Dimplex DCP9C Portable Air Conditioner Instruction Manual
- September 23, 2024
- Dimplex
Table of Contents
Dimplex DCP9C Portable Air Conditioner
Product Usage Instructions
Before using the Portable Air Conditioner, ensure to follow these safety precautions:
- Avoid placing the appliance in areas with flammable materials.
- Do not expose the unit to water or near a naked flame.
- Avoid locations where the power cable may be damaged or interfere with foreign objects.
- Do not attempt DIY repair on the product.
You can control the unit either through the control panel or the remote controller. The control panel includes various functions such as temperature adjustment, mode selection, fan speed control, timer settings, and power on/off.
FAQ
- Q: Can this air conditioner be used in commercial settings?
- A: No, this Portable Air Conditioner is designed for domestic household use only.
- Q: What refrigerant does this unit use?
- A: This air conditioner uses R290 refrigerant, which is flammable. Follow all safety precautions when using this appliance.
- Q: Can I repair this product myself?
- A: No, this product is not meant for DIY repair. Please contact a qualified technician for any repairs or servicing.
IMPORTANT
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE.
Note also the information presented on the appliance.
CAUTION: FAILURE TO FOLLOW THESE INSTRUCTIONS MAY CAUSE INJURY AND/OR DAMAGE AND MAY INVALIDATE YOUR WARRANTY
Please read the operating instructions carefully before using your Portable
Air Conditioner for the first time and keep them in a safe place.
WARNING – This appliance must not be used in a bathroom.
WARNING – Do not use this appliance in the immediate surroundings of a
bath, a shower or a swimming pool.
- If the mains lead is damaged it must only be replaced by the manufacturers service agent or a similarly qualified person in order to avoid a hazard.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure they do not play with the appliance.
- Prior to cleaning or other maintenance, the appliance must be disconnected from the supply mains.
- Never immerse the appliance in water or other liquids.
- Operate this unit only on a firm, flat surface to avoid the risk of water leakage. Ensure that the unit is kept upright at all times.
- Do not place on soft, unstable or non-horizontal/angled surfaces.
- Never operate the appliance if a cable or connector has been damaged, after appliance malfunction or if the appliance was dropped or is otherwise damaged.
- Please ask a professional service agent to repair the product. Improper repair may cause danger to users.
- Disconnect the appliance from mains power whenever it is not in use, before relocating it, and before cleaning.
- Operate the appliance only at the voltage specified on the rating label.
- Only connect the unit to a properly installed and easily accessible socket so that you can quickly disconnect the plug if necessary.
- Do not connect this product to the mains using an extension lead.
- This product is only intended for INDOOR RESIDENTIAL applications. This product should not be used for commercial or industrial or leisure applications or in small enclosed spaces.
- Never use the mains lead as a carrying strap or pulling lead.
- To avoid a fire or electrocution hazard, NEVER put the cord near heat registers, radiator, stoves or heaters.
- DO NOT cover cord with carpeting, throw rugs, runners, or similar coverings.
- DO NOT route cord under furniture or appliances. Take care to position the cord away from traffic areas and where it will not be a tripping hazard.
- DO NOT use the unit near windows or where water collects. Rain and water collection may lead to a risk of fire or electric shock.
- Only operate this appliance with a minimum of 50cm clearance all around i.e. away from walls, furniture and overhanging objects such as curtains or a shelf.
- WARNING: To avoid danger of suffocation please remove all packaging materials particularly plastic and EPS and keep these away from vulnerable people, children and babies.
- NEVER drop or insert any object or fingers into any openings.
- Do not cover or obstruct the air inlet and outlets.
- Do not use the appliance in locations where paint, petrol or other flammable liquids are used or stored.
- Do not use bug sprays or other flammable cleansers/vapour sprays on or around the unit.
- Always switch off the unit and take the plug out of the socket:
- If y ou are not using the unit
- Bef ore you clean or carry out maintenance on the unit
- If a f ault occurs
- In the event of an electrical storm.
- Avoid electromagnetic interference. Keep the unit at least 1 metre away from electrical appliances such as televisions & radios.
