AGROLAN YT60160 Weather Station User Guide
- June 3, 2024
- AGROLAN
Table of Contents
- Function
- Profi Wireless Weather Station
- Technical specifications
- Getting Started/Installation
- Radio Controlled Clock (DCF77)
- **Manual Settings
- Alarm Settings
- Alarm Activation/Deactivation/Snooze
- Setting Unit of Precipitation
- Setting Unit of Wind Speed
- Setting Temperature Limits for Maximum and Minimum Temperature
- Temperature limit ranges
- Station Display Backlight
- Weather Forecast
- Upkeep and Maintenance
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
AGROLAN YT60160 Weather Station
Weather Station
YT60160
Function
- Calendar
- Indoor and outdoor
- temperature or
- humidity
- Barometer
- Weather forecast
- Wind speed
- Wind direction
- Rainfall record
- Alarm clock
- Moon phase
- Temperature trend
- Humidity trend
- Barometer trend
- In/out temperature
- alert
- Radio controlled clock
- Touch key
Weather station size: 188.6×125.6×14.5mm
Anemometer size: 390x264x133mm
Rain gauge size: 166×105.5x118mm
Profi Wireless Weather Station
- snooze/light button
- number of temperature/humidity and wind sensor 1/2/
- outdoor temperature
- cycling through data from connected sensors
- outdoor temperature trend
- outdoor humidity trend
- weather forecast
- moon phase
- pressure history
- pressure value
- pressure trend
- indoor temperature alert
- indoor temperature
- indoor temperature trend
- station batteries low
- indoor humidity trend
- indoor humidity
- alarmno.1/no.2
- time, DCF signal reception, daylight savings time (DST)
- day of the week
- UP button – step forward in settings, memory of max/min temperature and humidity
- date
- DOWN button – step back in settings
- wind direction indicator
- CHANNEL button – searching for sensor signal/switching through information from connected sensors
- wind direction: S – south, W – west, N – north, E – east
- ALARM button – alarm activation/deactivation
- SET button – 0crF unit of temperature setting, function settings
- MODE button – display mode switching
- data from precipitation sensor
- signal from precipitation senso
- low batteries in precipitation sensor
- wind speed
- signal from temperature/humidity and wind sensor
- low batteries in temperature/humidity and wind sensor
- outdoor humidity
- outdoor temperature alert
- low batteries in temperature/humidity and wind sensor
- power adapter socket
- battery compartment
- stand
- alarm speaker
- holes for hanging on a wall
- precipitation sensor battery cover
- precipitation sensor grille
- wind sensor cups
- compass
- wind direction paddle
- temperature/humidity/wind sensor battery compartment Buttons:TX – send signal from sensor to station, 1/2/3 – switch sensor channel number, WAVE – manually activate/deactivate DCF signal reception
- mounting rod (26 mm diameter)
- mounting base
Technical specifications
clock controlled by DCF77 radio signal
time format: 12/24 h
indoor temperature: -10 °C to +SO °C, 0.1 °C resolution
outdoor temperature: -30 °C to +60 °C, 0.1 °C resolution
temperature measurement accuracy: +1 °C for 20 °C to +24 °C range, +2 °C for O
°C to +20 °C and
24 °C to +40 °C range,+ 3 °C for -20 °C to O °C and 40 °C to +50 °C range, +4
°C for other ranges.
indoor and outdoor humidity: 1-99 % RH, 1 °/4 resolution
humidity measurement accuracy: 5 %
displayed units of temperature: °C/°F
barometric pressure measurement range: 800 hPa to 1 100 hPa
unit of pressure: hPa/inHg
wind sensor measurement range: 0 to 127.5 km/h
unit of wind speed: km/mph
precipitation sensor measurement range: 0 to 2,999 mm
unit of precipitation: mm/inch
radio signal range: to 100 m in open area
number of sensors which can be connected: max. 3 (temperature/humidity/wind
sensor), max. 1
(precipitation sensor)
wireless sensor: transmission frequency 433 MHz, 10 mW e.r.p. max.
station power supply: 3x 1.5 V AAA batteries (not included)
adapter AC 230 V /DC 5 V, 300 mA (included)
temperature/humidity/wind sensor power supply: 4x 1.5 V AA (not included)
precipitation sensor power supply: 2x 1.5 V AA (not included)
station dimensions and weight: 17 x 192 x 127 mm, 364 g
temperature/humidity/wind sensor dimensions and weight: 275 x 135 x 310 mm,
377 g (without
batteries)
precipitation sensor dimensions and weight: 100 x 106 x 166 mm, 220 g (without
batteries)
Getting Started/Installation
- Plug the power adapter into the station, then insert batteries first into the weather station (3x 1.5 V AAA) and then into: wireless temperature/humidity/wind sensor (4x 1.5 V AAA) and wireless precipitation sensor. The battery compartment of the precipitation sensor is protected by screws; use a suitable screwdriver.
