SALUS RT510 Electronic Thermostat Installation Guide
- June 6, 2024
- SALUS
Table of Contents
- SALUS RT510 Electronic
- Introduction
- Product compliance
- Safety Information
- Technical specification
- Button functions
- Setting the time
- Programming – automatic mode
- Temporary Override mode
- Manual Mode and setting setpoint temperature
- Hourly temperature Override Mode (+Hr)
- Frost Protection
- Sleep mode
- Holiday Mode
- Begin the pairing process
- End the pairing process
- Test the pairing process
- Installer mode
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SALUS RT510 Electronic
Thermostat
Introduction
RT510 / RT510RF is a programmable room thermostat used to control room temperature. Device launching heating system by shorting terminal blocks, simultaneously informing the action and showing this information on the LCD display. Extended features allows us to use various operating modes – automatic (time schedules), manual, frost protection or holiday. Before use please read this manual carefully. Use only AA 1.5 V alkaline batteries in the thermostat. Place the batteries into the battery slot located under the cover. Do not use rechargeable batteries.
Product compliance
Directives: EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. Full information is available on the website www.saluslegal.com
Safety Information
Use in accordance to national and EU regulations. Use the device as intended, keeping it in dry condition. Product for indoor use only. Installation must be carried out by a qualified person in accordance to national and EU regulations.
Technical specification
| RT510 Thermostat| RT510TX Thermostat
---|---|---
Thermostat supply| 2 x AA alkaline batteries| 2 x AA alkaline batteries
Thermostat rating max| 3 (1) A| –
Outputs
| Voltage free NO / COM / NC
terminals
|
–
Temperature range| 5 – 35°C| 5 – 35°C
Temperature accuracy| 0.1°C or 0.5°C| 0.1°C or 0.5°C
Control algorithm| TPI or hysteresis ±0.25°C| TPI or hysteresis ±0.25°C
Radio frequency| –| 868 MHz
Dimension [mm]| 120x96x27| 120x96x27
RXRT510 Receiver
RXRT510 Receiver
Receiver supply| 230 V AC
Receiver rating max| 16 (5) A
Outputs| Voltage free NO / COM terminals
Radio frequency| 868 MHz
Dimension [mm]| 96x96x27
Button functions
RT510/RT510TX Thermostat
- Boost function
- Manual Mode
- Frost protection / Holiday Mode
- Increase button
- Decrease button
- When in Manual Mode, ON will turn the boiler on.
- When in Manual Mode, OFF will turn the boiler off.
- The receiver operates in automatic mode according to the thermostat
- The receiver output is controlled by the On/Off slide switch.
LCD Icon description
- Day of the week
- Program number
- Program indicator
- Settings
- Temperature measured / set
- Boost function
- Low battery status
- Wireless connection with the receiver
- Heating Mode On
- Manual Mode On
- Holiday Mode On
- Frost Protection Mode On
- Temperature unit
- AM / PM
- Clock
RT510 Terminals description
Terminal | Description |
---|---|
1 – COM | Common Terminal |
2 – NC | Switched Live OFF |
3 – NO | Switched Live ON |
RXRT510 Receiver terminals description
Terminal | Description |
---|---|
NO | Switch Terminal |
COM | Common Switch Terminal |
L, N | Supply (230 V AC) |
DIP Switch Settings
Control feature | TPI | Span |
---|---|---|
Operation | When TPI is selected on | When Span is selec- |
DIP switch № 2, the DIP | ted on DIP switch № | |
switch № 1 is functional. | 2, the DIP switch № | |
You can choose the | 1 is not functional. | |
Cycles Per Hour between | The SPAN value is | |
a lower comfort level | set to ± 0.25°C – it is | |
(6CPH) and a higher | recommended to use | |
comfort level (9CPH). | with heating devices. |
RT510 Wiring diagram
RT510RF Wiring diagram
Note: If you are using the RT510RF pack, the pairing between the thermostat and the receiver is already done.
Setting the time
- Press the buttons SELECT and SET together for 3 sec.
- Press or to select the hour format.
- Press SELECT to confirm.
- Press or to set the hour.
- Press SELECT to confirm.
- Press or to set the minutes.
- Press SELECT to confirm.
- Press or to set day of the week.
- Press SET to confirm.
- Thermostat will return to the main screen.
Programming – automatic mode
In this mode, user can set the schedules for thermostat (temperature setpoints for specific periods of time). You have the option to choose between a 5-2 days programme or a daily one by using the parameter d04 from Installer mode.Programmed schedules should use all time periods.
- Press the SET button to start programming.
- Use the or button to select day / days from which you want to start programming.
- Press SELECT to confirm.
- Use the or button to set the hour to start the program #1.
- Press SELECT to confirm.
- Use the or button to set the minutes to start the program #1.
- Press SELECT to confirm.
- Use the or button to set the temperature for program #1.
- Press SELECT to confirm.
- Follow steps 4-9, to define programs 2-6. Press SET button to end programming.
Temporary Override mode
This function is available only in automatic mode (schedule). If a new setpoint temperature will be set during the schedule – it will be maintained until next time interval starts according to a programmed schedule.
- Using or buttons set new setpoint temperature.
- After new setpoint temperature set, thermostat will return to the main screen.
Temporary Override mode will be disabled when new schedule will be set.
Manual Mode and setting setpoint temperature
In this mode thermostat does not work according to the programmed schedule but it will maintain selected temperature.
- Press button to activate the Manual Mode.
- Using or buttons set new setpoint temperature.
- After new setpoint temperature set, thermostat will return to the main screen.
To turn off the Manual Mode press button. Once the manual mode is off, the hand icon on the thermostat will disappear.
Hourly temperature Override Mode (+Hr)
This function is available in Automatic and Manual Mode. It is used to change the setpoint temperature for a specified number of hours (up to 9 hours). Once that time is over, thermostat returns to previous mode.
- Press +Hr button to set number of hours for temperature override (e.g. to set up override for 3 hours, press the button 3 times).
- Using or button set a new setpoint temperature for override.
- Press SET button to confirm.
Turning off hourly temperature override mode before time’s up
- Press the + Hr button until number of hours disappears from display.
Frost Protection
Temperature of the Frost Protection mode is set as default at 5°C. This temperature can be changed in Installer Mode in d03 parameter.
- Press button to turn On Frost Protection mode.
Turning Off the Frost Protection mode
- Press button again to turn Frost Protection de.
Sleep mode
- Hold and buttons simultaneously for 3 seconds to start the sleep mode.
- Thermostat is in sleep mode.
When the sleep mode is activated, all thermostat functions are paused.
- Press any key to deactivate sleep mode.
- Thermostat will return to the previous mode.
Holiday Mode
In this mode the “frost protection” temperature is maintained for a specific number of days.
- Hold down button for 3 seconds to activate the Holiday Mode.
- Use or button to set the number of days for Holiday Mode.
- Press SET button to confirm. You can set up to 31 days.
To turn off the Holiday Mode, hold down button for 3 seconds. The airplane icon should disappear from the display.
RT510TX thermostat pairing with the receiver
Note: If you are using the RT510RF pack, the pairing between the thermostat and the receiver is already done. If you want to re-pair thermostat with the receiver, make sure that the device is disconnected from the power supply and the switches on the receiver have been set to AUTO and ON. Then connect the receiver to the power supply and wait for the red LED to light steadily. Next switch to the OFF position and again to ON position quickly. The red flashing LED will confirm entering the pairing mode.
Begin the pairing process
- Press and hold TEST/PAIRING button for 3 seconds.
- (the pairing process takes up to 9 minutes)
End the pairing process
- Once devices are successfully paired, LED on the receiver will go solid red. Press and hold TEST / PAIRING button for 3 seconds to end the pairing process.
Test the pairing process
- Press TEST / PAIRING button to check the connection with the receiver.
- Press TEST / PAIRING button again to return to the main screen.
If you purchased an RXRT510 or RT510TX and intend pairing with other devices in the 5×5 range, please refer to the Receiver Units manual or the relevant manuals available at www.Salus-controls.EU
Installer mode
- Press three buttons at the same time for 3 seconds.
- Using SELECT button choose the parameter.
- Press SET to confirm.
- Using or buttons set a parameter value.
- Press SELECT to confirm.
- Follow steps 2-5, to set next parameters. To exit the installer mode, wait 10 seconds – thermostat will return automatically to the main screen.
dxx| Function| Parametr| Default value
---|---|---|---
d01| Temperature display increments| 0.1°C or 0.5°C| 0.5°C
d02| Temperature offset| +/- 3.0°C| 0.0°C
d03| Frost Protection setpoint temperature| 5.0°C – 17.0°C| 5.0°C
d04| Programmer selection| 5/2 or 24 hr (7d)| 52 d
Reset of the RT510 thermostat
- Press the RESET button once. You can use a paper clip. Your thermostat will be reset and will start up automatically.
Reset of the RT510TX thermostat
- Remove the batteries without pressing any button. Wait 2 minutes and insert the batteries again. Your device will be restarted.
NOTE:
When you want to change the batteries your device will use the internal memory to backup your settings. You have 30 seconds to change the batteries before losing your settings.
IMPORTER:
QL CONTROLS Sp. z o.o. Sp. k. ul. Rolna 4, 43-262 Kobielice
PRODUCER:
Salus Limited 6/F, Building 20E, Phase 3, Hong Kong Science Park, 20 Science
Park East Avenue, Shatin, New Territories, Hong Kong
www.salus-controls.eu SALUS Controls is a member of the Computime Group. Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change the specification, design, and materials of products listed in this brochure without prior notice.