DENNERLE 154.0228.01 Trocal LED Control Instruction Manual

June 13, 2024
DENNERLE

DENNERLE 154.0228.01 Trocal LED Control

IMPORTANT INFORMATION

Congratulations on purchasing this high-end Dennerle product. We wish you years of enjoyment and pleasure with your aquarium!

  • Pleaseread all instructionscarefully beforeturning theequipmenton. Savetheseinstructionsfor futurereference.
  • Please read these instructions in full before connecting or setting the device. Once you understand the basic operating concept, it will be easier for you to quickly
    and appropriately set the Dennerle Trocal LED Control (from here on referred to simply as LED Control).

Safety notes

  • The device may only be operated with the corresponding Dennerle components (power supply, lights). Take note of the appropriate operating instructions and the safety notes for the peripheral devices.
  • Unplug the device before performing any maintenance or installing the light.
  • Only for direct current 12-24 V
  • The maximum current-carrying capacity per output is 2.5 A and must not be exceeded.
  • For indoor use only.
  • Always disconnect all equipment in the water from the power supply before reaching into the aquarium.
  • The mains plug must be accessible at all times after installing the device.
  • Cables leading from the aquarium must be fitted with a drip loop so that any water running down cannot reach the equipment or the mains socket.
  • If a cable or the mains adapter becomes damaged, then the device must no longer be used. Damaged cables or mains adapters must be replaced. Only genuine Dennerle replacement parts may be used.Contact your specialist retailer or DennerleCustomerService.
  • This equipment is not intended to be used by persons (including children) with limited physical, sensory or mental capacity, lack of experience, and/or lack of knowledge, unless said persons are supervised for their own safety by another responsible person or are given instructions by this person on how to use the equipment.Children must be supervised to ensure that they do not play with the equipment.
  • Do notexposeorcoverLED Controland mainsadapter;alwaysensurea good levelofcooling.
  • The device must not be mounted on or in thecover frame.
  • TheLED control must be mounted outsideof the wetarea.
  •  This product must not be disposed of in normal household waste, and should be disposed of at your local refuse centre.

A Function keys, connections and components

Function keys, connections and components

  1. Graphics display: Basic setting displays: Date, time, current illumination intensity in %, moon phase

  2. LED: lights green during saving test or when the PCis connected to the socket position no. **10**

  3. Cursor keys::
    Go up a menu level or increase an entry value
    Go down a menu level or reduce an entry value
    Move right
    Move left

  4. ❎ Escape (back key) or cancel an action

  5. Return (confirm) or continue

  6. Input for mains adapter for light 1

  7. Input for mains adapter for light 2

  8. Output for light 1

  9. Output for light 2

  10. USB connection to upload software updates or to programme illumination curves via PC.

A Connection the lights

Connect the:

  1. Trocal LED 1 with output no. 8

  2. Trocal LED 2 with output no. 9 (option for 2 lights)

  3. the LED Connect cable no. B with input no. 6

  4. the other end of LED Connect cable (at input no. 6 ) with the corresponding mains adapter for the Trocal LED no. 1

  5. a second LED Connect cable (accessory item 5549) with the input no. 7 (option for 2 lights)

  6. the other end of LED Connect cable (at the input no. 7 ) with the corresponding mains adapter for the Trocal LED no. 2
    Caution! When operating Trocal LEDs with different power on one LED Control, under no circumstances should the power adapters be swapped.

  7. the power adapters each with a mains socket.

Connection to PC:

To carry out software updates or to programme via PCsoftware.

  1. Connect the LED Connect cable no. B with input no. 6
  2. Connect the other end of LED Connect cable (at the input no. 6) with the corresponding mains adapter for the Trocal LED no. 1
  3. Plug the mains adapter into a main socket
  4. Using the USB cable no. C connect it to your PC
  5. Open the program GHLControlCenter on your PC(see current advice at www.dennerle.com)
  6. With the help of the GHLControlCenter, you will now be able to adjust the settings on the LED Control

Settings/programming

Important

  • The menu structure can be accessed by pressing any cursor key information or the enter key
  • LED control is factory-set to English. In the menu, first navigate to Extras language Select your language Confirm the Save now ? command with yes.

