GENERAL LIFE MITRA 110S Digital Room Thermostat User Manual

June 3, 2024
GENERAL LIFE

GENERAL-LIFE-logo

GENERAL LIFE MITRA 110S Digital Room Thermostat

VIEW ALL GENERAL CONTROL THERMOSTAT MANUAL

GENERAL SPECIFICATIONS

MITRA 110S is a wired room thermostat. The user can adjust the room temperature with the required temperature and get more comfortable and economic heating.

  • Precise Temperature Measurement
  • Wired Connection
  • TPI Algorithm
  • ON/OFF Control

MITRA 110S AND EQUIPMENT

GENERAL-LIFE-MITRA-110S-Digital-Room-Thermostat-fig-
\(1\)

TECHNICAL DATA

Dimensions ( H / L / W ) 85mm / 125mm / 24mm
Operating Current 3V DC (2 x AAA alkaline battery)
Relay NO Switching Current 2A/30VDC (Resistive load)

0.5A/125VAC (Resistive load)

Temperature Measurement

Accuracy

| 0.1oC
Operating Temperature Range| (5oC) – (35oC)
Battery Life| 1 Year (2 x AAA)
Operating Temperature| (-10oC) – (+50oC)
Storage Temperature| (-20oC) – (+60oC)

ROOM THERMOSTAT

GENERAL-LIFE-MITRA-110S-Digital-Room-Thermostat-fig-
\(2\)

Room Thermostat Indicator LED Descriptions

If it blinks once The relay contact opens and the heating unit stops working.
If it blinks twice The relay contact closes and the heating unit starts.

ROOM THERMOSTAT PLACEMENT

Room Thermostat needs to be placed in the room which is used most frequently. For instance; the living room or lounge. Placing the Room Thermostat in a spot that has air circulation like the entrance of a room or the side of the window should be avoided. Also anywhere close to heating units such as radiators, stoves, and spots that get direct sun lights would not be suitable. Room Thermostat needs to be located above the floor 150 cm height. Few trials may be made to find the most convenient spot.

GENERAL-LIFE-MITRA-110S-Digital-Room-Thermostat-fig-
\(3\)

BATTERY PLACEMENT

Before starting, power off the device connected to the Room Thermostat and make sure that the energy is cut off.

GENERAL-LIFE-MITRA-110S-Digital-Room-Thermostat-fig-
\(4\)

As shown in the picture above, press the screwdriver forward from the space shown, bend the tabs and separate the front cover. Insert 2 new AAA alkaline batteries in the battery housing with the correct battery direction. Replace both batteries at the same time. Then align the front part of your Room Thermostat to the back and squeeze it towards the back.

WARNING!
When the product is not used for a long period (more than 15 days), remove the batteries. Otherwise, malfunctions that may occur would be out of warranty. Please throw your dead batteries into the waste bin for batteries.

ROOM THERMOSTAT WIRING DIAGRAM

GENERAL-LIFE-MITRA-110S-Digital-Room-Thermostat-fig-
\(5\)

WARNING!
Operations inside the boiler or related to the electrical installation must be carried out by persons with professional competence.

TPI ROOM THERMOSTAT WORKING LOGIC
Your Room Thermostat works with the TPI algorithm in the heating option. Room Thermostats using TPI technology predict when the temperature of your home will rise above or below the set temperature and turn the heating unit on and off accordingly. This ensures that your home stays at the temperature you set without maximum deviations up and down.

  • What is TPI?
    TPI technology is designed to ensure that you get the best possible energy efficiency from your heating system. It measures and applies the best possible timings to deliver and maintain your home at the set temperature level.

  • How does TPI work?
    Thanks to the advanced artificial intelligence technology found in the software, it adapts to the temperature change of the environment in which it is located. By creating a general temperature map of your home, it learns how long it takes to reach the desired room temperature and how to maintain this temperature. In this way, it provides minimum energy consumption by calculating how long your heating unit should work for.

  • What is the difference?
    In non-TPI room thermostats, the heating unit works and stops continuously until it exceeds the set temperature value. If the set temperature drops below a certain amount, the heating unit will work again. This creates greater temperature fluctuations and less energy control. TPI Room Thermostats, on the other hand, provide higher savings and comfort compared to On/Off room thermostats with the advantages it has.

TPI ROOM THERMOSTAT WORKING GRAPH

TEMPERATURE (ºC) Desired Temperature TPI Room ThermostatGENERAL-LIFE-MITRA-
110S-Digital-Room-Thermostat-fig- \(6\)

WHAT TO KNOW ABOUT TPI ROOM THERMOSTAT

  • If the placement of the TPI Room Thermostats is changed, the learning process will restart. The learning process should be considered as 7 days.
  • If the TPI Room Thermostats are de-energized (battery replacement), the learning process will restart. The learning process should be considered as 7 days.

FREQUENTLY ASKED QUESTIONS

Is my Room Thermostat compatible with my heating unit?
If your heating unit has on-off connections, your Room Thermostat is compatible. You can find information about your heating unit from your heating unit operating manual or from your heating unit service.

How will I connect my Room Thermostat to the heating unit?
We recommend that the connection between your Room Thermostat and the Heating unit should be made by professionally qualified persons.
2×0.75 mm cable is sufficient for the Room Thermostat – heating unit connection.

Connect one end of the cable pair to the room thermostat connection terminals stated in the user manual of the heating unit. Connect the other end of the cable pair to COM and NO inputs of the terminal inside the Wall Hanger of the Room Thermostat as shown in the “ROOM THERMOSTAT WIRING DIAGRAM” section.

The direction of the cable ends does not matter.

