SAFETY WARNINGS

CAUTION!

  • This product is intended for domestic use only, and must be used in accordance with the instructions for use provided. Do not use for purposes other than those indicated (sterilising feeding bottles, soothers and all breast feeding accessories). Any other use is to be deemed improper and therefore dangerous.
  • The appliance is intended for indoor use only; do not leave it exposed in the sun, rain and/or any other atmospheric conditions.
  • This appliance is not intended for use by children. Keep the appliance and the power cord out of the reach of children.
  • Please ensure that children do not play with the appliance.
  • The appliance can be used by persons with reduced physical, sensory or mental capabilities, or with no prior experience or knowledge, provided that they are supervised by a person responsible for their safety or have been instructed on how to safely use the appliance and have understood the risks involved.
  • Should the appliance be sold by the original owner or given to third party users, instructions for the safe use of the appliance must be provided to them, and they must have understood the hazards involved, by reading the user manual and in particular the safety warnings contained in it, which should always accompany the appliance.
  • Warning : for safety reasons the appliance must always be connected to an electricity system which has efficient earthing connections.
  • Only place the appliance on flat, level surfaces which are out of the reach of children.
  • Never place the appliance directly on or near hot surfaces, hobs or hotplates, or on to delicate surfaces or surfaces that may be sensitive to humidity and/or heat.
  • Never place objects or components directly on to the heating plate.
  • Pay attention to the parts marked with the symbol which indicates that they may reach high temperatures during use.
  • When in use, the appliance becomes extremely hot as it produces boiling steam. Always take maximum care not to remove the lid from the appliance and/or to keep the arms and face well away from the steam outlet on the lid as the steam released could cause burns.
  • After completing the sterilising cycle, the water contained in the appliance and the upper surface may be very hot. Always take great care to prevent all risks of burns!
  • Warning : wait for at least a few minutes at the end of each sterilising cycle before removing the lid and always do this carefully to prevent boiling steam or drops of extremely hot water from exiting the appliance and causing burns.
  • Warning : be sure that no drops spill on to the connector or the power cable, either when filling the tank before the cycle or when removing the lid at the end of the cycle.
  • Do not obstruct the steam outlet located on the upper part of the lid.
  • Never immerse or wet the plug, appliance or power cable with water or other liquids.
  • Do not pull on the power cable or the appliance to unplug the appliance from the mains.
  • Check that the power cable is always unplugged from the mains socket and that the appliance is cold before moving it, cleaning it, storing it, doing maintenance work or in between warming cycles if left unattended.
  • The cleaning and maintenance of the product must be carried out by the user and not by children and/or people with reduced mental capabilities or lacking experience or the required knowledge.
  • These instructions are available on www.chicco.com

MICROWAVE CONFIGURATION

  • Only place microwave-safe items/components to be disinfected in the appliance. If you have any doubts check with the manufacturer of these items/components whether they are microwave-safe.
  • Do not place products containing nylon or metal in the microwave steriliser.
  • Do not place the steriliser in traditional ovens.
  • When using combined microwave ovens, check that the grill and/or crisp mode functions are OFF. Also check that the grill is cold and that the crisp plate is not inserted in the oven.
  • When the sterilization cycle is over, always use suitable utensils for protecting your hands from heat to extract the sterilizer from the microwave.
  • Warning : wait for at least a few minutes at the end of each sterilising cycle before removing the lid and always do this carefully to prevent boiling steam or drops of extremely hot water from exiting the appliance and causing burns.

CAUTION

  • Do not leave the appliance, its accessories and any packaging materials (plastic bags, cardboard boxes, etc.) within the reach of children as they are not toys and can be hazardous.
  • Before using the appliance, always make sure that neither the product nor its components are worn or damaged. If the appliance is damaged, do not use it and contact a qualified technician or your dealer.
  • Immediately after the sterilisation cycle, the objects inside the appliance are very hot. Always handle with extreme care! Allow them to cool down before handling them.
  • Warning! If there is a power blackout while the appliance is working, the sterilisation cycle may be interrupted before completion. In this case, the sterilisation of the products in the appliance might not be sufficient.
  • To disconnect the appliance from the power supply, always switch it off, moving the main ON/OFF switch to 0 (OFF) and disconnect the plug from the mains socket when the steriliser is not in use.
  • Do not attempt to open or repair the appliance. The appliance can only be opened with special tools. The power cable must only be replaced with another identical power cable to the one supplied with the appliance; this operation must only be performed by expert technicians or by Artsana S.p.A.
  • Do not place objects that are not suitable for hot sterilisation inside the steriliser. Please check that the rated voltage on the steriliser (see indications on the plate under the appliance) corresponds to the mains voltage supply you intend to use.
  • Connect the appliance to a mains socket that is easy to access.
  • Never use the appliance without inserting the component holder rack first.
  • Never use the appliance without water in the heating tank.
  • To carry out a sterilisation cycle, do not pour any liquids other than drinking water into the container.
  • Artsana S.p.A. cannot be held responsible for damage to people and things should items/components non compatible with microwaves or hot sterilisation be placed in the appliance, or should the product be connected to the mains supply in a way that does not conform with the legislation in force and/or the instructions provided on the plate present on the appliance or in the instruction manual.
  • If in doubt about the interpretation of the contents of this instruction manual, please contact your dealer or Artsana S.p.A.

CLEANING AND MAINTENANCE

  1. Allow the appliance to cool down before handling it.
  2. Empty out any remaining water (fig. 10) taking care, in the FULL SIZE and COMPACT configurations, not to wet the connector and/or power cord (f ).
  3. Dry the heating plate/container (e) or the detachable base for microwaves (i), motor body (c), rack unit (b) and the lid (a) with a soft cloth.

REMOVING LIMESCALE

When the steriliser is used, it is normal for deposits of limescale to form on the heating plate/container (e) or in the detachable base for microwaves. These can vary in size and intensity according to the hardness of the water used in the appliance. An excessive deposit of limescale could reduce the performance of the appliance and damage it over the long term. It is therefore recommended that the appliance be descaled at least once a week, or each time that deposits of limescale are found on the heating plate/container (e) or on the detachable base for microwaves.

  1. Pour 130 ml of descaling solution into the hotplate/tank (e) or into the removable base for microwaves (i), following the instructions provided on the packaging.
  2. On the basis of the quantity of limescale to be removed, allow the solution to act for a maximum of 2 hours.. Never switch the steriliser on when the container is being soaked in the descaling solution.
  3.  Empty out the heating plate/container (e) or detachable base for microwaves (i).
  4. Remove any residue with a soft cloth and rinse several times, pouring 200 ml of drinkable tap water into the heating plate/container (e) or detachable base for microwaves (i) and empty out. Finally, dry the appliance carefully with a soft dry cloth before using it again.

WARNING : do not place the appliance under running water in its FULL SIZE and COMPACT configurations.

WARNING : Do not use tools, abrasive sponges, detergents, alcohol or solvents to carry out cleaning operations, as these may irreparably damage the steriliser.

INDEX OF SYMBOLS

| Appliance complies with the essential requirements of applicable EC Directives
---|---
| WARNING!
| Instructions for use
| Read the instructions for use
| For indoor use only
| WARNING! Hot steam
| Warning! Hot surface
| Do not dispose of this product as normal urban waste. Dispose of it according to the separate waste disposal regulations in force in your area
| Device certified and approved by IMQ (Italian Quality Brand Institute)

Modular electric steam steriliser

Dear customer,
We thank you and congratulate you on your choice. The modular electric steam steriliser adapts itself to the items to be disinfected occupying a small space in the kitchen thanks to the 3 configurations available: FULL SIZE, COMPACT and MICROWAVE.
It disinfects safely and securely with pure natural steam and no chemical substances, making it extremely convenient and easy to use.
The 3 configurations are compatible with all Chicco feeding bottles and breast pumps (the parts that can be subjected to hot sterilisation) and most of the other brands of feeding bottles and breast pumps on the market.
By using the MICROWAVE configuration it is possible to disinfect objects more quickly.
Easy to use, it can contain up to six 330 ml/11 oz feeding bottles of all Chicco lines with the relative accessories (cap rings, teats and cups) in the FULL SIZE configuration, and up to two 330 ml/11 oz feeding bottles with the relative accessories for the COMPACT and MICROWAVE configurations.
The number of feeding bottles of brands other than Chicco that can be placed in the appliance may be lower than that indicated here.
Please read these instructions carefully before use and keep them for future reference. Freephone number for calls from Italy 800 188 898.

DESCRIPTION (fig. 1)

a) Lid with handle and stream vents
b) Rack unit
c) Motor body
d) Base
e) Heating plate / container
f ) Appliance power cord with plug
g) Start cycke button*
g1) pilot light indicating that the appliance is in use
h) Main ON/OFF switch
i) Detachable base for microwaves
l) Power connector

WARNING: the Start Cycle button (g) is not an OFF button. To switch the appliance OFF and/or stop the sterilising cycle, simply press the main ON/OFF switch (g).

INSTRUCTIONS FOR USE SETTING UP THE CONFIGURATIONS OF THE STERILISER

The steriliser can be assembled for use in three different configurations:
FULL SIZE, COMPACT and MICROWAVE.

  1. FULL SIZE (fig. 2)
    To sterilise a maximum of six 330/300 ml/11 oz feeding bottles from the Chicco lines with their accessories. It is assembled by placing the following components one on top of another in order on the base of the appliance (d): motor body (c), rack unit (b) and lid (a).

  2. COMPACT (fig. 3) For sterilising up to two 330 ml/11 oz feeding bottles of all the Chicco lines with the relative accessories or other small objects, such as soothers. It is assembled by placing the following components one on top of another in order on the base of the appliance (d): rack unit (b) and lid (a).

  3. MICROWAVE (fig. 4) For sterilising up to two 330 ml/11 oz feeding bottles of all the Chicco lines with the relative accessories or other small objects, such as soothers, even faster. It is assembled by placing the following components one on top of another in order on the detachable base for microwaves (i): rack unit (b) and lid (a).

HOW TO PREPARE AND USE THE APPLIANCE FULL SIZE and COMPACT configurations – APPLIANCE CONNECTED TO THE MAINS POWER SUPPLY
Always carefully wash and rinse the objects to be sterilised before placing them inside the steriliser. Sterilise the TEATS, CAPS and ANTI-COLIC MEMBRANE (for Chicco Perfect5):

  • Detach the teats from the rings and position the teats on the rack unit (b) with the caps on top and the rings on top of the caps (fig. 5a, 5b, 5c).
  • For Chicco Perfect5 feeding bottles, remove the anti-colic membrane from the removable base and place the anti-colic membrane on the rack unit (b) (fig. 5d).

Sterilising FEEDING BOTTLES:

  • In the FULL SIZE configuration: Insert a maximum of six 330 ml/11 oz Chicco feeding bottles in the motor body (c). Feeding bottles should be positioned vertically with the neck facing down (Well-Being and NaturalFeeling lines) or facing up (Perfect5 line) with the removable base on top (fig. 6a and 6b).

Position the accessories on the rack unit (b) as specified above.

  • In the COMPACT configuration: Place up to two 330 ml/11 oz feeding bottles horizontally and position the relevant accessories as indicated for FULL SIZE mode, taking care not to obstruct the mouth of the bottle with the accessories so that steam can enter them freely.

WARNING : check that the accessories placed in the rack unit (b) do not prevent the lid from being closed properly (a). Before you use the appliance for the first time, always perform an empty sterilising cycle with no feeding bottles or other accessories inside.
During the first disinfecting cycles, the appliance could release a slight odour. This is not a sign of malfunction or damage and should be considered absolutely normal.

WARNING : When using the appliance for the first time, as soon as the main ON/OFF switch is turned on (h), the appliance could begin warming up immediately without you having pressed the cycle start switch (g) on the front. This is normal.

  1. Always place the appliance out of reach of children, on flat, level surfaces that are not sensitive to heat and/or humidity, and close to a mains socket that is easily accessible.

  2. Remove the lid (a), rack unit (b) and motor body (c) (fig. 7) and connect the power cord (f ) to the power connector (l).

  3. Place water in the heating plate/container (e) up to the water level mark indicated (fig. 8)
    Use in the FULL SIZE configuration: 130 ml
    Use in the COMPACT configuration: 90 m
    NOTE : The use of distilled water considerably reduces the formation of limescale on the heating plate.

  4. Assemble the steriliser in the configuration you require (for assembly instructions please see the section “Setting up the different steriliser configurations”).

  5. Place the objects to be sterilised inside the appliance (see the first paragraph of this section).

  6. Connect the power cable plug (f ) to the mains socket.

  7. Start the appliance by moving the main ON/OFF switch (h) to l (ON), then press the cycle start button (g). When the pilot light (g1) comes on, the appliance is heating up the water.
    NOTE : Sterilises in just 5 minutes, not including heating time.

  8. After completing the sterilising cycle, the pilot light (g1) will switch off automatically. Switch the appliance off by moving the main ON/OFF switch (h) to 0 (OFF) and disconnect the power cable plug (f ) from the mains socket.

  9. Wait a few minutes before removing the lid (a) and the sterilised objects. Always be very careful to prevent any boiling hot steam or drops of hot water leaking out and causing burns. Always wash your hands thoroughly before touching the objects that have been sterilised.

  10. Before starting a new sterilisation cycle, always wait until the appliance has completely cooled down.
    NOTE : In both configurations, FULL SIZE and COMPACT, the time of the sterilisation cycle may vary depending on the number, size and type of feeding bottles and accessories sterilised and the quantity of water placed inside the heating plate/container (e).
    NOTE : sterilised items will remain sterile inside the steriliser with the lid (a) on for about 24 hours. If the lid (a) is removed during or after use, the sterilisation status will be interrupted.

MICROWAVE configuration – APPLIANCE PLACED IN THE MICROWAVE
SAFETY WARNINGS
WARNING!

  • Glass feeding bottles can only be sterilised in microwave ovens when this option is expressly declared in the product specifications. In case of doubt, please contact your dealer or the manufacturer.
  • The times and powers indicated in the table STERILISATION TIMES AND POWERS must be strictly adhered to. Applying shorter times and weaker powers does not guarantee an effective sterilisation, while applying longer times and stronger powers could damage the steriliser together with its contents and the microwave oven itself.

