Zendure V6400 Super Base Power Station With 400 Watt Soalr Panel User Manual
- May 15, 2024
- ZENDURE
Table of Contents
Zendure V6400 Super Base Power Station With 400 Watt Soalr
DISCLAIMER
Read all safety guidelines, warnings and other product information in this
manual carefully, and read any labels or stickers attached to the product
before using. Users take full responsibility for the safe usage and operation
of this product. Familiarize yourself with relevant regulations in your area.
You are solely responsible for being aware of all relevant regulations and
using Zendure products in a way that is compliant.
Keep this manual for future reference.
Before You Begin
The information contained herein is subject to change without notice. For the latest version, please visit https://zendure.com/pages/download-center.
Specifications
- Zen 126W AC refers Output to the support combined either 240V maximum or 120V output output power at a of lime. the Car Outlet and the DC5521
- ports Total USB-C together. Output 200W Mox.
- The temperature mentioned above is ambient temperature.
Safety Guidelines
-
Store product in a cool and dry place.
-
Do not dispose of the product in heat or fire.
-
Do not expose to moisture or submerge it in liquid.
-
Do not use around strong static electricity or magnetic fields.
-
Do not disassemble the product. Consult official Zendure channels whenservice or repair is required. Incorrect disassembly or reassembly may result in a risk of fire or injury to persons.
-
When using the product, please strictly follow the operating environment temperature range specified in the user manual. If the temperature is too high, it may result in a fire or explosion; if the temperature is too low, the product performance may be severely reduced, or the product may cease to work.
-
Do not block or obstruct the fan during use or place the product in an unventilated or dusty area.
-
Ensure the product is not hit, dropped, or heavily vibrated. Securely fasten the product when transporting to avoid damage. If severely damaged, turn off the power source immediately and discontinue using the product.
-
If you accidentally drop the product into water during use, please place it in a safe open area, and stay away from it until it is completely dry. The dried product should not be used again and should be properly
disposed of according to the Disposal Guide section of this manual. -
Only clean the ports with a dry cloth.
-
Place on a flat surface to keep the product from falling over. If the product is overturned and severely damaged, turn it off immediately, place the battery in an open area, keep it away from people and combustibles, and dispose of it in accordance with local laws and regulations.
-
Keep out of reach of children and pets.
Disposal Guide
- When possible, fully discharge the battery before disposing of it. Consult your local laws on battery recycling and disposal.
- If the battery cannot be fully discharged due to product failure, contact a professional battery recycling company for further processing.
- When disposing of secondary cells or batteries, keep cells or batteries ofdifferent electrochemical systems separate from each other.
Important Tips
It is recommended to use this product in an environment of 15°C~35°C, away
from water, fire and other sharp objects.
For long-term storage, please charge and discharge this product once every 3
months. That is, discharge the product to 30% first, and then recharge it to
60%.
For safety reasons, do not store this product in an environment above 45°C or
below 0°C for a long time.
If the power of this product is lower than 1% after use, please charge it to
60% before storing it. Because the battery is left idle for a long time when
the power is seriously insufficient, it will cause irreversible damage to the
battery and shorten the service life of the product.
Do not disassemble the product. When service or repair is required, please
consult official Zendure channels. Improper disassembly or reassembly may
result in a risk of fire or personal injury.
Getting Started
What’s in the Box
Product Overview
Display
Operation Guideline
- When there Is AC or ZenCharge recharging, RV Mode wlll exit (Zen AC Output RV Icon off).
Connect with Satellite Battery
SuperBase V can be connected to Satellite Battery for capacity expansion. A
Battery Cable* (not included} is needed. One SuperBase V can connect with max
4 Satellite Battery units. It’s recommended stacking ONLY one Satellite
Battery on top in case crushed.
Refer to the user manual of the Satellite Battery for detailed instructions.
Tips
-
It’s recommended that both SuperBase V and Satellite Battery are turned off before connection.
-
The Satellite Battery icon will show up on display after connection; then you can start charging or discharging.
-
Do not connect the SuperBase V to the battery during charging/discharging process.
-
Do not touch the metal pins of the ports by hands or other objects. Gently clean them with a dry cloth when necessary.
