APC PT-5000 and PT-9000 Heavy Duty 24V System Actuator Installation Guide
- June 3, 2024
- APC
Table of Contents
- APC PT-5000 and PT-9000 Heavy Duty 24V System Actuator
- Specifications
- Preliminary Checks
- Important Safety Information
- Tools Required
- Motor Stroke and Dimensions
- Post installation methods
- Gate Stop Installation
- Wiring
- Control Board Connection
- APC WARRANTY
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
APC PT-5000 and PT-9000 Heavy Duty 24V System Actuator
Specifications
The above specifications
are based on perfect free flowing installations on non-cladded or covered gate
using ball bearing hinges.
*Larger sized gates may require an electric lock
Preliminary Checks
To ensure safety and an efficient automation make sure the following requirements are met:
- The gate structure must be suitable for automation.
- Make sure that the gate leafs move properly and uniformly without any irregular friction during their entire travel.
- The gates hinges must be in good condition with no bitting, no rust and must be well greased.
- The gates should be able to be freely opened and closed before installing the gates automation system.
- It is strongly suggested to have a gate stop installed for the closed position.
Important Safety Information
Installer and owners should observe the following:
- Make sure that there is sufficient space for the gate(s) to swing open fully to the desired opening angle.
- The control Panel Box must be installed in the area within 9 meters maximum cable distance from motor and cannot be damaged.
- Do not change with parts or components not supplied by the manufacturer, this includes sensors, buttons, solar panels, transformers and any component not listed in the compatibility list.
- Make sure all wiring works are correct and in good condition before connecting the battery, solar panel or transformer to the control panel.
- Turn off the power and disconnect the battery when doing any maintenance.
- Ensure the control panel box is free from water leakage to avoid short circuiting of the control panel.
- Do not supply mains power directly to the motor, control box or any accessories.
- Do not install the operating system if in doubt. Contact the manufacturer.
- Do not cross the gate while it is operating, Safety sensors are only to prevent accidents or injuries.
- Keep the remote controls in safe place and away from children.
Before beginning installation the manual should be read thoroughly concerning
all aspects of the installation including all precautions and safety
information.
Proper steps should be taken to ensure efficient and safe installation for
vehicles, property and persons within the operators working radius.
The system is fitted with an over current sensing feature to assist in
preventing damages, injuries and death. All precautions must be taken by the
installer that adjustments are set correct based on the gates weight, height
and length. The system sensitivity should be set to allow consistent operation
of the gates under normal operating conditions. This does not include
operating against wind. The system may not detect (Over current sense) against
light loads such as small object, young children and animals. It is the
operators duty to ensure that the area is clear prior to operation. Photo
sensors or Reflective sensors should always be installed to assist in accident
or death prevention. Rubber edging should be installed onto the gates to
assist in dampening any accidents or damages. You agree to install this
product following any and all safety requirements listed in this manual or
required under local, state or national regulations. APC Australia, its
distributors, stockist or sellers are not liable for any direct, indirect,
incidental, special or consequentional damages or loss of profit wether based
in contract or any other legal theory during the course of warranty or
afterwards. If you do not feel capable of properly installing the operator
based on the above information or otherwise do not proceed.
Tools Required
Motor Stroke and Dimensions
UNDER NO CIRCUMSTANCES SHOULD THE EXPANDED STROKE OF THE MOTOR BE USED AS A
LIMIT Clutch Override
In case of an emergency or requirements during installation the gate can be
moved open and close by hand operation if the clutch is disengaged. To
disengage the clutch follow the procedure below. To Disengage
- Open the dust cover.
- Insert the allen key and turn by 90° clockwise.
To Engage
- Insert the allen key and turn by 90° counter-clockwise.
- Close the dust cover.
Post installation methods
Optional APC-FGB2532 Farm Gate Bracket System
Gate Stop Installation
Before beginning the installation of the gate motors a physical gate stop must be installed at the closed position. For Single gate systems the gate stop can be installed in two different methods.
- On the driveway itself at the furthest point from the hinge as illustrated in the diagram below (Fig 1).
