WQ610RF Wireless Slim Programmable Thermostat
Installation Guide nstaller’s Quick Guide
WQ610RF Wireless Slim Programmable Thermostat
View all SALUS thermostat manual
RT510T
Introduction
The SALUS Quantum WQ610 and WQ610RF thermostats are Boiler Plus compatible thermostats, designed specifically to control central heating boilers and also in the case of the RF versions, electrical panel heaters. They have our new load compensation (ITLC) software with Volt free switch and also Opentherm 4.0 connections, so you can choose the method of control to suit your boiler / installation. Please note that the Boilers need to have an OpenTherm Association license to be fully compatible with WQ610 range(should you wish to connect to the OpenTherm terminals A and B). Please verify if this requirement is met with your Boiler Manufacturer.
Product Compliance
This product complies with the essential requirements and other relevant provisions of the following EU Directives: RED:2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of Conformity is available on: www.saluslegal.com WQ610RF: 2405-2480MHz; <14dBm
Saf ety Information
Use in accordance with national and EU regulations. Use the device as
intended, keeping it in a dry condition. Product is for indoor use only.
Installation must be carried out by a qualified person in accordance with
national and EU regulations.
WARNING! Always ensure the AC mains power is switched off before
installing or working on any components.
Technical Specification
| WQ610 Thermostat| WQ610RF Thermostat
---|---|---
Thermostat supply| 230V AC| Lithium Battery (Rechargable)
Thermostat rating max| 3 (1) A| –
OpenTherm terminals| A / B| –
Outputs| Voltage free NO / COM terminals| –
Temperature range| 5°C — 35°C| 5°C — 35°C
Thermostat display accuracy| 0.5°/ 0.11| 0.570.1X
Thermostat display resolution| 0.5°C| 0.5°C
ErP control class| Class V| Class V
Radio Frequency| | 2.4 61-1z
Dimension [mm]| 86 x 86 x 27 [mm]| 86x 86 x 11[mm]
WQ610 Receiver
Receiver supply| 230 V AC
Receiver rating max| 16 (5) A
OpenTherm terminals| A / B
Outputs| Voltage free NO / COM terminals
Radio frequency| 2.4 Glz
Dimension [mm]| 98 x 98 x 32[mm]
Button Functions
- MENU – enter the menu options, press and hold for 3 seconds to return to main screen without saving changes.
- DOWN – decrease the temperature and move through the menus.
- UP – increase the temperature and move through the menus.
- TICK – confirm changes and enter menus. Press and hold for 3 seconds to exit User Menu and save changes. Press and hold to cancel BOOST feature or temporary override (whilst in normal screen).
- ON – When in Manual Mode, ON will turn the boiler on.
- OFF – When in Manual Mode, OFF will turn the boiler off.
- AUTO – Receiver operates in automatic mode according to the thermostat.
- MANUAL – Receiver output is controlled by the On/Off slide switch.
LCD Icon Description
- Menu/Settings description
- Clock 24hr/AM/PM
- Temperature unit
- Heating indicator (icon is animating when there is heating demand)
- RF Connection indicator
- Current Temperature / Setpoint Temperature
- Holiday mode indicator
- Temporary override mode
- Settings icon
- Battery indicator
- Schedule program number
- Schedule mode icon
- Day indicator/ SET information
WQ610 Thermostat Terminals Description
Terminal | Description |
---|---|
A/B | OpenTherm Communication Wires only |
NO | Volt free connection (Switch) |
COM | Volt free connection (Common) |
L;N | Supply (230 V AC) |
WQ610RX Receiver Terminals Description
Terminal | Descriptio n |
---|---|
B/A | OpenTherm Communication Wires only |
NO | Volt free connection (Switch) |
COM | Volt free connection (Common) |
L;N | Supply (230 V AC) |
WQ610 Wiring Diagram
** DO NOT connect to OpenTherm terminals unless your boiler is OpenTherm
Association approved and has the OpenTherm Logo.
WQ610RF Wiring Diagram**
Please ensure the boiler has 230 V switching before wiring in this way.
Power Up and Configuration
The WQ610RF thermostat contains a re-chargeable Lithium battery. When the battery level is below 10%, the thermostat will display “PLEASE RE-CHARGE BATTERY”. Please re-charge for a full 24 hours using a standard Micro USB charger. Thermostat operation will not be affected during the charging period
To activate thermostat, press TICK buttonfor 3 seconds (RF version) only.|
Language ”ENGLISH” is flashing, press UP or DOWN, choose your language,
then TICK to confirm.
Using UP or DOWN, choose the time format between 24 hr and 12 hr format.| Using UP or DOWN, set the hour and then press TICK, which will then move to minutes, that can be changed in the same way.
Using UP or DOWN, set the year and then press TICK.| Using UP or DOWN, set the
month and then press TICK, which will then
move to days, that can be changed in the same way.
If you select NO, thermostat will use dafult settings and revert to normal
screen.| Once you have properly connected your thermostat with the Open
Therm terminals the OT message will be shown on the screen.
For more Opentherm details, go to the Opentherm: Configuration section.
Accessing Advanced Settings Menu
Advanced Settings allow the installer / landlord to adjust the thermostat to suit individual installation requirements. Do not adjust the settings unless you are competent to do so. The Advanced Settings may be locked by the creation and activation of a 4 digit PIN code. Please keep your PIN safe and secure.
Press MENU.| Using UP or DOWN, navigate to Advanced submenu and press TICK.
Press TICK to enter Daylight Saving Time Menu.| Using UP or DOWN, select ON or
OFF. Press TICK to confirm.
Press TICK to select the type of heating control you prefer.| ITLC helps to
improve system efficiency and end user comfort.
Default is ITLC Radiators (disabled if Opentherm connected).
Press TICK to confirm or DOWN to see the next option.
This option is only for electrical radiators. Press TICK to confirm or DOWN to
see the next option.| This is a simple ON/OFF algortihm control based on the
set point. Using UP or DOWN, you can select the SPAN value. Press TICK to
confirm or DOWN to go to next option.
Using TICK, then UP and DOWN you can select FROST value . (5 – 17 degrees C).
Press TICK to confirm or DOWN to see the
next option.| Using TICK, then UP and DOWN you can set the maximum and the
minimum room temperature.
If you think that the temperature displayed on the thermostat is not accurate
due to its location, you can calibrate it using this menu with values between
-3.5 / +3.5 degree.| This will start your boiler early to improve energy
saving.
This will stop your boiler early to improve energy saving.| Press TICK to
allow installer or landlord to set service reminder and lock temperature
level.
Using UP or DOWN, you can select YES and press TICK to confirm,or you can
select NO and go to point 20.| Using UP or DOWN, select the number of days
service alert should last for.
Using UP or DOWN, select the warning period before the service alert will be
activated, then press TICK.| Using UP or DOWN, select the lock temperature
and then press TICK.
Press TICK and enter installer’s phone number using UP and DOWN buttons.|
Allows you to create a PIN which may be used to limit access to your settings.
Using UP or DOWN, create your PIN access, thenTICK
to confirm.
This option will allow you to lock your advanced settings using your access PIN. Using UP or DOWN, create your lock advanced settings, then TICK to confirm.
| Using UP or DOWN, enter the PIN code number. Press TICK to confirm every
digit.
This option will allow you to set the displayed temperature accuracy.| The
temperature display accuracy can be 0.5 or 0.1
| Use your created PIN to lock access
to advanced settings menu.
Temporary Manual Override
For overriding the schedule to bring the HEAT on, use the UP button to
increase the temperature and press TICK to accept the change.
This setting will be valid until the next scheduled program.
OpenTherm: Configuration
This menu will only be visible if your boiler is OpenTherm compatible and you
have connected to terminals A and B.
OpenTherm is a method of control used by modern heating systems. Instead of
switching a boiler on and off at intervals, modulating control allows the
amount of heat provided by the boiler to be controlled to match the varying
demand from the thermostat. This means the customer has greater system
efficiency, energy saving and room comfort from our heating controls.
Temperature Values for Opentherm
Please note that below values can be manually set only if the boiler allows it.
CH (Central Heating) | HW (Hot Water) |
---|---|
MIN TEMP: 25 °C | MIN TEMP: 40 °C |
MAX TEMP: 80 °C | MAX TEMP: 80 °C |
DEFAULT TEMP: 75 °C | DEFAULT TEMP: 60 °C |
This screen display will be displayed when OT is connected. To change the
settings for DHW and/or CH – press MENU and go to ADVANCED SETTINGS.| Using UP
or DOWN, navigate to HW SETPOINT and press ICK.
Using UP or DOWN, adjust the
temperature and then press TICK.| Press TICK to enter menu. Using UP or DOWN,
set the maximum opentherm central heating temperature.
| Using UP or DOWN, set the value then press TICK for 3 sec to confirm and
exit to main screen.
OpenTherm related errors:
SERVICE REQUEST ERROR| LOCKOUT RESET ERROR
LOW WATER PRESSURE ERROR| GAS FLAME FAULT ERROR
AIR PRESSURE FAULT ERROR| WATER OVER TEMPERATURE ERROR
** If an Opentherm fault is detected on the boiler, the thermostat will
display the above messages. These errors are not related to the thermostat.
WQ610RF: Pairing with the Receiver**
The pairing between the thermostat and the receiver is already done at the factory. However, should you need to re-pair the units then this can be done using the User Menu. The link may also be tested from the User Menu to show pairing link has been successful. Before pairing, the Receiver should be unplugged, then plugged back in. During the pairing process, the distance between the Thermostat and the Receiver should beat least 1m.
Turn the receiver OFF and ON twice to reset. Ensure receiver switches are ON and AUTO. Red LED should be flashing. Enter thermostat MENU and scroll down until you will see “PAIR WITH RECEIVER” option. Select YES to proceed with Pairing. Now your thermostat is looking for the receiver. A 10 minute counter will appear on the screen. Upon connecting to the receiver, the thermostat will display the message “PAIRING SUCCESSFUL” and return to normal operation afterwards. The red LED will stop flashing when the pairing is successful.
WQ610RF: Testing Link
Enter MENU and scroll down until you
find „TEST LINK” option. Press TICK button to continue. Now your thermostat is
sending a TEST message to the receiver with the expectation of receiving a
response. While testing, both red and green LED will be intermittently
flashing. Your thermostat will indicate that the connection has been tested
successfully and will return to normal operation.
Additional installation notes for WQ610:
Head Office:
SALUS Controls
Units 8-10
Northfield Business Park
Forge Way, Parkgate
Rotherham , S60 1SD
Email: sales@salus-tech.com
www.salus-tech.com
SALUS
Controls is a member of the Computime Group.
Maintaining a policy of continuous product development SALUS Controls plc
reserve
the right to change specification, design and materials of products listed in
this brochure without prior notice.