Simply45 S45-1100 Unshielded Standard WE-SS 8P8C RJ45 Modular Instructions
- June 3, 2024
- Simply45
Table of Contents
Best Practice Termination Instructions
S45-1100 Unshielded Standard WE-SS 8P8C RJ45 Modular
- Bar45® uses a Hi/Lo stagger design and is made of a material that provides better signal isolation improving NEXT performance;
- On S45-1100, the Bar45® is located over the RJ45 pins. This allows the LAN cable to be inserted deeper into the Plug. This reduces the length of untwisted wires improving signal integrity and negating crosstalk interference.
For improved termination performance, please follow the step-by-step
instructions for terminating the S45-1100 RJ45 modular plugs.
STEP 1
If using Cat6 UTP cable, trim center spline/pair separator as close to the
cable jacket as possible without nicking any of the wire conductors.
STEP 2
Make sure each wire conductor is straight. We recommend using the Simply45
Adjustable LAN Cable Stripper (Part: S45-SO1BL/YL) that has a wire
straightener comb on the top.
STEP 3
Then straighten and align wires to correct alignment pattern (Type A or B).
The B Pattern is most commonly used today. Using angled flush cutter tool
(such as Simply45 part: S45-801), trim wire ends straight before inserting
into the load bar.
STEP 4
Insert the Pattern Aligned wires asshown above (B pattern shown)
WIRING CHART
STEP 5
Slide Bar45® down until it touches or comes close to the cable jacket.
STEP 6
Then trim wires flush with the load bar using the Angled Flush Cutter (part:
$45-801
(https://simply45.com/shop/tools/cutters/s45-801-simply45-premium-5-flush-
cutter-tool/)). Please be sure to trim wires properly. If wires are not
trimmed close to the load bar, the load bar will not set properly over the
Plug pins.
STEP 7
Insert the cable with the Bar45@ into the plug with the load bar over the
pins. (fig. 1). Notice in the picture (fig. 2) that the cable jacket should
come to the horizontal line underneath the plug (S45- 1100).
STEP 8
Insert the loaded plug into the Simply45 Crimper socket. Be sure that plug is
fully inserted. Then complete crimping cycle.