ZENDURE AIO 2400 Solar Power Storage User Manual
- September 23, 2024
- ZENDURE
Table of Contents
AIO 2400
User Manual
AIO 2400 Solar Power Storage
Contact US/Claim the Product Warranty
If you have any questions or need to claim the product warranty, please scan
the QR code below to visit the Zendure help center and submit a ticket.
|
---|---
https://support.zendure.com/portal/de/signin|
https://support.zendure.com/portal/en/newticket?departmentId=846949000000006907&layoutId=846949000000074011
Return, Refund and Warranty Policy
Please scan the QR code below for always up-to-date information on the details
of the return, refund, and warranty policy for your product.
| |
---|---|---
https://zendure.de/pages/garantiebestimmungen| https://eu.zendure.com/pages
/warranty-policy| https://fr.zendure.com/pages/conditions-de-garantie
Disclaimer
Read all safety guidelines, warnings and other product information in this
manual carefully, and read any labels or stickers attached to the product
before using. Users take full responsibility for the safe usage and operation
of this product. Familiarize yourself with relevant regulations in your area.
You are solely responsible for being aware of all relevant regulations and
using Zendure products in a way that is compliant.
Keep this manual for future reference.
Safety Instructions
1.1 Usage
-
Read all up-to-date documents carefully before installing, using or servicing the product. Documentation is subject to change over time.
-
Please check whether AIO 2400 is damaged, cracked, leaking liquids, becoming hot, or exhibiting other abnormalities, and check any cables for damage before operating. If there are any problems, please stop using the product immediately and contact our customer service.
-
Do not place heavy objects on top of the AIO 2400.
-
Make sure all cords and plugs are intact and dry before connecting to avoid electric shock.
-
Do not install or operate the system under extreme climatic conditions such as lightning. snow, heavy rain, strong winds, etc.
-
To reduce the risk of injury, close supervision is necessary when the product is used near children.
-
Do not put fingers or hands into the product.
-
For safety purposes, please use only the original charger and cables designed for the equipment. We are not liable for damage caused by third party equipment, and this may render your warranty invalid.
-
Keep a distance of 50mm between AIO 2400 and other objects.
-
During the operation of the solar energy system, avoid direct sunlight to prevent the AIO 2400 from overheating. Do not place the AIO 2400 near any heat source.
-
Please install the product according to our user manual to avoid damage to the product or injury to other people.
-
Do not use this product near strong static electricity or strong magnetic fields.
-
Do not place the equipment in an environment with flammable or explosive compounds, gas, or smoke.
Since AIO 2400 relies on the shell to dissipate heat, exposing the enclosure to excessive heat will lead to damage. -
To reduce risk of damage to the electric cords and connectors, pull the connectors rather than the cord when disconnecting the product.
-
Do not use the product in excess of its output rating. Overloads may result in a risk of fire or injury to persons.
-
Do not use any products or accessories that are damaged or modified. Damaged or modified batteries may exhibit unpredictable behavior resulting in fire, explosion, or risk of injury.
-
Do not operate the product with a damaged cord or plug, or a damaged output cable.
-
Do not disassemble the product. Take it to a qualified service person when service or repair is required.
Incorrect reassembly may result in a risk of fire or electric shock. -
Do not expose the product to fire or high temperatures.
-
Do not attempt to replace the internal components of the equipment by any unauthorized personnel. Have servicing performed by a qualified repair person using only identical replacement parts. This will ensure that the safety of the product is maintained.
-
AIO 2400 has a protection level of IP65, so the product cannot be immersed in liquids. If the product accidentally falls into water during use, please place it in a safe and open area and stay away from it until it is completely dry. The dried product should not be used again and should be properly disposed of according to the disposal guidelines in this manual.
-
When charging a device, the product may feel warm. This is a normal operating condition and should not be a cause for concern.
-
To reduce the risk of electric shock, unplug the power pack from the outlet before attempting any instructed servicing.
-
When charging the internal battery, work in a well-ventilated area and do not restrict ventilation in any way, as inadequate ventilation may cause permanent damage to the equipment.
-
Ensure before finishing installation that the solar cable and Microinverter cable to home grid are disconnected.
-
Do not clean the product with harmful chemicals or detergents. Only clean the ports with a dry cloth.
-
Do not move or shake the unit while operating as vibrations and sudden impacts may lead to poor connections to the hardware inside.
-
Ensure that AIO 2400 and the Microinverter are installed securely to avoid accidents and product damage caused by falling.
-
In case of a fire, only a dry powder fire extinguisher is suitable for this product.
-
Servicing of batteries should be performed or supervised by personnel knowledgeable about batteries and the required precautions.
1.2 FCC STATEMENT
-
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1 ) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation. -
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE:
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator & your body.
1.3 EC DECLARATION OF CONFORMITY
ZENDURE TECHNOLOGY CO., LIMITED declares that the AIO 2400 product complies
with directive 2014/53/EU (RED), 2011/65/EU(RoHS), 2015/863/EU(RoHS).
The full text of the Declaration of Conformity is available at the following
web address: https://zendure.de/pages/download-center
| Declaration of conformity
The EU Declaration of Conformity can be requested at this address:
https://zendure.de/pages/download-center
---|---
| Disposal and Recycling
Disposal of packaging: dispose of the packaging separately by type of
material.
| Dispose of old equipment (applies in the European Union and other European
countries with separate collection (waste collection)) Old equipment must not
be disposed of in household waste. Every consumer is legally obliged to
dispose of old equipment that can no longer be used separately from household
waste, for example at a collection point for recyclables.
To ensure proper recycling and avoid negative impact on the environment,
electronic devices must be taken to a collection point in their community or
district. For this reason, electronic devices are marked with the symbol shown
here.
| Batteries and accumulators must not be disposed of in household waste. As a
consumer, you are legally obliged to dispose of all batteries and
accumulators, regardless of whether they contain pollutants or not, at a
designated collection point.
Marked with: Cd = Cadmium, Hg = Mercury, Pb = Lead. Return your product with
built-in battery only in a discharged state to your collection point.
Explanation of the Symbols
Symbol | Explanation |
---|---|
A high-risk hazard that, if not avoided, could result in death or serious |
injury.
| Important information that you must pay attention to.
| Part of a basic set
| Optional (not included)
| Indicates additional information on correct use or useful tips.
Important Tips
| The solar PV system is grid-tied. Please check if it is allowed in your
area. Depending on the region.
---|---
| AIO 2400 should be protected from direct sunlight to prevent rapid
temperature increase.
| Please check the required accessories before installation, as some
accessories need to be
purchased separately.
| After the installation, please first download the Zendure App to check
electricity produced and set the power to the Microinverter.
| After AIO 2400 installation, it will take about 5 minutes before it can be
connected to the grid, and the data will be synchronized to the Zendure App
within 20 minutes.
| Before setting the output to Microinverter, please confirm the rated power
of your Microinverter.
The output to Microinverter should not be greater than the rated power of your
Microinverter.
| Please turn off the device (press and hold the Power Button on AIO 2400 for
2 seconds)before removing.
What’s in the Box
Overview
5.1 System Overview
No.| Name| Description| Part of a basic set / Optional (not
included)
---|---|---|---
1| Solar Panel| One A10 2400 can connect with up to two sets of solar
modules.|
2| Solar Cable| For establishing the connection between A10 2400 and solar
panels.|
3| A10 2400| /|
4| Microinverter| Converts DC power into AC power and feeds it into the home
grid.|
5| Zendure Satellite Plug| Used to monitor device performance and communicate
wirelessly with A10 2400 to optimize energy usage.|
6| Zendure
Satellite Monitor CT| Prevents energy backflow into the public grid.|
Optional accessories are available for purchase on the official Zendure
website.
5.2 Product Overview
- Power Button
- IoT Button
- LED Light Strip
- MC4 PV Input 1
- MC4 PV Input 2
- Antenna
- Microinverter Output 1
- Microinverter Output 2
IoT Connection: After AIO 2400 is powered on, the LED Light Strip will start
to flash rapidly, and the device will automatically initiate the IoT
connection. Users can directly connect to IoT in the Zendure App.
Tips:
- After the device is bound to the Zendure App, when AIO 2400 is turned on again, the LED Light Strip light flashes slowly until it can communicate with the Zendure App.
- If you want to re-bind the account and reset the IoT connection, please press and hold the IoT button for 3 seconds to start the IoT connection.
- Turn On AIO 2400 System: Press and hold the power button 2 second to turn on AIO 2400.
- Turn Off AIO 2400 System: Press and hold the power button 2 seconds to turn off AIO 2400.
- AIO 2400 Hardware Reset: Press and hold the power button 10 seconds to reset AIO 2400.
