AERASGARD KLQ-SD-U Multi Functional Duct Sensors Owner’s Manual

September 22, 2024
AERASGARD

KLQ-SD-U Multi Functional Duct Sensors

“`html

Specifications:

  • Product Range: 2024
  • Manufacturer: REGELTECHNIK USA DIVISION

Product Information:

The multifunctional air quality sensors are measuring
transducers for mixed gas, including volatile organic compounds
(VOC), CO2, and fine dust (PM). These sensors are essential for
monitoring indoor air quality, particularly the levels of CO2 and
VOC, which are indicators of healthy room air.

Features:

  • Microprocessor control
  • Zero maintenance
  • Self-calibration
  • DIP switches for measuring range selection
  • Active/switched output
  • Optional features include changeover contact, display, and
    Modbus port

Models Available:

  • KLQ-SD-U: $247.35
  • KCO2-SD-U: $278.53
  • ACO2-SD-U: $284.93

Product Usage Instructions:

Duct Sensor for VOC and CO2 Content (KLQ-SD-U):

  1. Type: WG02
  2. Measuring Range: 0-100% VOC
  3. Output: 0-10 V
  4. Housing/Display: T1
  5. Item No.: 1501-3170-1001-500

Note: These units must not be used as
safety-relevant devices!

On-wall Sensor for CO2 Content (ACO2-SD-U):

  1. Type: WG02
  2. Measuring Range: 0-2000/5000 ppm
  3. Output: 0-10 V
  4. Display Item No.: 1501-7110-1001-200
  5. Price: $284.93

Note: These units must not be used as
safety-relevant devices!

FAQ:

Q: Can the sensors be retrofitted with a metal sinter

filter?

A: Yes, optionally, the devices can be supplied or retrofitted
with a metal sinter filter.

Q: What is the standard delivery inclusion for these

sensors?

A: Standard delivery includes a plastic sinter filter.

“`

AERASGARD®
MULTIFUNCTIONAL AIR QUALIT Y SENSORS MEASURING TRANSDUCERS FOR MIXED GAS (VOC), CO2 AND FINE DUST (PM)
PRODUCT RANGE 2024
REGELTECHNIK USA DIVISION

AERASGARD® AIR QUALIT Y SENSORS (DUCT/ ON-WALL)

KLQ-SD-U
$ 247. 3 5

KCO2 – SD – U
$278.53

KCO2 – W with display
$396.83

ACO2 – SD – U
$284.93

ACO2 – W with display
$478.88

Healthy room air essentially depends on the indoor content of CO2 and volatile organic compounds (VOC). The carbon dioxide exhaled by people is also considered an indicator of the microbial load and risk of infection in rooms. VOC are caused by chemicals used in construction materials, furniture and flooring as well as by tobacco smoke. However, neither of the two measurands can be converted into or derived from another.
At S+S, the choice is up to you: Our AERASGARD® sensors and measuring transducers are available with CO2 or VOC sensor as well as in innovative combinations of both. The VOC sensor changes its conductivity depending on the concentration, kind and proportional mixture of the gas molecules polluting the air. Its sensibility can be set to three different levels. The CO2 sensor is based on non-dispersive infrared (NDIR) technology and uses a dual-beam measuring method.
Even the basic models all provide microprocessor control, zero maintenance, self-calibration, DIP switches for measuring range selection and active / switched output. The duct devices are supplied with a flange for stable mounting. Optional features include changeover contact (W), display and Modbus port.

AERASGARD®

Duct sensor for VOC and CO2 content

Type / WG02

Measuring Range

Output

Housing / Display Item No.

