OMRON E32-LT11N Hex Shaped Fiber Unit User Manual

June 3, 2024
Omron

OMRON E32-LT11N Hex Shaped Fiber Unit

OMRON E32-LT11N Hex Shaped Fiber Unit

NEW STANDARD FOR THE FUTURE

Introducing Hex-shaped Models with Build-in Lenses

New Hex-shaped Models

Smart Fiber Amplifier Unit E3NX-FA

Hex-shaped Fiber Unit Series

Fiber Units with Build-in Lenses

provide more stable detection and simpler, more reliable installation.

Hex-shaped models are now available with high-power built-in lenses for stable detection.
Achieve stable detection and easy onsite application.

Fiber Units with Build-in Lenses

Fiber Units with Build-in Lenses

Hex Shape

Hex Shape

Build-in Lens

Stable Detection

Long-term Stable Detection Even in Dusty Environments
The E32-LT11N’s incident light level is approx. 10 times higher than that of the conventional Fiber Units.*1 High power means stable detection even in dusty and dirty environments.
Build-in Lens

Stable Detection of Target Area Changes
The E32-LD11N’s signal change (S/N ratio) is approx. 3 times higher than that of the conventional Fiber Units.*2 Because the target area is viewed with the narrow field of a 15° aperture angle, there is a greater difference in incident light levels and objects can be detected reliably.
Build-in Lens

Reduce False Detection Caused by Scattered Light
False Detection is greatly reduced because the 15° aperture angle eliminates scattered light, even in tight spaces.
Build-in Lens

Build-in Lens Provides Simplicity and Reliability

Build-in Lens

Build-in Lens

Through-beam Fiber Units

Specifications

Through-beam Fiber Units

Dimensions (mm) Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
E32-LT11N 2M (Free Cutting)

E32-LT11N 2M \(Free Cutting\)

Reflective Fiber Units/ Retro-reflective Fiber Units

Specification

Reflective Fiber Units/ Retro-reflective Fiber Units

Dimensions (mm) Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
E32-C21N 2M (Free Cutting)
E32-LT11N 2M \(Free Cutting\)

E32-LD11N 2M (Free Cutting)
E32-LD11N 2M \(Free Cutting\)

E32-LR11NP 2M (Free Cutting)
E32-LR11NP 2M \(Free Cutting\)

  1. The following mode names and response times apply to the modes given in the Sensing distance column.
    E3X-HD GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and SHS: Super-high-speed mode (NPN output: 50 μs, PNP output: 55 μs)
    E3NX-FA GIGA: Giga-power mode (16 ms), HS: High-speed mode (250 μs), ST: Standard mode (1 ms), and SHS: Super-high-speed mode (30 μs)

  2.  The optical fiber is 2 m long on each side, so the sensing distance is 4,000 mm.

  3. The values for the minimum sensing object are reference values that indicate values obtained in standard mode with the sensing distance and sensitivity set to the optimum values.
    The first value is for the E3X-HD and the second value is for the E3NX-FA.

  4. The sensing distances for Reflective Fiber Units are for white paper. The sensing distances for the E32-LD11N 2M are for glossy white paper.
    Note. Objects with a high reflection factor may cause the Retro- reflective Fiber Sensor to detect reflected light as incident light.
    Detection may be unstable depending on the type of transparent object. Check suitability beforehand.

Installation Information

Through-beam Fiber Units

Models Installation Cable Weight (packed state) (g)
Ambient temperature Tightening torque Mounting hole Bending radius
Unbendable length Tensile strength Sheath material Core material

Emitter/receiver differentiation
E32-LT11N 2M| -40 to 70℃| 0.78 N . m| 4.2 +0.5 dia. 0| R2| 0| 29.4 N| Polyethylene| Plastic| None| Approx. 40 g

Reflective Fiber Units/ Retro-reflective Fiber Units

Models Installation Cable Weight (packed state) (g)
Ambient temperature Tightening torque Mounting hole Bending radius
Unbendable length Tensile strength Sheath material Core material

Emitter/receiver differentiation
E32-C21N 2M| -40 to 70℃| 0.29 N . m| 3.2 +0.5 dia.

0

|

R2

| 0| 9.8 N| Polyethylene| Plastic| White line on emitter cable| Approx. 30 g
E32-D21N 2M| -40 to 70℃| 0.78 N . m| 4.2 +0.5 dia.

0

| 0| 9.8 N| Polyethylene| Plastic| None| Approx. 30 g
E32-LD11N 2M| -40 to 70℃| 0.98 N . m| 6.2 +0.5 dia.

0

| 0| 29.4 N| Polyethylene| Plastic| None| Approx. 40 g
E32-LR11NP 2M| -40 to 70℃*| 0.98 N . m| 6.2 +0.5 dia.

0

| 0| 29.4 N| Polyethylene| Plastic| None| Approx. 40 g

* Ambient operating temperature of the recommended reflector (E39-RP1) is -40 to 60℃.

Accessories

Appearance Models Quantity Remarks
  E39-F9W13 1 1.3-dia. Attachment

Provided with applicable Fiber Units.
Order this accessory separately if you lose or damage it.
| Improved thin attachment. The protrusion was reduced to help you save space. You can also just insert the cable into this one-piece Attachment to save work.
---|---

Applicable Fiber Units: E32-C21N, E32-D21N
Applicable Fiber Amplifier Units: E3NX-FA, E3X-HD, E3X-DA-S series

Related Fiber Units

Introduction to Fiber Sensors

OMRON also provides many other types of Fiber Sensors.
Refer to Fiber Sensor Best Selection Catalog (E418).
Introduction to Fiber Sensors

Fiber Amplifier Units
  E3X-HD Series E3NX-FA Series

Fiber Amplifier
Unit specifications| Output| 1 output| 1 or 2 outputs (depending on the model)
External input| Not supported| Supported or not supported (depending on the model)
Response time*| 50 μs (55 μs)/250 μs/1 ms/16 ms| 30 μs (32 μs)/250 μs/1 ms/16 ms
(Default: 250 μs)| (Default: 250 μs)
Sensing distance (Giga-power mode)| E32-LT11N| 4,000 mm| 4,000 mm
E32-LD11N| 840 mm| 1,260 mm
Minimum sensing object| E32-LT11N| 0.1 mm dia.| 0.03 mm dia.

* These are the response times for super-high-speed mode (SHS), high-speed mode (HS), standard mode (Stnd), and GIGA-power mode (GIGA).
The value in parentheses for the super-high-speed mode is for a model with a PNP output.

OMRON Corporation Tokyo, JAPAN
Industrial Automation Company

Contact: www.ia.omron.com

Regional Headquarters
OMRON EUROPE B.V.
Sensor Business Unit
Carl-Benz-Str. 4, D-71154 Nufringen, Germany
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199

OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark,
Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711

OMRON ELECTRONICS LLC
One Commerce Drive Schaumburg,
IL 60173-5302 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787

OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
PuDong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200

OMRON Logo

© OMRON Corporation 2013-2021 All Rights Reserved.
In the interest of product improvement,

Documents / Resources

| OMRON E32-LT11N Hex Shaped Fiber Unit [pdf] User Manual
E32-LT11N, E32-LD11N, E32-LR11NP, Hex Shaped Fiber Unit
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals