Philio PAN07 TWO SPDT Switch Module Owner’s Manual
- September 28, 2024
- Philio
Table of Contents
- Philio PAN07 TWO SPDT Switch Module
- Product Usage Instructions
- PAN07 TWO SPDT Switch module with meter
- Introduction
- Safety Precautions and Installation
- Specification
- Troubleshooting
- Installation
- Adding to Z-WaveTM Network
- Z-Wave’s Configuration
- Protection Command Classes
- Firmware update over the air (OTA)
- command Classes
- Disposal
- FCC Interference Statement
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Philio PAN07 TWO SPDT Switch Module
Specifications
- Rated Voltage: 100-240VAC
- Maximum Load Range: 5A
- Operating Temperature: Minimum 40m indoor, 100m outdoor line of sight
- Humidity: N/A
- Storage Temperature: N/A
- Frequency Range:
- 868.40MHz; 869.85MHz (EU)
- 908.40MHz; 916.00MHz (USA/Canada)
- 920.9MHz, 921.7MHz, 923.1MHz (TW/KR/Thai/SG)
- RF Power: +5dBm
- FCC ID: RHHPAN07
- Dimensions: 47.5 x 39 x16 mm
Product Usage Instructions
Safety Precautions and Installation
Avoid installing the unit in stormy or rainy weather. Ensure to isolate or
switch off the power source before installing or maintenance. Make sure the
power supply circuit is protected by a 16A circuit breaker or suitable
equivalent fuse.
Applications
The module can be used for various applications including light control. The
smart relay calibration technology reduces inrush current and works well with
incandescent, fluorescent, and LED lights.
Product Features
The switch module can detect instant power wattage and overload current (6A
with resistive load) of connected lights or appliances.
FAQ
Troubleshooting FAQ
Cause of Failure: The Switch not working and LED off Symptom : The Switch
is not connected to the main power or the switch may be broken.
Recommendation
- Check power connections.
- Do not open up the switch; send it for repair if needed.
PAN07 TWO SPDT Switch module with meter
Introduction
This in-wall dual relay switch module is a transceiver which is a Z-Wave
PlusTM enabled device and is fully compatible with any Z-WaveTM enabled
network. Mini size design let the module can easily hide itself into the wall
box and that will be good for the house decoration.
There are many kind of application by using the module to switch AC power On
and Off, one main application is the light control. The new smart relay
calibration technology can reduce the inrush current caused by the load and
let the module work perfectly with many kind of light like incandescent,
fluorescent and LED light.
This in-wall switch module is able to detect Instant power wattage and
overload current (6A with resistive load) of connected light or appliances.
When detecting overload state, the Module will be disabled and its On/Off
button will be lockout of which LED will flash quickly. However, disconnect
and re-connecting the Module will reset its overload condition to normal
status.
Safety Precautions and Installation
- Avoid installing the unit in storming or raining weather.
- Be sure to isolate or switch off power source before installing or maintenance.
- Do ensure that the power supply circuit protected by a 16A circuit breaker or suitable equivalent fuse.
IMPORTANT
- Installation must be performed by skilled technicians who are informed about the standards and technical requirements of the appliance and its proper installation.
- Check your local codes as they apply to your situation. If the house wiring is of aluminum, consult with an electrician about proper wiring methods.
- Before proceeding with the installation, TURN OFF THE POWER TO THE LIGHTING CIRCUIT AT THE CIRCUIT BREAKER OR FUSE BOX TO AVOID ELECTRICAL SHOCK.
Specification
Rated Voltage | 100-240VAC 50Hz/60Hz 5A |
---|---|
Maximum Load | 5A (230Vac/120Vac) (Resistive load) |
Range | Minimum 40m indoor 100m outdoor line of sight |
Operating Temperature | 0°C to 40°C |
Humidity | Up to 85% max. |
Storage Temperature | -20°C to 60°C |
Frequency Range | 868.40MHz; 869.85MHz (EU) |
908.40MHz; 916.00MHz (USA/Canada)
920.9MHz, 921.7MHz, 923.1MHz (TW/KR/Thai/SG)
RF Power| +5dBm
OTA| support
---|---
FCC ID| RHHPAN07
Dimensions| 47.5 x 39 x16 mm
Wire| 0.75mm², 18AWG
** Specifications are subject to change and improvement without notice.
Troubleshooting
Symptom | Cause of Failure | Recommendation |
---|---|---|
The Switch not working and LED off |
- The Switch is notconnect to the Main power
- The Switch break down
|
- Check power connections
- Don’t open up the Switch and send it for repair.
