CPAT IRX1 Flex Head End Ingress Receiver User Manual
- June 3, 2024
- CPAT
Table of Contents
IRX1 Flex Head End Ingress Receiver
User Manual
IRX1 Flex Head End Ingress Receiver
This document provides information proprietary to Effigis and cannot be used
or disclosed without Effigis’ written authorization.
Effigis reserves the right to make changes without notice. Changes affecting
the operation of any component in this manual will be reflected in a
subsequent revision. Effigis assumes no responsibility for any omissions or
errors that may appear in this document or for any damages that may result
from the use of information contained herein.
IRX1 User Manual
First edition (v1.0): June 2012
Second edition (v1.1): July 2012
Third edition (v1.2): October 2012
Fourth edition (v1.3): February 2013
Fifth edition (v1.4): September 2014
Part No. 100-00006-001
Published by:
Effigis
4101 Molson St., Suite 400
Montréal, Québec
CANADA H1Y 3L1
Telephone: + 1 514 495-0018
Toll-free (North America): + 1 888 495-6577
Fax: + 1 514 495-4191
Copyright © 2014 Effigis All rights reserved
General Information
1.1 About this Manual
This manual describes the components, installation and operation of the CPAT
FLEX IRX1 unit.
You will find important safety information in this manual. We strongly
recommend that all users read this manual. Use of this product other than for
its intended application may compromise the unit’s safety features.
1.2 Certifications
This section describes the certifications the IRX1 complies with.
1.2.1 Tests Specifications
FCC 47 CFR Part 15, Subpart B – Verification
ICES-003/NMB-003 Issue 4 February 2004
Electrical equipment for measurement, control and laboratory use – EMC
requirements –
Part 1: Generic requirements.
1.2.2 Compliance
This Class A digital apparatus complies with Canadian ICES-003/NMB-003.
This Class A digital apparatus also complies with European EN61326-1: 2006.
1.2.3 Note
This device may not cause harmful interference.
This device must accept any interference received, including interference that
may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy, and if it
is not installed and used in accordance with the instruction manual, it may
cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference, in
which case the user will be required to correct the interference at his owns
expense.
Modifications: Any modifications made to this device that are not
approved by Effigis Geo- Solutions Inc., may void the authority granted to the
user by the FCC to operate this equipment.
1.3 Technical Support
Effigis Technical Support Service is available from Monday through Friday from
9:00 AM to 5:00 PM Eastern Time.
Toll free from U.S. and Canada: + 1 888 495-6577
International: + 1 514 495-0018
Fax questions anytime to: + 1 514 495-4191
cpat@effigis.com
1.4 Calibration
Your IRX1 unit has been calibrated and tested in the factory, and does not
need further calibration before use.
However, if the unit suffers damage and needs repair, it is recommended that
the unit be return to an authorized Effigis service center there it will be
properly re-calibrated. As well, if your company requires regular calibration
of all equipment, or requires a calibration certificate for the
IRX1, a calibration service is available through Effigis.
For more information on calibration services, please contact your Effigis
representative.
1.5 Explanation of Symbols Used
The following symbols are used in this Manual:
Symbol Explanation
Caution. Indicates that operations or procedures, if carried out without
caution, may cause personalinjury or damage to the unit.
Note. Indicates additional information about the product.
1.6 Effigis Website
Effigis’ website contains product specifications, information, press releases,
brochure download and Frequently Asked Questions
(FAQs). Please visit our website at: http://effigis.com
System Components
The IRX1 is the receiver part of a find-and-fix ingress solution for broadband
operators. It monitors signal transmitted over the air via the ITX1 that comes
thru the cable network. The IRX1 RF entries are feed from the head end tests
point return. Global operating status is displayed on the LCD located on the
front panel of the unit. Once installed, it requires no further intervention
to monitor and transmit results through CPAT web interface.
This section describes the IRX1 unit in detail including its accessories, and
helps you get started by explaining the features, the powering and data
interface on the unit.
2.1 Initial Verification
Your IRX1 unit is calibrated, and ready to use right out of the box. Upon
reception, visually inspect each item for any damage that may have occurred
during shipping. If you see any signs of physical damage, please contact
Effigis:
- Callers from the U.S. and Canada can dial + 1 888 495-6577 (toll-free number).
- International callers can dial + 1 514 495-0018.
Make sure no items are missing. Your package should contain all the standard items as well as any accessories you may have ordered. If you ordered the IRX1 – Head-end Based Return Band Receiver kit, the following items are included:
- IRX1 rack mount unit.
- 2 Rack mount right angle brackets.
- AC/DC adapter.
- User manual.
If
any of the standard accessories are lost or damaged, you can order a
replacement for the IRX1. Please quote the following part numbers when placing
an order:
Part No. | Accessory Description |
---|---|
(1) 110-00003-001 | AC/DC adapter |
(2) 100-00006-001 | IRX1 Operation Manual (This guide) |
To place an order, please call Effigis at + 1 888 495-6577 or + 1 514
495-0018
Installation
3.1 Rack Mounts Installation
CAUTION!
Leave space for front, back and lateral ventilation. 3.2 Connecting RF
Entries
The RF entries are connected directly the return nodes tap. The maximum RF
level entry is 40 dBmV per RF input. This is however the total RF level
between 5 MHz and 45 MHz. It is recommended to have a minimum of pads without
having the frequency band (5-45 MHz) power to go over 40 dBmV per RF input.
If you want to combine nodes on the same RF entry, be aware that the IRX1
sensitivity performance might be affected: since the IRX1 tries to detect
ingress, the incoming digital ingress signal is not always at the same level.
Also, the measured value does not take into account the pads.
CAUTION!
Levels over this limit can distort the signal or damage the receiver’s RF
frontend. Contact the CPAT technical support for more information.
3.3 Electrical Installation
The AC/DC adapter is supplied with the equipment. It is compatible with
110V/220V voltages and 50/60 Hz power distribution networks.
3.4 Internet Connection
The IRX1- needs an access to the internet to transmit received measurement
level to the CPAT servers and for automatic firmware update. Transfers vary
from less than a 1MBytes to a maximum of ~7Mbytes per day depending of the
intensity of the patrolling, the number of ITX1 in the sector and the number
of failure on the network.
The IPv4 address is acquired with the use of DHCP. If no DHCP server is
present on the network, the system will not be able to transmit data over the
network.
Make sure that the unit has an access to the Internet and that the FTP port 21
is open. Without this access, it won’t be able to communicate with our FTP and
“Realtime Ingress Monitor” servers (RIM).
NOTE
It is recommended that you install the IRX1 behind a firewall, or a router
with an integrated firewall, to avoid malicious or unauthorized connections
(Ref: http://www.kbcert.orgvulsid107886).
Setup
Make sure that the unit has an access to the Internet and that the FTP TCP
port 21, remote assistance TCP port 26 and RIM UDP port 20000 is open
(outgoing). Without those rules, it won’t be able to communicate with our FTP
and “Realtime Ingress Monitor” servers (RIM) and we won’t be able to access
the IRX1 for remote assistance.
If you want to combine nodes on the same RF entry, be aware that the IRX1
sensitivity performance might be affected: since the IRX1 tries to detect
ingress, the incoming digital ingress signal is not always at the same level.
Also, the measured value does not take into account the pads.
System Operation
5.1 Power On
To power on the unit, make sure that the power cable is properly connected to
a power bar (recommended) and into the IRX1- then press the ON/OFF button on
the front panel for 3 seconds then release it. You should see both lights on
the front panel turn green then the PWR-light will turns red.
5.2 LED and LCD Information
The two front LEDs indicates the status of the unit. PWR (power):
- When RED solid, the system is booting (takes about 1 minute to boot).
- When GREEN solid, the system is powered up and booted. DIAG (diagnostic):
- When OFF, the system is working fine.
- When flashing GREEN, an ingress fault has been detected.
- When flashing RED, an error has occurred.
The LCD let the user know information about the unit.
Line 1: indicates the highest ingress measured value in the last second and
the associated RF port.
Line 2: the IP address is displayed when there is no problem. When there is a
problem, several messages can be displayed:
- “NO IP ADDRESS”: No ip address is assigned to the unit. Verify that the network cable is plug into the Ethernet jack.
- “FTP ERROR”: The IRX1 unit cannot transmit data to the Effigis FTP server. Make sure that the unit have access to the internet. Note that the unit can acquire a valid IP address, but if there is no routing to the internet, this message will be displayed.
5.3 Communication
The IRX1 uses an RJ-45 Ethernet (10/100 Mbits/sec) Cat 5 cable to connect to
the network.
5.4 Shutdown
To power off the unit there are two modes Normal and Force shutdown, usually
the user should privilege the normal shutdown mode to avoid undesired flash
memory corruption, force shutdown should be use ONLY in case that the device
is no more responding.
5.4.1 Mode Normal Shutdown:
In normal running application user should press the button press the front
panel push button ON/OFF for 1 second then let the IRX1- ends up every process
properly than a message will follow on the front LCD then the device will turn
off.
5.4.2 Mode Force Shutdown:
To force the IRX1- to power down when it’s running, press in the ON/OFF button
on the front panel for 3 seconds. When the unit stops, you can release the
button. As it was mention previously this is not the ideal shutdown method.
System Maintenance
6.1 Cleaning of the Equipment
Your IRX1 unit can be wiped clean with a damp cloth. Do not immerse the unit
in water. Avoid solvents and commercial cleaners.
6.2 Preventative Maintenance
The technician shall do periodic visual inspections on the RF connections to
make sure that there is nothing loose or broken. Both can affect the
performance of the system. In case that a replacement is required, please
contact Effigis for more information.
Real-time Ingress Monitor (RIM) on your Smart-Phone
The RIM service we provide, consist of a web site that receive in real-time
the ingress information receive at the receiver. Its purpose is to assist
technicians on the field to
locate with precision the source of Ingress on the cable network.
7.1 Login the RIM Website
To consult data on the RIM the user must have a smart phone or a laptop with
at least an access to the internet. The user must have a CPAT profile, which
consist of a username and a password to login on the website www.cpat-
solution.com/RIM.
NOTE
The RIM is also available as a mobile application for iOs and Android. To
download it, connect to the Apple App store (iTunes) or the Android App store
(Google Play), and download the “CPAT” app. The first module within this app
is an enhanced version of the RIM software on the web.
7.2 Choose the Proper ITX
Once the user is logged in the website he must choose the proper ITX from the
list and then he will be able to view all the data available from this
particular ITX. Remember that the higher the value is, the closer the trouble
is.
Updates and Recovery
The IRX1- device can be update automatically or manually. Usually the system
should update its firmware when needed via updates provided from our FTP
website.
8.1 Automatic Update
The IRX1- device is usually automatically updated when needed. The updates are
distributed from our FTP server to the device. All update are tested to ensure
high quality and efficiency in our product. There is no need for external
intervention on the device to update it using the automatic update.
8.2 Manual System Recovery
See the remote troubleshooting section.
Remote Troubleshooting
It is possible to access the IRX1 for remote assistance. Also, manual firmware
and script updates can be achieved. If the problem is the internet connection,
it will not possible to do so.
Appendix A – Specifications
A.1 System
Operating frequency selection/Bandwidth| 06.78 MHz: 30 kHz
13.56 MHz: 14 kl-lz
27.12 MHz: 30 kHz
---|---
Measurement range| -24 to 12 dBmV
Sensitivity| -24 dBmV (BER < 10A-6) (attenuator 0 0 dB)
AGC attenuator| 0-15 dB in 0.5 dB steps
Level accuracy| ±2 dB on signal pulses
Maximum input level| 40 dBmV per RF input (integration in the 5 to 45 MHz
band)
Monitoring mode| Continuous shared detection between 8 RF ports
Frame capture time| 10 ms
Continuous ingress detection capability| 100 events/sec/IRX1
Communication port| 10/100 Base-T Ethernet
Communication protocol| IP (version 4)
Power| 120 VAC, 0.7A (60W) fully loaded
Operating temp| 0°C — 60°C (32°F —140°F)
Storage temp| -20°C — 80°C (-4°F — 176°F)
A.2 Physical
Dimensions | 1.75″ x 16.60″ x 18.50″ [H x W x D] 4.5 cm x 42.2 cm x 47.0 cm |
---|---|
Weight | 4 Kg |
Maximum relative | humidity 80% for temperatures up to 31°C (88°F) decreasing |
linearly to 50% relative humidity at 40°C (104°F).
Appendix B – Our Services
Effigis offers a portfolio of services to deploy and support purchased
equipment through its Customer Support organization. Customer Support is
standard with every product sale and consists of business hour technical
assistance, in-warranty repair and calibration.
B.1 System
Customer Support is accompanied with the sale of every Effigis product.
Customer Support services include:
- Product and Service Literature.
- Technical Assistance (Business Hour).
- Equipment Repair (Under Warranty Repair and Calibration Services).
- Equipment Return Authorizations.
Contact a Customer Support representative through your local distributor or by accessing www.effigis.com for information on calibration and warranty policies.
B.1.1 Equipment Return Instructions
Please contact your local Customer Support location via telephone for Return
Authorization to accompany your equipment. For each piece of equipment
returned for repair, attach a tag that includes the following information:
- Owner’s name, address, and telephone number.
- The serial number, product type, and model.
- Warranty status (If you are unsure of the warranty status of your instrument, contact Effigis’ Customer Support).
- A detailed description of the problem or service requested.
- The name and telephone number of the person to contact regarding questions about the repair.
- The return authorization (RA) number.
If possible, return the equipment using the original shipping container and
material. If the original container is not available, the unit should be
carefully packed so that it will not be damaged in transit; when needed,
appropriate packing materials can be obtained by contacting Effigis Support.
Effigis is not liable for any damage that may occur during shipping. The
customer should clearly mark the Effigis’ issued RA or reference number on the
outside of the package and ship it prepaid and insured to Effigis. Equipment
repaired or replaced under warranty will be returned at Effigis’s expense to
Customer (Canada/USA) or Effigis’ representative (all other countries).
B.2 Limited Product Warranty
B.2.1 Hardware
Effigis warrants to the original end user (Customer) that the new Effigis
branded products will be free from defects in workmanship and materials, under
normal use, for one (1) year from the date of original shipment. Effigis
warrants repaired products for ninety (90) days from date of shipment. Any
Product repaired or replaced under warranty is only warranted for the period
of time remaining in the original warranty for the Product.
Any third party products, including software, included with Effigis products
are not covered by this Effigis warranty and Effigis makes no representations
or warranties on behalf of such third parties. Any warranty on such products
is from the supplier or licensor of the product.
B.2.2 Software
Effigis warrants to the Customer that new Effigis branded software and
firmware will perform in substantial conformance to program specifications for
a period of ninety (90) days from the date of original shipment. Effigis
warrants the media containing software against failure during the warranty
period.
Effigis makes no warranty or representation that the operation of the software
products will be uninterrupted or error free, or that all defects in the
software products will be corrected.
B.2.3 Exclusions
This warranty excludes:
- Damage to the physical surface of the product, including cracks or scratches to any part.
- Damage caused by misuse, neglect, improper installation or testing, unauthorized attempts to open, repair, or modify the product, or any other cause beyond the range of the intended use.
- Use of the product with any non-recommended device or service if such device or service causes the problem.
- Installation or maintenance of Product by someone other than Effigis or persons certified by Effigis.
- Changes to the Customer environment in which Product was installed.
- Damage caused by accident, fire, power changes, other hazards, or acts of nature.
- Consumable Product or parts thereof (e.g., parts with an expected useful life of less than ninety (90) days).
- Product not returned in accordance with Effigis’ RA procedure.
B.2.4 Refurbished Parts and Prior Testing
Product may incorporate reconditioned or refurbished parts or subassemblies
and may have been used in testing prior to sale.
B.2.5 Exclusive Remedies
If any Product materially fails to conform to the limited warranty set forth
in this Section (Limited Warranty) and actually fails during the applicable
warranty period and under normal use, ffigis shall, at its sole discretion
(i) repair or replace the non-conforming Product to remedy the nonconformity
identified by Customer in accordance with
this Section (Limited Product Warranty); or (ii) issue a credit to Customer
for the amounts paid for the Product in exchange for return of the
nonconforming Product, in which case Customer’s licenses to any Firmware
shall be automatically revoked. Customer hereby transfers to Effigis title and
ownership of any parts that Effigis replaces.
B.2.6 Disclaimer
THE REMEDIES EXPRESSLY PROVIDED IN THIS SECTION WILL BE CUSTOMER’S SOLE AND
EXCLUSIVE REMEDIES AND SHALL BE IN LIEU OF ANY OTHER RIGHTS OR REMEDIES
CUSTOMER MAY HAVE AGAINST EFFIGIS WITH RESPECT TO ANY NON-CONFORMANCE OF
PRODUCTS. EXCEPT AS SPECIFIED IN THIS LIMITED PRODUCT WARRANTY, EFFIGIS MAKES
NO EXPRESS REPRESENTATIONS OR WARRANTIES WITH REGARD TO ANY PRODUCT. EFFIGIS
DISCLAIMS ALL IMPLIED WARRANTIES, CONDITIONS, AND REPRESENTATIONS INCLUDING,
BUT NOT LIMITED TO, ANY ARRANTIES OR CONDITIONS OF MERCHANTABILITY,
SATISFACTORY QUALITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT,
REGARDLESS OF THE LEGAL THEORY ON WHICH SUCH IMPLIED WARRANTY MAY BE BASED,
INCLUDING, WITHOUT LIMITATION, CONTRACT, COURSE OF DEALING, USAGE, OR TRADE
PRACTICE.
EQUICOM Merestechnikai Kft.
1162 Budapest, Matyas Kiraly utca 12.
www.equicom.hu
info@equicom.hu
+361272 1234
effigis.com
1.888.495.6577
References
- Effigis : Geosolutions, GIS data, Analysis and Software
- RIM 3.13
- Effigis : Geosolutions, GIS data, Analysis and Software
- VU#107886 - ISC dhclient vulnerability
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>