DESCRIPTION & OPERATION:
815 Center Inlet Series hot water booster centrifugal magnetic drive pumps are built to handle liquid transfer in heating and cooling operations. Contact the factory for application assistance. Pumps are not self-priming, lack a suction lift, and thus require a flooded suction. Pumps cannot be run dry.
INSTALLATIONS:
Pumps should be installed with the pump housing arrow pointing in the direction of flow within the system. If the arrow indicating flow is not in the direction required, remove the housing screws holding the housing to the motor bracket and rotate the housing assembly as required. Replace the screws and tighten. The pump is composed of a wet end assembly which can be separated by unscrewing the housing screws. The pump will then separate into 2 parts. The liquid will be contained within the wet end assembly unless the rear housing screws on the rear housing are loosened.
GENERAL SAFETY INFORMATION:
Follow all local safety codes & the Occupational Safety and Health Act (OSHA).
Make certain that the power source conforms to the requirements of your
equipment. Always disconnect power source before performing any work on or
near the electric motor. Caution must be exercised to relieve any pressure in
the system & in draining hot water from the pump or the system.
ELECTRICAL: Motors are available in different electrical configurations such
as 115V 60 Hz or 230 Volt 50/60 Hz, 1 Phase. The motors are U.L. listed and
rated for continuous duty. The 115V has a 6 foot cord and plug, the 230V has a
3 foot cord.
Specifications| | 815-BR-C| 815-PL-C| 815-SS-C|
---|---|---|---|---|---
Product| 115V| 0809-0017-0400| 0809-0188-0100| 0809-0198-0100
230V| 0809-0017-0500| 0809-0188-0200| 0809-0198-0200
Inlet-Outlet| | 3/4”MPT-1/2”MPT| 3/8”FPT & 3/4”MPT-1/2”MPT| 3/4”MPT-1/2”MPT
Max Internal Pressure| | 150PSI (1034 kPa)| 50PSI (344 kPa)| 150PSI (1034 kPa)
Max Liquid Temperature| | 250F (121C)| 250F (121C)| 250F (121C)
| 60Hz| 50Hz|
| Max Flow| Max Head| Electrical| Max Flow| Max Head| Electrical| Packed
Model| GPM| LPM| FT| PSI| M| Ph| V| A| HP| kW| RPM| GPM| LPM| Feet| PSI| M|
Ph| V| A| HP| kW| RPM| Pounds
815-BR-C| 8| 30.3| 18.6| 8| 5.7| 1| 115 or 230| 0.5 or 0..3| 1/25| 0.029|
3450| 7.9| 30| 13.5| 5.8| 4.1| 1| 115 or 230| .0.4 or 0.3| 1/25| 0.029| 2850|
6
815-PL-C| 8| 30.3| 18.6| 8| 5.7| 1| 115 or 230| 0.5 or 0..3| 1/25| 0.029|
3450| 7.9| 30| 13.5| 5.8| 4.1| 1| 115 or 230| .0.4 or 0.3| 1/25| 0.029| 2850|
5
815-SS-C| 8| 30.3| 18.6| 8| 5.7| 1| 115 or 230| 0.5 or 0..3| 1/25| 0.029|
3450| 7.9| 30| 13.5| 5.8| 4.1| 1| 115 or 230| .0.4 or 0.3| 1/25| 0.029| 2850|
6
All specifications & data are based on pumping water & are intended as a
guideline only. Specifications may vary with different motors.
815 Center Inlet
815-BR- C | 815-PL- C |
---|---|
Item | Part Number |
Description
A| 0923-0003-1000| 4| #8-32 x 1 Lg. Screw (Steel)| A| 0923-0003-1000| 4| #8-32
x 1 Lg. Screw (Steel)
B| 0809-0142-0000| 1| Pump Housing (Bronze)| B| 0809-0179-0100| 1| Pump
Housing (Polysulfone)
C| 0809-0165-1000| 1| 0.070 CS x 2.441 ID O-Ring (Silicone)| C|
0809-0027-1000| 1| 1/16 CS x 2-3/8 ID O-Ring (Silicone)
D| 0809-0043-1000| 1| Thrust Washer (Teflon)| D| 0809-0043-1000| 1| Thrust
Washer (Teflon)
F| 0809-0214-1000| 1| Left-Hand Thread (Stainless Steel)| E| 0809-0161-1000|
1| “D” Flat Shaft ( Stainless Steel)
G| 0809-0107-0200| 1| 2-5/32” Impeller (Ryton/Teflon/Glass)| G|
0809-0107-0200| 1| 2-5/32” Impeller (Ryton/Teflon/Glass)
H| 0809-0012-1000| 1| Rear Housing (Stainless)| H| 0809-0012-1000| 1| Rear
Housing (Stainless)
I| 0135-0040-1000| 8| #8-32 x 3/8Lg. Screw (Stainless)| I| 0135-0040-1000| 8|
8-32 x 3/8Lg. Screw (Stainless)
J| 0125-0083-0100| 1| Drive Magnet| J| 0125-0083-0100| 1| Drive Magnet
K| 0858-0004-1000| 4| #8 Washer (Stainless)| K| 0858-0004-1000| 4| #8 Washer
(Stainless)
L| 0809-0058-1000| 1| Motor Bracket (Plastic)| L| 0809-0058-1000| 1| Motor
Bracket (Plastic)
M| 0809-0218-1000| 1| Motor 115V, 50/60Hz, 6 foot cord and plug| M|
0809-0218-1000| 1| Motor 115V, 50/60Hz, 6 foot cord and plug
N| 0809-0124-1000| 1| Motor 230V, 50/60Hz, 3 foot cord| N| 0809-0124-1000| 1|
Motor 230V, 50/60Hz, 3 foot cord
815-SS- C| LUBRICATION: The motor should be oiled at least
once a year at the start of the heating season with 4 or 5 drops of SAE 20
weight non-detergent oil in eachbearing. If the pump is used daily, it should
be oiled every six months. Do not over oil. DISASSEMBLY & REASSEMBLY:
The motor can be removed from the wet end as-sembly without draining the
liquid from the system. To do so remove four housing screws and slide the
motor assembly away. If parts inside the wet end assembly must be removed,
isolate the pump or drain the system. When the system isdrained and cool,
remove the four screws from the rear of the housing. The rear housing can now
be removed. Remaining pump parts can be removed. Replace any worn or damaged
parts. Replace the O-ring anytime the rear housing is removed.
A| 0809-0205-1000| 4| #8-32 x 1 Lg. Screw (Stainless)
B| 0809-0150-0010| 1| Pump Housing (Stainless Steel)
C| 0809-0165-1000| 1| 0.070 CS x 2.441 ID O-Ring (Silicone)
D| 0809-0043-1000| 1| Thrust Washer (Teflon)
F| 0809-0214-1000| 1| Left-Hand Thread (Stainless Steel)
G| 0809-0107-0200| 1| 2-5/32” Impeller (Ryton/Teflon/Glass)
H| 0809-0012-1000| 1| Rear Housing (Stainless)
I| 0135-0040-1000| 8| #8-32 x 3/8Lg. Screw (Stainless)
J| 0125-0083-0100| 1| Drive Magnet
K| 0858-0004-1000| 4| #8 Washer (Stainless)| Materials in contact with the
liquid:
L| 0809-0058-1000| 1| Motor Bracket (Plastic)| 815-BR-C: Bronze,
Stainless Steel, Ryton/Teflon/Carbon, Silicone, Teflon
M| 0809-0218-1000| 1| Motor 115V, 50/60Hz, 6 foot cord and plug|
815-PL-C: Polysulfone, Stainless Steel, Ryton/Teflon/Carbon, Silicone,
Teflon
N| 0809-0124-1000| 1| Motor 230V, 50/60Hz, 3 foot cord| 815-SS-C:
Stainless Steel, Ryton/Teflon/Carbon, Silicone, Teflon
NOTE: Contact Factory for other materials
and/or parts not listed.
Special voltage motors are available upon special order.
_ _LIMITED WARRANTY__ : March pumps are guaranteed only against defects
in workmanship or materials for a period of one year from date of manufacture
pumping water. For the complete warranty and to register online go to
www.marchpump.com/warranty-registration
0809-0238-2000-REV 3.21.2022
1819 PICKWICK AVE., GLENVIEW, IL 60026-1306, U.S.A
PHONE: (847) 729-5300 –
FAbX: (847) 729-7062