-
Tightly connect the Battery Cable with SuperBase V and Satellite Battery. Failing to comply may heat the connection and affect the device’s performance or lead to a fire.
-
The Battery Cable has 2 different ports at each end.
Connect with Home Panel
ZENDURE Home Panel with EV Outlets (referred to as Home Panel} is a smart load
side transfer switch. It’s also a fast-charging dock for SuperBase V and
features two EV outlets. A Home Panel can be connected to one or two SuperBase
Vunlts’ ZenT2 Port.
Refer to the user manual of the Home Panel for detailed instructions. Press AC
Power Button for 3 seconds to connect with Home Panel. Refer to the latest
Zendure App for more information.
Tips:
- It’s recommended that both SuperBase V(s) and Home Panel are turned off before connection.
- The Home Panel icon will show up on disploy ofter connection; then you can start charging or discharging.
- Do not connect them during charging/discharging process.
- Do not touch the metal pins of the ports by hands or other objects.Gently clean them with a dry cloth when necessary.
Connect with ZenY Cable
ZenY Coble* can connect two SuperBase V units together for higher output up to
7200W. Then it can connect to a L14-30p power inlet for a regular transfer
switch. It’s a solution to replace fuel generators. Refer to the user manual
of the ZenY Cable for detailed instructions.
Recharging
AC Recharging
Zendure’s GridFlow 2.0 Real-Time Bidirectional Inverting Technology is
specifically for AC recharging, offering or 1800W@120VAC or 3600W @240VAC of
maximum input power. In case of unusual situations where the AC input current
remains higher than 20A, the AC Input port will initiate a self-protection
function, and the Overload Switch on the product will automatically pop up.
After confirming that there is no product failure, you can press the Overload
SWitch to resume charging.
You can control the charging power through the AC Charge Speed Switch. The default Slaw AC Charge is 400W, which can be modified in the Zendure app.
Tips
-
Please use the AC Charging Cable* in the box. Plug directly into an AC wall outlet and make sure that the wall outlet and circuit are rated for more than 15A. Otherwise, reduce the unit charging speed via the Zendure App. Zendure assumes no responsibility for any consequences of product misuse, including but not limited to charging with an unsuitable wall outlet, circuit, or power cable.
-
The default AC Charging Cable is for 120VAC. You can purchase a third-party 240VAC AC charging cable higher than 15A rated current with qualified certifications.
Solar Recharging
Users can connect solar panels as shown in the figure to recharge the product.
The product supports 12-150VDC* input, 25A max current, and 3000W max charging
power.
Wire max 3 solar panels in series
Wire max 3 series group solar panels in parallel Tips
- When using Zendure 200W or 400W Solar Panels (sold separately) to charge the product, please follow the instructions that come with the solar panels.
- Before connecting a solar panel, please ensure that the solar panel’s output voltage is within 150Voc to avoid damaging the product.
MPPT Voltage Range is 12-120VDC, Open Circuit Voltage is 150VDC.
MC4 parallel cable is not included.
Car Recharging
Users con recharge the product through the car cigarette lighter socket. This
product supports 12V/24V car chargers with a 10A default charging current.
Please recharge using the car charger only while the car’s engine is running,
to ovoid draining your car’s battery. In addition, please make sure that the
cigarette lighter port of the Car Outlet and the Car Charging Cable are in
good condition. Zendure assumes no responsibility for any loss, damage, or
injuries caused by misuse.
ZenCharge Recharging
Zendure’s ZenCharge Technology is specifically for ZenT2 Port recharging from
a level 1 or level 2 EV charging station, offering or 1800W @120VAC or 3600W
@240VAC of maximum input power.
EV Tl Adapter is required for use in the North America.
Duel Rechorging
Solar recharging or Car recharging can work together with AC recharging or
ZenCharge recharging. Combining solar and AC or ZenCharge power, SuperBase V
can be recharged up to 5150W on its own, or 6600W when connected to a
Satelllte Battery.
AmpUp, Seamless UPS, Motorized Wheels
AmpUp
With Zendure AmpUp technology, the product can power a 5000W max device while
the rated output power remains 3800W, avoiding operation fallure due to
overload protection.
Tips
- AmpUp is not available when the AC output is turned on in a recharging state (in bypass mode).
- AmpUp is not applicable for all electrical appliances; it’s incompatible with appliances that have strict voltage requirements and a rated power over 3800W. Appliances with voltage protection (such as precise Instruments) are not
- supported.
- AmpUp is more suitable for heating devices. When using AmpUp with an untested device, please monitor its performance for any irregularities.
Seamless UPS
This product supports seamless UPS (Uninterruptible Power Supply}. When you
connect the grid power to the AC Input Part of the product through an AC
cable, you can power electrical devices through the AC Output Ports (AC power
will come from the grid and not the power station in this situation). The UPS
Ready icon will show up on display after connection. In case of a sudden
blackout, the product can automatically switch to the battery-powered supply
mode within 13ms, among which the 2 NEMA 5-20 outlets ot the bottom of the US
version can achieve Oms switching time. Please test and confirm compatibility
before using the product as a UPS. We recommend that you only charge one
device at a time and avoid using multiple devices simultaneously to avoid
triggering overload protection. Zendure assumes no responsibility for any
device failures or data losses caused by misuse of this product.
Motorized Wheels
SuperBase V’s rear wheels are motorized to help lighten the load. Pull the
handle and move it even on inclined surfaces.
Press and hold DC Power Button for 3 seconds to turn ON {or OFF) Motorized
mode, then you can trigger the motorized wheels by pulling them rotating for 3
seconds. The default speed is 1.8mph or 3km/h, which can be modified via
Zendure App. You can stop the motorized output by blocklng It for 3 seconds.
Once your turn on AC or DC outputs or there is any recharging, it will turn
OFF Motorized mode {icon flashes) in case any accidents.
Tips
- Keep out of reach of children and pets.
- No more than 10 degree slope is recommended. Zendure assumes no responsibility for any accidents by misuse of the motorized wheels.
Firmware Up date, Voice Control
Firmware Update
When using It for the first time, please check and update to the latest
firmware. Zendure App supports over-the-air (OTA) update.
Voice Control
SuperBase Vis easy to integrate with your existing Google or Alexa voice
assistant. Just say the word for hands-free status and controls.
Read the Zendure App user guide and access the download link here:
https://zendure.com/pages/download-center
Privacy Policy By using Zendure Products, Applications and Services, you consent to the Zendure Terms of Use and Privacy Policy, which you can access via the “About” section of the “User” page in the Zendure App
Tips
- Do Not turn off the device during the firmware updating.
- Please update the firmware when the capacity is more than 20%, in order to have enough power to complete the update.
FAQs
-
Q: Can SuperBase V6400 (or V4600) connect with Satellite Battery B4600 (or 86400)?
A: No, it can’t, as they are different battery types. -
Q: How many Satelllte batteries can be connected to a slngle SuperBose V?
A: For each SuperBase V. you can connect up to 4 Satellite Battery units. Q: Con I run a 240V device on the US version?
A: Yes, SuperBase V has dual voltage feature can handle both 120V&240V AC output within 3800W. -
Q: Can SuperBase v be charged with solar panels from a different brand?
A: Yes, SuperBase V can be charged by other solar panels with voltage ranging from 12V to 150V; Zendure’s 200W and 400W Solar Panel has been thoroughly tested and remain our recommendation. -
Q: How to store SuperBase V?
A: For long-term storage, please charge and discharge this product once every 3 months. That is, discharge the product to 30% first, and then recharge it to 60%.
Troubleshooting
FCC Caution
FCC STATEMENT
- This device complies with Part 15 of the FCC Rules. Operation is subject to the followlng two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
- any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE:
This equipment ho5 been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation.
This equipment generates uses and can radiate radio frequency energy and, If
not installed and used in accordance with the instructions, may cause harmful
interference to radio communications.
However, there Is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator & your body.
Phone: 800-219-0960 (US)
Office Hours: Mon – Fri 9:00 – 17:00 PST
Support/ Contact: www.zendure.com/support
Website: www.zendure.com
® end Cl 2022 Zendure USA Inc:. All Rights Reserved.
Printed on recycled meteriels. MA.OE IN CHINA
Read User Manual Online (PDF format)