Tekelek 9-6140-01 Cellular Ultrasonic Device Instruction Manual

June 3, 2024
Tekelek

Tekelek 9-6140-01 Cellular Ultrasonic Device

Tekelek-9-6140-01-Cellular-Ultrasonic-Device

Purpose

  • This instruction defines the guidelines in opening and closing Tekelek GSM & LTE ultrasonic devices for battery replacement.
References
  • Screws x 4: NO.4 x 3/4″ SS PAN POZI” Self Tapping
  • Battery x 4: VARTA Power 1 C Cell Battery
  • O-Ring: 82,50 x 2,20 Silicone Rusty Red O-Ring (30 Shore)
Guidelines
  • Turn unit over and remove void if removed sticker from base of unit.

  • Untighten 4 screws from base in a diagonal sequence.Tekelek-9-6140-01-Cellular-Ultrasonic-Device-2

  • Remove screws fully from base.

  • Standing the unit in the upright position, to prevent batteries from falling out, separate top and bottom plastics.

  • Remove existing batteries, replace with new batteries observing polarity.

  • Remove old O-ring.

  • Place new O-ring on top plastic ensuring O-ring is seated correctly in groove.Tekelek-9-6140-01-Cellular-Ultrasonic-Device-3

  • Mate top and bottom plastics taking care not to damage connectors.
    Note: The 4 legs of the top plastic will only mate with the holes of the bottom plastic in a certain order. Notched leg – Notched hole. This ensures that the connectors are aligned upon mating.

  • Inspect O-ring is still seated correctly.

Secure plastics using 4 screws in the following sequence:

  • Place diagonal screws and tighten initially to 2.5±0.3kgf.cm
  • Again, using diagonal screws, final torque all screws to 7.0±0.3kgf.cm
  • Once secure, inspect the seal between the plastics to ensure it has been closed correctly and that the O-ring has not been caught between the plastics. Once closed correctly there should be a consistent gap of 0.5mm around the full circumference of the unit.