REAL-EL STAB SLIM-300 Automatic Voltage Regulator User Manual
1. BUYER RECOMMENDATIONS
-
Unpack the device Make sure there are no accessories left in the box. Check up the device for damage; if the product was damaged during transportation, address the firm, which carried out the delivery; if the product functions incorrectly, address the dealer at once.
-
Check up the package contents and availability of the warranty Make sure the warranty card
has a shop stamp, a legible signature or the seller’s stamp and purchase date, and the goods number corresponds to that in the warranty card. Remember: in case of warranty card loss or discrepancy of numbers you forfeit the right for warranty repairs. -
Do not switch on the device immediately after you bring it into a room from environment with negative temperature! After unpacking, the device should be kept in conditions of room temperature for at least 4 hours.
-
Before installing and using the device, read this Manual carefully and keep it for future
2.APPLICATION
Automatic voltage regulator (AVR) is designed for providing various equipment with high-quality stable electric power supply in conditions of significant and continuous deviations of mains voltage and protecting consumer devices against overload, influence of high frequency and impulse interferences.
3. SAFETY PRECAUTIONS
Before using this device, please read the safety rules carefully:
ϜIt is strongly forbidden to open the cover of the device, there is high
voltage inside. If some problems occur, please read the operation manual
carefully and address an authorized service
center. For the list of authorized service centers please go to www.real-
el.com.
ϜDo not let liquid get inside the device, it can cause short circuit or
electric shock.
ϜIn case there are signs of improper operation of the device (sparkling,
unusual smells, etc.), unplug the device from the mains immediately and
address your nearest authorized service center.
ϜIt is forbidden to connect the automatic voltage regulator to devices with
power consumption higher than its maximum output power. It can cause breakdown
of the device.
ϜThis device is not intended for use by persons (including children) with
reduced physical, mental capabilities, lack of experience or knowledge; use of
the device by such persons is permitted only under the condition of
supervision or instructions for the use of household appliances by persons
responsible for their safety.
Ϝ Children should be supervised by authorized personnel to exclude their
playing with the appliance.
ϜDo not use the appliance with a damaged power cord or plug, or after handling
liquids, falling or any other damage. To avoid electric shock, do not attempt
to disassemble or repair the appliance yourself. If necessary, contact a
specialized service center.
It is strongly forbidden to operate the device in the following conditions:
- LQGXVW\HQYLURQPHQWRUHQYLURQPHQWFRQWDLQLQJKLJKO\LQԜDPPDEOHJDV
- at temperature higher than 40 °C or lower than 0 °C;
- at humidity level higher than 90 %;
- in direct sunlight or next to heating elements;
- in vibration areas;
- outdoors.
Ϝ,QFDVHRIԛUHXVHRQO\SRZGHUԛUHH[WLQJXLVKHUDVZDWHUFDQFDXVHHOHFWULFVKRFN
ϜThe automatic voltage regulator should be installed in proximity to power
supply, then it will be easier to unplug the device if necessary.
Caution! There is high voltage inside on the insulation elements which can result in electric shock.
4. PACKAGE CONTENTS
ϜAutomatic voltage regulator – 1 pc
Ϝ Operation Manual – 1 pc
Ϝ Warranty card – 1 pc
Features
ϜHigh precision of output voltage
ϜCPU control
ϜProtection against high or low output voltage
ϜWall mount Slim design metal case
ϜWide range of input voltages 150-270 V
ϜDigital displays of input/output voltage
ϜToroidal transformer with built-in restorable thermal protection
ϜOptional 6s or 180s Switch On Delay time
Operation Manual
5. DESCRIPTION
-
Digital display of the output voltage level
-
L » – low voltage protection;
-
H » – high voltage protection;
-
C » – transformer temperature protection
-
POWER : LED (green) lights up when there is a input voltage $ Digital display of the input voltage level
-
DELAY : LED (yellow) EOLQNVDWZRUNLQJRԚGHOD\
& PROTECTION: LED (red) lights up in case of accident (high/ low voltage protection operation, transformer thermal overload) -
Wall mounting holes
-
( Output socket (the STAB SLIM-2000 has 2 output sockets) Delay selection button (180 or 6 s): while pressing the delay time will be 180 s, when not pressed – 6 seconds
-
RESET/OFF: power switch with built-in fuse + Built-in power cord
6. MOUNTING
PSRUWDQW %HIRUH PRXQWLQW WKH UHJXODWRU PDNH VXUH WKDW DOO Н[LQJ elements
durable fastened to the wall!
ϜFor securely wall mounting it is necessary to determine the type of wall
material (wood, brick, concrete, drywall, and etc.) for corresponding fastener
selection.
ϜMounting stabilizer location should be close to the wall outlet, considering
the stabilizer power cord length.
ϜNext, make a mounting fasteners (not included) to the wall, considering the
wall mounting holes location ‘ on the stabilizer rear panel (see Fig. 2).
Ϝ7KHQKDQJWKHVWDELOL]HURQԛ[LQJHOHPHQWV
Automatic Voltage Regulator
7. INSTALLATION
Attention! Before connecting the regulator, make sure that all consumer
devices connected to it are off.