- The air conditioner must always be stored and transported upright. In case of doubt we suggest you wait for at least 24 hours before operation. (Please keep unit upright at all times).
- This portable air conditioner is fitted with a compressor delay protection circuit. This protects the unit from possible damage due to rapid starting and stopping of its compressor. The compressor will begin operationg 3 minutes after the unit has been switched ON or if the mode is changed from dehumidify to cooling.
- It is hazardous for anyone other than an Authorised Service Person to service this appliance. In Queensland – the authorised Service Person MUST hold a Gas Work Authorisation for hydrocarbon refrigerants to carry out servicing or repairs where the gas system is being opened or charged.
- This appliance shall be installed in accordance with national wiring regulations.
WARNING: For using R290 refrigerant. ThIs symbol shows that this appliance uses a flammable refrigerant. If the refrigerant is leaked and exposed to an external ignition source, there is a risk of fire.
CAUTION: RISK OF FIRE/FLAMMABLE MATERIALS. THE APPLIANCE MUST BE INSTALLED, USED & STORED IN AN AREA THAT IS GREATER THAN .
NB: These symbols on your device mean:
- This appliance is filled with Propane gas R290. Follow strictly the manufacturer’s instruction concerning use and repairs!
- Before using this appliance, you must carefully read the entire instruction manual.
- Do not install, operate or store the device in a room with a floor area smaller than 9m .
- Repairs must be performed based on the recommendations from the manufacturing company.
- Note also the information presented on the appliance.
- Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
- The appliance shall NOT be stored in a room with continuously operating ignition sources (for example: open flames, an operating gas appliance or an operating electric heater).
- Do not pierce or burn.
- Be aware that the refrigerants may not contain an odour.
- The appliance should be installed, operated and stored in a room with a floor area according to the amount of refrigerant to be charged. For specific information on the type of gas and the amount, please refer to the relevant label on the unit itself. When there are differences between the lable and the manual on the Min. room area description, the description on label shall prevail.
- Compliance with national gas regulations shall be observed.
- Keep ventilation openings clear of obstruction.
- The appliance shall be stored so as to prevent mechanical damage from occurring.
- A warning that the appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
- Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorises their competence to handle refrigerants safely in accordance with an industry recognised assessment specification.
- Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.
- Transport of equipment containing flammable refrigerants – see transport regulations
- Marking of equipment using signs – see local regulations
- Disposal of equipment using flammable refrigerants – see national regulations.
- Storage of equipment/appliances – The storage of equipment should be in accordance with the manufacturer’s instructions.
- Storage of packed (unsold) equipment – storage package protection should be constructed such that mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge. The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations.
- Information on servicing
Checks to the area
- Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with prior to conducting work on the system.
Work procedure
- Work shall be undertaken under a controlled procedure to minimize the risk of flammable gas or vapor being present while the work is being performed.
General work area
- All maintenance staff and others working in the local area shall be instructed on the nature of the work being carried out. Work in confined spaces shall be avoided. The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made safe by control of flammable material.
Checking for the presence of refrigerant
- The area shall be checked with an appropriate refrigerant detector before and during work, to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. non-sparking, adequately sealed or intrinsically safe.
Presence of a fire extinguisher
- If any hot work is to be conducted on the refrigeration equipment or any associated parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area.
No ignition sources
- No person carrying out work with a refrigeration system that involves exposing any pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion.
- All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repair, removing and disposal, during which flammable refrigerant can possibly be released to the surrounding space. Before work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. No Smoking signs shall be displayed.
Ventilated area
- Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.
Checks to the refrigeration equipment
- Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer’s maintenance and service guidelines shall be followed. If in doubt consult the manufacturer’s technical department for assistance. The following checks shall be applied to installations using flammable refrigerants:
- The charge size is by the room size within which the refrigerant-containing parts are installed;
- The ventilation machinery and outlets are operating adequately and are not obstructed;
- If an indirect refrigerating circuit is being used, the secondary circuit shall be checked for the presence of refrigerant; Marking to the equipment continues to be visible and legible. Markings and signs that are illegible shall be corrected; Refrigeration pipe or components are installed in a position where they are unlikely to be exposed
to any substance that may corrode refrigerant-containing components unless the components are constructed of materials that are inherently resistant to being corroded or are suitably protected against being so corroded.
