cord through the conduit from the niche to the Junction Box. Note: Depending on the length of the conduit, special tools may be required to pull the cord through the conduit.
-
Leave at least four (4) feet of cord to coil around the light fixture; see Figure 1 on page 6. This four (4) feet (1.2192 m) of cord coiled around the light allows the light to be serviced after the pool is filled with water.
-
Cut the cord at the Junction Box, leaving at least size (6) inches of cord to make connections.
-
Strip six (6) inches (15.2 cm) of the outer cord jacket from the cord to expose the three insulated conductors. Be careful not to damage the insulation on the three (3) inner conductors). Strip a 1/2” of insulation
-
Connect the three light wires (or two wires) to the corresponding light circuit wires in the Junction Box. For three wires; connect the black wire to power, white wire to common, and the green wire to ground.
-
For two wires connect the corresponding circuit wires (match the wire colors) in the Junction Box. Secure the Junction Box cover.
-
Install the IntelliBrite® light assembly into the pool niche. Be sure to insert the TAB on the lower part of the face ring into the niche SLOT (located on the lower part of the niche). This is important to secure the lower part of the light assembly onto the niche before tightening the pilot screw.
-
Carefully tighten the special bronze pilot screw to secure the upper part of the light assembly onto the niche.
WARNING
Use only the special pilot screw provided with this underwater light. This screw mounts and electrically grounds the housing securely to the mounting ring and wet niche. Failure to use the screw provided could create an electrical hazard which could result in death or serious injury to pool users, installers or others due to electrical shock. -
Final check for proper IntelliBrite light operation: Switch on the main switch or circuit breaker to the system, and the switch that operates the IntelliBrite underwater light itself. The light should illuminate when power is applied. If not recheck the installation steps starting with Step 1 (page 4).
INTELLIBRITE® 5G POOL AND SPA LIGHT FIXTURE INSTALLATION (NEW POOL
CONSTRUCTION)
The following describes how to install the IntelliBrite® Pool Light fixture and
the IntelliBrite Spa Light fixture. Read page 4 before starting the
installation procedure.
BEFORE STARTING: The following steps 1-7 (page 7-8) describe the tasks
that must be completed by the electrician before the IntelliBrite light fixture
is installed. See Figure 1 diagram on page 7.
WARNING
Be sure that the pool or spa meets the requirements of the current National
Electrical Code (N.E.C.) Article 680-22 and all local codes and ordinances. A
licensed or certified electrician must install the electrical system to meet or
exceed those requirements before the underwater light is installed. Some of
the requirements of the National Electrical Code which the pool’s electrical
system must meet are as follows:
- The lighting circuit has a Ground Fault Circuit Interrupter (GFCI) for line voltage models, and has an appropriately rated circuit breaker.
- The Junction Box (or, for 12 volt models, the low voltage transformer) is located at least eight (8) inches (20.3 cm) above ground level and at least 48 inches (1.219 m) from the edge of the pool; see Figure 1 on page 7.
- The light fixture and all metal items within five (5) feet (1.524 m) of the pool are properly electrically bonded.
- The wet niche is properly installed so that the top edge of the underwater light’s lens is at least 18 inches below the surface of the water in the pool; see Figure 1 on page 7.
- The wet niche is properly electrically bonded and grounded via the No. 8 AWG ground connector located at the rear of the niche; see Figure 1 on page 7.
Note:
To be certain that the pool or spa electrical system meets all applicable
requirements, the electrician should also consult the local building
department.
- Use only Pentair wet niches to insure proper bonding and grounding connections.
INSTALLING THE INTELLIBRITE® 5G POOL AND SPA LIGHT FIXTURE (AFTER
ELECTRICAL REQUIREMENTS ARE MET)
To install the IntelliBrite® Pool Light and Spa Light fixture:
-
Route light cable through conduit to Junction Box, leaving at least four (4) feet of cable at the light fixture to coil around the light (this allows the light to be serviced after the pool is filled with water). See Figure 1 below.
-
Cut the cable at the Junction Box, leaving at least six (6) inches (2.4 cm) of cord to make connections.
-
Strip back six (6) inches (2.4 cm) of the outer cord jacket to expose the three insulated conductors (be careful not to damage the insulation on the three
(3) inner conductors). Strip a 1/2” of insulation off the three conductors. Be careful not to damage the copper conductor. -
Connect all three (3) conductors to the corresponding circuit wires in the Junction Box and secure the Junction Box cover in place.