The Switch LED illuminating, but cannot control the ON/OFF
Switch of the attached load
| Check if the load connect into the Switch has its own ON/OFF switch| Set the
ON/OFF switch of the attached load to ON
The Switch LED illuminating, but the detector cannot controlthe Switch|
- Not carry out association
- Same frequency interference
|
- Carry out association
- Wait for a while to re-try
LED keep flashing, but cannot control| Overload occurs| Remove the attached load or check max. load cannot exceed6A(Resistive load)
Installation
For Instruction to http://www.philio-tech.com
DANGER
Danger of electrocution!
All works on the device may be performed only by a qualified and licensed
electrician. Observe national regulations.
Any works introducing changes into the configuration must be always performed
with disconnected voltage.
Choosing a Suitable Location
- Do not locate the Module facing direct sunlight, humid or dusty place.
- The suitable ambient temperature for the Module is 0°C~40°C.
- Do not locate the Module where exists combustible substances or any source of heat, e.g. fires, radiators, boiler etc.
- After putting it into use, the body of Module will become a little bit hot of which phenomenon is normal.
Adding to Z-WaveTM Network
In the side of casing, there is an on/off button with LED indicator below which is used to toggle switch on and off or carry out inclusion, exclusion, reset or association. When first power is applied, its LED flashes on and off alternately and repeatedly at 0.5 second intervals. It implies that it has not been assigned a node ID and start auto inclusion.
Auto Inclusion
The function of auto inclusion will be executed as long as the in wall switch
does not have Node ID and just connect the switch to main power.
Note: Auto inclusion timeout is 2 minute during which the node information of
explorer frame will be emitted once every several seconds. Unlike “inclusion”
function as shown in the table below, the execution of auto inclusion is free
from pressing the On/Off button on the Switch.
The table below lists an operation summary of basic Z-Wave functions. Please
refer to the instructions for your Z-WaveTM Certificated Primary Controller to
access the Setup function, and to include/exclude/reset/associate devices
Function | Description | Annotation |
---|---|---|
No node ID | The Z-Wave Controller does not allocate a node ID to the Switch. |
LED 2-second on, 2-second off
Add (Inclusion)| 1. Put your Z-Wave controller into inclusion mode by
following the instructions provided by the
controller manufacturer.
| one press one flash LED
x To support handling of the device when already installed the external switch can be used for inclusion or exclusion for 3 minutes after power up.
2. Pressing INCLUDE_BUTTON three times within 2 seconds will enter inclusion
mode.
Remove (Exclusion)| 1. Put your Z-Wave controller into exclusion mode by
following the instructions provided by the
controller manufacturer.
| one press one flash LED
x To support handling of the device when already installed the external switch can be used for inclusion or exclusion for 3 minutes after power up.
2. Pressing INCLUDE_BUTTON three times within 2 seconds will enter exclusion
mode.
3. Node ID has been excluded.| LED 0.5s On, 0.5s Off
(Enter auto inclusion)
Reset| 1. **** Pressing INCLUDE_BUTTON three times within 2 seconds will enter
inclusion mode.
| Use this procedure only in the event that the primary controller is lost or
otherwise inoperable.
---|---|---
2. ** Within 1 second, press On/Off button again for 5 seconds.
3. ** IDs are excluded.| LED 0.5s On, 0.5s Off
(Enter auto inclusion)
Association| 1. The PAN07 is an always listening Z-Wave device, so associations
be added or removed by a controller at any time.
Or If your controller requires to have the PAN07 send a ‘node information frame’ or NIF for associations, pressing the On/Off button three times within 2 seconds will cause
the PAN07 to send its NIF.
| one press one flash LED
2. There are 3 groups for the switch|
- Adding a node ID allocated by Z-Wave Controller means inclusion. Removing a node ID allocated by Z-Wave Controller means exclusion.
- Failed or success in including/excluding the node ID can be viewed from the Z-Wave Controller.
- Sometimes people are not easy to execute exclusion or inclusion especially when PAN07 already installed in a wall box. To solve this issue, PAN07 support a special feature that can use S1 or S2 to execute exclusion, inclusion, Reset or Association” at the first 3 minutes when first time connect to main power.
LED Indication
To distinguish what mode the switch is in, view from the LED for
identification.
State Type | LED Indication |
---|---|
Normal | Whatever we switch On and off of the PAN07 by S1 S2 or On/Off button |
or RF command, the LED will lights up 1 second and then off.
No node ID| Under normal operation, when the Switch has not been allocated a
node ID, the LED flashes on and off alternately at 2-second intervals. By
pressing S1 S2 or On/Off button, it will stop flashing temporarily.
Learning| When PAN07 is in learning mode, LED flashes on and off alternately
and repeatedly at 0.5 second intervals.
Overload| When overload state occurs, the Switch is disabled of which LED
flashes on and off alternately at 0.2 second intervals.
| Overload state can be cleared by disconnect and reconnect theSwitch to the
main power
---|---
Installation
- Put in wall switch into a wall box and connect the AC power wire L, N to PAN07 connector L, N.
- Connect the wall switch to the PAN07 as Fig1.
- To manually turn ON the Switch, press and release the On/Off button. The LED will light ON for 1 second, and the load plugged into the Switch will also turn ON.
- To manually turn OFF the Switch, simply press and release the On/Off button. The LED will light ON for 1 second and the load plugged into the Switch will turn OFF.
Programming
-
Basic Command Class / Binary Switch Command Class
The Switch will respond to BASIC and BINARY SWITCH commands that are part of the Z-Wave system.- 1- 1 BASIC_GET / BINARY_SWITCH_GET
- Since the switch have two relay, the Switch will report its On/Off state to the Controller by setting Configuration parameter 3.
- Configuration parameter 3=1(default)
- Report ON when either relay 1 ON or relay 2 ON
- Report OFF when both relay 1 and relay 2 OFF
- Configuration parameter 3=2 Report ON when relay 1 ON
- Report OFF when relay 1 OFF
- Configuration parameter 3=3 Report ON when relay 2 ON
- Report OFF when relay 2 OFF
- Basic Get Command: [Command Class Basic, Basic Get]
Basic Report Command
- Report OFF: [Command Class Basic, Basic Report, Value = 0(0x00)]
- Report ON:[Command Class Basic, Basic Report, Value = 255(0xFF)]
- Binary Switch Get Command:[Command Class Switch Binary, Switch Binary Get]
Binary Switch Report Command
- Report OFF:[Command Class Switch Binary, Switch Binary Report, Value =0(0x00)]
- Report ON:[Command Class Switch Binary, Switch Binary Report, Value = 255(0xFF)]
- Note: If the BASIC_GET/BINARY_SWITCH_GET command follow the
- switch On/Off command, it should add 0.5s time delay before the Get command.
1-2 BASIC_SET / SWITCH_BINARY_SET
- Since the switch has two relay, the load attached to the Switch will turn on or off upon receipt of the following commands from a Z-Wave Controller by setting Configuration parameter 3.
- Configuration parameter 3=1(default) switch ON and OFF both relay 1 and relay 2
- Configuration parameter 3=2 switch ON and OFF of relay 1
- Configuration parameter 3=3 switch ON and OFF of relay 2
[Command Class Basic, Basic Set, Value = 1~99, 255(0xFF)] : the load attached to the Switch turns on.
[Command Class Basic, Basic Set, Value = 0(0x00)] : the load attached to
the Switch turns off.
[Command Class Switch Binary, Switch Binary Set, Value = 1~99, 255(0xFF)]
: the load attached to the Switch turns on.
[Command Class Switch Binary, Switch Binary Set, Value = 0(0x00)] : the|
load attached to the Switch turns off.
- Z-Wave’s Groups (Association Command Class Version 2)
- The Switch can be set to send reports to control associated Z-Wave devices. It supports 3 association groups which every group has one node support. Group1~Group3 support SWITCH_BINARY_REPORT,
- METER_REPORT_COMMAND_V3
- For group 1, the Switch will report (1) ON/OFF status of Relay1 and Relay2 (2) Instant Power Consumption (Watt) of Relay1 and Relay2 (3) Accumulated Power Consumption (KWh) of Relay1 and Relay2 to group1 node.
- For group 2, the Switch will report (1) ON/OFF status of Relay1 (2) Instant Power Consumption (Watt) of Relay1 (3) Accumulated Power Consumption (KWh) of Relay1 to group2 node.
- For group 3, the Switch will report (1) ON/OFF status of Relay2 (2) Instant Power Consumption (Watt) of Relay2 (3) Accumulated Power Consumption (KWh) of Relay2 to group3 node.
- 1 Auto report to Grouping 1 ~3(Maximum Node 1)
On/Off Event Report
When “on” or “off” state has been changed, it will send Binary Switch Report
to the nodes of Group1~3.
Binary Switch Report
ON:[Command Class Switch Binary, Switch Binary Report, Value =255(0xFF)]
OFF:[Command Class Switch Binary, Switch Binary Report, Value =0(0x00)]
Instant Power Consumption vary over 5% report
When the power consumption of load vary over 5%, it will send Meter report to
the nodes of Group
Meter Report Command
[Command Class Meter,Meter Report,Rate Type = 0x01,Meter Type = 0x01,Precision
= 1,Scale = 0x02,Size = 4,Meter Value(W) ]
Overload alarm report command
When PAN07 detect the overload, it will send Alarm Report to the correspond
Group。
The content of Alarm Report
Alarm report command: [Command_Class_Alarm, Alarm_Report, Alarm Type = 0x08,
Alarm Level = 0xFF]
Response to Meter Get Command
The Switch will report its (1) instant Power Consumption (Watt) or (2)
accumulated power consumption(KWH) or (3) AC load Voltage (V) or (4) AC load
current ( I ) (5) load power factor (PF) to Z-Wave Controller after receive
the Meter Get Command from Z-Wave Controller.
Instant Power Consumption (Watt) of Switch
When receiving Meter Get Command, it will report Meter Report Command to the
node asked.
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x02(W)]
Meter Report Command:
[Command Class Meter,Meter Report,Rate Type = 0x01,Meter Type =
0x01,Precision = 1,Scale = 0x02,Size = 4,Meter Value(W) ]
Example:
- Meter Value 1 = 0x00 (W)
- Meter Value 2 = 0x00 (W)
- Meter Value 3 = 0x03 (W)
- Meter Value 4 = 0xEA (W)
- Meter(W) = Meter Value 3 *256 + Meter Value 4 = 100.2W
Accumulated Power Consumption (KW/h)
When receiving Meter Get Command, it will report Meter Report
- Command to the node asked.
Meter Get Command:
- [Command Class Meter, Meter Get, Scale = 0x00 KW/h)]
Meter Report Command:
- [Command Class Meter,Meter Report,Rate Type = 0x01, Meter Type
- =0x01, Precision = 2,Scale = 0x00,Size = 4,Meter Value (KWh)]
Example:
- Scale = 0x00 (KWh)
- Precision = 2
- Size = 4 Bytes (KWh)
- Meter Value 1 = 0x00(KWh)
- Meter Value 2 = 0x01(KWh)
- Meter Value 3 = 0x38(KWh)
- Meter Value 4 = 0xA3(KWh)
- Accumulated power consumption (KWh) = (Meter Value 2*65536) + (Meter
- Value 3*256) + (Meter Value 4) = 800.35 (KWh)
Clearing accumulated power consumption
- Whenever re-start counting the accumulated power consumption is needed, you can use Meter Reset Command to clear it.
- Meter Reset Command: [Command Class Meter, Meter Reset]
AC load Voltage (V)
When receiving Meter Get Command, it will report Meter Report Command to the
node asked.
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x04(V)]
Meter Report Command:
[Command Class Meter,Meter Report,Rate Type = 0x01,Meter Type = 0x01,Precision
= 1,Scale = 0x04,Size = 2, Meter Value(V)]
Example:
Scale = 0x04 (V)
- Precision = 1
- Size = 2 (2 Bytes of V)
- Meter Value 1 = 0x09(V)
- Meter Value 2 = 0x01(V)
- AC load Voltage = (Meter Value 1*256) +(Meter Value 2)= 230.5 (V)
AC load current ( I )
- When receiving Meter Get Command, it will report Meter Report Command to the node asked.
- Meter Get Command: [Command Class Meter, Meter Get, Scale =0x05(I)]
Meter Report Command
- [Command Class Meter,Meter Report,Rate Type = 0x01,Meter Type =
- 0x01,Precision = 2,Scale = 0x05,Size = 2,Meter Value(I)]
Example
- Scale = 0x05 (I)
- Precision = 2
- Size = 2 (2 Bytes of I)
- Meter Value 1 = 0x01(I)
- Meter Value 2 = 0x21(I)
- AC load current = (Meter Value 1*256) +(Meter Value 2)= 2.89 (A)
- 2-2-6 load power factor (PF)
- When receiving Meter Get Command, it will report Meter Report Command to
- the node asked.
- Meter Get Command: [Command Class Meter, Meter Get, Scale =0x06(PF)]
Meter Report Command
- [Command Class Meter,Meter Report,Rate Type = 0x01,Meter Type = 0x01, Precision = 2,Scale = 0x06,Size = 1 Bytes,Meter Value(PF)]
Example
- Scale = 0x06 (PF)
- Precision = 2
- Size = 1 (1 Byte of PF)
- Meter Value 1 = 0x63(PF) (It means that the load power factor is 0.99)
Multi Channel Command Class Version 3
PAN07 also support Muti Channel command class (version 3), which include
BINARY_SWITCH_GET, BINARY_SWITCH_SET, BASIC_GET, BASIC_SET,
METER_SUPPORTED_GET, METER_RESET, METER_GET.
You may control or get report from 3 endpoints of PAN07.
BINARY_SWITCH_GET
- You may get the ON/OFF state from every endpoint, when endpoint set to 1,
- PAN07 will reply state of Relay1.
- If endpoint set to 2 and PAN07 will reply state of Relay2.
- If endpoint set to 3 and PAN07 will reply ON(0xFF) either Relay 1 or Relay2 is ON, report OFF(0x00) when both Relay 1 and Relay2 OFF.
- Below is an example show a source endpoint 5 send a get command to PAN07 endpoint 1
COMMAND_CLASS_MULTI_CHANNEL| this is the endpoint of command inquirer here we assume endpoint is 5,if the inquirer doesn’t support
multi Channel this value will be 0)
(Bit Address =0;Destination End Point range from 1~3)
---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x05
(Bit Address+Destination End Point = 0x01)
Command Class = 0x25| (Command_Class_Switch_Binary = 0x25)
(Switch_Binary_Get = 0x02)
---|---
Command =0x02
Below is the example show PAN07 report to last command
COMMAND_CLASS_MULTI_CHANNEL| Since the endpoint is 1 so PAN07 will reply ON(0xFF) when Relay is ON, report OFF (0x00) when Relay 1 is OFF
- (Bit Address =0;Destination End Point)
- (Command_Class_Switch_Binary = 0x25)
- (Switch_Binary_Reportet = 0x3)
- (ON=0xFF , OFF=0x00)
---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x01
(Bit Address+Destination End Point = 0x05)
Command Class = 0x25
Command =0x03
Parameter 1 = 0xFF
Note: If the Multi-Channel Encapsulated BASIC_GET/SWITCH_GET command follow a switch On/Off command, it should add 0.5s time delay before the Get command.
BINARY_SWITCH_SET
By using BINARY_SWITCH_SET Command of Multi Channel Command Class
Encapsulation Command, you can switch Relay1 ON/OFF by setting endpoint to 1
or switch Relay2 ON/OFF by setting endpoint to 2 or switch both Relay1 and
Relay2 ON/OFF by setting endpoint to 3.
The example of the command show that switch off relay1 of PAN07
COMMAND_CLASS_MULTI_CHANNEL| (this is the endpoint of command inquirer here we assume endpoint is 1,if the inquirer doesn’t support multi
Channel this value will be 0)
(Bit Address =0;Destination End Point range1~3)
Command_Class_Switch_Binary = 0x25)
(Switch_Binary_Set = 0x01)
---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x01
(Bit Address+Destination End Point = 0x02)
Command Class = 0x25
Commazd =0x01
Parameter 1 = 0x00| (ON=0xFF , OFF=0x00)
METER_SUPPORTED_GET:
This command is to ask the endpoint of PAN07 what kind of meter data can be
reported
The example show how to get the meter report type
COMMAND_CLASS_MULTI_CHANNEL
|
---|---
MULTI_CHANNEL_CMD_ENCAP| (this is the endpoint of command inquirer here we
assume endpoint is 1, if the inquirer doesn’t support multi
Channel this value will be 0)
(Bit Address =0;Destination End Point range1~3)
( Command_Class_Meter_V3 = 0x32) (Meter_Supported_Get = 0x03)
---|---
Source End Point = 0x01
(Bit Address+Destination End Point = 0x03)
Command Class = 0x32
Command =0x03
Below is the example show PAN07 report to last command
COMMAND_CLASS_MULTI_CHANNEL
| (Command_Class_Meter_V3 = 0x32) (Meter_Supported_Report = 0x04) (Meter Reset =1 , Meter Type=0x01)
(Scale Supported =
KWh+W+V+A+Power Factor = 0x75)
---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x03
(Bit Address+Destination End Point = 0x01)
Command Class = 0x32
Command =0x04
Parameter 1 = 0x81
Parameter 2 = 0x75
METER_RESET
This command is to reset the Accumulated Power Consumption (KWh) to 0
The example show how to reset the KWh
COMMAND_CLASS_MULTI_CHANNEL| (this is the endpoint of command inquirer, here we assume endpoint is 3,if the inquirer doesn’t support multi Channel
this value will be 0)
(Bit Address =0;Destination End Point range1~3)
( Command_Class_Meter_V3 = 0x32) ( Meter_Reset = 0x05)
---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x03
(Bit Address+Destination End Point = 0x01)
Command Class = 0x32
Command =0x05
METER_GET
Using meter get command to get the KWH, W, V, I, PF from endpoint of PAN07
Get KWH from endpoint
Meter_GET example:
COMMAND_CLASS_MULTI_CHANNEL| (this is the endpoint of command inquirer, here
we assume endpoint is 5,if the
---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x05
| inquirer doesn’t support multi Channel
---|---
this value will be 0)
(Bit Address+Destination End Point =
| (Bit Address =0;Destination End Point
0x03)| range1~3)
Command Class = 0x32| ( Command_Class_Meter_V3 = 0x32)
Command =0x01| (Meter_Get = 0x01)
Parameter 1 = 0x00| (Scale = KWH = 0x00)
Accumulated power consumption (KWH) Report example:
COMMAND_CLASS_MULTI_CHANNEL| (Meter report = Endpoint3)
(Bit Address =0;Destination End Point = command inquirer’s Endpoint value)
(Command_Class_Meter_V3 = 0x32) (Meter_Report = 0x02)
(Scale Bit2 = 0 ,Rate Type = 0x01,
Meter Type=0x01)
(Precision = 2,Scale Bit1Bit0 = 0,Size= 4)
---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x03
(Bit Address+Destination End Point = 0x05)
Command Class = 0x32
Command =0x02
Parameter 1 = 0x21
Parameter 2 = 0x44
Parameter 3 = 0x00| Accumulated Power Consumption = 0x000005FD = 15.33 KWh
---|---
Parameter 4 = 0x00
Parameter 5 = 0x05
Parameter 6 = 0xFD
Get Instant Power Consumption (Watt) from endpoint
METER_GET example
COMMAND_CLASS_MULTI_CHANNEL
|
(this is the endpoint of command inquirer, here we assume endpoint is 5,if the inquirer doesn’t support multi Channel this
value will be 0)
(Bit Address =0;Destination End Point range 1~3)
( Command_Class_Meter_V3 = 0x32) (Meter_Get = 0x01)
(Scale = W = 0x02)
---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x05
(Bit Address+Destination End Point = 0x03)
Command Class = 0x32
Command =0x01
Parameter 1 = 0x10
c| (Meter report = Endpoint3)
(Bit Address =0;Destination End Point = command inquirer’s Endpoint value)
(Command_Class_Meter_V3 = 0x32) (Meter_Report = 0x02)
(Scale Bit2 = 0 ,Rate Type = 0x01,
Meter Type=0x01)
(Precision = 1,Scale Bit1Bit0 = 0x02,Size= 4)
Instant Power Consumption = 0x000003EA00.2W
---|---
Source End Point = 0x03
(Bit Address+Destination End Point = 0x05)
Command Class = 0x32
Command =0x02
Parameter 1 = 0x21
Parameter 2 = 0x34
Parameter 3 = 0x00
Parameter 4 = 0x00
Parameter 5 = 0x03
Parameter 6 = 0xEA
Get load voltage V from endpoint
Meter_GET example:
COMMAND_CLASS_MULTI_CHANNEL| (this is the endpoint of command inquirer, here
we assume endpoint is 5,if the
---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x05
| inquirer doesn’t support multi Channel this
---|---
value will be 0)
(Bit Address+Destination End Point =| (Bit Address =0;Destination End Point
0x03)| range1~3)
Command Class = 0x32| ( Command_Class_Meter_V3 = 0x32)
Command =0x01| (Meter_Get = 0x01)
Parameter 1 = 0x20| (Scale = V = 0x04)
COMMAND_CLASS_MULTI_CHANNEL| (this is the endpoint of command inquirer, here
we assume endpoint is 5,if the inquirer does not support multi
Channel this value will be 0)
(Bit Address =0;Destination End Point range1~3)
---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x05
(Bit Address+Destination End Point = 0x03)
Command Class = 0x32| ( Command_Class_Meter_V3 = 0x32) (Meter_Get = 0x01)
(Scale = PF = 0x06)
---|---
Command =0x01
Parameter 1 = 0x30
PAN07 power factor report example
COMMAND_CLASS_MULTI_CHANNEL
|
- (Meter report = Endpoint3)
- (Bit Address =0;Destination End Point = command inquirer’s Endpoint value)
- (Command_Class_Meter_V3 = 0x32) (Meter_Report = 0x02)
- (Scale Bit2 = 1 ,Rate Type = 0x01,
- Meter Type=0x01)
- (Precision = 2,Scale Bit1Bit0 = 0x10, Size = 1)
- Power Factor = 0x63 = 0.99
---|---
MULTI_CHANNEL_CMD_ENCAP
Source End Point = 0x03
(Bit Address+Destination End Point = 0x05)
Command Class = 0x32
Command =0x02
Parameter 1 = 0xA1
Parameter 2 = 0x51
Parameter 3 = 0x63
Z-Wave’s Configuration
Configurat
ion Parameter
| Function| Size (Byte
)
| Value| Unit| Default| Description
---|---|---|---|---|---|---
1| Watt Meter Report Period| 2| 0x00-
0x7FFF
| 5s| 720| 0:Disable Report W 1~0x7FFF:
720*5s=3600s=
1 hour
---|---|---|---|---|---|---
2| KWH
Meter Report Period
| 2| 0x00-
0x7FFF
| 10min| 6| 0:Disable Report KWH 1~0x7FFF:
6*10min= 1 hour
3| Slected Relay| 1| 1-3| | 3| 1:Relay1
2:Relay2 3:Relay1 &
Relay2
4| Edge or Pulse mode or Edge-Toggl e mode| 1| 1-3| | 1| 1:Edge mode 2:Pulse mode
3:Edge-Toggle mode
5| Threshold
of current
for Load Caution
| 2| 10-600| 0.01A| 600| 600*0.01A =
6.0A
6| Threshold of KWH for Load Caution| 2| 1-10000| 1KWh| 10000|
7| Relay control mode| 1| 1-2| | 1| 1 : Control relay refer to meter wattage
2 : Control relay directly
8| Restore Relay state mode| 1| 0-2| | 1| 0 : All relay stay NC terminal
1 : Last relay switch state
2 : All relay stay NO terminal
9| Existence of Endpoint3| 1| 1-2| | 1| 1 : Endpoint3 exist
2 : No Endpoint3
14| Watt differential report
mode
| 1| 0-4| | 1| 0 : Disable
1 : 5%
2 : 10%
3 : 15%
| | | | | | 4 : 20%
---|---|---|---|---|---|---
31| Select Auto Report
Type
| 1| 1-2| | 1| 1 : Basic type
2 : MultiChannel type
-
Watt Meter Report Period:
If the setting is configured for 1hour (set value =720), the PAN07 will report its instant power consumption every 1 hour to the node of correspond Group.
The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr). -
KWH Meter Report Period:
If the setting is configured for 1hour (set value =6), the PAN07 will report its Accumulated Power Consumption (KWh) every 1 hour to the node of correspond Group. The maximum interval to report its Accumulated Power Consumption (KWh) is 227.55 days (10min*32767/1440=227.55 days). -
Selected Relay
If Controller not using Multi_Channel command class to access the relay of PAN07, you may configure the value of relay to react the Basic Command Class 、Binary Switch Command Class or Meter Command Class V3
Selecte Relay1 and Relay2: Default select is 3
Set command| Relay state|
---|---|---
Basic_Set or Binary_Switch_Set ON| Relay1 ON &
Relay2 ON
|
Basic_Set or Binary_Switch_Set OFF| Relay1 OFF &
Relay2 OFF
|
Get command| Relay state| Report to command sender
---|---|---
Basic_Get or Binary_Switch_Get| Relay1 ON or
Relay2 ON
| ON
Basic_Get or Binary_Switch_Get| Relay1 OFF &
Relay2 OFF
| OFF
Get command| parameter| Report to command inquirer
---|---|---
Meter_Get| KWh| Relay1 KWh1+Relay2 KWh2
Meter_Get| ****
Watt
| Relay1 W1+Relay2 W2
Meter_Get| ****
Voltage
| Relay1 and Relay2 are the same voltage
Meter_Get| ****
Current
| Relay1 I1+Relay2 I2
Meter_Get| Power factor PF| Only Relay1
-
Selecte Relay 1
Only relay1 can be controlled and report. -
Selecte Relay 2
Only relay2 can be controlled and report. -
Edge and Pulse mode
Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge-Toggle mode, default value is Edge mode.
Edge mode: this mode is suitable for the bi-stable wall switch that has
indicator point on the switch, and the same position correspond to same state
of relay1 and relay2. if the PAN07 relay change the state because of receiving
Z-Wave RF command, it may need two times of change
(switch on to off or switch off to on) to let relay back to the correspond
state.
Pulse mode: this mode is suitable for the toggle type wall switch to swap the state of Relay1 or Relay2
Edge-Toggle mode: this mode is suitable for the normal bi-stable switch, every time when change the state of the wall switch will also swap the state of Relay1 or Relay2.