Checks to electrical devices
- Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution shall be used. This shall be reported to the owner of the equipment so all parties are advised.
- Initial safety checks shall include:
- That capacitors are discharged: this shall be done safely to avoid the possibility of sparking; That there no live electrical components and wiring
are exposed while charging, recovering or purging the system; That there is continuity of earth bonding.
Repairs to sealed components
- During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers, etc. If it is necessary to have an electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.
- Particular attention shall be paid to the following to ensure that by working on electrical components, the casing is not altered in such a way that the level of protection is affected. This shall include damage to cables, excessive number
of connections, terminals not made to original specification, damage to seals, incorrect fitting of glands, etc. Ensure that the apparatus is mounted securely. Ensure that seals or sealing materials have not degraded such that they no longer serve the purpose of preventing the ingress of flammable atmospheres. Replacement parts shall be under the manufacturer’s specifications.
NOTE: The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment. Intrinsically safe components do not have to be isolated prior to working on them.
Repair to intrinsically safe components
Do not apply any permanent inductive or capacitance loads to the circuit
without ensuring that this will not exceed the permissible voltage and current
permitted for the equipment in use. Intrinsically safe components are the only
types that can be worked on while live in the presence of a flammable
atmosphere. The test apparatus shall be at the correct rating. Replace
components only with parts specified by the manufacturer. Other parts may
result in the ignition of refrigerant in the atmosphere from a leak.
Cabling
- Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects.
- The check shall also take into account the effects of aging or continual vibration from sources such as compressors or fans.
Detection of flammable refrigerants
- Under no circumstances shall potential sources of ignition be used in the search for or detection of refrigerant leaks. A halide torch (or any other detector using a naked flame) shall not be used.
Leak detection methods
The following leak detection methods are deemed acceptable for systems
containing flammable refrigerants. Electronic leak detectors shall be used to
detect flammable refrigerants, but the sensitivity may not be adequate or may
need re-calibration. (Detection equipment shall be calibrated in a
refrigerant-free area.) Ensure that the detector is not a potential source of
ignition and is suitable for the refrigerant used. Leak detection equipment
shall be set at a percentage of the LFL of the refrigerant and shall be
calibrated to the refrigerant employed and the appropriate percentage of gas
(25 %maximum) is confirmed. Leak detection fluids are suitable for use with
most refrigerants but the use of detergents containing chlorine shall be
avoided as the chlorine may react with the refrigerant and corrode the copper
pipe-work. If a leak is suspected, all naked flames shall be removed/
extinguished. If leakage of refrigerant is found that requires brazing, all of
the refrigerants shall be recovered from the system, or isolated (through
shut-off valves) in a part of the system remote from the leak. Oxygen-free
nitrogen (OFN) shall then be purged through the system both before and during
the brazing process.
Removal and evacuation
- When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used.
- However, best practice must be followed since flammability is a consideration.
- The following procedure shall be adhered to: Remove refrigerant; Purge the circuit with inert gas; Evacuate; Purge again with inert gas; Open the circuit by cutting or brazing.
- The refrigerant charge shall be recovered into the correct recovery cylinders.
- The system shall be flushed with OFN to render the unit safe.
- This process may need to be repeated several times. Compressed air or oxygen shall not be used for this task.
- Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved, then venting to the atmosphere, and finally pulling down to a vacuum.
- This process shall be repeated until no refrigerant is within the system.
- When the final OFN charge is used, the system shall be vented down to atmospheric pressure to enable work to take place.
- This operation is vital if brazing operations on the pipe work are to take place. Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available.
Charging procedures
- In addition to conventional charging procedures, the following requirements shall be followed. Ensure that contamination of different refrigerants does not occur when using charging equipment. Hoses or lines shall be as short as possible to minimize the amount of refrigerant contained in them.
- Cylinders shall be kept upright.
- Ensure that the refrigeration system is earthed before charging the system with refrigerant.
- Label the system when charging is complete (if not already).
- Extreme care shall be taken not to overfill the refrigeration system. Before recharging the system, it shall be pressure tested with OFN. The system shall be leak tested on completion of charging but before commissioning. A follow-up leak test shall be carried out before leaving the site.
Decommissioning
Before carrying out this procedure, the technician must be completely familiar
with the equipment and all its details. It is recommended good practice that
all refrigerants are recovered safely. Before the task being carried out, an
oil and refrigerant sample shall be taken in case analysis is required before
re-use of reclaimed refrigerant. Electrical power must be available before the
task is commenced.
- Become familiar with the equipment and its operation.
- Isolate system electrically.
- Before attempting the procedure ensure that: Mechanical handling equipment is available, if required, for handling refrigerant cylinders;All personal protective equipment is available and being used correctly; The recovery process is supervised at all times by a competent person; Recovery equipment and cylinders conform to the appropriate standards.
- Pump down refrigerant system, if possible.
- If a vacuum is not possible, make a manifold so that refrigerant can be removed from various parts of the system.
- Make sure that cylinder is situated on the scales before recovery takes place.
- Start the recovery machine and operate in accordance with manufacturer’s instructions.
- Do not overfill cylinders. (No more than 80 % volume liquid charge).
- Do not exceed the maximum working pressure of thecylinder, even temporarily.
- When the cylinders have been filled correctly and the process completed, make sure that the cylinders and the equipment are removed from site promptly and all isolation valves on the equipment are closed off.
- Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked.
Labeling
Equipment shall be labelled stating that it has been de-commissioned and
emptied of refrigerant. The label shall be dated and signed. Ensure that there
are labels on the equipment stating the equipment contains flammable
refrigerant.
Recovery
When removing refrigerant from a system, either for servicing or
decommissioning, it is recommended good practice that all refrigerants are
removed safely. When transferring refrigerant into cylinders, ensure that only
appropriate refrigerant recovery cylinders are employed. Ensure that the
correct number of cylinders for holding the total system charge is available.
All cylinders to be used are designated for the recovered refrigerant and
labeled for that refrigerant (i.e. special cylinders for the recovery of
refrigerant). Cylinders shall be complete with pressure relief valves and
associated shut-off valves in good working order. Empty recovery cylinders are
evacuated and, if possible, cooled before recovery occurs. The recovery
equipment shall be in good working order with a set of instructions concerning
the equipment that is at hand and shall be suitable for the recovery of
flammable refrigerants. In addition, a set of calibrated weighing scales shall
be available and in good working order. Hoses shall be complete with leak-free
disconnect couplings and in good condition. Before using the recovery machine,
check that it is in satisfactory working order, has been properly maintained
and that any associated electrical components are sealed to prevent ignition
in the event of a refrigerant release. Consult the manufacturer if in doubt.
The recovered refrigerant shall be returned to the refrigerant supplier in the
correct recovery cylinder, and the relevant Waste Transfer Note arranged. Do
not mix refrigerants in recovery units and especially not in cylinders. If
compressors or compressor oils are to be removed, ensure that they have been
evacuated to an acceptable level to make certain that flammable refrigerant
does not remain within the lubricant. The evacuation process shall be carried
out prior to returning the compressor to the suppliers. Only electric heating
to the compressor body shall be employed to accelerate this process. When oil
is drained from a system, it shall be carried out safely.
Specification
Model no. | DCP9C |
---|---|
Colour | White |
Power supply | 220-240V~50Hz |
Operating temperature | 17-35°C |
Thermostat range | 17-30°C |
Rated Input Power | 1.3kW |
Cooling Capacity | 2.6kW |
Noise Level Minimum (Lo) | 51dB(A) |
Noise Level Maximum (Hi) | 54dB(A) |
Air Volume (Lo/Hi) | 260/320 |
Refrigerant | R290 |
Fan speeds | 2 |
Modes | Cool, Dry & Fan |
Timer | 24 hours |
Dimensions (w x d x h) | 280 x 290 x 675mm |
Min room size | 9m2 |
Max room size | 20m2 |
Weight net | 20.8kg |
Weight gross | 27kg |
For greater precision, please always refer to the rating label placed on the product.
Parts
Control Panel
Remote Control
Installation
PREPARATION
NOTE: All the illustrations in the manual are for explanatory purposes
only. Your machine may be slightly different, but the actual shape will be
similar. The unit can be controlled by the unit control panel alone or with
the remote controller.
NOTE: Open the deflector before first time use
EXHAUST HOSE INSTALLATION
The exhaust hose and adaptor must be installed or removed under the usage
mode. For COOL mode the exhaust hose must be installed. For FAN or DRY mode,
the exhaust hose must be removed.
CHOOSING THE RIGHT LOCATION
Your installation location should meet the following requirements:
- Make sure that you install your unit on an even surface to minimize noise and vibration.
- The unit must be installed near a grounded plug, and the Collection Tray Drain (found on the back of the unit) must be accessible.
- The unit should be located at least 50cm from the nearest wall to ensure proper air circulation. The horizontal louver blade should be at least 50cm away from obstacles.
- DO NOT cover the Intakes, Outlets or Remote Signal Receptor of the unit, as this could cause damage to the unit.
NOTE: To ensure proper function, DO NOT overextend or bend the hose. Make
sure that there is no obstacle around the air outlet of the exhaust hose (in
the range of 500mm) to the exhaust system works properly. All the
illustrations in this manual are for explanatory purposes only. Your air
conditioner may be slightly different, the actual shape will be similar.
HOW TO STAY COOL WITH A PORTABLE AIR CONDITIONER
Because of a new MEPS test procedure for Portable Air Conditioners, you may
notice that the cooling capacity claims on portable air conditioner packaging
are significantly lower than those of models produced before 2020. This is due
to changes in the test procedure, not to the portable air conditioners
themselves.
TOOLS NEEDED
- Medium Philips screwdriver
- Tape measure or ruler
- Knife or scissors
- Saw (optional, to shorten window kit for narrow windows
ACCESSORIES
WINDOW INSTALLATION KIT
Preparing the Exhaust Hose assembly
- Extend either side of the hose (Fig. 1) and screw in the inlet (Fig. 2)
- Extend the other side of the hose and screw it to the hose outlet (Fig. 3)
Install the Exhaust hose assembly to the unit
-
Install the hose inlet into the unit (Fig. 4)
-
Affix the hose outlet into the window slider kit and seal (Fig. 5 & 6)
Preparing the Adjustable Window Slider
- Depending on the size of your window, adjust the size of the window slider and (optionally) secure it with screws.
- If the length of the window is less than the minimum length of the window kit, cut the end without the opeing short enough to fit.
NOTE: Once the Exhaust Hose assembly and Adjustable Window Slider are prepared, choose from one of the following two installation methods. Type 1: Hung Window or Sliding Window Installation (For some models).
Functions
ON/OFF
- Press to turn the unit on/off.
MODE
- Press the MODE button to select the appropriate operating MODE. The modes that can be selected, follow this sequence COOL > FAN and DRY. The selected mode indicator light will illuminate on the control panel.
FAN MODE
- Press the MODE button until the FAN indicator light comes on. Press the FAN SPEED button on the remote controller to choose the fan speed. The temperature can not be adjusted in this mode, only the fan speed. The exhaust hose needs to be removed during FAN MODE operation.
Up (-) / Down (+)
- The Up (+) and Down (-) buttons are used to adjust (increase/decrease) the temperature settings in 1°C increments. The temperature range can be set from 17°C to 30°C.
NOTE: The control panel is capable of displaying the temperature in
either degrees Fahrenheit or degrees Celsius. To convert from one to the
other, press and hold the Up and Down buttons at the same time for 3 seconds.
COOL MODE
- Press the MODE button until the COOL indicator light comes on. Press the Up (+) or Down (-) buttons to select the desired room temperature. Press the FAN SPEED button to adjust the fan speed. The exhaust hose needs to be used during COOL MODE operation.
DRY / DEHUMIDIFY
- Press the MODE button until the DRY ( ) indicator light comes on. The fan speed or temperature cannot be set during DRY MODE. The fan will automatically operate at LOW speed. NOTE: Keep windows and doors closed. The exhaust hose needs to be attached during DRY MODE operation.
SETTING THE TIMER
- This timer can be used to delay the appliance startup or shutdown, this avoids wasting electricity by optimizing operating periods.
PROGRAMMING START UP
- Turn on the appliance, choose the desired mode (e.g. COOL, 24°C, high fan speed). Turn off the appliance.
- Press the TIMER button, the Timer symbol and number of hours will flash.
- Press the UP/DOWN buttons until the desired time is displayed.
- Wait 5 seconds. The timer will be active and the TIMER symbol will light up.
- Press the TIMER button or the ON/OFF button to cancel the timer. and the TIMER symbol will disappear.
PROGRAMMING SHUT DOWN
- When the appliance is running, press the TIMER button. The TIMER symbol and the number of hours will flash.
- Press the UP/DOWN buttons until the desired time is displayed.
- Wait 5 seconds. The timer will be active, the TIMER symbol will light up.
- Press the TIMER button or the ON/OFF button to cancel the timer. and the TIMER symbol will dissapear.
TIPS FOR OPTIMAL USE
To get the best from your appliance, follow these recommendations:
- Close the windows and doors in the room to be air conditioned (fig. 21). When installing the appliance semi-permanently, a door should be left slightly open (as little as 1 cm) to guarantee optimal ventilation.
- Protect the room from direct exposure to the sun by partially closing curtains and/or blinds to make the appliance much more economical to run (fig. 22).
- Never rest objects of any kind on the appliance.
- Do not block the air inlet or outlet of the appliance. Reduced air flow will result in poor performance and could damage the unit (fig. 23).
- Make sure there are no heat sources in the room; Never use the appliance in very damp rooms (laundries for example).
- Never use the appliance outdoors.
- Ensure the appliance is standing on a level surface. If necessary, place the castor locks under the front wheels.
LED DISPLAY
- The LED display shows the set temperature while on COOL or AUTO MODE. While in DRY and FAN MODE, it shows the ambient room temperature.
ERROR CODES
- PROBE FAILURE (sensor damaged): if this is displayed, please contact your local authorised service centre
- FULL TANK (water tank is full): Empty the internal water tank, following the instructions in the Functions section.
Protection code
P1 – Bottom tray is full – Connect the drain hose and drain the collected water away. If protection repeats, call for technical assistance.
NOTE: When one of the above malfunctions occurs, turn the unit OFF, and
check for any obstructions. Restart the unit, if the malfunction is still
present, turn OFF the unit and unplug the power cord. Contact the manufacturer
or its service agents or a similar qualified person for service.
SLEEP/ECO MODE
This feature can only be activated by the remote control. To activate SLEEP
mode, press the SLEEP button on the remote control. The set temperature will
increase
(cooling) after 60 minutes. The set temperature will increase again by another
1°C after an additional 60 minutes. This new temperature will be maintained
for 6 hours. This ends the Sleep mode and the unit will automatically shut
off. The SLEEP function can be canceled at any time during operation by
pressing the SLEEP, MODE or FAN SPEED button.
NOTE: The SLEEP model cannot be used under FAN or DRY mode.
AUTO-RESTART
If the unit turns off unexpectedly due to a power cut, it will automatically
restart in the previous settings when the power resumes.
WAIT 3 MINUTES BEFORE RESUMING THE OPERATION
After the unit has been turned off, it can not be restarted in the first 3
minutes. This is to protect the unit & compressor. The operation will
automatically start after 3 minutes.
AIRFLOW DIRECTION ADJUSTMENT
The vertical louvers need to be adjusted manually. Always ensure the unit is
OFF when making manual adjustments.
- Angle the louvres in the direction required
- Do not place any heavy objects on or block the louvres, doing so will cause damage to the unit.
- Ensure the louvre is always fully open during operation.
POWER MANAGEMENT
Under cooling operation, when the ambient temperature is lower than the set
temperature for a while, the unit will be automatically operate the power
management feature. The compressor and fan motor will stop. When the ambient
temperature is higher than the set temperature, the unit will automatically
quit power management mode and the compressor and/or fan motor will run.
WATER DRAINAGE
When there is excess water condensation inside the unit, the appliance will
cease function and play the Full Tank icon ( ). This indicates that the water
tank needs to be drained using the following procedure.
MANUAL DRAINING (Fig 24)
- Unplug the unit from power source.
- Place a pan (not the unit’s tank) under the lower drain plug. See diagram.
- Remove the lower drain plug.
- Water will drain out and collect in the pan.
- After the water is drained, replace the lower drain plug firmly.
- Turn the unit on
CONTINUOUS DRAINING (Fig 25)
While using the unit in dry mode, continuous drainage is recommended.
- Unplug the unit from the power source.
- Remove the drain plug. While doing this operation some residual water may spill, a pan is recommened to collect the water.
- Connect a drain hose (12.7mm or 1/2″). See diagram.
- The water can be continuously drained through the hose.
- Turn the unit on
NOTE: Make sure the hose is secure so there are no leaks. Direct the hose toward the drain, making sure that there are no kinks that will stop the water flowing. Place the end of the hose into the drain and make sure the end of the hose is down to let the water flow smoothly. When the continuous drain hose is not used, ensure that the drain plug and knob are installed firmly to prevent leakage.
Remote Control
Using the Remote Control
- Open the battery cover of the remote control, and insert 2 x AAA batteries.
- Please point to the receiver and be within 8m when using the remote control.
- If the battery voltage is low, please open the battery cover as per the diagram and replace with new batteries (2 x AAA). Then replace the battery cover.
Cleaning
SAFETY PRECAUTIONS
- Always unplug the unit before cleaning or servicing.
- DO NOT use flammable liquids or chemicals to clean the unit.
- DO NOT wash the unit under running water. Doing so causes electrical danger.
- DO NOT operate the machine if the power supply was damaged during cleaning. A damaged power cord must be replaced with a new cord from the manufacturer.
AIR FILTER
CAUTION: DO NOT operate the unit without a filter because dirt and lint
will clog it and reduce performance.
- Be sure to clean the air filter every 2 weeks for optimal performance.
- The water collection tray should be drained immediately after P1 error occurs, and before storage to prevent mould.
- In households with animals, you will have to periodically wipe down the grill to prevent blocked airflow due to animal hair.
OUTSIDE CABINET
- Remove any dust buildup with a soft brush.
- Wipe the surface of the unit with a soft damp cloth. Mild detergent can be used for any stubborn marks.
DO NOT use abrasive sponges, scouring pads, or a stiff brush to clean the
unit.
IMPORTANT
The control panel and other parts must not come into contact with water or any
other liquids.
Maintenance
Storage
If not using the unit for an extended period. After cleaning please:
- Turn the unit off, unplug and take care of the mains lead & plug.
- Drain the unit’s water collection tray according to the instructions in the following section.
- Run the appliance on FAN mode for 12 hours in a warm room to dry it and prevent mould.
- Clean the air filter as described in the previous section.
- Remove batteries from the remote control
- Cover the unit and store it upright in a location where it will not receive direct sunlight. NB- Prolonged exposure to direct sunlight will discolour the enclosure.
If the unit fails to operate efficiently, is broken or other problems arise, unplug and do not operate. Ask for advice by calling your local after-sales service agent or the Customer Care Centre on 1300 556 816 (AU) / 0800 666 2824 (NZ).
Warranty
- Please refer to the warranty card in the box for warranty information. For any troubleshooting advice, please contact the relative Customer Care Centre below.
Glen Dimplex Australia Pty Ltd
- 8 Lakeview Drive,
- Scoresby 3179, Victoria Australia
- Ph: 1300 556 816
Glen Dimplex New Zealand Ltd
- 38 Harris Road, East Tamaki, Auckland 2013
- Ne Zealand
- Ph: 0800 666 2824
Recycling: Do not dispose of electrical appliances as unsorted municipal waste. Use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater, polluting the food chain and damaging health and well-being.
CONTACT
- Customer Care: 1300 556 816
- customer.care@glendimplex.com.au
- www.dimplex.com.au
- Supplied by Glen Dimplex Australia
- 8 Lakeview Drive, Scoresby, Victoria, 3179
© Glen Dimplex Australia. All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of Glen Dimplex Australia.