FOR LIGHT OPERATION, ONLY USE A SAFETY ISOLATION TRANSFORMER.
Note: Connect three wires (or two wires) to the corresponding circuit wires in the Junction Box. For three wires connect: Black wire to power, white wire to common, and green wire to ground.Note FOR VAC ILLUMINARIES,ISOLATION TRANSFORMER IS INCLUDED IN LIGHT FIXTURE -
Install the IntelliBrite® Light assembly into the niche and tighten the special bronze pilot screw.
WARNING
Use only the special pilot screw provided with this underwater light. This screw mounts and electrically grounds the housing securely to the mounting ring and wet niche. Failure to use the screw provided could create an electrical hazard which could result in death or serious injury to pool users, installers or others due to electrical shock.- IntelliBrite 5G Pool Light
- IntelliBrite 5G Spa Light
-
Fill the pool until the underwater light is completely submerged in water before operating the light.
-
Final check for proper light operation: To check for proper operation, switch on the main switch or circuit breaker, and the switch that operates the IntelliBrite underwater light itself. The light should illuminate when power is applied. If not recheck the installation steps starting with Step 1 (page 7)
FOR INTELLIBRITE POOL AND SPA LIGHT REMOVAL AND INSTALLATION INSTRUCTIONS SEE:
- Replacing the IntelliBrite® 5G Pool and Spa Light Assembly instructions, on page 3.
- Replacing the IntelliBrite Spa Light Face Ring and Gasket or Gasket and Lens instructions, on page 19.
IntelliBrite® 5G Pool Light (12V) Fuse Harness Replacement
The following describes how to replace the IntelliBrite 5G Pool Light fuse
assembly (if applicable) and the light main circuit board for the IntelliBrite
5G pool light.
IMPORTANT
Before replacing the fuse assembly note the following:
Troubleshooting
REPLACING THE INTELLIBRITE POOL LIGHT CIRCUIT BOARD ASSEMBLY (IN AN
EXISTING POOL)
When replacing or reassembling the IntelliBrite Pool Circuit Board, the Gasket
(P/N 79101601) or Gasket and Lens (619864Z) MUST ALSO BE REPLACED – SEE PAGE
18 FOR PART NUMBERS
Removal and Installation of IntelliBrite 5G Light Circuit Board
D A N G E R !
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION
Always disconnect power to the pool light at the circuit breaker before
servicing the light. Failure to do so could result in death or serious injury
to installer, service person, pool users, or others due to electrical shock.
-
Turn off main electrical switch or circuit breaker, as well as the switch which operates the IntelliBrite light itself.
-
Before starting make sure that you have a new lens gasket (P/N 79101601) and a IntelliBrite 5G pool light circuit board assembly (P/N 619875Z – 300w, P/N 619916Z-400W, P/N 619917Z- 500w) ready to install (see page 11).
WARNING
Replace the light circuit board assembly with the same type and wattage. Failure to replace the light circuit board assembly with the same type will damage the light assembly and may cause an electrical hazard resulting in death or serious injury to pool users, installers, or others due to electrical shock, and may also cause damage to property.
WARNING
Always install a new lens gasket (P/N 79101601) whenever disassembling the IntelliBrite light assembly. Failure to do so may permit water to leak into the assembly which could cause:- an electrical hazard resulting in death or serious injury to pool users, installers, or others due to electrical shock, or
- breakage of the lens, which likewise could result in serious injury to pool users, installers, or bystanders, or in damage to property.
-
REMOVING THE INTELLIBRITE 5G POOL LIGHT ASSEMBLY: Remove the pilot screw at top of face ring, remove the light assembly from the niche. Place the assembly on the deck. Note: It is not necessary to drain down the pool.
-
Unwind the cord from the base of the light housing.
IntelliBrite 5G Pool Light
WARNING
Be sure to keep the pilot screw from the IntelliBrite light. This screw mounts and electrically grounds the housing securely to the mounting ring and wet niche. Failure to use the screw provided could create an electrical hazard which could result in death or serious injury to pool users, installers or others due to electrical shock. -
Place a cloth on the ground to protect the lens. Turn the light over so the lens is resting on the cloth. Using a ¼” nut driver and a #3 Phillips screwdriver, remove the nut uni-tension wire clamp. Place the nut aside for reinstallation.
-
Remove the face ring and wire clamp from the light housing.
-
With the light resting on its base, carefully pry off the gasket to remove the lens. Set the lens aside for installation later. Discard the gasket.
Note: A NEW LENS GASKET
(P/N 79101601) MUST BE USED EACH TIME THE LIGHT IS REASSEMBLED. See page 18
for Replacement Kit part numbers.
Note: Note the current position of the lens at the pilot screw (12
o’clock) position, before removing it from the fixture. “W” on the lens
indicates wide angle, “N” indicates narrow angle. For more information, see
page 17.
- For a pool light (12 V only. No internal step-down transformer) that has a replacement FUSE ASSEMBLY, continue the procedure on the next page. If the light does NOT have a replacable fuse assembly, proceed to page 13.
REPLACING THE FUSE HARNESS ASSEMBLY (FOR 12 V LIGHTS ONLY)
- Using your fingers, carefully disconnect each fuse connector plug from the circuit board terminals. Carefully lift each connector plug upward, with small side-to-side movements while holding the circuit board terminals with a flat screw driver. Then gradually disconnect the connector plug from the terminal. Note: To avoid permanent damage to the circuit board, be sure not to pull the terminals off the surface of the circuit board.
- Once the fuse connector plugs are removed from the circuit board terminals, separate the fuse assembly from the light wire harness by pressing down on the fuse release lever, then gently pull apart.
- Insert the new fuse harness connector into the light cable harness plug and snap together.
- Using your fingers to carefully connect each fuse connector plug onto the circuit board terminals. Be sure not to press down to hard on the connector, this can damage the terminal connections on the circuit board.
- Continue with “INSTALLING THE INTELLIBRITE® 5G POOL LIGHT ASSEMBLY WITH NEW GASKET” on page 13.
REMOVING THE LIGHT CIRCUIT BOARD ASSEMBLY
- Using a ¼” nut driver, carefully remove the four retainer nuts from the light assembly (see illustration on next page). Place the nuts aside for reinstallation.
- Unplug the two connector plugs from the circuit board. Lift up the circuit board and remove it from the light housing base.
- Carefully lift off the old thermal strips from the base of the light housing base and discard.
- Place the two new thermal strips (provided) over the circuit board studs in the base of the light housing.
- Place the light circuit board over the base studs and seat the circuit board on top of the thermal strips. Be sure the two connecting wires are not caught between the housing and the edge of the circuit board.
- Using a ¼” nut driver, tighten each of the four (4) retaining nuts to a torque value of 6.0 (minimum) to 8.0 (maximum) in-lbs to secure the circuit board. DO NOT OVERTIGHTEN THE CIRCUIT BOARD NUTS.
INSTALLING THE INTELLIBRITE® POOL LIGHT ASSEMBLY WITH NEW GASKET (see
illustration on next page)
WARNING
Be sure to install ALL of the four (4) retaining nuts. These nuts ensure
proper electrical ground. Failure to install all of the retaining nuts could
create an electrical hazard which could result in death or serious injury to
pool users, installers or others due to electrical shock.
-
Install NEW GASKET ONTO LENS: Stretch the gasket around the circumference of the lens. Be sure the gasket is installed evenly around the lens.
-
ALIGN LENS/GASKET ONTO LIGHT HOUSING:
-
a) With the light housing resting on its base, place the lens/gasket on top of the light housing.
-
b) Rotate the lens/gasket to align the letter “W” (“WIDE” angle) on the lens with the brass nut in the housing (see diagram on page 14 for brass nut location).
Note:
The IntelliBrite light lens ships from the factory in the ‘WIDE’ (W) angle position. The “wide” position of the lens is typically used for lights located either side of the pool. The “narrow” position of the lens is typically used for lights located either end of the pool. To use the “NARROW” angle light beam, rotate the lens/gasket to align the letter “N” on lens. Note: For more information about using the “WIDE” and NARROW angle lens, see page 17. -
INSTALL UNI-TENSION CLAMP: With the hook ends of the circular uni-tension clamp pointing down, spread the clamp and place it in the “U” recesses of the locking levers. Be sure the hook ends of the clamp are located between the pair of locking levers as shown below and that the wire clamp is properly engaged with all of the lock levers.
-
Place a cloth on the ground to protect the lens. Turn the light over so the lens is resting on the cloth. Be sure the orientation of the wire clamp and the bolt connection is positioned at 45°.
-
Tighten the bolt and nut until the distance between the ends of the clamp equals ¼-inch or less. Continue on next page.Position the wire clamp (nut and bolt) about 45° between the PILOT SCREW and BOLT/NUT.
-
Coil at least four (4) feet of cord around the light fixture (see Figure 1 on page 6). This allows the light to be serviced after the pool is filled with water.
-
Connect the three light wires (or two wires) to the corresponding light circuit wires in the Junction Box. For three wire connection: Connect the black wire to power, white wire to common, and the green wire to ground. Secure the Junction Box cover.
-
Install the light assembly into the pool niche.
IMPORTANT: Be sure to insert the TAB on the lower part of the face ring into the niche SLOT (located on the lower part of the niche). This is important to secure the lower part of the light assembly onto the niche before tightening the pilot screw. -
Carefully tighten the special bronze pilot screw to secure the upper part of the light assembly onto the niche.
-
IntelliBrite Pool Light
-
Final check for proper IntelliBrite® Light operation: Switch on the main switch or circuit breaker to the system and the switch that operates the IntelliBrite light itself. The light should illuminate when power is applied. If not recheck the installation steps starting with Step 1 (page 4).
Wide and Narrow Angle Lens Adjustment
Wide and Narrow Angle Lens Feature
The IntelliBrite light lens geometry provides a choice of “wide” or “narrow”
angle light beam to suit various size pools. For lights located on either side
of the pool, rotate the lens to the ‘wide’ (W) angle position, which will
provide a wider angle light beam for greater underwa-ter coverage and light
reflection the width of the pool. For lights located either end of the pool,
rotate the lens to the ‘narrow’ (N) angle light beam position for increased
underwater light intensity and distance. Note: The IntelliBrite light lens
ships from the factory in the ‘WIDE’ (W) angle position. WIDE ANGLE LIGHT
BEAM (FOR SIDES OF POOL) NARROW ANGLE LIGHT BEAM (FOR ENDS OF POOL)
IntelliBrite® 5G Pool Light Assembly Replacement Kit
Part Numbers
Note:
A 120 VAC to 12 VAC external transformer is required for the 12 VAC model
IntelliBrite pool white light. See page 1 for more information.
IntelliBrite® Pool Light Assembly Replacement Kit Part Numbers
Note:
The 120 VAC IntelliBrite pool light has an integrated 12 VAC transformer.
Replacing the IntelliBrite® 5G Spa Light Face ring and Gasket (P/N 640045)
or Gasket and Lens (640046) see page 21
Note:
When replacing an IntelliBrite 5G Spa light assembly, a new spa light assembly
includes a light engine, lens, gasket and face ring (for part light assembly
part numbers, see page 23 ).
D A N G E R !
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION
Always disconnect power to the pool light at the circuit breaker before
servicing the light. Failure to do so could result in death or serious injury
to installer, pool professional, pool users, or others due to electrical
shock.
-
Turn off main electrical switch or circuit breaker, as well as the switch which operates the IntelliBrite underwater light itself.
WARNING
Always install a new lens gasket (P/N 79108600). Whenever disassembling the IntelliBrite light assembly. Failure to do so may permit water to leak into the assembly which could cause: (a) an electrical hazard resulting in death or serious injury to pool users, installers, or others due to electrical shock, or (b) breakage of the lens, which likewise could result in serious injury to pool users, installers, or bystanders, or in damage to property. -
REMOVING THE INTELLIBRITE SPA LIGHT: Remove the pilot screw at top of face ring, remove the light assembly from the niche. Place the assembly on the deck.
Note:
It is not necessary to drain down the pool.
WARNING
Be sure to keep the pilot screw from the IntelliBrite light. This screw mounts and electrically grounds the housing securely to the mounting ring and wet niche. Failure to use the screw provided could create an electrical hazard which could result in death or serious injury to pool users, installers or others due to electrical shock. -
Using a #3 Phillips head screwdriver, loosen the CLAMP SCREW and remove uni-tension wire clamp from the face ring.
-
Remove the face ring and wire clamp from the light housing and set aside for installation later.