5.3 Button Controls
Button | Action Press for 2 second | Function |
---|---|---|
Press for 2 seconds | Turn AIO 2400 on | |
Press once when powered on | Turn AIO 2400 off | |
Press for 10 seconds | Check current battery level | |
Press for 3 seconds | Reset AIO 2400 | |
Press for 3 seconds | Reset Internet connection |
5.4 Battery Level Display
Pattern| | | | |
---|---|---|---|---|---
Status| 100%| 75%| 50%| 25%| 5%
5.5 Button Controls
Color | Pattern | Status |
---|---|---|
Solid Green | Normal operation/Connected to the Internet | |
Blinking Green | Internet Connection in Progress | |
Pulsing Green | Built-in Battery Status | |
Blinking Red | An error has occurred. For more details, check the Zendure |
App.
Installing your AIO 2400 **
**
6.1 Pre-assembly
This user guide only describes the cable connection method and assembly of the
AIO 2400. To install the solar modules, please read the instructions for the
solar module and accessories.
If you want to check the function of the solar system, carry out the
installation on a sunny day.
Choose a location for the AIO 2400
Make sure the AIO 2400 is within the Wi-Fi coverage area. Do not place the AIO
2400 in an area where flammable or explosive materials are stored. The
protection class of the AIO 2400 is IP 65, so it can be used both indoors and
outdoors.
6.2 Confirming where to install your AIO 2400
Position your AIO 2400 on a hard, level floor.
Wear safety glasses and gloves when drilling holes.
Tool list
NO.| Picture| Name| Part of a basic set / Optional (not
included)
---|---|---|---
1| | Phillips Screwdriver|
2| | AIO 2400 Bracket Combination Set × 1|
3| | Machine screws M5*8 × 9|
STEP 1
Use three M58 machine screws to install the floor-standing L-shaped
[component] onto the floor stand.
STEP 2
Mount the AIO 2400 to the bottom bracket assembly.
STEP 3
Based on your Microinverter, select the appropriate height and then use six
M58 machine screws to install the U-shaped bracket onto the back of the AIO
2400.
6.3 Connecting Cables
If you connect multiple solar panels as a group in series or parallel, make
sure that the maximum operating voltage (Vm) and maximum operating current
(Im) of each group do not exceed the maximum input voltage (60V) nor the
maximum output current (MPPT1 14A, MPPT2 20A). Do not exceed the PV input of
the AIO 2400.
The maximum operating voltage (Vm) and the maximum operating current (Im) of
solar modules must be uniform.
Before connecting cables, ensure that the Microinverter, solar panels, and the
home grid are disconnected and AIO 2400 is turned off.
Single AIO 2400
Installation list
NO.| Picture| Name| Part of a basic set / Optional (not
included)
---|---|---|---
1| | AIO 2400×1|
2| | Microinverter×1|
3| | BKW-AC Cable×1 (*The plug varies by region.)|
4| | Solar Panel|
5| | Solar Panel Extension Cable|
6| | Solar Panel Parallel Cable|
- Adjust the height of the elevation bracket at the back of the AIO 2400 to the appropriate level, then mount the Microinverter on the back of the AIO 2400.
- Connect the PV Input cable from the Microinverter to the Microinverter Output interface of the AIO 2400.
- Use the original BKW-AC Cable to connect the Microinverter to a household outlet.
- Connect one 400W solar panel to the PV Input 1 interface of the AIO 2400 using a solar panel extension cable.
1)Connect two 400W solar panels together using a solar panel parallel connection cable.
2)Connect the two parallel-connected 400W solar panels to the PV Input 2 interface of the AIO 2400 using a solar panel extension cable. 400W
Cascaded AIO 2400
Installation list
NO.| Picture| Name| Part of a basic set / Optional (not
included)
---|---|---|---
1| | AIO 2400×1|
2| | AIO 2400×1|
3| | Microinverter×1|
4| | BKW-AC Cable×1
(*The plug varies by region.)|
5| | Solar Panel|
6| | Solar Panel Extension Cable|
7| | Solar Panel Parallel Cable|
- Install the Microinverter on the back of the first AIO 2400 unit.
- Connect the PV Input cables of the Microinverter to the Microinverter Output interfaces of both AIO 2400 units, one after the other.
- Use the original BKW-AC Cable to connect the Microinverter to a household outlet.
- Connect one 400W solar panel to the PV Input 1 interface of each AIO 2400 unit.
- Connect two 400W solar panels together using a solar panel parallel connection cable.
- Connect the parallel-connected 400W solar panels to the PV Input 2 interface of each AIO 2400 unit.
6.4 Installation Method for the Top Cover
NO.| Picture| Name| Part of a basic set / Optional (not
included)
---|---|---|---
1| | AIO 2400×1|
2| | Phillips Screwdriver|
3| | Top Cover × 1|
4| | Top Cover Screws M3*10 × 5|
Once you have confirmed that the Microinverter is installed at a height on the back of the AIO 2400 that does not exceed the top of the AIO 2400, you can proceed to install the Top Cover onto the AIO 2400.
6.5 Specifications
Capacity | 2,400Wh |
---|---|
Battery Type | LiFePO ₄ |
Wireless Type | Bluetooth, Wi-Fi |
PV Input Port | MC4 |
PV Input Voltage Range | 16V to 60V |
PV Input 1 Power | 400W |
PV Input 1 Current | 14A |
PV Input 2 Power | 800W |
PV Input 2 Current | 20A |
Microinverter Output Port | MC4 |
Microinverter Output Voltage Range | 16V to 60V |
Microinverter Output 1 Power | 1,200W Max |
Microinverter Output 1 Current | 30A |
Microinverter Output 2 Power | 1,200W Max |
Microinverter Output 2 Current | 30A |
Microinverter Output 1 + Output 2 Power | Total 1,200W Max |
Charging temperature | 0℃ to 55℃ |
Discharging temperature | -20℃ to 60℃ |
Dimensions | 657x427x150 mm |
Weight | 27.8kg (Excluding brackets) |
Waterproof rating | IP65 |
6.6 Download the Zendure App
Images are for reference only. Please refer to the actual user interface of
the app.
The Zendure App gives users the ability to allocate the power to AIO 2400’s
built-in battery and home grid and monitor power generation. The power to the
Microinverter can be set in a range of 30W to 1,200W.
Read the Zendure App user guide and access the download link here:
https://zendure.com/pages/download-center.
https://app.zendure.com/download
Privacy Policy
By using Zendure Products, Applications and Services, you consent to the
Zendure Terms of Use and Privacy Policy, which you can access via the “About”
section of the “User” page in the Zendure App.
Add device and update to the latest firmware version Using the device for the
first time, you need to update the firmware via the Zendure App. More
information is in the Zendure App user guide.
Set the power to the Microinverter
The maximum solar input power of the AIO 2400 system is 1,200W. You can set
the output power to the Microinverter, while excess power will flow to the
built-in battery.
For example: If the total solar input is 1,200W and you set the output to
800W, the remaining 400W will go to the built-in battery.
Tips:
It takes a period of time for the system to connect to the grid, and it takes
about 20 minutes to synchronize data with Zendure App. After the installation,
please wait 20 minutes before going to the app settings.
- We recommend prioritizing charging the battery during the day, only allocating enough output power for the Microinverter to cover your basic power consumption.
There are a few ways to determine how much energy you’ll need to store for the night:
- Add together the power consumption of major appliances and other devices that draw significant power or energy.
- Go to the meter box right before you go to bed, write down your current meter reading and the time. As soon as you get up, write down the meter reading and the time. You can calculate your base load from consumption and elapsed time.
- You can use a measuring device that you plug between the socket and the power consumer. To calculate the base load, collect the wattage consumed from all the devices that are constantly running (including standby) and add up the values.
6.7 Disconnection of AIO 2400
Press and hold the power button on the AIO 2400 for 2 seconds to power it off.
Disconnect from the home grid by unplugging the Microinverter and home Schuko
cables.
Disconnect the solar panels by unplugging the cables from the two sets of
solar panels and AIO 2400.
Disconnect the Microinverter by unplugging the cables from the Microinverter
and AIO 2400.
Finally, remove the Microinverter from the back of the AIO 2400.
https://zendure.com
Zendure USA Inc.
ZENDURE TECHNOLOGY CO., LIMITED
Hours: Mon – Fri 9:00 – 17:00 PST
Phone: 001-800-991-6148 (US)
0049-800-627-3067 (DE)
Support / Contact:
https://zendure.de/pages/contact
https://eu.zendure.com/pages/contact-us
https://zendure.com/pages/contact
Website:
https://zendure.de
https://eu.zendure.com
https://zendure.com ZENDURE TECHNOLOGY CO., LIMITED.
© 2024 Zendure USA Inc.All Rights Reserved.
Printed on recycled materials. Made in China
EU Importer: Zendure DE GmbH
Address: Rheinallee 1,40549 Düsseldorf
E-mail: sales@zendure.com
Phone: 0049-800-627-3067
References
- Contact Customer Service – Zendure – Zendure EU
- Zendure - SuperCharged | Zendure
- Contact Us – Zendure
- Zendure Deutschland | SuperCharged
- Zendure Deutschland | SuperCharged
- Kontaktieren Sie den Kundendienst – Zendure
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>