Specifications

  • Model: L3, L4
  • Height: 560mm
  • Width: 920mm (L3), 1310mm (L4)
  • Depth: 620mm
  • Weight: 30.0kg (L3), 40.0kg (L4)

Product Usage Instructions

Installation and Commissioning

  1. This appliance must be earthed.
  2. An equipotential bonding terminal is provided for cross bonding with other equipment.
  3. If replacing the plug, connect the terminals as follows:
    • Green and Yellow wire – Earth (E)
    • Blue wire – Neutral (N)
    • Brown wire – Live (L)
  4. Ensure ample room ventilation with no cross draughts (7-10 air changes per hour).
  5. Install the filtration appliance on a suitable wall, leaving an air space above it and ensuring the lower edge of the canopy is 800mm above the cooking surface. The front edge should overlap the cooking area by 100mm.
  6. Using the relevant dimensions provided, drill holes and insert rawlplugs. Hang the appliance onto screws in keyhole cut-outs and secure into place by screwing through the top row of holes. Replacethe filters.

Operating Instructions

  • Read all instructions carefully before use.
  • Avoid accidental contact with hot parts during operation.
  • Disconnect the appliance before servicing, maintenance, or cleaning.

Cleaning
Clean the appliance before initial use and regularly thereafter according to the provided instructions in the manual.

Servicing, Maintenance, and Component Replacement
Refer to the manual for information on servicing, maintenance, and replacing components. Only qualified personnel should perform these tasks.

Fault Finding
If you encounter any issues with the product, refer to the fault finding section in the manual for troubleshooting steps or contact customer support.

FAQ

  • Q: What should I do if the supply cord is damaged?
    A: If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or a similarly qualified person.

  • Q: How often should I clean the appliance?
    A: Clean the appliance before initial use and regularly thereafter to maintain optimal performance.

Installation, Operating and Servicing Instructions

Electric Fume Filtration Units
L3, L4

Please make a note of your product details for future use:

  • Date Purchased:_____
  • Model Number:__
  • Serial Number:__
  • Dealer:_ ___

IMPORTANT INFORMATION

Read these instructions carefully before using this product, paying particular attention to all sections that carry warning symbols, caution symbols and notices. Ensure that these are understood at all times.

WARNING!
This symbol is used whenever there is a risk of personal injury.

CAUTION!
This symbol is used whenever there is a risk of damaging your Lincat product.

NOTE:
This symbol is used to provide additional information, hints and tips.

KEEP THIS MANUAL FOR FUTURE REFERENCE

WARNINGS AND PRECAUTIONS

  • This appliance must be installed, commissioned and serviced by a qualified person in accordance with national and local regulations in force in the country of installation.
  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified person.
  • Ensure that the plug/socket is accessible at all times.
  • Strip plastic coating and clean the appliance before use.
  • During operation parts may become hot – avoid accidental contact.
  • Disconnect this appliance before servicing, maintenance or cleaning.

TECHNICAL DATA

Model| Height (mm)| Width (mm)| Depth (mm)| Weight (kg)
---|---|---|---|---
L3| 560| 920| 620| 30.0
L4| 560| 1310| 620| 40.0

CHECK LIST OF ENCLOSURES

Warranty card

Instructions manual
Aluminium filters (L3 x 2, L4 x 3)
Carbon filters (L3 x 2, L4 x 3)
Fixing kit

INSTALLATION AND COMMISSIONING

This appliance must be earthed.
An equipotential bonding terminal is provided to allow cross bonding with other equipment.

If replacing the plug connect the terminals as follows:

  • Green and Yellow wire Earth E
  • Blue wire Neutral N
  • Brown wire Live L

Supply cords shall be oil resistant, sheathed flexible cable not lighter than ordinary polychloroprene or equivalent elastomer sheathed cord (code 60245 IEC 57)
Unlatch the front flap and slide out the filters.
Ensure ample room ventilation with no cross draughts (7-10 air changes per hour).
Install the filtration appliance on a suitable wall, so that there is an air space above it and the lower edge of the canopy is 800mm above the cooking surface. The front edge should overlap the cooking area by 100mm.
Using the relevant dimensions from Fig 1, drill holes with a No.4 masonry drill and insert rawlplugs. Hang the appliance onto screws in the keyhole cut- outs and secure into place by screwing through the top row of holes. Replace the filters.

Power Ratings

Model kW Amps
L3 0.35 1.5
L4 0.45 2.0

OPERATING INSTRUCTIONS

Only qualified or trained personnel should use this appliance.
Connect the appliance to the electricity supply. Turn on the power switch Fig 2 (A).
To use the lights, operate switch (B).

This appliance is fitted with a safety thermostat to cut off the power in the event of a fault. To re-set the safety thermostat, press the button as located in Fig 2, E.

CLEANING

  • Do not use a water jet or steam cleaner, and do not immerse this appliance.
  • Clean all panels with warm water and mild detergent, do not use abrasive materials. Dry with a soft cloth.
  • Avoid damaging the thermostat capillary during cleaning.

SERVICING, MAINTENANCE AND COMPONENT REPLACEMENT

Lamp bulb
Disconnect the appliance. Carefully prise glass cover off with a flat bladed screwdriver.
Replace bulb and re-fit glass cover.

Filters
Disconnect the appliance. Release the latches – Fig 2 (C) and open the door (D). Slide filters out and replace. Close and secure door.
All other servicing, maintenance and component replacement on this appliance should be carried out by one of our recommended service engineers.

FAULT FINDING
Please refer to the Service Help Desk number on the final page of this manual.

SPARE PARTS LIST

Part Number Description Used on
FA25 Fan ****



L3, L4

FI11| Aluminium filter
FI13| Charcoal filter
FI15| Foam filter pad
LA10| Light
PL201| Plug and lead
SU15| Latch
SW69| On/Off switch
SW70| Light switch
TH73| Thermostat

SERVICE INFORMATION

For help with the installation, maintenance and use of your Lincat equipment, please contact our service department:

UK: 01522 875520
For non-UK customers, please contact your local Lincat dealer

All service work, other than routine cleaning should be carried out by one of our authorised service agents. We cannot accept responsibility for work carried out by other persons.
To ensure your service enquiry is handled as efficiently as possible, please tell us:

  • Brief details of the prob lem

Lincat reserve the right to carry out any work under warranty, given reasonable access to the appliance, during normal working hours, Monday to Friday, 08:30 to 17:00.

GUARANTEE
This unit carries a comprehensive UK mainland 2 year warranty. The guarantee is in addition to, and does not diminish your statutory or legal rights.
The guarantee does not cover:

  • Accidental damage, misuse or use not in accordance with the manufacturer’s instructions
  • Consumable items (such as filters, glass, bulbs, slot toaster elements and door seals.)
  • Damage due to incorrect installation, modification, unauthorised service work or damage due to scale, food debris build-up, etc.

The manufacturer disclaims any liability for incidental, or consequential damages. Attendance is based on reasonable access to the appliance to allow the authorised technician to carry out the warranty work.
Service calls to equipment under warranty will be carried out in accordance with the conditions of sale. Unless otherwise specified, a maximum of 15 minutes of administrative time, not spent directly carrying out servicing work, is provided for within the warranty. Any requirement for staff attending the call to spend greater time than 15 minutes due to administrative requirements, such as on health and safety risk assessments, will be chargeable at the prevailing rate.