- When inserting the batteries make sure the polarity is correct to avoid damaging the weather station or sensors. Only use alkaline batteries of the same type; do not use rechargeable batteries.
- Place all the units next to each other. The weather station will automatically detect the signal from sensors within 3 minutes. If signal from sensors is not detected, long-press the button on the weather station to repeat the search and press the TX button on the sensor.
- To ensure correct measurement, the temperature/humidity/wind sensor and precipitation sensor must be placed above the ground surface (at least 1.5 m) onto a horizontal surface and outside of buildings and structures. Both sensors must be firmly screwed on to prevent their damaging. First, screw the mounting plate onto a level surface, then mount the mounting rod into it. Screw the temperature/humidity/wind sensor onto the rod. Wind must flow freely around the wind sensor from all sides. Check that the wind direction indicator and paddles for measuring wind speed can rotate freely. The north arrow (N) on the built-in compass must point to the real north. Otherwise, wind direction will always be displayed incorrectly. When choosing a suitable place for mounting the sensor, check before installation that the main station is within range of the sensors. The range of the sensors may decrease substantially in areas with large number of obstacles.
- Do not place the sensors onto metal objects as this will reduce their transmission range.
- If the low battery icon is displayed, replace batteries in the sensors or weather station.
Changing Channel and Connecting Additional Sensors (Valid for
Temperature/Humidity/Precipitation Sensor}
- Choose the desired channel 1, 2, or 3 for the sensor by repeatedly pressing the button. Then, long press the button; the icon will start flashing.
- Remove the cover from the battery compartment on the rear of the sensor and set the sensor switch to the desired sensor channel number (1, 2, 3), then insert batteries (4x 1.5 V AA). Data from the sensor will be loaded within 3 minutes.
- If sensor signal is not found, remove the batteries and proceed again in accordance with steps 1 and 2 or press the TX button.
Displaying Data from Multiple Sensors, Automatic Cycling through Values
from Connected Sensors
Press the button repeatedly to display data from all connected sensors on
the weather station, one by one. You can also activate cycling through data
from all connected sensors:
-
turning on cycling
Repeatedly press the button until the display shows the icon. Data from all 3 sensors will be shown automatically and repeatedly one after another. -
turning off cycling
Repeatedly press the button until the icon disappears.
Radio Controlled Clock (DCF77)
The wireless temperature/humidity/wind sensor will automatically start searching for DCF77 (hereinafter referred to as DCF) signal for 5 minutes after pairing with the weather station; the icon is flashing. (The DCF sensor is located in the temperature/humidity/wind sensor). Signal detected -the icon stops flashing and the current time will be displayed with the DCF icon Signal not detected – DCF icon will not be displayed. DCF signal will be synchronized daily between 2:00 and 3:00 am.
You can also activate search for DCF signal manually.
Long-press the WAVE button located in the battery compartment of the
temperature/humidity/wind sensor. The sensor will start searching for DCF
signal. To end the search, long-press the WAVE button again.
Note: If the weather station detects DCF signal but the current time on
the display is incorrect (e.g. shifted ± 1 hourJ you must always set the
correct time zone for the country where you are using the station, see Manual
Settings. In standard conditions (at safe distance from sources of
interference, such as TV sets or computer monitors), the reception of time
signal takes several minutes. If the weather station does not detect the
signal, follow these steps:
- Move the weather station to another location and try to detect DCF signal again.
- Check the distance of the clock from sources of interference (computer monitors or television sets). It should be at least 1.5 to 2 m during the reception of signal.
- When receiving DCF signal, do not place the weather station in the proximity of metal doors, window frames and other metal structures or objects (washing machines, dryers, refrigerators etc.).
- In reinforced concrete structures (cellars, high-rise buildings etc.), the DCF signal reception is weaker, depending on the conditions.
Reception of the DCF 77 radio signal is affected by the following
factors:
thick walls and insulation, basements and cellars, inadequate local
geographical conditions (these are difficult to assess in advance),
atmospheric disturbances, thunderstorms, electrical appliances with no
interference elimination, television sets and computers, located near the DCF
radio receiver.
**Manual Settings
**
All changes in values are made using buttons and . After setting the desired
value and not pressing any other buttons, the set values will automatically
save and the display will switch to the main screen.
Setting Time, Date and Time Zone
- Short-press the button
- Press the button for 3 seconds and use the and buttons to set the following values: time zone, calendar language (ENG, GER, FRE, ITA, DUT, SPA, DAN), year, date format, month, day, 12/24 h time format, hour, minute, second.Confirm
- the set value by pressing the button; holding the arrow keys speeds up settings.
Alarm Settings
2 alarms can be set on the weather station.
- Short-press the button twice
- Press the button for 3 seconds and use the arrows to set the alarm hour and minute.
- Confirm the set value by pressing button; holding the arrow keys speeds up settings.
Alarm Activation/Deactivation/Snooze
Repeatedly pressing the button activates alarm 1 (AL 1); alarm 2 (AL2); or
both alarms at the same time (AL 1, AL2); or deactivates the alarms. You can
postpone (snooze) the alarm by 5 minutes by pressing the **ZZ**
button.
After pressing, the AL1 AL.2 zZ icons will start flashing.
Turn off the alarm .pressing . After pressing, the AL1 tiJ AL2 zZ icons will
stop flashing and only AL1 AL2 will remain on the screen. The alarm will
activate again the next day.
Setting Altitude and Atmospheric Pressure
The station shows atmospheric pressure in hPa or inHg and keeps a history
of pressure readings for the last 12 hours.
To achieve more accurate calculation of pressure values, it is advised to
manually set the altitude for the place where the weather station is being
used.
- Short-press the button three times
- Press the button for 3 seconds and use the arrows to set altitude between -90 m to+ 1,990 m (1 O m increments).
- Pressing the button switches between M/hpa and Ft/inHg units.
- Short-press the button to quit settings.
Setting Unit of Precipitation
- Press the button five times, then press the button for 3 seconds.
- Use the and arrows to set mm or inches as units.
- Short-press the button to quit settings.
Setting Unit of Wind Speed
- Press the button six times, then press the button for 3 seconds.
- Use the and arrows to set km/h or mph as units.
- Short-press the button to quit settings.
Setting Temperature Limits for Maximum and Minimum Temperature
Temperature limits can be set independently for up to 3 outdoor temperature sensors. When minimum or maximum temperature limit is activated, the LO (min) or HI (max) icon will appear on the screen and disappear after deactivation.
Temperature limit ranges
| Outdoor| Indoor
---|---|---
Minimum| -30 °Cto +l 0°C| 0°C to 23 °C
Maximum| 28 °C to +60 °C| 26 °Ct o S0 °C
Resolution| 0 .5 ° (| 0.5°(
While on the main screen, repeatedly press the button to switch to sensor 1, 2 or 3 and proceedfor each sensor as follows.
- Short-press the button four times.
- Press the button for 3 seconds and set the minimum outdoor temperature.
- Short-press the button and activate (ON)/deactivate (OFF) the outdoor minimum temperature alert.
- Short-press the button and set the minimum outdoor temperature.
- Short-press the button and activate (ON)/deactivate (OFF) the outdoor maximum temperature alert.
- Short-press the button and set the minimum indoor temperature.
- Short-press the button and activate (ON)/deactivate (OFF) the indoor minimum temperature alert.
- Short-press the button and set the minimum indoor temperature.
- Short-press the button and activate (ON)/deactivate (OFF) the indoor maximum temperature alert.
- When the set temperature limit is exceeded, an audio alarm will sound for 1 minute and the value will begin flashing.
Pressing any button on the screen cancels the alert sound, but the symbol of
an active alert will continue flashing. Once temperature drops below the set
limit, the symbol on the screen will stop flashing.
Temperature, Humidity and Pressure Trends
Rising ,;,
Constant ➔
Falling -..
Moon Phases
| | | | | | |
---|---|---|---|---|---|---|---
1| 2| 3| 4| 5| 6| 7| 8
- New moon 5-Full moon
- Waxing crescent 6 – Waning gibbous
- First quarter 7 – Last quarter
- Waxing gibbous
- Full moon
- Waning gibbous
- Waning gibbous
- Waning crescent
Note: In the period between 18:00 and 06:00, the moon icon will be surrounded by stars.
Displaying Maximum and Minimum Readings ofTemperature/Humidity and Wind
Repeatedly pressing the button will gradually show maximum and minimum
measured temperature and humidity values and maximum wind strength. The memory
of measured values is automatically erased every day at 00:00. Or long-press
the button to erase the memory automatically.
Displaying Measured Values from the Precipitation Sensor Repeatedly
pressing the button will gradually show measured precipitation values in
various time periods.
Accumulated
Today
Last hour
Yesterday
This week Long-pressing the button erases the measured value.
Station Display Backlight
When powered via adapter:
Permanent backlighting is set automatically. Repeatedly pressing the
SNOOZE/LIGHT button will allow you to set 4 different levels of permanent
backlighting (off, maximum, medium, low).
When powered only by 3x 1.5 V AAA batteries:
Display backlighting is off. Pressing the SNOOZE/LIGHT button will turn the
display backlight on for 5 seconds, then it turns off again. When the station
is only powered by batteries, permanent backlighting of the display cannot be
activated!
Note:
The inserted batteries serve as backup for the measured/set data.
If batteries are not inserted and you unplug the adapter, all data will be
erased.
Weather Forecast
The station forecasts weather on the basis of changes in atmospheric pressure for the next 12-24 hours for an area within the range of 15-20 km. The accuracy of weather forecast is 70-75 %. The forecast icon is displayed in field no. 7. As the weather forecast may not always be 100 % accurate, neither the manufacturer nor the seller can be held responsible for any loss caused by an incorrect forecast. After first setting or after resetting the weather station, a learning mode will be activated, indicated by LEARNING … appearing on the screen he station will evaluate measured data and continuously increase the accuracy of forecast. This mode continues for 14 days, then the LEARNING … icon automatically disappears. Weather Forecast Icons:
| | | |
---|---|---|---|---
Sunny| Cloudy| Overcast| Raining/ snowing| Heavy rain/heavy snow
Upkeep and Maintenance
- Read the manual carefully before using this product.
- Do not expose the product to direct sunlight, extreme
- cold and moisture, and sudden changes in temperature as these may compromise detection accuracy.
- Do not place the product in locations prone to vibration and shocks; these may cause damage.
- Do not expose the product to excessive pressure, impacts, dust, high temperatures or humidity – these may cause
- malfunction, shorter battery life, damage to batteries and deformation of plastic parts.
- Do not expose the product to rain or moisture, it is not designed for outdoor use.
- Do not place any open flame sources on the product, e.g. a lit candle, etc.
- Do not place the product in places with inadequate air flow.
- Do not tamper with the internal electric circuits of the product. Doing so might damage it and automatically void the warranty.
- The product should only be repaired by a qualified professional.
- To clean the product, use a slightly moistened soft cloth. Do not use
- solvents or cleaning agents; they could scratch the plastic parts and cause corrosion of the electric circuits.
- Do not immerse the product in water or other liquids.
- The product must not be exposed to dripping or splashing water.
- In the event of damage or defect on the product, do not perform any repairs by yourself.
- Have it repaired in the shop where you bought it.
- Place the product out of reach of children; it is not a toy.
- Remove flat batteries; they could leak and damage the product.
- Use only new batteries of the recommended type and make sure polarity is correct when replacing them
- Do not throw batteries into a fire and do not disassemble or short-circuit them. This device is not intended for use by persons {including children) whose physical, sensory or mental disability or lack of experience and expertise prevents them from safely using the device, unless they are supervised or instructed in the use of the device by a person responsible for their safety. Children should be supervised to ensure they do not play with the device.
After use, the device and batteries become hazardous waste – do not throw them
into unsorted municipal waste but return them to a collection point – e.g. the
shop where you purchased the product.
~ Do not dispose with domestic waste. Use special collection points for sorted
waste. Contact local A authorities for information about collection points. If
the electronic devices would be disposed – in landfill, dangerous substances
may reach groundwater and subsequently food chain, whereit could affect human
health. Hereby, EMOS spol. s r. o. declares that the radio equipment type
E6016 is in compliance with Directive 2014/53/EU. The full text of the EU
declaration of conformity is available at the following internet address:
http://www.emos.eu/download
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>