SPER SCIENTIFIC 300058 Waterproof Digital Refractometer Instruction Manual
- June 3, 2024
- SPER SCIENTIFIC
Table of Contents
- Waterproof Digital Refractometer
- INTRODUCTION
- MATERIALS SUPPLIED
- FEATURES
- POWER SUPPLY
- FRONT PANEL DESCRIPTION
- LCD DISPLAY
- CALIBRATION
- MEASUREMENT PROCEDURES
- MEASUREMENT ERRORS
- SCALE INFORMATION
- SPECIFICATIONS
- WARRANTY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SPER SCIENTIFIC 300058 Waterproof Digital Refractometer Instruction Manual
Waterproof Digital Refractometer
Copyright ©2017 by Sper Scientific
ALL RIGHTS RESERVED
Printed in the USA
The contents of this manual may not be reproduced or transmitted in any form
or by any means electronic, mechanical, or other means that do not yet exist
or may be developed, including photocopying, recording, or
any information storage and retrieval system without the express permission
from Sper Scientific.
INTRODUCTION
Housed in a protective rubberized IP65 Waterproof case to safeguard the electronics from wet environments and makes for easy clean ups Model 300058 features a scratchproof sapphire lens.Measure samples as small as 1 ml, in the field with laboratory accuracy. Sample temperature is initially displayed on the large LCD followed by the measurement results. The sophisticated microprocessor provides automatic calibration, automatic temperature compensation and automatic shutoff.
Powered by a rechargeable, long-life, Li (Lithium Ion) battery providing 50,000 tests on a single charge.Simple one-button calibration using distilled water ensures accurate readings.
MATERIALS SUPPLIED
- Refractometer
- One lithium-Ion battery
- DC Power Adapter
- Distilled Water
- Transfer pipet
- Instruction Manual
- Carrying Case
FEATURES
- Displays sample temperature followed by measurement result
- IP65 Waterproof, rugged exterior
- Rechargeable battery
- Low battery indicator
- DC power adapter
- Automatic shutof
POWER SUPPLY
The meter is powered by one rechargeable lithium-ion battery. An icon in the upper-right corner of the LCD indicates the level of battery power available:
75%-100% power
40%-75% power
15%-40% power
Less than 15% power. (This icon will flash)
The DC adapter included plugs into the port on the left side of the meter. This both provides an alternate power supply and recharges the battery.
Automatic Shutoff
The power will automatically shut off if the meter is not used for 3 minutes.
FRONT PANEL DESCRIPTION
- POWER – Power on/off
- READ – Read measurements /select scale
- CAL – Calibrate meter
- LENS COVER
LCD DISPLAY
- S 1 – Current scale number
- BATTERY ICON – Battery power level
- DISPLAY – Displays temperature and readings
CALIBRATION
Use distilled water (refractive index 1.3330 to 1.3340) to calibrate the meter.
- With the meter turned off, place a few drops of distilled water on the lens.
- Close the lid to cover the lens.
- Press POWER to turn the meter on.
- The temperature of the distilled water appears on the LCD.
- Press and hold CAL for 2 seconds to enter Calibration Mode. “CAL” will be displayed to indicate that calibration is occurring.
- When calibration is finished the meter returns to Measurement Mode and “ – – – ” is displayed on the LCD.
Note…
For best results, calibrate the meter at 20°C.
Measurements can be taken at other temperatures, but the calibration should be
done at 20°C
MEASUREMENT PROCEDURES
After calibration you can remove the distilled water from the lens and begin measurement.
Note…
Use a clean, lint-free cloth or tissue to remove solutions from the lens.
- With the meter turned off, place a few drops of the solution being measured on the lens.
- Press POWER to turn the meter on.
- The temperature of the solution appears on the LCD.
- Close the lid to cover the lens.
- Press Read to view the measurement on the LCD.
- To change scales, press and hold Read for 2 seconds until the scale number changes. Repeat to cycle through the available scales. (see page 10)
- Press Read if desired to repeat the measurement.
MEASUREMENT ERRORS
Certain conditions can cause an error code to appear on the LCD:
Error Code & Cause
HHH The measurement is above the upper limit
LLL The measurement is below the lower limit
SCALE INFORMATION
Scale Indicator & Name – 300058
S1 Brix
S2 Refractive Index
S3 Dextran
S4 Fructose
S5 Glucose
S6 Lactose
S7 Maltose
Scale Indicator & Name – 300059
S1 Brix
S2 Refractive Index
Scale Indicator & Name – 300060
S1 Brix
S2 Refractive Index
Scale Indicator & Name – 300062
S1 Salinity %
S2 Salinity ‰
S3 Specific Gravity
S4 Refractive Index
Scale Indicator & Name – 300063
S1 Cleaner
S2 Ethylene Glycol
S3 Propylene Glycol
S4 Battery
Scale Indicator & Name – 300064
S1 Urine Specific Gravity
S2 Serum Protein
S3 Refractive Index
Scale Indicator & Name – 300065
S1 ADBLUE
S2 Refractive Index
SPECIFICATIONS
Unit of Measure | Range | Accuracy |
---|---|---|
Temperature | 0.0 °C to 40.0 °C | ±0.8 °C |
ATC Range | 0.0 °C to 40.0 °C | ±0.8 °C |
Sample Capacity | 0.3 mL to 1 mL | |
Measurement Time | 0.5 to 1.0 seconds | |
Waterproof Rating | IP65 |
Sugars – 300058
Unit of Measure | Range | Resolution | Accuracy |
---|---|---|---|
Brix | 0.0 to 88% | 0.1% | ±0.2% |
Refractive Index (nD) | 1.3330 to |
1.5100
| 0.0001| ±0.003 nD
Dextran| 0.0 to 10.6%| 0.1%| ±0.2%
Fructose| 0.0 to 68.9%| 0.1%| ±0.2%
Glucose| 0.0 to 59.9%| 0.1%| ±0.2%
Lactose| 0.0 to 16.5%| 0.1%| ±0.2%
Maltose| 0.0 to 15.6%| 0.1%| ±0.2%
Temperature| 0.0 to 40°C| 0.1°C| ±0.8°C
Brix 0 to 60% – 300059
Unit of Measure | Range | Resolution | Accuracy |
---|---|---|---|
Brix | 0 to 60% | 0.1% | ±0.2% |
Refractive Index (nD) | 1.3330 to |
1.4420
| 0.0001| ±0.003 nD
Brix 0 to 88% – 300060
Unit of Measure | Range | Resolution | Accuracy |
---|---|---|---|
Brix | 0 to 88% | 0.1% | ±0.2% |
Refractive Index (nD) | 1.3330 to |
1.5100
| 0.0001| ±0.003 nD
Salinity – 300062
Unit of Measure | Range | Resolution | Accuracy |
---|---|---|---|
Salinity | 0 to 28% | 0.1% | ±0.2% |
0 to 280‰ | 1‰ | ±2‰ | |
Specific Gravity | 1.000 to 1.217 | 0.001 | ±0.002 |
Refractive Index (nD) | 1.3330 to |
1.3900
| 0.0001 nD| ±0.003 nD
Automotive – 300063
Unit of Measure | Range | Resolution | Accuracy |
---|---|---|---|
*Windshield Washer Fluid | 32 to -40°F | 0.1°F | ±0.2°F |
Ethylene Glycol | 32 to -50°F | 0.1°F | ±0.2°F |
Propylene Glycol | 32 to -50°F | 0.1°F | ±0.2°F |
Battery | 1.000 to |
1.500 sg
| 0.001| ±0.005 sg
Note…
*Windshield Washer Fluid is an aqueous cleaner used in a vehicle’s automated spray system. It is not glass cleaner that is applied by hand and wiped with a towel. Windshield Washer Fluid is a mixture that may contain any or all of the following: detergent, methanol, propylene glycol, and silicone polymers. The output of the refractometer is the freezing point of the windshield washer fluid.
Clinical – 300064
Unit of Measure | Range | Resolution | Accuracy |
---|
Urine Specific
Gravity
| 1.000 to 1.050| 0.001| ±0.002
Serum Protein
g/dL
| 0 to 12| 0.1| ±0.2
Refractive Index (nD)| 1.3330 to
1.3900
| 0.0001| ±0.003 nD
Diesel Exhaust Fluid – 300065
Unit of Measure | Range | Resolution | Accuracy |
---|
ADBLUE
(Diesel Exhaust
Fluid)
| ****
0 to 40%
| ****
0.1%
| ****
±0.2%
Refractive Index (nD)| 1.3330 to
1.4098
| 0.0001| ±0.003 nD
WARRANTY
Sper Scientific warrants this product against defects in materials and
workmanship for a period of one (1) year from the date of purchase, and agrees
to repair or replace any defective unit without charge. If your model has
since been discontinued, an equivalent Sper Scientific product will be
substituted if available.
This warranty does not cover probes, batteries, battery leakage, or damage
resulting from accident, tampering, misuse, or abuse of the product. Opening
the meter to expose its electronics will void the warranty.
To obtain warranty service, ship the unit postage prepaid to:
SPER SCIENTIFIC LTD.
8281 E. Evans Rd., Suite 103
Scottsdale, AZ 85260
The defective unit must be accompanied by a description of the problem and your return address. Register your product online at www.sperwarranty.com within 10 days of purchase.
References
Read User Manual Online (PDF format)