The appliance is assembled by placing the following components one on top of another in order on the detachable base for microwaves (i), rack unit (b) and lid (a). In the MICROWAVE configuration, place the objects to be sterilised inside the appliance as indicated for the COMPACT configuration (please see the first paragraph of the section “How to prepare and use the appliance. Appliance connected to the mains power supply – FULL SIZE and COMPACT configurations).

  1. Always carefully wash and rinse the objects to be sterilised before placing them inside the steriliser.

  2. Place the detachable base (i) inside the microwave oven.

  3. Pour 80 ml of water into the central part of the detachable base (i ) (fig. 9).
    WARNING : do not pour less water. In this case the water may evaporate completely during heating with the risk of damaging the steriliser’s plastic components and rendering sterilisation ineffective.
    WARNING : do not pour more water. In this case, boiling water may leak out of the product after sterilisation and cause burns.

  4. Place the objects to be sterilised inside the rack unit (see the first paragraph of this section).

  5. Close the rack unit with the relevant lid (a) and place it in the microwave.

  6. Set the power on the microwave following the instructions in the table below.
    STERILISATION TIMES AND POWERS

Minutes

|

Power (Watt)

---|---

3

|

1000W +

4

|

Between 600W and 1000W

5

|

Between 440W and 600W

  1. When the sterilisation cycle is over, always use suitable equipment to protect your hands from heat in extracting the steriliser from the microwave.
  2. Wait for at least a few minutes at the end of each sterilising cycle, before removing the lid (a) and always do this carefully to prevent boiling steam or drops of extremely hot water from exiting the appliance and causing burns.

Always wash your hands thoroughly before touching the objects that have been sterilised.
NOTE : sterilised items will remain sterile inside the steriliser with the lid (a) on for about 24 hours. If the lid (a) is removed during or after use, the sterilisation status will be interrupted.

PROBLEMS AND SOLUTIONS

Problem

|

Possible Cause

|

Solution

---|---|---
** The steriliser does not finish the cycle / is noisy| Excessive limescale deposit on the heating plate/container (e).| Clean the heating plate/container (e) by re- moving the limescale with descaling solution (see the section “Removing limescale”).
The steriliser does not switch on.| There is no power.| Check that there is power in the mains.
The plug is not connected properly.| Verify that the plug has been connected properly and that it is in good condition.
The main ON/OFF switch (h) is in the
0 (OFF) position.| Move the main ON/OFF switch (h) to I** (ON).
The feeding bottles are stained at the end of the sterilisation cycle.| Excessive limescale deposit on the heating plate/container (e) or detachable base for microwaves (i).| Clean the heating plate/container (e) by re- moving the limescale with descaling solution (see the section “Removing limescale”).

N.B. IMPORTANT: If none of the solutions indicated above solves the problem, please contact Artsana Customer Service.

  • TECHNICAL FEATURES
  • Code: 00007391100000
  • Model: 06951_S
  • Power: 220-240V~ 50-60Hz
  • Power: 650 W
  • Made in China

THIS PRODUCT COMPLIES WITH THE DIRECTIVE 2012/19/EU
The crossed bin symbol on the appliance indicates that the product, at the end of its life, must be disposed of separately from domestic waste, either by taking it to a separate waste disposal site for electric and electronic appliances or by returning it to your dealer when you buy another similar appliance. The user is responsible for taking the appliance to a special waste disposal site at the end of its life. If the unwanted appliance is collected correctly as separate waste, it can be recycled, treated and disposed of ecologically; this avoids a negative impact on both the environment and health, and contributes towards the recycling of the product’s materials. . For further information regarding the waste disposal services available, contact your local waste disposal agency or the shop where you bought the appliance.

For the warranty for product defects see the specific provisions of applicable national laws in the country where purchased, if required. The warranty does not cover components subject to normal wear and tear.

ARTSANA reserves the right to change information described in this manual at any time and without notice. The reproduction, transmission, copying, as well as the translation into another language, of any part of these instructions, are absolutely forbidden without the previous written authorization by ARTSANA S.p.A.

DECLARATION OF EC COMPLIANCE:
Artsana S.p.A hereby declares that this appliance, brand Chicco mod. 06951_S, complies with all the essential requirements and other provisions set forth by the EU Directives 2014/30/EU (electromagnetic compatibility), 2014/35/EU (low voltage directive) and 2011/65/EU (RoHS). A full copy of the EC declaration can be requested from Artsana S.p.A. Via S. Catelli 1 – 22070 Grandate (CO) Italy.

Artsana S.p.A. – Saldarini Catelli 1 – 22070 Grandate (CO) Italy
www.chicco.com

References

Read User Manual Online (PDF format)