Price USD

KLQ-SD-U

0…100 % VOC

0 – 10 V

T1

1501-3170-1001-500 $247.35

KLQ-W

0…100 % VOC

0 – 10 V / 4…20 mA, 1x Changeover contact

T1

1501-3150-7301-500 $258.18

KCO2-SD-U

0…2000 / 5000 ppm

0 – 10 V

T1

1501-3160-1001-200 $278.53

KCO2-W

0…2000 / 5000 ppm

0 – 10 V / 4…20 mA, 1x Changeover contact

T1

1501-3140-7301-200 $338.42

KCO2-W LCD

0…2000 / 5000 ppm

0 – 10 V / 4…20 mA, 1x Changeover contact

T1 1501-3140-7321-200 $396.83

KCO2-Modbus

0…5000 ppm

RS485

T2

1501-8110-6001-200 $436.94

KCO2-Modbus LCD

0…5000 ppm

RS485

T2 1501-8110-6071-200 $507.03

Note: These units must not be used as safety-relevant devices!

Housing: T1 = Tyr 1 / T2 = Tyr 2

AERASGARD®

On-wall sensor for CO2 content

Type / WG02

Measuring Range

Output

ACO2-SD-U

0…2000 / 5000 ppm

0 – 10 V

ACO2-W

0…2000 / 5000 ppm

0 – 10 V / 4…20 mA, 1x Changeover contact

ACO2-W LCD

0…2000 / 5000 ppm

0 – 10 V / 4…20 mA, 1x Changeover contact

ACO2-Modbus

0…5000 ppm

RS485

ACO2-Modbus LCD

0…5000 ppm

RS485

Note: These units must not be used as safety-relevant devices!

Display Item No. 1501-7110-1001-200 1501-7110-7301-200
1501-7110-7371-200 1501-7110-6001-200
1501-7110-6071-200 Housing: Tyr 2

Price USD $284.93 $408.80 $478.88 $436.94 $520.51

REGELTECHNIK | FÜHLBARE PRÄZISION

AERASGARD® MULTIFUNCTIONAL DUCT SENSORS

KTM – CO2 – SD – U Measuring transducer
$354.98
KLQ – CO2 – W
$454.34

KFTM – LQ – CO2 – W with display
$ 613 .19

KLQ-CO2 Modbus with two cable glands
$493.24

Depending on the product type, these duct devices are available in an aestetic Tyr 1 (compact) or Tyr 2 (wide) housing. They feature our patented PLEUROFORM multi-chamber duct pipe and are supplied including flange for stable installation.

Our new Modbus capable AERASGARD® multifunctional devices for measuring of CO2 and VOC have a particular fit in energy and cost efficient central solutions for on-demand monitoring and control of the air quality in manufacturing, living, office and venue environments.
w
Also available as a device variant with a sensor for humidity and temperature measurement. Standard delivery includes a plastic sinter filter. Optionally, the devices can also be supplied or retrofitted with a metal sinter filter.

AERASGARD®

Multifunctional duct sensors and measuring transducers

Type / WG02

Measuring Range / Readout SI*

Output

Display Item No.

KTM-CO2-SD-U

0…2000 / 5000 ppm ­35…+80 °C (­31…+176 °F)*

0 – 10 V

1501-8112-1001-200

KLQ-CO2-W

0…2000 / 5000 ppm, 0…100 % VOC

0 – 10 V / 4…20 mA, 1x Changeover contact

1501-8111-7301-500

KLQ-CO2-W LCD

0…2000 / 5000 ppm, 0…100 % VOC

0 – 10 V / 4…20 mA, 1x Changeover contact 1501- 8111- 7371- 50 0

KFTM-CO2-W

0…2000 / 5000 ppm

0 – 10 V / 4…20 mA, 1x Changeover contact

0…100 % RH, ­35…+80 °C (­31…+176 °F)*

1501-8116-7301-200

KFTM-CO2-W LCD

0…2000 / 5000 ppm

0 – 10 V / 4…20 mA, 1x Changeover contact 1501- 8116- 7371- 20 0

0…100 % RH, ­35…+80 °C (­31…+176 °F)*

KFTM-LQ-CO2-W

0…2000 / 5000 ppm, 0…100 % VOC

0 – 10 V / 4…20 mA, 1x Changeover contact

0…100 % RH, ­35…+80 °C (­31…+176 °F)*

1501-8118-7301-500

KFTM-LQ-CO2-W LCD

0…2000 / 5000 ppm, 0…100 % VOC

0 – 10 V / 4…20 mA, 1x Changeover contact 1501- 8118- 7371- 50 0

0…100 % RH, ­35…+80 °C (­31…+176 °F)*

xx-Modbus

Measuring Range / Readout Imperial

KLQ-CO2-Modbus

0…5000 ppm, 0…100 % VOC

RS485

1501-8111-6001-500

KLQ-CO2-Modbus LCD

0…5000 ppm, 0…100 % VOC

RS485

1501-8111-6071-500

KFTM-CO2-Modbus

0…5000 ppm 0…100 % RH, ­31…+176 °F

RS485

1501-8116-6001-200

KFTM-CO2-Modbus LCD

0…5000 ppm 0…100 % RH, ­31…+176 °F

RS485

1501-8116-6071-200

KFTM-LQ-CO2-Modbus

0…5000 ppm, 0…100 % VOC 0…100 % RH, ­31…+176 °F

RS485

1501-8118-6001-500

KFTM-LQ-CO2-Modbus LCD 0…5000 ppm, 0…100 % VOC 0…100 % RH, ­31…+176 °F

RS485

1501-8118-6071-500

Note: These units must not be used as safety-relevant devices!

Housing: Tyr 2

Price USD $354.98 $454.34 $523.00 $434.12 $475.87 $544.52 $613.19
$493.24 $576.28 $448.20 $546.73 $586.14 $688.87

REGELTECHNIK | FÜHLBARE PRÄZISION

AERASGARD® MULTIFUNCTIONAL ON-WALL SENSORS / IN-WALL SENSOR
FSFTM – CO2 – Modbus P
$538.17

ALQ-CO2 Modbus with display and two cable glands
$688.87

ATM-CO2-SD-U
$ 3 6 2 .71

AFTM – LQ – CO2 – W with display and
plastic sinter filter
$820.85

FSLQ-U
$285.97

AERASGARD®
Type / WG02 FSLQ-U

Multifunctional in-wall sensors in the panel switch programme

Measuring Range / Readout SI*

Output

0…100 % VOC

0 -10 V

FSCO2-U

0…2000 ppm

KCO2 – WFSTM-CO2-U with displxaxy-Modbus

0…2000 ppm, 0…+50 °C (+32…+122 °F)* Measuring Range / Readout Imperial

FSFTM-CO2-Modbus

0…5000 ppm, 0…100 % RH, +32…+122 °F

FSFTM-CO2-Modbus P

0…5000 ppm, 0…100 % RH, +32…+122 °F with potentiometer

Note: These units must not be used as safety-relevant devices!

0 -10 V 0 -10 V
RS485 RS485

Item No.

