MI 3102 BT EurotestXE is a multifunctional measuring instrument which performs a complete set of installation safety tests according to IEC/EN 61557. It supports AUTO SEQUENCE ® testing of the TN, TT and IT earthing systems. ISFL measurements and the IMD tests can be performed. Besides, the MI 3102 BT EurotestXE enables on-line voltage monitoring, phase sequence testing, earth resistance measurement, illuminance measurement and TRMS current measurement. EurotestXE is equipped with integrated characteristics of fuses and RCDs for PASS / FAIL evaluation of test results. All the results can be quickly saved and referenced on the instrument and then downloaded via the EuroLink PRO software (included in the standard set) to the computer for evaluation and report generation after testing.

Measuring functions:
  • Insulation resistance with DC voltage from 50 V to 1000 V;
  • Continuity of PE conductors with 200 mA DC test current with polarity change;
  • Continuity of PE conductors with 7 mA test current without RCD tripping;
  • Line/Loop impedance;
  • Loop impedance with Trip Lock RCD function;
  • TRMS voltage and frequency;
  • Phase sequence;
  • Power and harmonics;
  • RCD testing (general and selective, type AC, A, F, B, B+);
  • Earth resistance (3-wire and 2-clamps method);
  • Specific earth resistance with Ro-adapter (option);
  • TRMS leakage and load currents (option);
  • First fault leakage current (ISFL);
  • Testing of Insulation Monitoring Devices (IMDs);
  • Illumination (option).
Key features:
  • Predefined mini AUTOSEQUENCEs:
    Auto TT (U, Zln, Zs, Uc);
    Auto TN/RCD (U, Zln, Zs, Rpe);
    Auto TN (U, Zln, Zlpe, Rpe);
    Auto IT (U, Zln, Isc, Isfl, IMD).

  • Power measurements and harmonics analysis

  • Built-in help screens for referencing on site.

  • Built-in fuse tables for automatic evaluation of the line / loop impedance result.

  • Monitoring of all 3 voltages in real-time.

  • Automatic polarity reversal on continuity test.

  • Loop impedance test without tripping the RCD.

  • Built-in charger and rechargeable batteries as standard accessory.

  • Automated RCD testing procedure.

  • BT communication with PC, Android tablets and smart phones via built-in BT.

  • PC SW EuroLink PRO for downloading of test results and report creation.

  • EuroLink Android APP, data management tool (option).

APPLICATION
  • Initial and periodic testing of domestic and industrial installations.
  • Testing of single and multiphase systems.
  • Testing of TT, TN and IT earthing systems.
  • Medical installation testing.
STANDARDS
  • Functionality:
    EN 61557
    DIN 5032

  • Other reference standards for testing:
    IEC/EN 60364-4-41;
    EN 61008;
    EN 61009;
    BS 7671;
    AS/NZ 3017;
    CEI 64.8;
    HD 384;
    VDE 413

  • Electromagnetic compatibility (EMC):
    EN 61326

  • Safety (LVD):
    EN 61010-1;
    EN 61010-031
    EN 31010-2-030
    EN 31010-2-032

Technical specification
Function Measuring range Resolution Accuracy
CONTINUITY Test Current 7 mA 2-wire 0.00 Ω … 19.99 Ω 0.1 Ω