ϜBefore installing the AVR, please make sure that total power of all voltage
consumers is lower than AVR power. Taking into account the starting load and
power factor of voltage consumers, it is necessary to apply power margin
factor of 1.2–1.5; for such equipment as air conditioners, fridges and other
electric motors it should be 1.5–2.
Attention! When choosing an AVR, it is necessary to know that reduction of
input voltage
LQFUHDVHVYDOXHRILQSXWFXUUHQWZKLFKPHDQVWKDWPD[LPXPSRZHURI$95LVUHGXFHGWRR
Such dependence is shown in the graph below:
Note. Adhere strictly to such dependence. If the condition stated above is not
adhered to, warranty servicing becomes void!
ϜPlug the stabilizer power cord + in the wall outlet.
ϜTurn on stabilizer with switch * (RESET position).
ϜIf the AVR operates properly, green LED # illuminates, and yellow LED % will
blink. At the same time the digital indicator ” will show the input voltage.
The total delay makes 6 or 180 s depending on the “DELAY” button “RESET/ OFF”
) position. After the delay time yellow LED %WXUQVRԚDQG digital indicator $
will show the output voltage of the regulator. And only after that you can
turn on the connected devices, consumers.
ϜWhen the mains voltage exceeds the allowable rate (lower threshold is 150 V,
upper threshold is
270 V) the red LED & illuminates, the AVR disconnects the load automatically.
Attention! It is recommended to switch off the AVR and every connected
consumer device when the power supply is dropped.
8. PAUSE FUNCTION
ϜThe Pause mode feature is designed to protect equipment in case of frequent
drops of the mains supply. This is particularly important for consumer
appliances with electric motors or compressors.
After power supply has been recovered, the AVR switches on within 6 or 180
seconds, depending on the ” DELAY ” button ” RESET/ OFF ” position.
9. PROTECTION FUNCTION AGAINST HIGH AND LOW INPUT VOLTAGE, OVERLOAD AND
OVERHEAT
ϜThe stabilizer is equipped with an circuit overvoltage and undervoltage
protection. In the case of PDLQVYROWDJHGHYLDWLRQRYHU9RUEHORZ9LW WXUQVRԚ
WKHORDGDXWRPDWLFDOO\$W WKHVDPH time red LED & illuminates. When the input
voltage range returning to 150-270 V the stabilizer automatically resumes
operation.
ϜIn case of overload or short-circuit AVR power switch will triggered. After
elimination overload cause or short circuits, press AVR power switch (RESET
position), and stabilizer will resume operation.
10. TROUBLESHOOTING
Problem | Cause | Solution |
---|---|---|
The AVR does not start. | 1. The switch is off. |
2. There is no voltage in the power supply network.
3. The fuse has activated. 4.The load connected is too powerful.
| 1. Press the switch once again.
2. Make sure that power supply is available.
3. Disconnect the AVR from the power supply and reset the circuit breaker
4. Disconnect some load.
The AVR is turned on, but there is no output voltage.| The AVR is out of
order.| If the problem is not eliminated, please address an authorized service
center.
The AVR often produces clicking sounds.| Input voltage is very unstable.| It
is normal. The AVR regulates output voltage.
The AVR has disconnected the load. Active red indicator.| Input voltage is
beyond possible regulation range of 150 – 270 V.| When input voltage is
normalized, the AVR tuns on automatically.
If none of the above methods can solve the problem, please seek professional
advice at your
nearest service center. Never attempt to repair the product by yourself.
11. SPECIFICATIONS
Model | STAB SLIM-300 | STAB SLIM-500 | STAB SLIM-1000 | STAB SLIM-2000 |
---|---|---|---|---|
Maximum load | 300 VA/240 W | 500 VA/400 W | 1000 VA/800 W | 2000 VA/1600 W |
Safety fuse | 3 A | 5 A | 7 A | 15 A |
Input voltage | ~150–270 V/50 Hz | ~150–270 V/50 Hz | ~150–270 V/50 Hz | ~150–270 |
V/50 Hz
Output voltage| ~230 ± 8 % V/50 Hz| ~230 ± 8 % V/50 Hz| ~230 ± 8 % V/50 Hz|
~230 ± 8 % V/50 Hz
Switching time| y 10 ms| y 10 ms| y 10 ms| y 10 ms
Short circuit protection| available| available| available| available
Environment temperature| 0 – 40 °C| 0 – 40 °C| 0 – 40 °C| 0 – 40 °C
Humidity| up to 90 %| up to 90 %| up to 90 %| up to 90 %
Dimensions| 330 × 160 × 60 mm| 330 × 160 × 60 mm| 330 × 160 × 60 mm| 370 × 200
× 60 mm
Weight| 2.2 kg| 2.6 kg| 3.2 kg| 5 kg
Notes:
- Technical specifications given in this table are supplemental information and cannot give occasion to
- Technical specifications and package contents are subject to change without notice due to the improvement of
TM REAL-EL production
.
Models: STAB SLIM-300, STAB SLIM-500, STAB SLIM-1000, STAB SLIM-2000
Manufacturer: ENEL GROUP OU, Katusepapi tn 6, Lasnamäe linnaosa, Tallinn,
Harju maakond, 11412, Estonia. Made in China.
® Registered Trademark of ENEL GROUP OU. Estonia.
Read More About This Manual & Download PDF:
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>