Price USD

1501-5120-1000-162 $285.97

1501-9120-1001-162 $393.29 1501-9122-1001-162 $398.80

1501-9226-6001-162 $436.06 1501-9226-6501-282 $538.17 Housing: in-wall

AERASGARD®

Multifunctional on-wall sensors and measuring transducers

Type / WG02

Measuring Range / Readout SI*

ATM-CO2-SD-U

0…2000 / 5000 ppm ­35…+80 °C (­31…+176 °F)*

ALQ-CO2-W

0…2000 / 5000 ppm, 0…100 % VOC

ALQ-CO2-W LCD

0…2000 / 5000 ppm, 0…100 % VOC

AFTM-CO2-W

0…2000 / 5000 ppm 0…100 % RH, ­35…+80 °C (­31…+176 °F)*

AFTM-CO2-W LCD

0…2000 / 5000 ppm 0…100 % RH, ­35…+80 °C (­31…+176 °F)*

AFTM-LQ-CO2-W

0…2000 / 5000 ppm, 0…100 % VOC 0…100 % RH, ­35…+80 °C (­31…+176 °F)*

AFTM-LQ-CO2-W LCD

0…2000 / 5000 ppm, 0…100 % VOC 0…100 % RH, ­35…+80 °C (­31…+176 °F)*

xx-Modbus

Measuring Range / Readout Imperial

ALQ-CO2-Modbus

0…5000 ppm, 0…100 % VOC

ALQ-CO2-Modbus LCD

0…5000 ppm, 0…100 % VOC

AFTM-CO2-Modbus

0…5000 ppm 0…100 % RH, ­31…+176 °F

AFTM-CO2-Modbus LCD

0…5000 ppm 0…100 % RH, ­31…+176 °F

AFTM-LQ-CO2-Modbus

0…5000 ppm, 0…100 % VOC 0…100 % RH, ­31…+176 °F

AFTM-LQ-CO2-Modbus LCD

0…5000 ppm, 0…100 % VOC 0…100 % RH, ­31…+176 °F

Note: These units must not be used as safety-relevant devices!

Output 0 – 10 V

Display Item No. 1501-7112-1001-200

0 – 10 V / 4…20 mA, 1x Changeover contact 0 – 10 V / 4…20 mA, 1x Changeover contact 0 – 10 V / 4…20 mA, 1x Changeover contact

1501-7111-7301-500 1501-7111-7371-500
1501-7116-7301-200

0 – 10 V / 4…20 mA, 1x Changeover contact 1501- 7116- 7371- 20 0

0 – 10 V / 4…20 mA, 1x Changeover contact

1501-7118-7301-500

0 – 10 V / 4…20 mA, 1x Changeover contact 1501- 7118- 7371- 50 0

RS485 RS485 RS485
RS485
RS485
RS485

1501-7111-6001-500 1501-7111-6071-500
1501-7116-6001-200
1501-7116-6071-200
1501-7118-6001-500
1501-7118-6071-500
Housing: Tyr 2

Price USD $362.71 $545.24 $615.56 $523.65 $628.38 $685.75 $820.85
$588.96 $688.87 $548.13 $656.51 $700.44 $828.23

REGELTECHNIK | FÜHLBARE PRÄZISION

AERASGARD® MULTIFUNCTIONAL ROOM SENSORS

RLQ – SD – U (Baldur 1)
$200.60

RCO2 – SD – U (Baldur 1)
$244.08

RCO2-W-A with LED traffic light and changeover contact (Baldur 1)
$339.82

RCO2-AS with LED traffic light and
signal tone (Baldur 1)
$234.79

RFTM – CO2 – Modbus – P with display (Baldur 2)
$472.31

AERASGARD®

Multifunctional room sensors and measuring transducers

Type / WG02

Measuring Range / Readout SI*

Output

Housing / Display Item No.

Price USD

RLQ-SD-U

0…100 % VOC

0 – 10 V

B1

1501-61C0-1001-500 $200.60

RLQ-W

0…100 % VOC

0 – 10 V / 4…20 mA, 1x Changeover contact B1

1501-61C0-7301-500 $210.25

RLQ-W-A

0…100 % VOC

0 – 10 V / 4…20 mA, 1x Changeover contact B1, A 1501-61C0-7331-500 $239.88

RCO2-SD-U

0…2000 ppm

0 – 10 V

B1

1501-61A0-1001-200 $244.08

RCO2-W

0…2000 / 5000 ppm

0 – 10 V / 4…20 mA, 1x Changeover contact B1

1501-61A0-7301-200 $289.16

RCO2-W-A

0…2000 / 5000 ppm

0 – 10 V / 4…20 mA, 1x Changeover contact B1, A 1501-61A0-7331-200 $339.82

RCO2-W LCD

0…2000 / 5000 ppm

0 – 10 V / 4…20 mA, 1x Changeover contact B2 1501-61B0-7321-200 $347.15

RTM-CO2-SD-U

0…2000 ppm, 0…+50 °C (+32…+122 °F)* 0 – 10 V

B2

1501-61B2-1001-200 $267.23

RLQ-CO2-W

0…2000 / 5000 ppm, 0…100 % VOC

0 – 10 V / 4…20 mA, 1x Changeover contact B2

1501-61B1-7301-500 $436.94

RLQ-CO2-W LCD

0…2000 / 5000 ppm, 0…100 % VOC

0 – 10 V / 4…20 mA, 1x Changeover contact B2 1501-61B1-7321-500 $494.94

RFTM-CO2-W

0…2000 / 5000 ppm

0 – 10 V / 4…20 mA, 1x Changeover contact B2

0…100 % RH, 0…+50 °C (+32…+122 °F)*

1501-61B6-7301-200 $408.18

RFTM-CO2-W LCD

0…2000 / 5000 ppm

0 – 10 V / 4…20 mA, 1x Changeover contact B2 1501-61B6-7321-200 $452.72

0…100 % RH, 0…+50 °C (+32…+122 °F)*

RFTM-LQ-CO2-W

0…2000 / 5000 ppm, 0…100 % VOC

0 – 10 V / 4…20 mA, 1x Changeover contact B2

0…100 % RH, 0…+50 °C (+32…+122 °F)*

1501-61B8-7301-500 $479.17

RFTM-LQ-CO2-W LCD

0…2000 / 5000 ppm, 0…100 % VOC

0 – 10 V / 4…20 mA, 1x Changeover contact B2 1501-61B8-7321-500 $537.17

0…100 % RH, 0…+50 °C (+32…+122 °F)*

xx-Modbus

Measuring Range / Readout Imperial

RCO2-Modbus

0…5000 ppm

RS485

B2

1501-61B0-6001-200 $317.29

RCO2-Modbus LCD

0…5000 ppm

RS485

B2 1501-61B0-6021-200 $375.31

RLQ-CO2-Modbus

0…5000 ppm, 0…100 % VOC

RS485

B2

1501-61B1-6001-500 $465.10

RLQ-CO2-Modbus LCD

0…5000 ppm, 0…100 % VOC

RS485

B2 1501-61B1-6021-500 $523.09

RFTM-CO2-Modbus

0…5000 ppm 0…100 % RH, +32…+122 °F

RS485

B2

1501-61B6-6001-200 $374.39

RFTM-CO2-Modbus LCD

0…5000 ppm 0…100 % RH, +32…+122 °F

RS485

B2 1501-61B6-6021-200 $432.11

RFTM-CO2-Modbus P

0…5000 ppm, 0…100 % RH, +32…+122 °F with potentiometer

RS485

B2

1501-61B6-6501-271 $414.31

RFTM-CO2-Modbus P LCD 0…5000 ppm, 0…100 % RH, +32…+122 °F with potentiometer

RS485

B2 1501-61B6-6521-271 $472.31

RFTM-LQ-CO2-Modbus

0…5000 ppm, 0…100 % VOC 0…100 % RH, +32…+122 °F

RS485

B2

1501-61B8-6001-500 $507.34

RFTM-LQ-CO2-Modbus LCD 0…5000 ppm, 0…100 % VOC 0…100 % RH, +32…+122 °F

RS485

B2 1501-61B8-6021-500 $565.33

RCO2 -AS xx

CO2 sensor with traffic light indicator (5 LEDs) and acoustic signal NT = plug-in power supply unit / UPNT = in-wall power supply unit / ST = stainless steel stand holder

RCO2-AS

0…3000 ppm

0 – 10 V / 4…20 mA

B1, A 1501-61A0-0686-230 $234.79

RCO2-AS NT ST

0…3000 ppm

0 – 10 V / 4…20 mA

B1, A 1501-61A0-0686-231 $236.10

RCO2-AS NT

0…3000 ppm

0 – 10 V / 4…20 mA

B1, A 1501-61A0-0686-232 $239.81

RCO2-AS UPNT

0…3000 ppm

0 – 10 V / 4…20 mA

B1, A 1501-61A0-0686-233 $350.03

Note: These units must not be used as safety-relevant devices!