r. + 5 digits)
20.0 Ω … 1999 Ω| 1 Ω
Test Current 200 mA 2-wire| 0.00 Ω … 19.99 Ω| 0.01 Ω| ±(3 % of r. + 3 digits)
20.0 Ω … 199.9 Ω| 0.1 Ω| ±(5 % of r.)
200.0 Ω … 1999 Ω| 1 Ω| ±(5 % of r.)
INSULATION RESISTANCE| Test Voltage 50/100/250 V| 0.00 MΩ … 19.99 MΩ| 0.01 MΩ| ±(5 % of r. + 3 digits)
20.0 MΩ … 99.9 MΩ| | ±(10 % of r.)
100.0 MΩ … 199.9 MΩ| 0.1 MΩ| ±(20 % of r.)
Test Voltage 500/1000 V| 0.00 MΩ … 19.99 MΩ| 0.01 MΩ| ±(5 % of r. + 3 digits)
20.0 MΩ … 99.9 MΩ| 0.1 MΩ| ±(5 % of r.)
200 MΩ … 999 MΩ| 1 MΩ| ±(10 % of r.)
RCD| RCD Uc| 0.00 V … 19.99 V| 0.1 V| (-0%/±15 %) of r. ± 10 digits
20.0 V … 99.9 V| (-0%/±15 %) of r.
RCD (t),| 0.0 ms … 40.0 ms| 0.1 ms| ±1 ms
0.0 ms … max.time| ±3 ms
RCD I Ramp| 0.2xI∆N … 1.1xI∆N (AC)| 0.05xI∆N| ±0.1xI∆N
0.2xI∆N … 1.5xI∆N (A), I∆N ≥30 mA)
0.2xI∆N … 2.2xI∆N (A), I∆N <30 mA)
0.2xI∆N … 2.2xI∆N (B)
IMPEDANCE| Zline L-L, L-N Ipsc| 0.00 Ω … 9.99 Ω| 0.01 Ω| ±(5 % of r. + 5 digits)
10.0 Ω … 99.9 Ω| 0.1 Ω|
100 Ω … 999 Ω| 1 Ω|
1.00 kΩ … 9.99 kΩ| 10 Ω| ±(10 % of r.)”
Zloop L-PE, Ipfc| 0.00 Ω … 9.99 Ω| 0.01 Ω| ±(5 % of r. + 5 digits)
10.0 Ω … 99.9 Ω| 0.1 Ω|
100 Ω … 999 Ω| 1 Ω| ±(10 % of r.)
1.00 kΩ … 9.99 kΩ| 10 Ω|
VOLTAGE| TRMS| 0 … 550 V| 1 V| ±(2 % of r. + 2 digits)
Frequency| 0.00 Hz .. 9.99 Hz| 0.01 Hz| ±(0.2 % of r. + 1 digits)
10.0 Hz … 499.9 Hz| 0.1 Hz
CURRENT| TRMS, AC with A1018| 0.0 mA … 99.9 mA| 0.1 mA| ±(5 % of r. + 5 digits)
100 mA … 999 mA| 1 mA| ±(3 % of r. + 3 digits)
1.00 A … 19.99 A| 0.01 A| ±(3 % of r.)
TRMS, AC with A1019| 0.0 mA … 99.9 mA| 0.1 mA| idicative
100 mA … 999 mA| 1 mA| ±(5 % of r.)
1.00 A … 19.99 A| 0.01 A| ±(3 % of r.)
TRMS, AC/DC with A1391, range=40A| 0.00 A … 1.99 A| 0.01 A| ±(3 % of r. + 3 digits)
2.00 A … 19.99 A| 0.01 A| ±(3 % of r.)
20.0 A … 39.9 A| 0.1 A| ±(3 % of r.)
TRMS, AC/DC with A1391, range = 300A| 0.00 A … 19.99 A| 0.01 A| idicative
20.0 A … 39.9 A| 0.1 A| ±(3 % of r. + 5 digits)
40.0 A … 299.9 A| 0.1 A|
EARTH RESISTANCE| 3 wire| 0.00 Ω … 19.99 Ω| 0.01 Ω|
20.0 Ω … 199.9 Ω| 0.1 Ω| ±(5 % of r. + 5 digits)
200.0 Ω … 9999 Ω| 1 Ω|
2 clamp| 0.00 Ω … 19.99 Ω| 0.01 Ω| ±(10 % of r. + 10 digits)
20.0 Ω … 30.0 Ω| 0.1 Ω| ±(20 % of r.)
30.1 Ω … 99.9 Ω| 0.1 Ω| ±(30 % of r.)
Specific earth resistance| 0.0 Ωm … 99.9 Ωm| 0.1 Ωm| ±(5 % of r.) for Re 1 Ω … 1999kΩ
±(10 % of r.) for Re 2 kΩ … 19.99kΩ
±(20 % of r.) for Re > 20 kΩ
100 Ωm … 999 Ωm| 1 Ωm
1.00 Ωmk … 9.99 kΩm| 0.01 kΩm
10.0 Ωmk … 99.9 kΩm| 0.1 kΩm
FIRST FAULT LEAKAGE CURRENT| | 0.0 mA … 19.9 mA| 0.1 mA| ±(5 % of r. + 3 digits)
IMD TEST| Threshold in-dicative insulation resistance| 5 … 640 kΩ| 5 kΩ| Indicative values, up to 128 steps
ILLUMINANCE| Type B| 0.01 lux … 19.99 lux| 0.01 lux| ±(5 % of r. + 2 digits)
20.0 lux … 199.9 lux| 0.1 lux|
200 lux … 1999 lux| 1 lux| ±(5 % of r.)
2.00 klux … 19.99 klux| 10 lux|
Type C| 0.01 lux … 19.99 lux| 0.01 lux| ±(10 % of r. + 3 digits)
20.0 lux … 199.9 lux| 0.1 lux|
200 lux … 1999 lux| 1 lux| ±(10 % of r.)
2.00 klux … 19.99 klux| 10 lux|
GENERAL| Power supply| 9 VDC (6×1.5 V battery or accu, size AA)
Overvoltage category| 1000 V DC CAT II; 600 V CAT III; 300 V CAT IV
Protection class| double insulation
COM port| BT, USB, RS232
Weight| 1.3 kg
Size ( l x h x w )| 230 x 103 x 115 mm