Clock

Time
  • Navigate to the desired location using the key or and set the current time using the keys or
  • Confirm with the key
Date
  • Navigate to the desired location using the key or and set the current time using the keys or
  • Confirm with the key
Adjustment MEZ-MESZ

(Greenwich mean time – British summer time)

  • Summer time/winter time needs to be set manually. In addition, an adjustment period of 1-14 days can be set.
    o Set number of days with keys or
    o Confirm with the key

  • Confirm the „save now?“ query
    o with yes The time and date have been updated.

  • Confirm the “Set int. time” query
    o with yes The internal clock will immediately be set to the new time.
    When setting thetimein thefirst instance, thisshould be confirmed with yes
    o When confirming with no The internal clock will be adjusted within the set number of days as above under Adjustment MEZ-MESZ

Example When setting 10 days, this will result in 60:10 = 6 minutes per day.
If you would like a graduated adjustment when changing from GMT to BST (or vice versa) the update internal time query must be confirmed with no Note Two clocks run in the LED Control. One clock displays the actual („our“) time which can also be seen on the display. The device also operates a second (internal) clock which controls the automatic processes such as dimming. Both clocks function in the usual way except when setting the actual time (e.g. switching between winter time/summer time). In this case the internal clock is not adjusted immediately but within the set number of days so long as the “Set int. time” query has been confirmed with no.

Illumination

LED Control can control up to 2 Trocal LED lights each with 2 separate channels (i.e. a total of 4 illumination channels) independently of one another.
Note The progression of each channel can be individually set.
The Trocal freshwater LED models each have two channels.
Channel 1 is the warmer lighting colour and channel 2 is the colder lighting colour. This makes it possible to change the lighting colour throughout the day.
The Trocal Marinus LED models each have two channels.
Channel 1 has the white LEDs and channel 2 has the blue LEDs. This makes it possible to achieve effects such as moonlight or to adapt the ratio of blue to white depending on the needs of the animals inside.

Illumination run
  • “Channel to edit” query.Set the desired channel using keys ↑ or ↓
    o Confirm with key

  • “Channel active” query.
    o no Channel is deactivated
    o yes Query “Number of dimm-points” (4-8)Set with keys ↑ or ↓ desired no.Confirm with the key

  • Programming the dim-points
    o Time – at this time, the light should have the level of brightness that is subsequently set
    o Light intensity (0% – 100%) – brightness of the light at this time
    o Continue with

  • Select simulation “Select simul.”
    o Using keys or moon phase simulation can be switched on or off for this channel
    o Confirm with the key
    Note The brightness operation between the individual times is automati cally calculated.

Shift curves

This function conveniently allows entire illumination curves to be delayed.

  • Selecting or deselecting the curve to be delayed Navigate with the keys ↑ or ↓ at the desired channel and select using keys ← or → whether this curve should be delayed
  • Confirm with the key
  • “Shift by” query Set the time in minutes by which the previously selected illumination curves should be delayed
  • Confirm with the key
    Note LED Control now automatically re-calculates all times in the selected dim curves and saves these under 2.1. The delaying process can be repeated as many times as desired or cancelled at the corresponding setting.

Note LED Control now automatically re-calculates all times in the selected dim curves and saves these under 2.1. The delaying process can be repeated as many times as desired or cancelled at the corresponding setting.

Manual illumination “Manu. illuminat.”

This menu is primarily intended for testing and diagnosis purposes.

  • Select the channel where you would like to change the brightness using the keys ← or →
  • Using the keys   or ↓ you can make the selected channel brighter or darker
  • The manual illumination can be completed with
  • After completing, the settings are not retained
Moon

In this menu it is possible to set in which time period the moon-phase simulation is activated. The moon-phase simulation does not „create“ moonlight, but simply changes the curve programmed under 2.1 as moonlight.

  • Simulation start Enter the start time for the moon-phase simulation
  • Simulation end Enter the end time for the moon-phase simulation

The start and end times of the moon-phase simulation must be set such that they include the time period for the nightly moonlight of the appropriate channel. If, for example, the channel is programmed such that it lights up from 22:00 to 07:00 (previously set under 2.1 , see example 2D ), the moon-phase simulation should also be set from 22:00 to 07:00.
Moon

The moon phases in the LED Control are calculated based on the date such that the full moon and new moon are always in line with the actual (real) phases of the moon with a maximum discrepancy of one day.
Please note that the moon-phase simulation must be active in the desired illumination channels; see 2.1. (Illumination run) The following will now occur for the active illumination channels within the set time: The brightness that the illumination channel would have had according to its programmed curve will be multiplied by the current moon-phase brightness. This means that during this time frame, the actual brightness will be reduced corresponding to the natural phase of the moon.
Example In the case of a natural moon brightness on this day of 50% and a moonlight brightness pre programmed under 2.1 of 20% this will result in an actual channel brightness of 50% x 20% = 10%
Note When selecting moon-phase simulation OFF the moonlight under 2.1 will mean full moon every night.
Recommen- With Trocal LED freshwater we recommend using only channel 2 dation (colder light colour) and using a light intensity which is close to nature, i.e. low intensity

Time lapse

The time lapse is intended for testing and presentation purposes. Using this function it is possible to view the set illumination programme in high speed. There is a manual time lapse function (shown in the top right by „M“) and an automatic time lapse function (shown by „A“). It is possible to switch between both modes by pressing In the manual time lapse mode it is possible to set the point in time and the LED Control shows the illumination programmed for this time. For this use the 4 cursor keys.

During automatic time lapse, the time to be simulated will be continuously counted up. It is possible to set the speed of the time lapse. Set the duration in seconds required for the simulation of 24 hours. For this use the 4 cursor keys.  stops the time lapse.

Acclimatisation “Acclimation”

The acclimatisation function offers a simple and convenient option for automatically changing the brightness of the illumination over several days. This is useful, for instance, when plants are to acclimatise to a new illumination or if fish/corals are to be inserted for the first time.
Start Date the acclimatisation begins immediately and continues until the start date set under Start brightness Start brightness “Start Light intensity” all channels will be multiplied with this value at the start of the acclimatisation End date the acclimatisation ends on this day End brightness “End Light intensity” all channels will be multiplied with this value at the end of the acclimatisation During acclimatisation, a dim factor is calculated daily. The individual illumination curves are converted using this factor.
Example:Start on 01/01/2016 with 50%, end on 03/01/2016 with 100% The illumination is then immediately operated at 50% of the usually set brightness until 01/01/2016, on the second day with 75% and on the last day 100%.

Tips:

  • This function is ideal for converting an aquarium with a lighting tube to LED technology. Depending on difference in output between the existing and new system, we recommend a „ graduated adjustment“ over 4-6 weeks.
  • This function enables the convenient illumination of all 4 channels to be simultaneously reduced by a certain percentage, which can be very helpful in combating algae.

Extras

Info & Support

In this menu point, after a certain period of time, or after pressing a key information will be displayed in succession regarding the software version, model and our website.

Display

Here it is possible to set which current values are shown on the display during normal operation. If several items are selected, these will be shown in rotation.

  • Display durati the display will show continuously for this length of time until the next value is shown
  • Select channels here it is possible to select which illumination channels should be shown

Recommended settings If a Trocal LED is connected, place a tick next to illumination 1 settings and 2, select using keys or If two Trocal LEDs are connected, place a tick next to illumination 1 to 4, select using keys or ←.

  • Time and date it is possible to set whether the current time and date are never shown, always shown or shown in rotation “rotate”.
  • Display day Setting the display brightness from 0-100% (e.g. during illumination phase)
  • Display night Setting the display brightness from 0-100% (e.g. outside of the illumination phase)
  • Display night start Setting the time from when the display brightness should be reduced from the the previously set value in „display night“
  • Display night end Setting the time from when the display brightness should be increased from the the previously set value in „display day“
Language

Here it is possible to set the language that the LED Control text is displayed in.
Caution LED control is factory-set to English. In the menu, first navigate to Extras language Select your language Confirm the Save now? command by pressing yes.

System

This is where all system functions and settings such as the hardware configuration is summarised.

Factory settings

After selecting this function, you will be asked whether you would like to revert to the factory settings. If you confirm with yes, all settings will return to their initial state!

PIN

A personal identification number (PIN) is provided to protected the device against changes to settings by unauthorised persons. The factory PIN is set to 0000. When the PIN is set to 0000, all changes can be made without entering a PIN. Once the PIN differs from 0000, the PIN needs to be entered before each setting. This also applies for changing the PIN.
If you have Switch off the device (remove plug from power supply) and switch forgotten on again (re-insert the plug into the power supply). Immediately the PIN afterwards, while the status and greeting display is visible, press and simultaneously. You will then be asked Delete PIN?
After confirming with yes the PIN will return to the factory setting (0000 – deactivated).

Troubleshooting

Errors Possible causes/remedy
Lights always have 100% brightness and won‘t dim. Inputs and outputs

switched/Pay attention to the assignment of power supplies and lights and where necessary correct.
LED control is working but the second light is not lighting up.| Only one power supply is connected/ Connect the second light‘s power supply
Lights or individual channels do not have the level of brightness programmed into the illumination programme| Checking whether moon-phase simulation is active or whether start and end times are correctly programmed. See point 2.4

Replacement parts and accessories

See: www.dennerle.com

MANUFACTURER’S REPRESENTATIONS AND WARRANTIES

Dennerle USA, Inc.
350 Fifth Avenue Suite 5220 New York, NY 10118 USA Website: http://dennerle.com

These Representations and Warranties are applicable to all customers (the “Customers” and each, individually, a “Customer”) purchasing products (the “Products”) manufactured by Dennerle USA, Inc. (the “Company”).

  1. Warranty and Limitations:
    1.1. Company warrants solely to the original purchaser of the Products that for the Warranty Period (as defined  below), the Products will be free fromdefects in materials and workmanship under normal use, and will conform to Company’s published specifications of the Products. Notwithstanding the foregoing, Company retains its right to deviate from its published specifications due to the latest innovations and improvements in function and design of the Products.
    1.2. The foregoing warranty is subject to the proper installation, maintenance, storage, transportation and use of the Products, and does not include defects due to normal wear and tear or deterioration.
    1.3. Customer shall immediately, but in any event no later than twenty- four (24) hours following delivery of the Product, inspect the Products for conformity and visible defects. Customer shall give Company immediate written notice of any non-conformities or visible defects regarding the Products.
    In the event that Customer fails to provide the Company within twenty-four hours (24) hours following delivery or installation of the Products with notice of any non-conformities or visible defects, any warranty claims in this regard shall be deemed waived.
    1.4. Customer shall immediately notify Company in writing of any other defects of the Products and return such defective Product. Company’s sole obligation under the foregoing warranty is, at Company’s option, to replace or exchange the defective Product or issue a merchandise credit for the defective Product. Any replaced or exchanged Products shall be subject to the warranty set forth in 1.1., following their replacement or exchange. If Company has received notification from Customer, and no defects of the Product could be discovered, Customer shall bear the costs that Company incurred as a result of the notice. It shall be in Company’s sole discretion to determine if the Product has a defect.
    1.5. With respect to orders made to custom, any defects of the Products caused by Customer’s specifications are excluded from the warranty set forth in 1.1.
    1.6. Company also makes no warranty that the Products manufactured under an order made to custom do not infringe the intellectual property or other proprietary rights of any third party and Customer is solely responsible for assuring that such Products do not so infringe.
    1.7. The “Warranty Period” begins on the date of delivery of the Product to Customer, and continues to be in effect for six (6) months.
    1.8. Company does not authorize any person or party to assume or create for it any other obligation or liability in connection with the Products except as set forth herein.
    All correspondence requests and notices shall be directed to:
    Dennerle USA, Inc. 350 Fifth Avenue Suite 5220 New York, NY 10118 USA
    Dennerle product distribution and warranty shall be directed to: TransWorld Aquatic Enterprises 3730 W. century Blvd., Unit # 3 Inglewood, CA 90303 USA
    Customer Support: 877-374-9981
    Monday to Friday 9am – 4pm (Pacific Time) Email: support@jbjlighting.com
    1.9. THE WARRANTY SET FORTH IN SECTION 1.1 IS MADE IN LIEU OF ALL OTHER WARRANTIES (WHETHER EXPRESS OR IMPLIED), RIGHTS OR CONDITIONS, AND CUSTOMER ACKNOWLEDGES THAT EXCEPT FOR SUCH LIMITED WARRANTY, THE PRODUCTS ARE PROVIDED “AS IS.” COMPANY SPECIFICALLY DISCLAIMS, WITHOUT LIMITATION, ALL OTHERWARRANTIES, EXPRESS OR IMPLIED, OF ANY KIND, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, NON-INFRINGEMENT, AND THOSE WARRANTIES ARISING FROM A COURSE OF PERFORMANCE, A COURSE OF DEALING OR TRADE USAGE.

  2. Limitation of Liability:
    2.1. IN NO EVENT SHALL COMPANY BE LIABLE FOR ANY INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO, DAMAGES FOR LOSS OF PROFITS, REVENUE, GOODWILL OR USE, INCURRED BY CUSTOMER OR ANY THIRD PARTY, WHETHER IN AN ACTION IN CONTRACT, TORT, STRICT LIABILITY, OR IMPOSED BY STATUTE, OR OTHERWISE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. COMPANY’S LIABILITY FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THIS AGREEMENT SHALL IN NO EVENT EXCEED THE PURCHASE PRICE OF THE PRODUCTS. IT IS AGREED AND ACKNOWLEDGED THAT THE PROVISIONS OF THIS AGREEMENT ALLOCATE THE RISKS BETWEEN COMPANY AND CUSTOMER, THAT COMPANY’S PRICING REFLECTS THIS ALLOCATION OF RISK, AND BUT FOR THIS ALLOCATION AND LIMITATION OF LIABILITY, COMPANY WOULD NOT HAVE ENTERED INTO THIS AGREEMENT.
    2.2. IN JURISDICTIONS THAT LIMIT THE SCOPE OF OR PRECLUDE LIMITATIONS OR EXCLUSION OF REMEDIES OR DAMAGES, OR OF LIABILITY, SUCH AS LIABILITY FOR GROSS NEGLIGENCE OR WILLFUL MISCONDUCT OR DO NOT ALLOW  IMPLIED WARRANTIES TO BE EXCLUDED, THE LIMITATIONOR EXCLUSION OF WARRANTIES, REMEDIES, DAMAGES OR LIABILITY SET FORTH ABOVE ARE INTENDED TO APPLY TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW. CUSTOMER MAY ALSO HAVE OTHER RIGHTS THAT VARY BY STATE, COUNTRY OR OTHER JURISDICTION.
    This warranty is limited to the repair or replacement of the product at the discretion of the manufacturer and distributor. This warranty does not cover personal injury, property loss, including livestock or damage (direct or incidental, or consequential) arising out of use of this product.

Symbol.png

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals