INKBIRD HM-058 Air Quality Detector User Manual

June 3, 2024
INKBIRD

INKBIRD HM-058 Air Quality Detector

Specifications

  • Product Name: Air Quality Detector
  • Model No: HM-058
  • Item No: IAQM-058
  • Detecting Items: CO2 / Temperature / Humidity / AQI / HCHO / PM2.5
  • Material: ABS/Acrylic/Electronic Components/Air Sensors
  • CO2 Range: 400~5000ppm
  • CO2 Accuracy: ± (50ppm+5%*Readout)
  • PM2.5 Range: 0~999μg/m³
  • HCHO Range: 0~999μg/m³
  • AQI Range: 0~99 ppm
  • Temperature Range: 0~55℃ (℃/℉ switchable)
  • Humidity Range: 0~99%RH
  • Battery Capacity: 1000mAh
  • Working Time: 3~5 Hours
  • Type-C Power Supply: 5V/2A
  • Wi-Fi Channel: IEEE802.11/b/g/n 2.4GHz
  • Bluetooth: BLE5.0
  • Working Current: 5V/500mA
  • Rated Power: 5W
  • Standby Current: <3mA
  • Size: 1238632mm
  • Weight: 300g

Precautions For Use

  1. This product should not be dipped in water, nor should it be placed in a high-temperature environment exceeding 60℃.
  2. This product belongs to a precision measuring instrument and shall not be dismantled without authorization.
  3. It cannot be measured in the environment of organic gas with too high a concentration for a long time.
  4. Built-in lithium battery, when measuring the air quality in the car, please do not put the carbon dioxide monitor with a lithium battery in the sun.

Operation Instruction

  • Power ON/OFF: Touch and hold the button for 5 seconds to turn the device on/off.
  • Mute the Alarm: When the device sounds an alarm, touch the button to temporarily stop the alarm. It will sound again after fifteen seconds.
  • Alarm Function: Under a no-alarming state, touch and hold the button for 5 seconds until you hear a short beep to turn on/off the alarm function. When the LED light is green, the alarm function is OFF; when the LED light is off, the alarm function is ON.

Please note that the alarming values are factory preset W. hether the CO2 value exceeds the standard is indicated by the expression icon and indicator light, as shown in the following table:

| |
---|---|---
Good| Normal| Bad
400-999ppm| 1000-1399ppm| over 1400ppm
No alarm| Alarm 5 times every 15s| Alarm 10 times every 15s

Wi-Fi Disconnection: Touch and hold theINKBIRD HM-058 Air Quality
Detector-8 button for 5 seconds until you hear a short beep, and the device will unbind the Wi-Fi connection with the mobile APP.
℃/℉ Selection: Touch the button to switch between ℃ and ℉.
Auto Calibration: After 24 hours of power on and ventilation, the device will automatically calibrate.

App Connection

Search the keyword “INKBIRD” in App store or Google Play, or scan the following QR code to download and install the APP. (If you have previously installed the app, please update it to the latest version.)

  1. Open the app and enter the login interface. You can log in by your Apple ID or Google ID. You can also click Register and use your email address as prompted to register.INKBIRD HM-058 Air Quality Detector-11
  2. Click the “+” in the upper right corner to add the device. Then, click the device icon on the app to start connecting.
  3. Choose a Wi-Fi network and enter the password. Then, click “Next” to the next step. Note: The device only supports 2.4GHz Wi-Fi networks.
  4. Make sure the device is turned on, then click “Next” to start the connection.
  5. Connection Succeeded.

Notes:

  1. During the connection process, it is necessary to ensure that the distance between the device and the mobile phone is within 30 meters, as Wi-Fi is a short-distance connection.
  2. During the connection process, please ensure that the device and the mobile phone are in the same Wi-Fi environment and only support the 2.4GHz Wi-Fi signal mode.
  3. Please make sure the Bluetooth of your phone is turned on before connecting.

Data Export

With the PC tool provided by the manufacturer, which is only compatible with the Windows system, we can view 720 pieces of data from the late 30 days on a Windows computer and export the data as a file for further investigation. Please use the included type-C data cable to connect the monitor to the computer.

Notes:

  1. Please download the PC tool from the support section of the INKBIRD website.
  2. Please check if your computer supports the CH340 serial port before use. This product supports CH340 serial ports 2/3/4/5, except serial port 1. If the CH340 driver has not been installed on your computer yet, please download it from the internet.
  3. The PC tool requires the device to be running for at least 24 hours.Otherwise, no data can be exported successfully.

How To Export Data

  1. Open the PC tool on your computer.INKBIRD HM-058 Air Quality Detector-17
  2. Select a CH340 serial port from the COM block, and then click “No link” to change to link status.INKBIRD HM-058 Air Quality Detector-18
  3. Click “Get Device Data” to upload the device data to the computer.INKBIRD HM-058 Air Quality Detector-19
  4. Click “Browse” to choose a save path, and then click “Save” to export the file.

INKBIRD HM-058 Air Quality Detector-20

Product Warranty

This item carries a 1-year warranty against defects in either components or workmanship. During this period, products that prove to be defective will, at the discretion of INKBIRD, be either repaired or replaced without charge.

INKBIRD TECH.C.L.
support@inkbird.com
Factory address: 6th Floor, Building 713, Pengji Liantang Industrial Area, NO.2 Pengxing Road, Luohu Disctrict, Shenzhen, China Office address: Room 1803, Guowei Building, NO.68 Guowei Road,Xianhu Community, Liantang, Luohu District, Shenzhen, China