- Spa light fixture with lens, gasket and face ring attached
Note: A 120 VAC to 12 VAC external transformer is required for the 12 VAC model IntelliBrite® Spa Light. See page 1 for more information.
Note: The IntelliBrite Spa Light fixture is a sealed light assembly with no replaceable circuit board assembly. Only the lens, gasket and face ring can be removed from the sealed light assembly for replacement. See page 23 for replacement kit part numbers.
- Spa light fixture with lens, gasket and face ring attached
-
With the light assembly resting on its base, carefully pry off the gasket to release the lens. Discard the gasket. A NEW LENS GASKET MUST BE USED EACH TIME THE SPA LIGHT IS REASSEMBLED
-
Disconnect the IntelliBrite spa light assembly cord from the junction box. Cut the cord near the back of the light assembly and discard the light. See page 4 for replacement instructions for the new spa light.
-
INSTALLING THE INTELLIBRITE® SPA LIGHT WITH NEW GASKET: Install a new gasket during reassembly of the IntelliBrite spa light. A NEW LENS GASKET MUST BE USED EACH TIME THE LIGHT IS REASSEMBLED.
-
Install the new gasket onto the lens: With the light housing resting on its base, place the lens then the gasket on top of the light housing.
-
INSTALL FACE RING: Place the face ring on top of the lens/gasket/housing. Rotate the light housing to align the “TOP” position arrow indicator label on the rear of the housing is aligned with the pilot screw on the face ring. Place the face ring on top of the gasket. Make sure that the lens and gasket are centered correctly on the light housing.
-
Aligning the face ring and lens: Align the face ring and vertical line on the lens so that the letter “O” in the word “TOP” and the small arrow above it) on the surface of the lens points to the 12 O’clock position and with pilot screw hole on the face ring.
-
INSTALL UNI-TENSION CLAMP: With the hook ends of the circular uni-tension clamp pointing down, spread the clamp and place it in the “U” recesses of the locking levers. Be sure the hook ends of the clamp are located between the pair of locking levers as shown below and that the wire clamp is properly engaged with all of the lock levers.
-
Place a cloth on the ground to protect the lens. Turn the light over so the lens is resting on the cloth. Be sure the orientation of the wire clamp and the bolt connection is positioned at 45°. Tighten the bolt and nut until the distance between the ends of the clamp equals ¼-in or less.
-
PROCEED TO “Replacing the IntelliBrite® Spa Light Assembly (in an existing pool or spa)” on page 4 for spa light assembly installation instructions.
IntelliBrite® 5G Spa Light Replacement Kit Numbers
IntelliBrite® 5G Color Spa Light
Assembly (Listing UL/CSA) IntelliBrite® 5G
White Spa Light Assembly (Listing UL/CSA)
Product
Model| Voltage| Cord Length
(feet)
---|---|---
640140| 120V| 30’
640141| 120V| 50’
640142| 120V| 100’
640143| 120V| 150’
640144| 120V| 250’
640150| 12V| 30’
640151| 12V| 50’
640152| 12V| 100’
640153| 12V| 150’
Note:
A 120 VAC to 12 VAC external transformer is required for the 12 VAC model
IntelliBrite spa light. See page 1 for more information.
PENTAIR WATER POOL AND SPA, INC.
1620 HAWKINS AVE., SANFORD, NC 27330 •
919-566-8000
10951 WEST LOS ANGELES AVE., MOORPARK, CA 93021 •
805-553-5000
WWW.PENTAIRPOOL.COM
All Pentair trademarks and logos are owned by Pentair, Inc. Pentair Aquatic
Systems™, IntelliBrite®, EasyTouch®, IntelliTouch®, and SunTouch® are
trademarks and/or registered trademarks of Pentair Water Pool and Spa, Inc.
and/or its affiliated companies in the United States and/ or other countries.
Unless expressly noted, names and brands of third parties that may be used in
this document are not used to indicate an affiliation or endorsement between
the owners of these names and brands and Pentair Water Pool and Spa, Inc.
Those names and brands may be the trademarks or registered trademarks of those
third parties. Because we are continuously improving our products and
services, Pentair reserves the right to change specifications without prior
notice. Pentair is an equal opportunity employer.
© 2015 Pentair Water Pool and Spa, Inc.. All rights reserved. This document is
subject to change without notice.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>