Housing: B1 = Baldur 1 / B2 = Baldur 2 / A = Traffic-light (5x LED)

REGELTECHNIK | FÜHLBARE PRÄZISION

AERASGARD® FINE DUST SENSOR (PM)

APS – SD (Tyr2)
$ 4 81. 3 6

RPS – SD without display
$ 3 5 7. 4 2

RFTM-PS-W without display
$466.25

RFTM-PS-CO2-W with display
$600.82

RFTM-LQ-PS-CO2 – Modbus with display
$713.41

Prevents fine dust in room air
The expanded range of our AERASGARD® devices now also detects harmful fine dust and inhalable aerosols with particle sizes from 0.3 to 10 µm. The fine dust content in the room air is measured by an exceptionally contamination- resistant laser sensor and issued in µg / m³. The fine dust sensors are designed as room devices and available in various expansion levels. From the basic model without a display all the way to the multifunctional measuring transducers with several measured values.

AERASGARD®
Type / WG02
APS – SD APS-SD-U
RPS – SD RPS-SD RFTM – PS – W RFTM-PS-W RFTM-PS-W LCD RFTM – PS – CO2 – W RFTM-PS-CO2-W
RFTM-PS-CO2-W LCD
Output:
Equipment: Note:

Multifunctional sensor and measuring transducer for fine dust (PM)

Measuring Range / Readout SI*

Humidity

Temperature

PM

CO2

Display Item No. VOC

(switchable)

(0-10 V)

­

­

0… 50 µg/m3

­

­

0…100 µg/m3

0…300 µg/m3

0…500 µg/m3

1501-7130-1001-000

(0-10 V)

­

­

(4x as above)

­

­

1501-2110-1001-000

(0-10 V / 4…20 mA)

0…100 % RH 0…+50 °C (4x as above)

­

(+32…+122 °F)*

­

W 1501-2116-7301-000

0…100 % RH 0…+50 °C (4x as above)

­

(+32…+122 °F)*

­

W 1501-2116-7321-000

(switchable)

(0-10 V / 4…20 mA)

0…100 % RH

0…+50 °C (4x as above)
(+32…+122 °F)*

0…2000 ppm / ­ 0…5000 ppm

W 1501-2113-7301-000

0…100 % RH

0…+50 °C (4x as above)
(+32…+122 °F)*

0…2000 ppm / ­ 0…5000 ppm

W 1501-2113-7321-000

0 -10 V or 4…20 mA (selectable via DIP switches, selected variant applies for all outputs) ­ Standard room sensor RPS – SD with fixed output 0 -10 V!

W = changeover contact ­ Standard room sensor RPS – SD without changeover contact !

These units must not be used as safety-relevant devices!

Price USD $481.36
$357.42 $466.25 $566.46
$542.81 $600.82

RFTM – PS – Modbus RFTM-PS-Modbus
RFTM-PS-Modbus LCD
RFTM – LQ – PS – CO2 – Modbus RFTM-LQ-PS-CO2-Modbus
RFTM-LQ-PS-CO2-Modbus LCD
Output: Note:

0…100 % RH 0…+50 °C 0…1000 µg/m3

­

(+32…+122 °F)*

0…100 % RH 0…+50 °C 0…1000 µg/m3

­

(+32…+122 °F)*

0…100 % RH

0…+50 °C 0…1000 µg/m3
(+32…+122 °F)*

5000 ppm

0…100 % RH

0…+50 °C 0…1000 µg/m3
(+32…+122 °F)*

5000 ppm

Modbus RS485

These units must not be used as safety-relevant devices!

­ ­
0…100 % 0…100 %

(Modbus) 1501-2116-6001-200
1501-2116-6021-200
(Modbus) 1501-2119-6001-500
1501-2119-6021-500

REGELTECHNIK | FÜHLBARE PRÄZISION

$432.44 $496.89
$655.42 $713.41

NEW

AERASGARD® SENSORS

RPCO2 without display
$472.65

AO2 without display
$710.96

AMS02-Modbus LCD
$1,756.66

AERASGARD® RPCO2 Room pendulum CO2 sensor or measuring transducer, Premium

Type / WG02

Measuring ranges Output 1

CO2

CO2

Output 2 CO2

Output switching

RPCO2 xx

switchable

RPCO2

0…2000 ppm / 0…5000 ppm / 0…10000 ppm

0 -10 V

4…20 mA

­

RPCO2 LCD

(3x as above)

0 -10 V

4…20 mA

­

RPCO2-W

(3x as above)

0 -10 V

4…20 mA

Changeover contact

RPCO2-W LCD

(3x as above)

0 -10 V

4…20 mA

Changeover contact

Note:

This unit must not be used as a safety-relevant device!

Item no. Display

Price USD

3CON-0203-0001-000 $472.65

3CON-0206-0001-000 3CON-0203-1001-000
3CON-0206-1001-000

$537.19 $488.53 $554.07

AERASGARD® AO2
Type / WG02
AO2 xx AO2-U AO2-U LCD AO2-U/W AO2-U/W LCD Note:

Wall-mounted oxygen sensor or measuring transducer, Premium

Measuring ranges Output

O2

O2

Output switching

Item no. Display

Price USD

0…25 %

0 -10 V

­

0…25 %

0 -10 V

­

0…25 %

0 -10 V

Changeover contact

0…25 %

0 -10 V

Changeover contact

This unit must not be used as a safety-relevant device!

3CON-0301-0004-000 3CON-0301-1004-000
3CON-0304-0004-000 3CON-0304-1004-000

$710.96 $837.07 $736.77 $862.87

AERASGARD® AMS
Type / WG02 AMS xx AMS01-Modbus LCD
AMS02-Modbus LCD
AMS03-Modbus LCD
Output: Calculated values: Note:

Wall-mounted multi-sensor Modbus, Deluxe

Measuring Range / Readout SI* Humidity/ Temp. PM Atm.pressure CO

Display Item no.

CO2

VOC

[µg/m3] [mbar] [ppm] [ppm] [%]

0…100 % RH
­20…+50 °C
(­4…+122 °F)*

0…1000 PM 2.5 PM 10

­

0…1000 0…10 000 0…100

3CON-0107-1005-000

0…20 000*

0…50 000*

0…100 % RH 0…1000

500-1150

­

0…10 000 0…100

3CON-0107-1006-000

­20…+50 °C PM 2.5

0…20 000*

(­4…+122 °F)* PM 10

0…50 000*

0…100 % RH
­20…+50 °C
(­4…+122 °F)*

0…1000 PM 2.5 PM 10

500-1150

0…1000

0…10 000 0…100 0…20 000 0…50 000

3CON-0107-1007-000

Modbus RTU

*(optional on request)

dew point temperature, absolute humidity, mixing ratio, wet bulb temperature, steam pressure

This unit must not be used as a safety-relevant device!

Price USD $1,792.24
$1,756.66
$1,899.80

REGELTECHNIK | FÜHLBARE PRÄZISION

The new S+S company headquarters on a total area of 14,000 m² in Nordostpark on the outskirts of Nuremberg offers a seamlessly integrated production and development environment with excellent air and road links.
S+S stands for a fully integral value chain. All products are designed, developed, manufactured and programmed in-house.

Development, manufacturing and sales in Nuremberg are certified by TÜV Thüringen according to DIN EN ISO 9001:2015 (quality management) and DIN EN ISO 14001:2015 (environmental management).
All devices are function tested as well as calibrated in-house prior to shipment and meet strict safety, quality and sustainability standards.

S+S REGELTECHNIK GMBH USA DIVISION LAS VEGAS, NV 89130
Phone: +1 725 264 4055 E-Mail: USA@SplusS.com

All information provided without prejudice, technical modifications and price changes reserved. Reprints, even excerpts, are only permitted with the approval of S + S Regeltechnik GmbH.
You can find technical data and further information in our web shop.

Order conveniently online: www.SplusS.com

References