mitoredlight 1070nm Intranasal Unit User Manual

September 24, 2024
mitoredlight

1070nm Intranasal Unit

Product Information

Specifications:

  • Product Name: MitoMIND 1070nm Intranasal Unit
  • Wavelength: 1070nm near infrared light
  • Delivery Route: Intranasal
  • Components: Main panel, Sleeve charge line, Nasal probe
    silicone, Packing case, Nasal irradiation probe, Manual

Product Usage Instructions:

1. Assembly:

Before using the nasal irradiation probe, remove the silicone
sleeve of the nasal probe from the packaging box and insert it into
the irradiation probe.

2. Connection:

Connect one end of the nasal irradiation probe to the control
main unit and insert the other end into the nasal cavity.

3. Power On:

Press the ON/OFF button for two seconds to power on the device.
Select the desired session time.

4. Mode Selection:

Press the MODE button to cycle through modes:

  • M1 – two lights are on (recommended for general use)
  • M2 – only left light on
  • M3 – only right light on

5. Start Session:

Press POWER to start the session. To end early, press the POWER
button.

6. Safety Precaution:

Avoid shining the nasal probe directly into your eyes. As 1070nm
light is not visible, use a cell phone camera in a dark environment
to confirm light output.

FAQ

Q: Can I clean the nasal probes?

A: Nasal probes may develop skin allergies or irritation if
exposed to soap, sweat, allergens, or contaminants for extended
periods. It is recommended to follow the cleaning instructions
provided in the manual.

Q: Can I charge the device with a different charger?

A: This machine uses a specific charger, and it is strictly
prohibited to use a power supply with higher voltage for charging
to prevent potential accidents.

USER MANUAL
1070nm Intranasal Unit
www.mitoredlight.com
© 2024 Mito Red Light, Inc. All rights reserved.

CONTENTS
Introduction ……………………………………………………………………………………………………… 03 What’s included …………………………………………………………………………………………….. 05 Instructions ………………………………………………………………………………………………………. 06 Specifications and disposal ……………………………………………………………………. 08 Cautions and disclaimer ………………………………………………………………………….. 09 Warranty and maintenance …………………………………………………………………….. 10 About us ……………………………………………………………………………………………………………….. 11

INTRODUCTION
The MitoMIND 1070nm intranasal unit, allows you to bypass the skull in delivering 1070nm near infrared light to the brain. Combined with the MitoMIND 810nm Helmet, you get the two best brain health wavelengths, in two distinct delivery routes.
To ensure the longevity of your device, please read the below cautions and disclaimers. Further disclaimers and warranty information can be found at the end of this user manual:
Please avoid subjecting the therapeutic device to strong shocks and extremely high temperatures.
This machine uses a specific charger, so it is strictly prohibited to use a power supply with higher voltage for charging.
After charging is complete, disconnect the charging cable to prevent potential accidents caused by prolonged charging.
Please keep liquids out of the main unit to prevent damage to internal components.
Nasal probes may develop skin allergies or irritation if exposed to soap, sweat, allergens, or contaminants for extended periods.
Please do not attempt to disassemble, repair, or modify this machine yourself.
Avoid contact with chemicals such as gasoline, cleaning solvents, propanol, alcohol, or insect repellent.

www.mitoredlight.com

3

INTRODUCTION
The nose is a crucial part of the respiratory system connected to the lungs. Inflammation caused by pathogenic bacteria and viruses in the nose can spread to other areas, leading to complications in the brain, eyes, ears, throat, and lungs.
This nasal cavity therapeutic instrument utilizes a 1070 nm soft laser to repair damaged nasal mucosa tissue, enhance detoxification metabolism and the natural immune response of nasal tissue, accelerate capillary blood circulation in the mucosa, and boost the bactericidal activity of phagocytes. It helps reduce nasal tissue swelling, improve nasal airflow, decrease histamine release from mast cells, and alleviate nasal allergic reactions.
Warning: Do not shine the nasal probe directly into your eyes.

4

www.mitoredlight.com

WHAT’S INCLUDED
Main panel Sleeve charge line Nasal probe silicone Packing case Nasal irradiation probe Manual

www.mitoredlight.com

5

INSTRUCTIONS

Before using the nasal irradiation probe, remove the silicone sleeve of the nasal probe from the packaging box and insert it into the irradiation probe. See Figure 1.
Once the assembly is complete, connect one end of the nasal irradiation probe to the control main unit, and insert the other end into the nasal cavity. See Figure 2.

6

www.mitoredlight.com

INSTRUCTIONS
Next, power on your device by pressing on the ON/OFF button for two seconds, then select the amount of time you would like to use the unit for.
Next, you will need to select a mode. Press the MODE button until you see your desired mode. M1 is recommended for general use.
M1 – two lights are on M2 – only left light on M3 – only right light on
Once the mode is selected, press POWER to start your session. To end your session early, press the POWER button.
Please note, as 1070nm is past the visible spectrum it may be hard to see the light. Please do not look at the nasal probe to verify the light is on. If you would like to confirm the light is coming out, use your cell phone and take a picture of the nasal probe in a dark environment.
Remember to press the ON/OFF button after selecting the time, mode, and power for the session. If the ON/OFF button is not pressed, the device will automatically turn off after a minute to save power.
General usage: We recommend starting off a lower time limit of up to 15 minutes once a day, and over the space of two weeks build your time up to 15 to 30 minutes once a day. We do recommend taking one day off per week. If you have any unwanted effects, discontinue use and contact customer service.
Charging: When the power battery displays low battery, it is time to recharge your unit. Use the provided USB cord and connect to a USB charger (not provided) to charge your unit to full charge and then remove from the charger to preserve the life of your unit.

www.mitoredlight.com

7

SPECIFICATIONS AND DISPOSAL
Laser medium | QSI Laser wavelength | 1070nm Terminal laser output | 2 nasal cavity laser beams Laser output power | 2-5 mw Laser operating voltage | 3.7V Input voltage of power | 5V switching adapter Timing range | 15-60 minutes that can be adjusted Environment temperature | 20 – 40 Relative humidity | 85% Atmospheric pressure | 86 kpa — 106 kpa Power source use | Lithium ion battery with the capacity 1600 m Ah Lithium battery voltage | DC 3.7V – 4.2V
Disposal
Before disposing of the appliance, remove the battery from the device by following these steps: tear off the bottom pad, unscrew the bottom cover plate, and carefully extract the battery, ensuring to avoid short-circuiting the positive and negative poles.
Ensure the appliance is powered off before removing the battery, and dispose of it safely.
It is forbidden to throw the device into a fire to prevent it from exploding.

8

www.mitoredlight.com

CAUTIONS AND DISCLAIMER
Disclaimer
The statements in this manual have not been evaluated by the Food and Drug Administration (FDA). The information provided is not intended to diagnose, treat, cure, or prevent any disease and should not be construed as medical advice. Our products are low-risk, general wellness / fitness products that do not require FDA clearance, in accordance with the “General Wellness: Policy on Low Risk Devices” draft released January 20, 2015.
Mito Red Light makes no claims or representations or otherwise warranties regarding the ability of this product to cure any physical or mental conditions. A qualified health professional should always be consulted prior to using this product in regards to any condition that may requires medical attention.

www.mitoredlight.com

9

WARRANTY AND MAINTENANCE
Under normal use this product is guaranteed for 1 year after its original purchase date against manufacturing defects in materials or workmanship. This warranty extends only to the original purchaser. If the product should become faulty within the warranty period, contact Mito Red Light. Mito Red Light reserves the right to repair a defective product. Mito Red Light reserves the right to replace a defective product with the most compatible product currently available.
This warranty does not cover damage caused by the following: – Accident, misuse, abuse or alteration – Servicing by unauthorized persons -Connection to incorrect power sources -Use with unauthorized accessories
Mito Red Light shall not be responsible for any incidental, special or consequential damages resulting from the use of this product.

MAINTENANCE
This device has no serviceable parts. The battery is not accessible and not serviceable. Users should not attempt to service the battery as this will damage the device and void the warranty. Charge the device only with the supplied USB-C power charging cord and a universal USB-C power adapter (not included). The battery capacity grid will begin to flash when battery levels are low. This indicates the device should be recharged. The lifetime of the Lithium lon Battery can be maximized by allowing it to fully charge and then fully discharge during regular use.

10

www.mitoredlight.com

ABOUT
Located in Scottsdale, Arizona, Mito Red Light is dedicated to bringing the highest powered, highest quality red light therapy lights to market at the best possible value. Having extensively studied and realized the benefits of red light therapy firsthand, Mito Red Light was brought into existence in order to provide consumers truly affordable, yet highly effective red light therapy options.
If you have any further questions, please feel free to contact us at: info@mitoredlight.com
You can also call our phone number Monday – Friday 9am – 5pm MST 1 (866) 861- MITO
Mail correspondence can be sent to: Mito Red Light, Inc 9319 N 94th Way, Suite 400
Scottsdale, AZ 85258

www.mitoredlight.com

11

User Manual and Instructional Videos This user manual and instructional videos can be found here:
https://mitoredlight.com/pages/user-manual
Updated May 2024 www.mitoredlight.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals