Simply45 S45-1710S 10G Rated RJ45 Ultra Slim Shielded Field Plug Instruction Manual
- June 3, 2024
- Simply45
Table of Contents
Simply45 S45-1710S 10G Rated RJ45 Ultra Slim Shielded Field Plug
S45-1710S
10G Rated RJ45 Field Plug – Ultra Slim Fully Shielded for Cat6/6a/7a Shielded LAN cables, Toolless, 1 Piece Design, Re-usable. ISO/IEC 11801, Class Fa, F, Ea, E, ANSI/TIA 568.2-D, PoE/PoH IEEE 802.3bt Type 1-4 Supports cable diameter: 6.0 – 9.0 mm
Cable Preparation
| TIA / EIA T568A| TIA / EIA T568B| INDUSTRIAL
---|---|---|---
White/Green Green| White/Orange Orange| Yellow Orange
White/Orange Orange| White/Green Green| White Blue
Blue White/Blue| Blue White/Blue|
White/Brown Brown| White/Brown Brown|
-
Slide metal cable gland with black nylon cable bushing onto the cable. Follow cable preparation as shown. Fan out all 4 twisted pairs and cut the conductors as shown.
Note:
a. Make sure nylon cable bushing is facing correctly as shown to the right.
b. Nylon cable bushing has slit to allow proper tightening during final stage of screwing the metal cable gland to the connector. Cable busing may be removed on cable OD >8mm.
-
Follow the color-coded wire pattern label and align each conductor into proper slot on wiring cap. Using flush cutter, trim wires flush with wiring cap.
-
Remove wiring label before placing wiring cap on connector.
![Remove wiring label before placing wiring
cap on connector](https://manuals.plus/wp-content/uploads/2022/11/2e3f.png)
-
Place wiring cap onto IDC terminal and press firmly down. Ensure drain wire or braiding is in contact with grounding clip. See illustration.
-
Make sure drain wire is not stuck between housing as you close plug cover firmly down. Screw on the cable gland with inserted bushing to complete installation.