- On the post that the gate will close too (Fig 2).
NOTE: For Push to Open Installations both the open and close stops are required
For Double gate systems the gate stop must be installed in the center of the
driveway stopping both gates (Fig 3).
When installing on the driveway itself it is recommended to use a rubber floor
stop to prevent damage to vehicle entering and exiting.
When installing on the post for single gate installations a 90° angle can be
used with a rubber padding to dampen or soften the close and prevent damage to
the gate.
UNDER NO CIRCUMSTANCES SHOULD THE EXPANDED STROKE OF THE MOTOR BE USED AS A LIMIT
Pull to Open Installation
Repeat the above steps for the second gate motor if applicable
Push to Open Installation
Repeat the above steps for the second gate motor if applicable
Wiring
Control Board Connection
Pull-To-Open
- Motor will be pulling the gate towards it for OPENING.
- Gates (Left and Right) are based on observation of the gates from the same side the motors will be installed on.
Push-To-Open
- Motor will be pulling the gate towards it for CLOSING.
- Gates (Left and Right) are based on observation of the gates from the same side the motors will be installed on.
Please follow the above motor connections then proceed to the control panel manual.
APC WARRANTY
- APC warrants the original purchasers or the APC gate(s) opening system for a period of twelve months from the date of purchase (not installation), the product shall be free of defects in materials and workmanship under normal use.
- During the warranty period, APC shall, as its option, repair or replace any defective product upon return of the product to its factory, at no charge for labour and materials.
- Any replacement and/or repaired parts are warranted for the remainder of the original warranty,
- The original owner must promptly notify APC in writing that there is defect in material or workmanship, such written notice must be received in all events prior to expiration of the warranty.
International Warranty
APC shall not be responsible for any freight fees, taxes or customs fees.
Warranty Procedure
To obtain service under this warranty, AND AFTER CONTACTING APC, please return
the item(s) in question to the point of purchase.
All authorized distributors and dealers have a warranty program, anyone
returning goods to APC must first obtain an authorization number. APC will not
accept any shipment for which prior authorization has not been used.
Conditions to Void Warranty
This warranty applies only to defects in pairs and workmanship relating to
normal use. It does not cover:
- Damage incurred in shipping or handling
- Damage caused by disaster such as fire, flood, wind, earthquake or lightning
- D amage due to causes beyond the control of APC such as excessive voltage, mechanical shock or water damage
- Damage caused by unauthorized attachment, alterations, modifications, or foreign objects.
- Damage caused by peripherals (unless such peripherals were supplied by APC)
- Defects caused by failure to provide a suitable installation environment for the products
- Damage caused by usage of the products for purpose other than those for which it was designed.
- Damage from improper maintenance
- Damage arising out of any other abuse, mishandling, and improper application of the products.
Under no circumstances shall APC be liable for any special, incidental, or consequential damages based upon breach of warranty, breach of contract, negligence, strict liability, or any other legal theory. Such damages include, loss of profits, loss of the product or any associated equipment, cost of capital, cost of substitute or replacement equipment, facilities or services, down time, purchaser’s time, the claims of third parties, including customers, and injury to property.
Disclaimer of Warranties
This warranty contains the entire warranty and shall be in lieu of any and all
other warranties, whether expressed or implied (including all implied
warranties of merchantability or fitness for a particular purpose). And of all
other obligations or purporting to act on its behalf to modify or to change
this warranty, nor to assume for it any other warranty or liability concerning
this product.
Out of Warranty Repairs
- APC will at its option repair or replace out-of-warranty products which are returned to its factory according to the following conditions. Anyone returning goods to APC must first obtain an authorization number.
- APC will not accept any shipment whatsoever for which prior authorization has not been obtained. Products which APC determines to be repairable will be repaired and returned. A set fee which APC has been predetermined and which may be revised from time to time will be charged for each unit repaired.
- Products which APC determines not repairable will be replaced by the nearest equivalent product available at that time. The current market price for the replacement product will be charged for each replacement unit.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>