DECLARATION OF CONFORMITY

ISIPARK İÇ VE DIŞ TİC. İNŞ. ISITMA SİSTEMLERİ OTO. SAN.A.Ş.which Head Office and production site is located on Fatih Mah. 1188 Sk. No:13/A Sarnıç – Gaziemir – İZMİR – TÜRKİYE confirms and declares that the product marked with CE and its specifications below is covered by the provisions of the mentioned directive.

  • Brand: GENERAL Life
  • Product Name: MITRA 110S
  • Product Type: Digital Room Thermostat
  • Compatible Directives:
    • Electromagnetic Compatibility Regulation 2014/30/EU (EMC EN 61000-6-3: 2007 + A1: 2011, EN 61000-6-1: 2007) Low Voltage Directive 2014/35/EU (LVD EN 60730-2-9:2010, EN 60730-1:2011).

Additional Information: The mentioned product can be used with heating units with on/off output and compliance with the directives only covers the product. ISIPARK is not responsible for the entire system’s compliance with the directives. This statement is not valid if changes are made to the product without our approval.

WARRANTY CONDITIONS

  1. The warranty period starts from the invoice date and is warranted against manufacturing defects for 5 years.
  2. Devices and apparatus are delivered to the customer in working condition in our company. On-site commissioning is subject to a service fee.
  3. The repair of the devices and apparatus covered by the warranty is carried out in our company factory and should send by a contracted transportation company. In on-site services, the transportation and accommodation expenses of the service personnel belong to the customer. The shift fee during the transportation is added to the service fee and collected in advance.
  4. The maintenance of devices and apparatus is done in our company. For the maintenance of the devices and apparatus, the round travel fares belong to the customer.
  5. In case of malfunctioning of the devices and apparatus whose warranty period continues, it is tested in our company whether the malfunction is caused by a customer or manufacturer fault, and it is reported with a report issued by our company.
  6. In case of detection of manufacturer-induced errors of devices and apparatus whose warranty period continues, the customer can request a replacement or repair of the devices and apparatus at full expense by the manufacturer, unless it’s higher than the product’s price.
  7. In the event that the faults of the devices and apparatus whose warranty period continues are determined as caused by the customer, all expenses would belong to the customer.
  8. Customers should be aware of damages (if there is any) of the product and warn manufacturer since the day the warranty duration starts.If the customer do not warn the manufacturer with knowledge of the damage, the customer loses the rights of article 6.
  9. Malfunctions resulting from the use of devices and apparatus contrary to the matters stated in the User Manual are not covered by the warranty.
  10. Devices and their apparatus are out of warranty if they are beaten, broken or scratched by the customer.
  11. Damages resulting from the use of devices and apparatus belonging to other brands and models without the approval of the manufacturer are not covered by the warranty.
  12. Battery leakage and errors due to rust, oxidation, and liquid contact by working in acidic/humid environments are not covered by the warranty.
  13. When the product is not used for a long period (more than 15 days), remove the batteries. Otherwise, malfunctions that will occur are out of warranty.
  14. Damages that may occur during the transportation of devices and apparatus are not covered by the warranty. Customers can take transportation insurance.
  15. Damages caused by mains voltage/faulty electrical installation are not covered by the warranty.
  16. Devices and apparatuses are out of warranty for malfunctions caused by force majeure such as fire, flood, earthquake, etc.
  17. All of the devices and apparatuses, including all their parts, are under the warranty of our company.
  18. In case of malfunction of the devices and apparatuses within the warranty period, the time spent during the repair period is added to the warranty period. The repair period of the product cannot exceed 20 working days. This period starts from the date of notification to the service station of the malfunction related to the product or, in the absence of a service station, to the seller, dealer, agency, representative, importer, or manufacturer of the product. The consumer can report the problem by; phone, fax, e-mail, register and reply paid letter or a similar way. However, in the case of a conflict, the responsibility of proving is belongs to the customer. If the malfunction of the product is not repaired within 20 working days, the manufacturer-producer or importer; has to allocate another product with similar features to the use of the consumer until the repair of the product is completed,
  19. Although the consumer uses his/her repair rights,
    • If the product breaks down for 4 times in a year or 6 times in warranty duration and these problems effects the main purpose of the product. (starting from delivery time during warranty.)
    • Exceeding the maximum time required for repair,
    • In the event that the service station is not available if it is determined that the repair of the defect is not possible with the report prepared (in order) by one of the sellers, dealers, agencies, representatives, importers, or manufacturer, a refund or a price discount at the rate of defect can be requested.
  20. The customer can make complaints and appeals to consumer courts or consumer arbitration committees.
  21. The warranty document must be kept by the customer during the warranty period. If the document is lost, a second document will not be issued. In case of loss, repair and replacement of devices and apparatus will be made for a fee.
WARRANTY CERTIFICATE

Manufacturer
Title: ISIPARK İÇ DIŞ TİC. A.Ş.
Address: Fatih Mah. 1188 Sk. No:13/A Sarnıç Gaziemir İzmir-TÜRKİYE
Tel: +90 (232) 457 99 50
Fax: +90 (232) 457 91 22
E-mail: [email protected]

Authorized Signature:
Company Stamp:

Product

  • Type: Digital Room Thermostat Brand: GENERAL Life
  • Model: MITRA 110S
  • Warranty Period: 5 Years
  • Max. Time to Repair: 20 Days Bandrol and Serial Number:

GENERAL-LIFE-MITRA-110S-Digital-Room-Thermostat-fig-
\(7\)

ISIPARK reserves the right of changing product specifications and user manuals.

For all changes, you may visit generallife.com.tr.

Generallife MITRA 110S DIGITAL ROOM THERMOSTAT User Manual

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

GENERAL LIFE User Manuals