SUPERLED SR-ZG9100A-S ZigBee In Wall Smart Switch User Manual
- June 3, 2024
- SUPERLED
Table of Contents
- SUPERLED SR-ZG9100A-S ZigBee In Wall Smart Switch
- Function introduction
- Main Features
- The switch operates under the following loads
- ZigBee Clusters the device supports are as follows: Input Clusters
- Operation
- TouchLink to a Zigbee Remote
- Find and Bind Mode
- Setup a Zigbee Network & Add Other Devices to the Network
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SUPERLED SR-ZG9100A-S ZigBee In Wall Smart Switch
Function introduction
Input Voltage | Output Voltage | Output Current | Size(LxWxH) |
---|
100-240VAC
|
100-240VAC
| Resistive load: max. 4.8A
Capacitive/Inductive load: max. 1.4A
|
45.5x45x20.3mm
- ZigBee in wall smart switch based on latest ZigBee 3.0 protocol
- 100-240VAC Wide Input and Output Voltage
- Supports resistive loads, capacitive loads or inductive loads
- 1 channel output, max. load up to 4.8A
- Input and Output with Screw Terminals, Safe and Reliable
- Enables to control ON/OFF of connected light source
- ZigBee end device that supports Touchlink commissioning
- Can directly pair to a compatible ZigBee remote via Touchlink without coordinator
- Supports self-forming zigbee network without coordinator and add other devices to the network
- Supports find and bind mode to bind a ZigBee remote
- Supports zigbee green power feature and can bind max. 20 zigbee green power remotes
- Compatible with universal ZigBee gateway products
- Mini Size, Easy to be Installed into a standard size wall box
- Radio Frequency : 2.4GHz
- Waterproof grade: IP20
Main Features
- Can operate under two-wire connection with no neutral lead or three-wire connection with neutral lead
- Soft start function,
- Works with various types of switches – momentary, toggle, three-way, etc.
- Active element: semiconductor electronic switch,
- To be installed in wall switch boxes of dimensions allowing for installation, conforming to provisions of applicable regulations,
- The Bypass is an extension unit.
The switch operates under the following loads
- Conventional incandescent and HV halogen light sources
- ELV halogen lamps (with electronic transformers)
- MLV halogen lamps (with ferromagnetic transformers)
- Compact fluorescent CFL tube lamps with electronic ballast
- Fluorescent tube lamps with electronic ballast
- Supported light sources (power factor > 0.5) with minimal power of 3W using the Bypass (depending on the type of load)
ZigBee Clusters the device supports are as follows: Input Clusters
- 0x0000: Basic
- 0x0003: Identify
- 0x0004: Groups
- 0x0005: Scenes
- 0x0006: On/off
- 0x0702: Simple Metering
- 0x0b05: Diagnostics
- 0x0b04: Electrical Measurement
Output Clusters
- 0x0019: OTA
Safety & Warnings
- DO NOT install with power applied to device.
- DO NOT expose the device to moisture.
Operation
- .Do wiring according to connection diagram correctly.
- .This ZigBee device is a wireless receiver that communicates with a variety of ZigBee compatible systems. This receiver receives and is controlled by wireless radio signals from the compatible ZigBee system.
- Zigbee Network Pairing through Coordinator or Hub (Added to a Zigbee Network)
Step 1 : Remove the device from previous zigbee network if it has already
been added to, otherwise pairing will fail. Please refer to the part “Factory
Reset Manually”.
Step 2: From your ZigBee Controller or hub interface, choose to add
lighting device and enter Pairing mode as instructed by the
controller.
TouchLink to a Zigbee Remote
Step 1: Method 1: Short press “Reset” button (or re-power on the device) 4 times to start Touchlink commissioning immediately, 180S timeout, repeat the operation. Method 2: Re-power on the device, Touchlink commissioning will start after 15S if it’s not added to a zigbee network, 165S timeout. Or start immediately if it’s already added to a network, 180S timeout. Once timeout, repeat the operation.
-
Note: Directly TouchLink (both not added to a ZigBee network), each device can link with 1 remote.
-
TouchLink after both added to a ZigBee network, each device can link with max. 30 remotes.
-
For Hue Bridge & Amazon Echo Plus, add remote and device to network first then TouchLink.
-
After TouchLink, the device can be controlled by the linked remotes.
-
Removed from a Zigbee Network through Coordinator or Hub Interface
-
Factory Reset Manually
-
Note If the device is already at factory default setting, there is no indication when factory reset again .
-
All configuration parameters will be reset after the device is reset or removed from the network
-
Factory Reset through a Zigbee Remote
**Note** : Make sure the device already added to a network, the remote added to the same one or not added to any network. .
Find and Bind Mode
Note: Make sure the device and remote already added to the same zigbee network.
- Learning to a Zigbee Green Power Remote
Note: Each device can learn to max. 20 zigbee green power remotes
Delete Learning to a Zigbee Green Power Remote
Setup a Zigbee Network & Add Other Devices to the Network
Wiring Diagram Compatible load types and recommended values of power for supported loads:
Supported load types | 100-240V~ |
---|---|
Resistive loads |
Conventional incandescent and halogen light sources
| 20-1000W @ 230V
20-500W @ 110V
| Capacitive loads
Fluorescent tube lamp
(compact / with electronic ballast), electronic transformer, LED
| Using Bypass:
3-300W @ 230V
3-150W @ 110V
| No Bypass Used: 20-300W @ 230V
20-150W @ 110V
|
Inductive loads
Ferromagnetic transformers
|
20-300W @ 230V
20-150W @ 110V
Notes for the diagrams:
- L – terminal for live lead
- N – terminal for neutral lead
- Out – output terminal of the switch (controlling connected light source)
- S1 – terminal for switch (has the option of entering the device in inclusion/exclusion mode) COM – terminal for grounding to the switch connected to the switch
Supported external switch types (should be configured by factory setting):
-
Push switch (default factory setting)
-
Normal On/Off switch (should be configured by factory setting upon request)
-
2-Wire Connection With No Neutral Lead With PUSH LV
NOTE: Switch connected to the S1 terminal activates the basic
functionality of the dimmer (turning the light on/off).
The Bypass is a device designed to work with the micro smart dimmer. It should
be used in case of connecting LED bulbs or energy saving compact fluorescent
lamps. The Bypass prevents flickering of the LED lights and glowing of the
turned off compact fluorescent lamps. In the case of 2-wire connection, the
Bypass allows to reduce minimum power of load required by the dimmer for
correct operation. The Bypass provides powering of the dimmer in case of
controlling the low loads of minimum power down to 3W (for cosφ>0.5).
3-Wire Connection With Neutral Lead With PUSH LV
NOTE: Switch connected to the S1 terminal activates the basic functionality of the dimmer (turning the light on/off).
Multiple Momentary or Push Switches Connection With PUSH LV
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>