Threshold of current for Load Caution
This is a warning when the current of load over the preset threshold value, if the setting value is 600 (6A), when the load current of Relay1 over this value, PAN07 will send current meter report to the node of correspond Group, the Range of the setting value is from 10 to 600, and the default value is 600 (6A).
Threshold of KWh for Load Caution
This is a warning when the KWh of load over the preset threshold value, If the
setting value is 10000, when the Accumulated Power Consumption of Relay1 or
Relay2 over this value, PAN07 will send KWh Meter Report command to the node
of correspond Group, minimum value is 1KWh and default value is 10000 kWh.
Relay control mode
- Relay controlling is referred to the meter wattage: When PAN07 gets an instruction from RF command or the manual switch, to switch on or off, it will check the wattage of the load first. If the wattage value is greater than 2 watts, the switch state means ON; on the other hand, it means OFF. When the switch state is ON, only SWITCH OFF instruction will be accept; on the other hand, when the switch state is OFF, only SWITCH ON instruction will be accept.
- Control relay directly: Whenever PAN07 get an SWITCH ON instruction, itwill close the relay; on the other hand, it will open the relay.
- Restore switch state mode
Whenever the AC power return from lost, PAN07 will restore the relay switch state which could be All relay stay NC terminal、Last relay switch state、All relay stay NO terminal. The default setting is Last relay switch state.
Existence of Endpoint3
The endpoint3 of Multi-Channel Command Class is related to relay1 and relay2.
It may be redundant for the need to control relay1 or relay2 individually.
When the Existence of Endpoint3 is set as 0, the endpoint3 of Multi-Channel
Command Class will be disabled. The default value is 1.
Watt differential report mode :
Disable : The function of Watt differential report will be disabled.
- 3-10-1 Disable : The function of Watt differential report will be disabled.
- 3-10-2 5% : When the differential value of Watt is over 5%, PAN07 will send a meter report to the associated group.
- 3-10-3 10% : When the differential value of Watt is over 10%, PAN07 will send a meter report to the associated group.
- 3-10-4 15% : When the differential value of Watt is over 15%, PAN07 will send a meter report to the associated group.
- 3-10-5 20% : When the differential value of Watt is over 20%, PAN07 will send a meter report to the associated group.
Select Auto Report type
- Basic type : PAN07 will send Switch_Binary_Report and Meter_Report to the associated group node.
- Multi Channel type : PAN07 will send Switch_Binary_Report and Meter_Report which are encapsulated by the Multi_Channel_Cmd_Encap to theassociated group node.
Protection Command Classes
PAN07 supports Protection Command Class version 2, it can protect the switch
against unintentionally control by e.g. a child. And it can also protect the
switch from being turned off by setting it in “No RF Control” state.
After being set to “Protection by sequence” state, any intentional pressing of
On/Off button or S2/S2 should be hold longer than 1 second, or the switch
state will not change. However, the operation of learn function does not
change, because learning will not be protected.
Firmware update over the air (OTA)
PAN07 is based on 500 series SoC and supports Firmware Update Command Class, it can receives the updated firmware image sent by controller via the Z-wave RF media. It is a helpful and convenient way to improve some function if needed.
command Classes
The Switch supports Command Classes including…
- COMMAND_CLASS_ZWAVEPLUS_INFO
- COMMAND_CLASS_VERSION_V2
- COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
- COMMAND_CLASS_DEVICE_RESET_LOCALLY
- COMMAND_CLASS_ASSOCIATION_V2
- COMMAND_CLASS_ASSOCIATION_GRP_INFO
- COMMAND_CLASS_POWERLEVEL
- COMMAND_CLASS_SWITCH_BINARY
- COMMAND_CLASS_BASIC
- COMMAND_CLASS_SWITCH_ALL
- COMMAND_CLASS_ALARM
- COMMAND_CLASS_SCENE_ACTIVATION
- COMMAND_CLASS_SCENE_ACTUATOR_CONF
- COMMAND_CLASS_PROTECTION
- COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
- COMMAND_CLASS_MULTI_CHANNEL_V3
- COMMAND_CLASS_METER_V3
- COMMAND_CLASS_CONFIGURATION
Warning:
- Plug out to disconnect from power supply; Do not plug in line.
- Do not exceed the max rating
Disposal
This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.
Philio Technology Corporation
8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist., New Taipei City
24257,Taiwan(R.O.C) www.philio-tech.com
FCC Interference Statement
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful
interference to
radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
FCC Caution:
Any changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate this equipment.
This transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>