Nuvair 3800H Auto Drain Timer Instruction Manual
- June 3, 2024
- Nuvair
Table of Contents
Nuvair 3800H Auto Drain Timer
If you have any questions on this equipment, please contact Technical Support
at:
Nuvair 1600 Beacon Place
Oxnard, CA 93033 USA
Phone: +1.805.815.4044
Fax: +1.805.486.0900
Email: info@Nuvair.com
Hours: Monday through Friday
8:00 AM to 5:00 PM Pacific Time
WARNING
This Operation Manual contains important safety information and should always
be available to those personnel operating this equipment. Read, understand,
and retain all instructions before operating this equipment to prevent injury
or equipment damage. Every effort was made to ensure the accuracy of the
information contained within. Nuvair, however, retains the right to modify its
contents without notice. Under Nuvair’s system of continuous improvement,
certain components may be updated or changed as higher quality or more
efficient parts and assemblies become available. Nuvair will make every effort
to update manuals as parts and functional aspects change. However, the look or
location of components on your product may differ from those in this manual if
improvements have been made that do not affect the functionality or
operational procedures. Units pictured may also be equipped with different
options than those on your product. In this case, the basic operational and
maintenance guidelines will still apply. If you have problems or questions
after reading the manual, stop and call Nuvair at +1.805.815.4044 for
information.
Introduction
This manual will assist you in the proper identification and operation of Nuvair auto drain timers. Please be sure to read the entire manual.
Symbol Conventions
This manual uses certain words and symbols to call your attention to
conditions, practices or techniques that may directly affect your safety. Pay
particular attention to the information introduced by the following symbols or
words:
Nuvair Auto Drain Timer Operation
Solenoid valve timers can be installed on gas-, diesel-, or electric-powered
compressors manufactured by Nuvair. The typical gas-powered compressor timer
installation looks like Figure 1. Typical diesel- or electric-powered
compressor timer installations look like Figure 2.
Typical for Gas Engines
If your auto drain solenoid timer valve has a fitting on the bottom of the
solenoid, like the one pictured in Figure 1, your timing settings are:
- [ON] for 5 seconds
- [OFF] for 8 minutes
Setting Gas Engine Timers
If you have the typical GAS ENGINE TIMER setup (as illustrated in Figure 1), please follow these instructions to program your auto drain timer:
- Press the [MODE] button until “ON-OFF” appears.
- Press [ENTER].
- Press [ENTER] until the far-right digit flashes.
- Press [ADD] until it reads “5”. The display will read “00:00:05”.
- Press [ENTER].
- Press [ENTER] until the flashing digit is on the third digit from the right.
- Press [ADD] until “8” appears. The display will read “00:08:02”.
- Press [ENTER] until the “2” starts flashing.
- Press [ADD] until the display reads “0”.
- Press [ENTER].
- The screen will display “ON-OFF” again as the unit saves settings.
- Once the new settings are saved, the timer will start counting.
Typical for Diesel Engine and Electric Motors
If your auto drain solenoid timer valve has a fitting going into the side of
the solenoid, like the one pictured in Figure 2, your timing settings are:
- [ON] for 8 minutes
- [OFF] for 5 seconds
If you have the typical GAS ENGINE or ELECTRIC MOTOR TIMER setup (as illustrated in Figure 2), please follow these instructions to program your auto drain timer:
- Press the [MODE] button until “ON-OFF” appears.
- Press [ENTER].
- Press [ENTER] until the third digit from the right flashes.
- Press [ADD] until “8” appears. The display will read “00:08:02”.
- Press [ENTER] until the “2” starts flashing.
- Press [ADD] until the display reads “0”.
- Press [ENTER].
- Press [ENTER] until the far-right digit flashes.
- Press [ADD] until the display reads “5”. The display will read “00:00:05”.
- Press [ENTER].
- The screen will read “ON-0FF” again as the unit saves settings.
- Once the new settings are saved, the timer will start counting.
Manufacturer Instructions
This section contains unedited operating instructions from the 3800 solenoid valve timer manufacturers.
Functions
- Adopts flame retardant engineering plastic shell, the solenoid valve timer is safe with high strength.
- Controlled by a microcomputer chip, its timing accuracy is high.
- Equipped with an LED screen, the timer features of night vision function.
- Timing set range: 1Sec~99h59min59Sec, bidirectional adjustable
- Mode: Circulation mode (two: switch on first and then switch off, or switch off first and then switch on) One-time mode (one: start at set time)
- Power supply: High voltage AC/DC, 110~240V (XY-3800H); Low voltage AC/DC, 7~36V (XY-3800L)
- The IP grade of this digital timer is IP65.
- Supports standard DIN43650A input/output interface.
- LED light indicates the state of ON and OFF.
- Applications: solenoid valve and other devices needed to set timing.
Screen Indication
- The screen indicates ON―OFF, it is the mode of a switch on first and then switch off.
- The screen indicates OFF―ON, it is the mode of switch off first and then switches on.
- The screen indicates ON which means switch on first, the cycle time is 1Sec~99h59min59Sec, it is the one-time mode.
Mode and Time Saving
The solenoid valve timer is at factory settings when you use it at the
first time, after power on, the timer is at an “ON-OFF” circulation working
state. The time of ON and off is both 2 seconds countdown (indicates “0 0 0 0
0 X”, from which X is a decreasing number). If you want to change the mode and
time, press the MODE key which shows “ON-OFF”, press the MODE key again it
will show “OFF―ON”, and then you can switch to the mode of “ON”, choose the
function mode you wanted and press ENTER key to confirm the setting mode,
after that you can start to set the time parameters. When you set the time
parameters at the state of “ON” (indicates “X X X X X X”), the first digit of
the left side starts to flash, that means you can start to set the time, press
ADD key for setting increasing time, and then press ENTER key to confirm,
after that the second digit of the left side starts to flash, at this time,
you can do the same thing to set all of the six bit data when you finish all
of the settings, you can start to set the time parameters at the state of
“OFF”. All the setting modes are the same as the state of “ON”. When you
finish all the setting modes, the timer screen flashes the mode of “ON-OFF” 4
times, and then the timer enters into the working state which is set. When you
set up parameters, the system stops working, it will get back to work until
you finish the settings; if you do not press ENTER to confirm and exit the
setting mode directly, the system is still working according to the settings
previously. (The above parameters are taken as an example at “ON-OFF” mode,
the other modes are same as which.)
Other Functions
Reset press the RESET key, the digital timer will stop currently working, and
then start to cycle working according to the parameters that have been set.
Note: this kind of timer is divided into two types: high voltage type and low
voltage type. Please choose it according to your actual needs.
Specifications
Nuvair
- Phone +1.805.815.4044
- Fax +1.805.486.0900
- Address 1600 Beacon Place
- Oxnard, CA 93033 USA
- Email info@nuvair.com
- Website www.Nuvair.com
References
- NUVAIR: Breathing Air Systems, Industrial Compressors, Nitrox
- NUVAIR: Breathing Air Systems, Industrial Compressors, Nitrox