SPER SCIENTIFIC 300056 Custom Pocket Digital Refractometers Instruction Manual
- June 5, 2024
- SPER SCIENTIFIC
Table of Contents
- SPER-SCIENTIFIC-300056-Custom-Pocket-Digital-Refractometers-PRODUCT
- INTRODUCTION
- PANEL DESCRIPTION
- CALIBRATION
- MEASUREMENT
- Models with Multiple Scales
- Notes and Precautions
- ZERO CHECKING
- BATTERY REPLACEMENT
- SPECIFICATIONS
- WARRANTY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SPER-SCIENTIFIC-300056-Custom-Pocket-Digital-Refractometers-PRODUCT
INTRODUCTION
Our Custom Scale Pocket Digital Refractometers measure your specified parameters with laboratory accuracy. The digital readout eliminates uncertainties, while the water resistant design facilitates clean ups and protects the electronics from moisture.
Features:
- Automatic Temperature Compensation
- Zero Calibration
- Automatic shut off
- Instantaneous reading
PANEL DESCRIPTION
- Stainless Steel Sample Plate
- Prism Cover
- Prism
- Keypad
- Battery Compartment
- Display
- Active Scale Indicator
- SCALES button
- READ button
- ZERO button
CALIBRATION
Calibration should be performed daily before sample testing begins. For best results, perform the calibration in a controlled environment of 68°F (20°C).
- Allow the refractometer and the distilled water to acclimate to the ambient environment.
- Clean the PRISM (3) before and after every use.
- Drop at least 1.0 ml of distilled water (0.0) onto the PRISM (3).
- Close the PRISM COVER (2).
- Press the READ (9) button to turn on the refractometer.
- Press the ZERO (10) button for 3 seconds to enter calibration mode.
- “CAL” flashes on the display. There will be a red flash in the PRISM (3).
- The calibration is complete after “End” is displayed.
MEASUREMENT
- Clean the SAMPLE PLATE (1) and PRISM (3) before and after every use.
- When the temperature difference between the ambient temperature and the refracto% ( ter is greater than 10°F (5°C), place the refractometer in the lab and allow it to adjust to the ambient temperature. Allow apx. 30 minutes for every 5°F (10°C) difference in temperature.
- Press the READ (9) button to turn the unit on and display the temperature. This unit features Automatic Temperature Compensation (ATC) within the range of 41~104°F (5~40°C), eliminating the need for manual temperature correction.
- Perform a calibration (pg 6) before the day’s first use or after extended daily use.
- Fill the PRISM (3) with about 1.0ml of the sample solution.
- Close the PRISM COVER (2).
- Press the READ (9) button immediately to obtain a reading. Delays may cause the sample to evaporate.
- Within 1 second, the value is displayed.
- When the reading is under%range, the low indicator (LLL) is displayed. The high indicator (HHH) is displayed when the reading is over%range.
Models with Multiple Scales
- Follow the measurement instructions (page 6), then press the SCALES (8) button and hold the button for 1 second to cycle through the options.
- displayed and the ACTIVE SCALE (7) indicator “▼” points to the selected scale.
- With the desired scale selected, press the READ (9) button to obtain the results.
Notes and Precautions
- The refractometer will automatically shut off after about 3 minutes of inactivity.
- After each use, clean the SAMPLE PLATE (1) and PRISM (3) with distilled water on a soft cloth, and wipe dry.
- If a film develops on the PRISM (3) it will repel test samples and affect readings. If this occurs, clean with a mild detergent.
- The prism is easily scratched, never use abrasive cleaning materials.
- Never submerge.
- Avoid spills around the unit.
- Avoid prolonged use or storage in extreme temperatures.
- Do not use in corrosive environments.
- not drop or shake the unit.
- Use the protective carrying case to prevent physical damage.
Erratic Readings
If the readings are significantly above or below the expected results,
consider the following:
- Sample contains more than one dissolved solid. For example, if the sample contains both salt and sugar, a Brix refractometer will not display the true sugar content because the salt content will skew the brix measurement.
- When diluting samples, be sure to use a pure solution such as distilled water.
- Sample contains suspended solids. Filter and thoroughly mix the sample before testing.
- Perform a calibration.
- Replace the battery.
- Outside light can cause erratic readings, make sure to close the COVER on the PRISM during measurement.
- After about 3000 tests, turn the unit off for 5 to 10 minutes to rest the battery.
ZERO CHECKING
Use this function to check the nD value of the zero setting for distilled water.
- 6ill the PRISM (3) with a standard solution of distilled water (0.0) that is the same tem%$ rature as the solution to be tested.
- Close the PRISM COVER (2).
- Press the READ (4) button to turn the refractometer on and obtain a temperature reading.
- Quickly press the ZERO (5) button once.
- The nD value of the solution is displayed.
- This information can be viewed at any time to show the last calibration value.
BATTERY REPLACEMENT
When the low%’attery symbol is displayed, push the tab to open the BATTERY COMPARTMENT (5) and replace the 1.5V AAA battery with a fresh alkaline battery.
SPECIFICATIONS
Weight
| ****
5.3 oz, 150 grams
---|---
Dimensions
| 5″ x 2 1/2″ x 1 1/4″
120 x 65 x 30 mm
Storage Environment| ****
14~122°F (–10~50°C)
Operating Environment| Below 90% RH
Below 2000m sea level 32~104°F (0~40°C)
Battery Life
| ****
Approx. 8000 tests
Included
| Protective Case 1.5V AAA Battery
Distilled Water Transfer-Pipette
Scale | Range | Res. | Accuracy |
---|---|---|---|
Use pure distilled water as the calibration solution for all models.
WARRANTY
Sper Scientific warrants this product against defects in materials and workmanship for a period of 1 year from the date of purchase, and agrees to repair or replace any defective unit without charge. If your model has since been discontinued, an equivalent Sper Scientific product will be substituted if available. This warranty does not cover probes, batteries, or damage resulting from accident, misuse, or abuse of the product. In order to obtain warranty service, ship the unit postage prepaid to:
Sper Scientific
7720 E Redfield Rd, Suite 7 Scottsdale, AZ 85260 email:
info@sperscientific.com Include a
description of the problem and your return address along with the returned
item. Return your warranty card within 10 days of purchase or register online
at:
www.sperscientific.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>