INKBIRD IAQM-128W Air Quality Detector User Manual

June 3, 2024
INKBIRD

Air Quality Detector
User ManualINKBIRD IAQM 128W Air Quality Detector
-

Specifications

  • Product Name: Air Quality Detector
  • Model NO: MH-128
  • Item No: IAQM-128W
  • Detecting Item: CO2/Temp/Hum/AQVHCHO/PM2.5/PM10/TVOC
  • Material: ABS/Acrylic/Electronic Components/Air Sensors
  • Carbon Dioxide: 400-5000ppm (t5Oppm + 5%)
  • PM10: 0-999pg/m3
  • PM2.5: 0-999pg/m3
  • TVOC: 0-9999ug/m3
  • HCHO: 0-9999pg/m3
  • AQI: 0-499
  • Temperature: 0-55T (t/°F switchable)
  • Humidity: 0-99%
  • Li-Battery: 2500mAh ( About 2 hours )
  • Type-C Power Supply: 5V/2A
  • Wi-Fi: IEEE802.11/b/g/n 2.4GHz
  • Bluetooth: BLE5.0
  • Display Size: 25*15cm (11.4 Inch)
  • Weight: 850g
  • Rated Power: 10W
  • Wi-Fi Supporting: Wi-Fi+BT CB3S (Optional)
  • Connecting Platform: INKBIRD APP / PC tool /Modbus connecting
  • RS4135 Input: 5V/1A
  • RS485 Transmission Rate: 10Mbps
  • Data Logger: Updated every 10 minutes, 30 days data storage
  • Flash Memory Capacity: 512 KB
  • Product Warranty: 1 Year
  • Package Content: lx Air Quality Monitor; 2x Support bars; lx Type-C Cable; lx Power Adapter, lx Wall Mount Accessories

Precautions For Use

  1. This product should not be dipped in water, nor should it be placed in a high-temperature environment exceeding 60°C.
  2. This product belongs to a precision measuring instrument and shall not be dismantled without authorization.
  3. It cannot be measured in the environment of organic gas with too high a concentration for a long time.
  4. Built-in lithium battery, when measuring the air quality in the car, please do not put the carbon dioxide monitor with a lithium battery in the sun.

Operation Instructions

INKBIRD IAQM 128W Air Quality Detector - 1

| Modbus icon| | Wi-Fi icon
---|---|---|---
| Alarm Icon| | Battery life
| LED indicator| | Power On/Off
| Alarm| | Wi-Fi Reset
| °F/C switcher| |

INKBIRD IAQM 128W Air Quality Detector - 2

  1. Power ON/OFF: Press and hold the button for 3 seconds to turn the device on/off.
  2. Alarm Function: Press the button to turn on the alarm function. The icon will appear on the screen. After the alarm is triggered, press the button again to mute and turn off the alarm, and the icon will disappear on the screen. When the device is powered on, the alarm function Is enabled by default.
    Please note that the alarming values are factory reset and are NOT settable. Whether the CO2 value exceeds the standard is indicated by the LED indicator light on the screen, as shown in the following table:Green| Orange| Red
    ---|---|---
    Good| Normal| Bad
    400-999ppm| 1000-1399ppm| over 1400ppm
    No Alarm| Alarm 5 times every 15s| Alarm 10 times every 15s
  3. WI-Fi Reset: Press and hold the button until you hear a beep to reset the Wi-Fi connec-tion.
  4. °F/°C Selection: Press the trF button to switch between and °C.
  5. Time Setting: The time on the device will be automatically calibrated and synced with your smartphone after the Wi-Fi connection. You can also connect the device to your computer and press the button via the PC tool to update the time.
  6. Fences all around the product can make the sensor fully contact the air.

App Connection

https://inkbird.com/pages/app-download

Search the keyword -INKBIRD” in App store or Google Play, or scan the following OR code to download and install the APR If you have previously Installed the app, please update it to the latest version.

  1. Open the app and enter the login interface. You can log in by your Apple ID or Google ID. You can also click Register and use your email address as prompted to register.INKBIRD IAQM 128W Air Quality Detector - 3
  2. Click the “+” in the upper right corner to add the device. Then, click the device icon on the app to start connecting.INKBIRD IAQM 128W Air Quality Detector - 4
  3. Choose a Wi-Fi network and enter the password. Then, click “Next” to the next step. Note: The device only supports 2.4GHz Wi-Fi networks.
  4. Turn on the device and press the,’ button on the device to reset the Wi-Fi connection, then click “Next” to continue.INKBIRD IAQM 128W Air Quality Detector - 02 
  5. Connection Succeeded.

Notes:

  1. During the connection process, it is necessary to ensure that the distance between the device and the mobile phone is within 30 meters, as Wi-Fi is a short-dis-tance connection.
  2. During the connection process, please ensure that the device and the mobile phone are in the same Wi-Fi environment and only support the 2.4GHz Wi-Fi signal mode.
  3. Please make sure the Bluetooth of your phone is turned on before connecting.

RS485(Modbus) Setting

Device Modbus is a general protocol whose ports remain open. With it, users can obtain data and set the save path. The external host can obtain all the data of 128W through the following data: CA 03 00 00 00 09 95 B7

  • Telecommunication Parameter Baud rate: 9600 Data Length: 8 bit Stop Bit: 1 bit Verification: no Equipment address: OxCA
  • Data Frame
Equipment address Function Starting Address Coil number CRC-16

Byte length of starting address and coil quantity are 2 bytes (MS byte is ahead of LS byte.)

  • Equipment Register.
Address Operation Details Remark
Ox0000 Read only Temperature, multiply by 10 times with hexadecimal. Such as
Ox0OFB, mean’s temperature is 25.1°C.
0x0001 Read only Humidity, multiply by 10 times with hexadecima.
Such as 0X0259, means humidity is 60.1%.
0x0002 Read only PM10, unit is ug/m3
0x0003 Read only PM2.5, unit is ug/m3
0x0004 Read only CO2, unit is PPM
Ox0005 Read only TVOC, unit is ug/m3
0x0006 Read only HCHO, unit is ug/m3
0x0007 Read only AQI
0x0008 Read/Edit CO2 warning value setting Optional
  • Telecommunication Example 03 command, to read device current temperature
    Sending : CA 03 00 00 00 01 94 71
    Answering: CA 03 02 00 FB 5C 17
    Data Analyse: 0x256+0xFB = 25.1°C

Export Data Using PC Tool

With the PC tool provided by the manufacturer, which is only compatible with the Windows system, we can view 4320 pieces of data from the late 30 days on a Windows computer and export the data as a file for further investigation. Please use the included type-C data cable to connect the product to the computer.

Notes:

  1. Please download the PC tool from the support section of the INKBIRD website.
  2. Please check if your computer supports the CH340 serial port before use. This product supports CH340 serial ports 3/4/5/X, except serial port 1 or 2. If the CH340 driver has not been installed on your computer yet, please download it from the internet.
  3. The PC tool requires the device to be running for at least 24 hours. Otherwise, no data can be exported successfully.
  4. Make sure that the device battery is sufficient to prevent the computer from charging the device.

How To Export Data

  1. Open the PC tool on your computer.INKBIRD IAQM 128W Air Quality Detector - 8
  2. Select a CH340 serial port from the COM block, and then click “No link” to change to link status.INKBIRD IAQM 128W Air Quality Detector - 9
  3. Click “Get Device Data” to upload the device data to the computer.INKBIRD IAQM 128W Air Quality Detector - 10
  4. Click “Browse” to choose a save path.INKBIRD IAQM 128W Air Quality Detector - 11
  5. Tick the checkboxes to choose the data to export.INKBIRD IAQM 128W Air Quality Detector - 12
  6. Click ‘Save’ to export the file.INKBIRD IAQM 128W Air Quality Detector - 13

FCC Requirement

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equip-ment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communica-tions. However, there is no guarantee that interference will not occur in a particular installa-tion. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

INKBIRD TECH.C.L.
support@inkbird.com
Factory address: 6th Floor, Building 713, Pengji Liantang Industrial Area, NO.2 Pengxing Road, Luohu Disctrict, Shenzhen, China
Office address: Room 1803, Guowei Building, NO.68 Guowei Road, Xianhu Community, LiaMang, Luohu District Shenzhen, China
INKBIRD IAQM 128W Air Quality Detector - icon13

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals