LANGRY HT225-NB Digital Concrete Test Hammer Instruction Manual
- June 6, 2024
- LANGRY
Table of Contents
Digital Concrete Test Hammer
HT225-NB
Operating Instructions
JINAN LANGRUI DETECTION TECHNOLOGY CO. ,LTD.
PREFACE
Your choice of the products made by Jinan Langrui Detection Technology Co., Ltd. LANGRY is greatly appreciated. We are committed to delivering you excellent products and satisfied sales services. Please carefully read the instructions prior to use.
- The instructions are prepared to provide the correct and complete descriptions of related products and data. However, we do not guarantee that there are no errors or omissions. Therefore, we will not bear responsibility for any resulting consequences.
- ANGRY keeps the right of updating the instructions without prior notice.
- ANGRY bears no responsibility for possible losses from data deviation or incorrect testing conclusions arising from instrument failure and other errors.
- When the instrument is put into operation, it means that you have carefully read and had a full picture of all terms in the instructions, and you have fully agreed to all the terms in the instructions.
- ANGRY will not bear responsibilities for all the signed agreements violating the statement during the sales and services process not involving ANGRY.
Testing data processing basis: synchronous built-in “Technical specification for inspecting of concrete compressive strength by rebound method” (JGJ/ t23-2011) EN 12504-2 and ASTM C 805.
Technical Parameters
Memory quantity: 240 components
Standard impact energy:2.207 J
Spring stiffness:785±30.0N/m
Pointer length: 20.0 ± 0. 2mm
Friction of pointer: 0.65 ± 0. 15N
Spherical radius of bouncing rod: 25±1.0mm
Operating length of spring: 61.5±0.3mm
Take off position of Bounce hammer: scale “0” + 1
Rebound number on anvil:80±2
Consistency of sampling indication: ≦±1
Working temperature: – 4 ℃ ~ + 40 ℃
Display: 3.12 “OLED
Communication rate: 115200bps
Battery power supply: 2300 ma lithium-ion battery
Operating Instructions
-
KEYS
ok KEY: Performed the confirmation or cancel selected command
c KEY: Generally used for direct return or exit operations
KEY: In general, it is used to move the cursor in the screen and adjust the value of the selected position item.
KEY: For on/off operation, long press 2s to start -
Interface Design
All functions of the instrument are started from the main menu interface.
The main menu contains five sub-modules: setting, deleting, sampling, viewing, and shutting down.
2.1 Sampling Interface
In the main menu interface, select the sampling icon, Press the **ok**
key to
enter the sampling interface.
Sampling interface button c
key Pop-up Menu as shown in the figure, The
first item is to delete the last rebound value; the second item is to set
parameters; the third item is to exit sampling, At this time, press the
c
key to return to the sampling interface to continue sampling .
Press the key to select the second item, Press the ok
key to enter the
sampling parameter setting interface.
The sampling parameter setting menu includes continued sampling, number of
measuring points (American Standard and European standard are not allowed to
be modified), carbonization value, Impact Angle, detection surface, Allowable
minimum, and maximum.
Press the c
key on the sampling parameter setting interface to return to
the sampling interface.
After the completion of sampling, the system alarms and automatically jumps to
the sampling completion interface. The component data is saved. Press the
c
key to switch to the sampling selection interface. Select continue
sampling or modify parameter sampling by key. At this time, press the c
key to return to the main menu interface.
2.2 System Setup Interface
Select the Settings icon in the main menu interface, press the ok
key to
enter the system setting interface. There are 7 options. They are backlight
delay, unit, system time, curve, voice switch, age, a Correction factor of
test block size.
Backlight delay can be adjusted by key, and the range is the 20s-80s.
Compressive strength units: MPa, psi, and kg / cm².
Select the time icon, press the ok
key to enter the system time
adjustment interface. When adjusting the time, press the key to select the
part to be adjusted. Press the key to adjust the value.
After adjustment, press the c
key to return to the system setting
interface.
Curve Settings can be selected as JGJ23-2011, ASTM C 805, EN 12504-2, and
custom curves. If set as a custom curve, the maximum number of sampling points
can be set to 400 during sampling.
Need to slow down the Recoiling speed when the voice is turned on.
There are two options for age: 7 days and 14-56 days.
There are three correction factors of test block size according to different
sizes:1.0, 0.95, and 0.8. After the calculation, the strength value is
corrected.
2.3 Deleting Data
After the delete icon is selected in the main menu interface, Press the
ok
key to enter the deletion confirmation interface.
Once this command is executed, all component data in memory will be deleted
and cannot be recovered. For the sake of insurance, The instrument will be
confirmed by a confirmation screen, so be careful!
2.4 Viewing Interface
After the view icon is selected in the main menu interface, press the ok
key to enter the viewing interface.
The viewing interface is the same as the sampling completion interface. The
third item in the status bar of the interface is the number of current
components.
Press the key to increase or decrease the number of current components, in
order to view all component data.
Press the ok
key in the viewing interface to select the carbonization
depth value.
Press the key to change the carbonization depth value.
Press the **c**
key in the viewing interface to return to the main menu
interface.
2.5 Shutting Down.
After the shutdown icon is selected in the main menu interface.
Press the ok
key and the system will prompt to shut down. If you forget
to shut down, the system will shut down automatically after the shutdown
delay, and give an alarm prompt. Press any key at this time to cancel the
shutdown.
Manufacturer warranty
ANGRY guarantees that the tool is free from defects in materials and manufacturing processes when it leaves the factory, and the warranty is valid only if the user correctly installs, operates, maintains, and cleans the tool in accordance with Langry’s operating instructions. The warranty covers the free replacement or repair of damaged parts during the whole service life of this tool. If the parts need to be repaired or protected due to normal wear and tear, they are not covered by the warranty.
Other claims are not covered by the warranty unless there is a different provision under the specific law of the customer’s country. In particular, angry shall not be liable for any direct, indirect, incidental, or inevitable damage, financial loss, or additional expenses caused by or related to the improper use or abuse of this tool. Expressly exclude implied warranties of merchantability and fitness for a particular purpose.
In case of repair or replacement, the tool or relevant parts shall be sent to Larry’s market organization immediately after the failure is determined.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>