INKBIRD IAQM-129-W Indoor Air Quality Monitor User Manual

June 1, 2024
INKBIRD

INKBIRD-LOGO

INKBIRD IAQM-129-W Indoor Air Quality Monitor

INKBIRD-IAQM-129-W-Indoor-Air-Quality-Monitor-PRODUCT

Product Information

  • Technical Specifications
    • Product Name: Inkbird Indoor Air Quality Monitor
    • Model Number: IAQM-129-W
    • Data Detection: AQI, CO2, PM2.5
    • Screen Size: 80mm x 120mm Built-in Li-Po Battery
    • Power Input: USB
    • WiFi Connection: Yes
    • Supporting: Android and iOS devices

Product Usage Instructions

  • Power On/Off
    • Press and hold the ECO button for 2 seconds to turn the device on or off.
  • Set Time & Date
    • Press the button twice quickly to enter the time setting, and the month number will flash.
    • Use the arrow buttons to adjust the numbers and press SET to confirm each selection.
    • Repeat the above steps for day, hour, and minute settings.
    • Set AQI / CO2 / PM2.5 Alarm Values and CO2 Auto Calibration
    • Press the SET button twice quickly to enter the alarm setting.
    • Adjust AQI alarm value, CO2 alarm value, and CO2 auto-calibration using arrow buttons and SET buttons to confirm.
    • For CO2 auto-calibration, switch on/off using the arrow buttons and SET buttons to confirm.
    • Adjust the PM2.5 alarm value using the arrow buttons and SET buttons to confirm.
  • WiFi Function On/Off
    • Press and hold the button for 2 seconds to turn on the WiFi function.
    • Press the button twice quickly to turn off the WiFi function.
    • Reset the WiFi connection by holding the button for 2 seconds when the WiFi is on.
  • ECO Mode
    • Real-time detection within 5 minutes of operation.
    • Detects once every 15 minutes after 5 minutes of inactivity.
    • Detects once every 1 hour after 1 hour of inactivity.
    • If out-of-range data occurs, the sensor reverts to state 1.
  • App Installation & Connection
    • Search the INKBIRD App on Google Play or App Store to download for free.
    • Alternatively, scan the provided QR code for direct download.

FAQs

  • Q: How do I reset the device?
    • A: To reset the device, press and hold the ECO button for 5 seconds until the device powers off. Then release the button and power it back on.
  • Q: Does the device support multiple user profiles?
    • A: No, the device does not support multiple user profiles. It operates as a single-user device.

TECHNICAL SPECIFICATIONS

  • Product Name Indoor Air Quality Monitor
  • Model Number IAQM-129-W
  • Data Detection Carbon Dioxide, Temperature, Humidity, AQI, HCHO, PM2.5, TVOC, PM10
  • Screen Size 14.1*6cm
  • Built-in Li-Po Battery 2700mAh
  • Power Input DC5V~12V
  • WiFi 2.4GHz
  • Connection Supporting WiFi+Bluetooth
  • Package Contents 1x Air Quality Monitor; 1x USB cable; 1x User Manual

PRODUCT INTRODUCTION

Product Appearance

INKBIRD-IAQM-129-W-Indoor-Air-Quality-Monitor-FIG-1
\(1\) INKBIRD-IAQM-129-W-Indoor-Air-
Quality-Monitor-FIG-1 \(2\)

Screen Information Description

INKBIRD-IAQM-129-W-Indoor-Air-Quality-Monitor-FIG-1
\(3\)INKBIRD-IAQM-129-W-Indoor-Air-
Quality-Monitor-FIG-1 \(4\)

OPERATION BUTTON DEFINITIONS

INKBIRD-IAQM-129-W-Indoor-Air-Quality-Monitor-FIG-1
\(5\)INKBIRD-IAQM-129-W-Indoor-Air-
Quality-Monitor-FIG-1 \(6\)

Note:

  • When the device is powered off, place it in a well-ventilated place, then press and hold both the ECO and SET buttons simultaneously, the device will enter the CO2 calibration mode, which takes 200 seconds.
  • During the CO2 calibration, please make sure that no one comes near the device to affect the calibration result.

OPERATION INSTRUCTIONS

  • Power On/Off
    • Press and hold the ECO button for 2 seconds to turn the device on or off.
  • Set Time & Date
    • Step 1: Press the button twice quickly to enter the time setting, the month number will flash.
    • Step 2: Press the or button to increase or decrease the number, then press the SET button to confirm.
    • Step 3: The day number will flash. Press the or button to increase or decrease the number, then press the SET button to confirm.
    • Step 4: The hour number will flash. Press the or button to increase or decrease the number, then press the SET button to confirm.
    • Step 5: The minute number will flash. Press the or button to increase or decrease the number, then press the SET button to confirm.
  • Set AQI / CO2 / PM2.5 Alarm Values and CO2 Auto Calibration
    • Step 1: Press the SET button twice quickly to enter the alarm setting, the AQI alarm value will flash.
    • Step 2: Press the or button to increase or decrease the number and press the SET button to confirm.
    • Step 3: After setting the AQI alarm value, the CO2 alarm value will flash. Press the or button to increase or decrease the number and press the SET button to confirm.
    • Step 4: After setting the CO2 alarm value, it will enter the setting of CO2 auto-calibration. The character C-OF (CO2 calibration off) or C-ON (CO2 calibration on) will flash. Press the or button to switch the CO2 auto-calibration function on or off, then press the SET button to confirm. Please note that the ON or OF character will pause for 2 seconds during setting, this is a normal phenomenon. Please be patient and wait for it to flash.
    • Step 5: The PM2.5 alarm value will flash. Press the or button to increase or decrease the number and press the SET button to confirm.
  • WiFi Function On/Off
    • Press and hold the button for 2 seconds to turn on the WiFi function.
    • Press the button twice quickly to turn off the WiFi function. When the WiFi function is on, press and hold the button for 2 seconds to reset the WiFi connection.
  • ECO Mode (when the ECO light is on)
1. After operating the device, the sensor will detect in real-time within 5 minutes;
2. After 5 minutes of inactivity, the sensor will detect once every 15 minutes;
3. After 1 hour of inactivity, the sensor will detect once every 1 hour;
4. If any operation or out-of-range data has occurred, the sensor will revert to state 1. When the ECO mode is off (the ECO light is off), the sensor detects data in real-time.
  *  **Note:** If there is no operation for 30 seconds, the unit will automatically save the setting and exit.

APP INSTALLATION & CONNECTION

  • Search the INKBIRD App from Google Play or App Store to get it for free, or you can scan the QR code below to download it directly.

NOTE:

  1. Your iOS devices must be running iOS 12.0 or above to download the app smoothly.
  2. Your Android devices must be running Android 7.1 or above to download the app smoothly.
  3. The device supports a 2.4GHz Wi-Fi router only.
  4. APP Location Permission Requirement: We need to obtain your location information to discover and add nearby devices. INKBIRD promises to keep your location information strictly confidential. Your location information will only be used for the location function of the App and will not be collected, used, or disclosed to any third party. Your privacy is very important to us. We will abide by relevant laws and regulations and take reasonable security measures to protect your information security.

Registration

  • Step 1: Registering an account is necessary before using the INKBIRD app for the first time.
  • Step 2: Open the app, select your Country/Region, and a verification code will be sent to you.
  • Step 3: Enter the verification code to confirm your identity and the registration is complete.

How To Connect

  • Step 1: Turn on both the Bluetooth and WiFi functions on your smartphone.
  • Step 2: Open the INKBIRD app and click “+” on the top right corner to add the device. Then, follow the app instructions to complete the connection.

Note:

  1. Make sure that the device is placed as close to the smartphone and router as possible during the connection process.
  2. All data exported from the application can only be in Celsius.

FCC

FCC REQUIREMENT

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules.

Operation is subject to the following two conditions:

  1. this device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, under Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used by the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

CUSTOMER SERVICE

This item carries a 1-year warranty against defects in either components or workmanship. During this period, products that prove to be defective will, at the discretion of INKBIRD, be either repaired or replaced without charge. For any problems in use, please feel free to contact us at support@inkbird.com. We will do our best to help you.

Warning:
Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTE:
This device complies with part 15 of the FCC Rules.

Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

FCC Statement:
This equipment has been tested and found to comply with the limits for a Class B digital device, under part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used by the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

ISED Statement:

This device complies with Part 15 of FCC Rules [ and contains license-exempt transmitter(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS Standard (s)].

Operation is subject to the following two conditions:

  1. This device may not cause interference; and
  2. This device must accept any interference received, including interference that may cause undesired operation

The digital apparatus complies with Canadian CAN ICES 3 (B)/NMB 3(B). This device meets the exemption from the routine evaluation limits in section 2.5 of RSS 102 and compliance with RSS 102 RF exposure, users can obtain Canadian information on RF exposure and compliance. This equipment complies with Canada’s radiation exposure limits set forth for an uncontrolled environment.

CONTACT

Factory address:

  • 6th Floor, Building 713, Pengji
  • Liantang Industrial Area, NO.2 Pengxing Road, Luohu
  • District, Shenzhen, China

Office address:

  • Room 1803, Guowei Building, NO.68
  • Guowei Road, Xianhu Community, Liantang, Luohu
  • District, Shenzhen, ChinaINKBIRD-IAQM-129-W-Indoor-Air-Quality-Monitor-FIG-1 \(10\)

Please keep this manual properly for reference. You can also scan the QR code to visit our official website for product usage videos. For any usage issues, please feel free to contact us at support@inkbird.com.

INKBIRD-IAQM-129-W-Indoor-Air-Quality-Monitor-FIG-1
\(11\)

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals