offgridtec R-BOX-NEMA3 Battery Cabinet Floor Mounting Instruction Manual
- September 26, 2024
- Offgridtec
Table of Contents
offgridtec R-BOX-NEMA3 Battery Cabinet Floor Mounting
R-B0X-NEMA3 Installation Instructions
Floor Mounting
- Fix the Floor Mounting Base with expansion screws
- Untwist latches to remove the top cover of main cabinet
- Fix the main cabinet to Floor Mounting Base with M6 screws.
- Place the batteries into cabinet as shown in picture and fix them to cabinet with M6 Screws.
- Cabling.
- Place and lock the top cover to main cabinet by twisting the latches.
Wall Mounting
- Fix the Wall Mounting Base and Wall Mounting Plate to wall with expansion screws by Positioning Board.
- Untwist latches to remove the top cover of main cabinet.
- Fix the Wall Mounting Adapter to Cabinet with M4Screws
- Install the main cabinet to wall by aligning Wall Mounting Adapter to Wall Mounting Plate. Then to fix the main cabinet to Wall Mounting Base with M6 Screws.
- Place the batteries into cabinet as shown in picture and fix them to cabinet with M6 Screws.
- Cabling.
- Place and lock the top cover to main cabinet by twisting the latches.
Packing List
NO. | Items | Quantit | Specifications | Pictures |
---|---|---|---|---|
1 | **** |
Main Cabinet
| ****
1 pcs
| 20.9”x15.8″x28.9″
530×400.3×734.7mm|
2| Floor Mounting Base|
1 pcs
| ****
20.9″x11.9″x2.8″
530×301.2x70mm
|
3| Wall Mounting Base|
1 pcs
| 20.9″x16.1″x4. 7″
530x409Xx120mm|
4| Wall Mounting Plate|
1 pcs
| 10.6″x0.6″x2.1″
270x15x53mm|
5| Wall Mounting Adapter| ****
1 pcs
| 9.8″x0.8″x1.2″
250x20x30mm|
6
| Battery to Busbar Power Cable (Positive)| ****
1 pcs
| UL10269-4AWG-220mm-
Orange-Amphenol 5.7mm Positive+ SC25-6| ****
7
| Battery to Busbar Power Cable (Positive)| ****
1 pcs
| UL10269-4AWG-310mm-
Orange-Amphenol 5.7mm Positive+ SC25-6| ****
8
| Battery to Busbar Power Cable (Negative)| ****
1 pcs
| UL10269-4AWG-260mm-Black
-Amphenol 5.7mm Negative+ SC25-6| ****
9
| Battery to Busbar Power Cable (Negative)| ****
1 pcs
| UL10269-4AWG-330mm-Black
-Amphenol 5.7mm Negative+ SC25-6|
10| Battery to Cabi- net Earthing Cable|
1 pcs
| UL1015-10AWG-250mm
Yellow/Green-SC6-6+SC6-6| ****
11| Battery to Bat- tery Earthing Cable| ****
1 pcs
| UL1015-10AWG-120mm
Yellow/Green-SC6-6+SC6-6| ****
12| ****
M4Screw
| ****
3 pcs
| GB/T 70.3-2000 M4x0.3″ (8mm)|
13|
M6 Screw
| ****
10 pcs
| ISO 10644G-2014 M6x0.5″(12mm)|
14|
Expansion Screw
| ****
12 pcs
| GB/T 22795(TCQ)-2008 M8x2.0″(50mm)|
15|
Positioning Board
| ****
1 pcs
| 20.9″x28.7″x0.06″
530x730x1.5mm| ****
16
| Warning label| ****
1 pcs
| 2.0″x3.9″
50mmx100mm| ****
Tools to Prepare
Documents / Resources
|
offgridtec R-BOX-NEMA3 Battery Cabinet Floor
Mounting
[pdf] Instruction Manual
R-BOX-NEMA3 Battery Cabinet Floor Mounting, R-BOX-NEMA3, Battery Cabinet Floor
Mounting, Cabinet Floor Mounting, Floor Mounting
---|---