PHILIPS G6-RC132V Core Line Panel Owner’s Manual
- September 26, 2024
- Philips
Table of Contents
**PHILIPS G6-RC132V Core Line Panel Owner’s Manual
**
What In The Box
Lifetime Table | Lumen | CRI | 50K hrs | 100K hrs |
---|---|---|---|---|
2900 – 4300lm | 80 | L90 | L80 | |
5000lm | 80 | L85 | L75 | |
3100 – 4300lm | 90 | L85 | L75 |
| Lumen(lm)| CCT(K)| P(W)| IP| IK| L×W×H1/H2(mm)|
---|---|---|---|---|---|---|---
RC132V G6 36S/840 PSU W60L60 NOC| 3600| 4000| 26| IP44/IP20| IK03|
595x595x36/61| 1.70
RC132V G6 36S/840 PSU W30L120 NOC| 3600| 4000| 26| IP44/IP20| IK03|
295x1195x36/61| 1.90
RC132V G6 36S/840 PSU W60L60 OC| 3600| 4000| 26| IP44/IP20| IK02|
595x595x37/62| 2.00
RC132V G6 36S/840 PSU W30L120 OC| 3600| 4000| 26| IP44/IP20| IK02|
295x1195x37/62| 2.20
RC132V G6 36S/840 PSD W60L60 OC| 3600| 4000| 26| IP44/IP20| IK02|
595x595x37/62| 2.00
RC132V G6 36S/840 PSD W30L120 OC| 3600| 4000| 26| IP44/IP20| IK02|
295x1195x37/62| 2.00
RC132V G6 29_36_43S/830_40 PSU W60L60 OC| 2900/* 3600 /4300| 3000/3500/
*4000*| 22/ 26 /31| IP44/IP20| IK02| 595x595x37/62| 2.00
RC132V G6 29_36_43S/830_40 PSD W60L60 OC| 2900/ 3600 /4300| 3000/3500/
4000| 22/ 26 /31| IP44/IP20| IK02| 595x595x37/62| 2.00
RC132V G6 50S/840 PSD W60L60 OC| 5000| 4000| 38| IP44/IP20| IK02|
595x595x37/62| 2.00
RC132V G6 29_36_43S/830_40 PSDW30L120OC| 2900/ 3600 /4300| 3000/3500/
4000| 22/ 26 /31| IP44/IP20| IK02| 1195x295x37/62| 2.20
RC132V G6 29_36_43S/830_40 PSU W60L60NOC| 2900/ 3600 /4300| 3000/3500/
4000| 22/ 26 /31| IP44/IP20| IK03| 595x595x36/61| 1.70
RC132V G6 31_36_43S/940 PSD W60L60 OC| 3100/ 3600 /4300| 4000| 26/
31 /38| IP44/IP20| IK02| 595x595x3/62| 2.00
RC132V G6 34S/830 WIA W60L60 OC| 3400| 3000| 26| IP44/IP20| IK02|
595x595x37/71| 2.05
RC132V G6 36S/840 WIA W60L60 OC| 3600| 4000| 26| IP44/IP20| IK02|
595x595x37/71| 2.05
RC132V G6 43S/840 WIA W60L60 OC| 4300| 4000| 31| IP44/IP20| IK02|
595x595x37/71| 2.05
| | | | | | |
| Lumen(Lm)| CCT(K)| P(W)| IP| IK|
LxWxH1/H2(mm)|
---|---|---|---|---|---|---|---
RC132V G6 365/840 WIA W30L120 OC| 3600| 4000| 26| 1P44/1P20| IK02|
1195x295x37/71| 2.25
RC132V G6 40_43S/830_40 WIA 60×60 OC| 2900/3600/4300| 3000/3500/4000| 31|
1P44/1P20| IK02| 595x595x37/71| 2.05
RC132V G6 40_435/830_40 WIA 30×120 OC| 2900/3600/4300| 3000/3500/4000| 31|
1P44/1P20| IK02| 1195x295x37/71| 2.25
RC132V G6 345/830 PSU W60L60 NOC| 3400| 3000| 26| 1P44/1P20| 11(03|
595x595x36/61| 1.70
RC132V G6 345/830 PSU W60L60 OC| 3400| 3000| 26| 1P44/1P20| 11(02|
595x595x37/62| 2.00
RC132V G6 365/UE840 PSU W60L60 NOC| 3600| 4000| 22.5| 1P44/1P20| 11(03|
595x595x36/70| 1.70
RC132V G6 365/UE840 PSU W60L60 OC| 3600| 4000| 22.5| IP44/1P20| IK02|
595x595x37/71| 2.00
C132V G6 365/UE840 PSD W60L60 OC| 3600| 4000| 23.5| 1P44/1P20| 11(02|
595x595x37/62| 2.00
RC132V G6 365/UE840 WIA W60L60 OC| 3600| 4000| 23.5| IP44/1P20| IK02|
595x595x37/62| 2.05
RC132V 66 31_36_435/840 PSU W60L600CUKI| 3100/3600/4300| 4000| 22/’26/31|
IP44/1P20| IK02| 595x595x35/60| 2.12
Default setting**| | | | | | |
Dimension
Available as accessory (Need to purchase separately)
Suspension set:
911401809387
RC159Z Suspension set SME-4 WH
911401809487
RC159Z Suspension set SME-3 WH
Surface mounted set:
911401807787
RC159Z SMB W60L60
911401807987
RC159Z SMB W30L120
Plaster ceiling set:
911401809287
RC159Z Plaster Ceiling
SMB-PLC
Safety cable:
911401809187
RC159Z Safety Cable
Quick-connectors
VPC Visible Profile Ceiling/Lay-in mounting
Optional with 9114018091-87 RC159Z Safety Cable
PCV plaster ceiling version (K02)
Optional with 911401809287 RC159Z Plaster Ceiling SMB-PLC
Surface mounted
Optional with
911401807787:RC159Z SMB W60L60
911401807987:RC159Z SMB W30L120
Suspension
Optional with
911401809387 RC159Z Suspension set SME-4 WH
911401809487 RC159Z Suspension set SME-3 WH
830/840
CRI80
| Lumen selectable| 3000K| 3500K/4000K| Wattage| lout
---|---|---|---|---|---
High| 4000lm| 4300lm| 31W| 650mA
Middle| 3400lm| 3600lm| 26W| 550mA
Low| 2900lm| 3100lm| 22W| 480mA
940 CRI90| Lumen selectable| 4000K| Wattage| lout
---|---|---|---|---
High| 4300lm| 38W| 800mA
Middle| 3600lm| 31W| 650mA
Low| 3100lm| 26W| 550mA
Inrush current
| PSU| PSD| WIA
---|---|---|---
| 22.5W| 26W| 31W| 38W| 23.5W| 26W| 31W| 38W
Electrical characteristics
Imax(A)| 20| 16| 20| 22| 22.6| 25.2| 26| 26.8| 4.8
Tref (us)| 200| 200| 220| 250| 254| 260| 260| 264| 56
MCB| No. of luminaires max.
B-10 A| 14| 18| 13| 12| 7| 9| 8| 8| 32
B-1 6A| 23| 30| 21| 20| 11| 17| 15| 15| 50
C-10 A| 24| 32| 23| 21| 11| 17| 15| 15| 52
C-1 6A| 40| 51| 37| 33| 17| 29| 28| 27| 85
This product contains a light source of energy efficiency class: C
The light source and/or control gear and/or the external flexible cable contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.
Disconnect before servicing
Luminaire has basic insulation between low voltage supply and control conductors.
The light source contained in this luminaire and the external flexible cable shall only be replaced by the manufacturer or his service agent or a similar qualified person.
Storage, installation, use, operation and maintenance of the products needs to be performed exactly according the instructions in this manual and/or other instructions as may be provided by us to guarantee safe use of the product over its entire lifetime. Failure to adhere to these instructions will invalidate your entitlement to warranty. Bolts with indication of torque strength on the drawing need to be tightened using a calibrated torque wrench. Pre-assembled bolts need to be retightened again to the required torque specification to assure maximum strength over lifetime.
SR compatibility
For SR-based luminaires only SR-Certified components/sensors are to be used (see also: http://www.lightino.philips.co.ukloem-emea/products/drivinq- connected-liqhtinql. The functional compatibility of two (SR-certified) components/sensors to be used in combination, as well as the override possibility of any line-switch function used in an SR-based luminaire, is to be released by the master component/sensor supplier. If using a NEMA 7-pin socket on an SR-based luminaire, a full system verification is required. Not following this advice can/will cause risk of damage and non-compliance for which Signify cannot take any responsibility.
WEEE Statement
Please inform yourself about the local waste disposal, separation and collection system for electrical and electronic products and packaging. Please act according to your local rules and do not dispose your old product and packaging with your normal household waste. The correct disposal of the packaging, your product and/or batteries will help prevent potential negative consequences for the environment and human health. Batteries should be disposed separately from the municipal waste stream via designated collection facilities. When disposing a product that contains non-user replaceable batteries, the non-user replaceable batteries shall be removed by a professional.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>