REIGN TX-100-NC Remote Transmitter & Receiver Kit User Manual
- June 3, 2024
- REIGN
Table of Contents
- REIGN TX-100-NC Remote Transmitter & Receiver Kit
- Instructions
- HOW IT WORKS…
- Regulatory Statement
- Receiver Specifications
- TRANSMITTER SPECIFICATIONS
- POWER DETAILS
- LED INDICATORS
- RELAY DIAGRAM AND WIRING
- DIP SWITCHES
- BATTERY BACKUP
- PAIRING UNIT IN THE FIELD
- TROUBLESHOOTING
- WARRANTY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
REIGN TX-100-NC Remote Transmitter & Receiver Kit
Instructions
The Reign TX-100-NC & XRE-100 transmitter/receiver kit is a revolutionary product. This product allows for wirelessly triggering a relay through a battery powered hand held transmitter with extreme range, no line-of-sight wireless technology.
WHAT’S INCLUDED
There are two pieces included in the TX-100-NC to XRE-100 kit.
The Reign TX-100-NC to XRE-100 kit includes (1) TX-100-NC (transmitter) and
(1) XRE-100 (receiver units).
HOW IT WORKS…
Congratulations on your purchase of the Transmitter Solutions TX-100-NC to
XRE-100 – Transmitter/Receiver kit. It has been designed with state-of-the-art
radio technology to provide maximum transmission through obstruction and
interference.
The TX-100-NC to XRE-100 kit can be easily paired together with the
program/learn button on the XRE-100 board. Simply connect the Dry output
closure to the device you are triggering and you will be up and running.
The TX-100-NC is a send/receiver unit that sends a signal when the button is
pressed, indicated by a red LED light. And receives a signal back, indicated
by a green LED light. This allows users to know the signal was sent and
received by the corresponding XRE-100 unit.
IMPORTANT – When using XRE to TX-100-NC, Mode Dipswitch 2 ON
Regulatory Statement
FCC ID: 2ASPOXRE100A: This device complies with part 15 of the FCC rules.
Operation is subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
IMPORTANT! Any changes or modifications not expressly approved by the
party responsible for compliance could void the user’s authority to operate
this equipment.
NOTE : This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/ TV technician for help.
FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator and your body.
This transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter.
The TX-100-NC while in use must have a separation distance of at least 20 cm
from all persons, such as vehicle visor mount or wall mount, and must not be
co-located or operating in conjunction with any other antenna or transmitter.
FCC Caution: To assure continued compliance, any changes or modifications
not expressly approved by the party responsible for compliance could void the
user’s authority to operate this equipment.
(Example – use only shielded interface cables when connecting to computer or
peripheral devices).
Receiver Specifications
- Power Input: 12-24 Volt AC/DC
- Relays: 10A 250 VAC/ 28VDC
- 12V: 50mA (id l e ) 1A (transmit)
- 24V: 25mA (idle ) 500ma (transmit)
- Range: 1/2 mile (Through obstructions)
- Relays: 10A 250 VAC/ 28VDC
- Minimum / Maximum Temperature Range: -40°F to 185°F (-40°C to 85°C)
- Security Encryption: AES
POWER INPUT:
12 to 24 VOLTS AC/DC. – 1 AMP Minimum Always follow polarity when DC Power is
used.
BATTERY INPUT:
For 12 Volt Sealed Lead Acid (SLA) battery only. Solid GREEN LED indicates
battery charging. Momentarily flashing GREEN LED indicates battery is charged
and a trickle/conditioning charge is occurring.
TRANSMITTER SPECIFICATIONS
- Minimum / Maximum Temperature Range: -40°F to 185°F (-40°C to 85°C)
- Security Encryption: AES
- Range: 1/2 mile (Through obstructions)
- Power: 9V Lithiom Battery
- MODE DIP SWITCHES
- SWITCH 1 – Learn Mode
- SWITCH 2 – Not used
- SWITCH 3 – Not used
- TRANSMIT LEVEL
- Clockwise for more power when transmitting.
- Counterclock wise for less power when transmitting.
(Battery life will vary based on transmit power level set)
POWER DETAILS
The XRE-100 requires 1 amp of current draw to transmit at full power.
IMPORTANT – XRE REQUIRES AT LEAST 1AMP POWER SUPPLY
-
POWER INPUT:
Power Input: 12 to 24 VOLTS AC/DC. Always follow polarity when DC Power is used. 1 AMP Minimum -
BATTERY INPUT:
Battery Input: for 12 Volt Sealed Lead Acid (SLA) battery only.
Solid Green LED = Battery charging
Momentary Flashing LED = Battery is fully charged and a trickle/conditioning charge is occurring
LED INDICATORS
STATUS LEDs:
- RECEIVE – flashes GREEN momentarily when a valid radio transmission is received.
- TRANSMIT – flashes RED momentarily when the unit transmits a packet as a result of an Relay Input change event or handshake.
- STATUS/ PROG – flashes yellow patterns indicating status of the unit: pairing, error, etc.
- RUN – flashes ORANGE 1 second ON and 1 second OFF indicating the microprocessor is running.
- POWER LED – Glows solid orange when power is present. 5 volt relay supply, 3.3 volt logic supply, and VPA 3.6 volt power amplifier supply.
RELAY DIAGRAM AND WIRING
RELAY OUTPUTS
Relay Outputs – The Reign XRE-100 comes with 2-relay outputs. Relay 1 is the relay specified for use when the TX-100-NC is triggered. Relay 2 is used as a delay relay set for a certain amount of time to trigger after relay 1 is activated. Please refer to DIP switch 6 setting on page 8 for more information. The relay state is indicated by the Green ACTIVE LED above the relay.
DIP SWITCHES
MODE SWITCHES
-
SWITCH 1 – PROG (PAIR) – Use for programming TX-100-NC to XRE-100
-
SWITCH 2 – Not used
-
SWITCH 3 – Not used
-
SWITCH 4 – Not used
The behavior of the relay(s) is controlled by Dipswitch 5 & 6. -
SWITCH 5 = momentary or latching
-
SWITCH 6 = single or dual relays
DIPSWITCH 5 | DIPSWITCH 6 | FUNCTION |
---|---|---|
OFF | OFF | **** |
ON | OFF | **** |
OFF | ON | **** |
OFF | OFF | **** |
PROGRAM/TEST BUTTON:
To program turn DIP switch 1 to the on position in both the XRE-100 and
TX-100-NC. With both DIP switches turned on press the TX-100-NC transmit
button.
If done correctly the XRE-100 will flash yellow status LED 3 times and TX-100
will flash green LED 3 times
RELAY DELAY POTENTIOMETER:
Full counter clockwise is 1/2 second delay from relay 1 to relay 2
activation. Full clockwise is 10 second delay from relay 1 activation to relay
2 activation. To activate make sure DIP switch 6 is set to ON in the XRE-100
.
BATTERY BACKUP
12 Volt Sealed Lead Acid (SLA) battery only. Solid GREEN LED indicates battery charging. Momentarily flashing GREEN LED indicates battery is charged and a trickle/conditioning charge is occurring.
PAIRING UNIT IN THE FIELD
To program turn DIP switch 1 to the on position in both the XRE-100 and
TX-100-NC. With both DIP switches turned on press the TX-100-NC transmit
button.
If done correctly the XRE-100 will flash yellow status LED 3 times and
TX-100-NC will flash green LED 3 times.
TROUBLESHOOTING
TX-100-NC & XRE-100 units are not communicating:
- Check the Run LED on the XRE-100-NC. Normal operation will be orange LED flashing once a second.
- Press the button on the TX-100-NC. When pressed, the TX-100-NC will send a radio test packet and the RED TRANSMIT LED will illuminate. If the paired XRE-100 is online, it will acknowledge with a radio test packet – indicated by a momen-tary on the green receive LED.
If you do not see the transmit and receive LED lights activate:
- Power cycle the XRE unit.
- Move the XRE-100 unit to a higher location and avoid mounting on/in metal objects
If you are not getting the desired range between the TX-100 and XRE-100 unit:
- Ensure the XRE-100 has at least 1-amp of power dedicated to itself.
- Move the XRE-100 unit to a higher location – and avoiding mounting in/on metal objects
- Check that the potentiometer on the TX-100-NC board is turned to full power. (All the way to the left)
WARRANTY
The warranty period of this product is 24 months, beginning from the
manufacturing date. During this period, if the product does not operate
correctly, due to a defective component, the product will be repaired or
replaced at the sole discretion of Transmitter Solutions. This warranty does
not extend to the product casing which can be damaged by conditions outside of
the control of Transmitter Solutions.
EXCEPT AS SET FORTH ABOVE, TRANSMITTER SOLUTIONS MAKES NO WARRANTIES REGARDING
THE GOODS, EXPRESS OR IMPLIED, INCLUDING WARRANTY OF MERCHANTABILITY OR
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. BUYER MAKES NO RELIANCE ON ANY
REPRESENTATION OF TRANSMITTER SOLUTIONS, EXPRESS OR IMPLIED, WITH REGARD TO
THE GOODS AND ACCEPTS THEM
“AS-IS/WHERE-IS”. TRANSMITTER SOLUTIONS SELLS THE GOODS TO BUYER ON CONDITION
THAT TRANSMITTER SOLUTIONS WILL HAVE NO LIABILITY OF ANY KIND AS A RESULT OF
THE SALE. BUYER AGREES THAT TRANSMITTER SOLUTIONS SHALL HAVE NO LIABILITY FOR
DAMAGES OF ANY KIND, WHETHER DIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES,
INCLUDING INJURIES TO PERSONS OR PROPER-TY, TO BUYER, ITS EMPLOYEES OR AGENTS,
AS A RESULT OF THE SALE. BUYER ALSO AGREES TO HOLD TRANSMITTER SOLUTIONS
HARMLESS FROM ANY CLAIMS BUYER, OR ANY THIRD PARTY, MAY HAVE AS A RESULT OF
BUYER’S USE OR DISPOSAL OF THE GOODS. BUYER HAS READ THIS DISCLAIMER AND
AGREES WITH ITS TERMS IN CONSIDERATION OF RECEIVING THE GOODS.
- PH 866.975.0101
- FX 866.975.0404
- www.transmittersolutions.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>