Measuring and Regulation Equipment Manufacturer
METREL d.d.
Ljubljanska 77
SI-1354 Horjul
Tel: + 386 (0)1 75 58 200
Fax: + 386 (0)1 75 49 226
E-mail: metrel@metrel.si
http://www.metrel.si

Ordering information

Standard set                                         MI 3102 BT

  • Instrument EurotestXE
  • Plug commander, 1.5 m
  • Test lead, 3 x 1.5 m
  • Earth test set, 3-wire, 20 m (test lead, 4 m; 2 x test lead, 20 m; 2 x test rod)
  • Power supply adapter + 6 NiMH rechargeable batteries, size AA
  • PC Software EuroLink PRO
  • Test probe, 3 pcs (blue, black, green)
  • Crocodile clip, 3 pcs (blue, black, green)
  • RS232 – PS/2 cable
  • USB cable
  • Soft carrying neck belt
  • Soft carrying bag
  • Short instruction manual
  • Instruction manual on CD
  • Handbook on CD
  • Calibration certificate
Optional accessories

Photo

|

Order No.

| Description
---|---|---
|

A 1401

| Tip commander (3-wire)
|

A 1018

| Current clamp (low range, leakage)
|

A 1019

| Current clamp
|

A 1391

| AC/DC Current clamp
|

A 1110

| Three phase adapter
|

A 1111

| Three phase adapter with switch
|

A 1201

| Insulated rod for CONTINUITY measurement
|

A 1202

| Additional extension part for A 1201
|

A 1172

| Luxmeter sensor, type B (PS/2)

A 1173

| Luxmeter sensor, type C (PS/2)
|

A 1153

| Test lead, black, 20 m
|

A 1431

| EuroLink Android APP
|

A 1292

| Upgrade code EuroLink PRO to EuroLink PRO Plus
|

A 1160

| Fast charger for 8 AA batteries with a set of 6 NiMH bat., type AA
|

S 2027

| Earth test set, 3-wire, 50 m
|

A 1199

| Ro-adapter

Note! Photographs in this catalogue may slightly differ from the instruments at the time of delivery. Subject to technical change without notice.

BELGIË
——————————
Leuvensesteenweg 607
1930 Zaventem
T: 02 – 757 92 44
F: 02 – 757 92 64
sales@euro-index.be
www.euro-index.be

NEDERLAND
——————————
Rivium 2e straat 12
2909 LG Capelle a/d Ijssel
T: +31 – (0)10 – 2 888 000
F: +31 – (0)10 – 2 888 010
verkoop@euro-index.nl
www.euro-index.nl

Documents / Resources

| METREL MI 3102 BT EurotestXE Insulation Tester [pdf] Instruction Manual
MI 3102 BT, MI 3102 BT EurotestXE Insulation Tester, EurotestXE Insulation Tester, Insulation Tester, Tester
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals