Lincat EB3FX Water Boiler and Chiller Instruction Manual
- June 6, 2024
- Lincat
Table of Contents
- IMPORTANT INFORMATION
- WARNINGS AND PRECAUTIONS
- TECHNICAL DATA
- CHECK LIST OF ENCLOSURES
- INSTALLATION AND COMMISSIONING
- OPERATING INSTRUCTIONS
- SPARES LIST
- CLEANING
- DESCALING
- SERVICING, MAINTENANCE AND COMPONENT REPLACEMENT
- FAULT FINDING
- PARE PARTS LIST
- CCESSORIES
- SERVICE INFORMATION
- Documents / Resources
Installation, Operating and Servicing Instructions
Water boiler and chiller –
EB3FX/HC/PB
Please make a note of your product details for future use:
Date Purchased:
Model Number:__
Serial Number:__
Dealer:____
IMPORTANT INFORMATION
Read these instructions carefully before using this product, paying particular attention to all sections that carry warning symbols, caution symbols and notices. Ensure that these are understood at all times.
WARNING!
This symbol is used whenever there is a risk of personal injury.
CAUTION!
This symbol is used whenever there is a risk of damaging your Lincat product.
NOTE:
This symbol is used to provide additional information, hints and tips.
KEEP THIS MANUAL FOR FUTURE REFERENCE
WARNINGS AND PRECAUTIONS
This appliance must be installed, commissioned and serviced by a qualified person with the installation instructions for the appliance and in accordance with national and local regulations in force in the country of installation.
This appliance is intended for indoor use only and should never be installed outdoors or exposed to the elements of nature. This unit must not be positioned in an area that may be cleaned by a water jet and must not be cleaned by water jet.
The unit should be stood on a solid counter or shelf. Ensure that there is adequate ventilation around the unit. In particular ensure that top and base are clear from obstruction and ensure minimum of 50mm gap around the unit.
Do not install this unit close to any source of heat, which may result in
operating condition exceeding its design limits.
Ambient temperature range: minimum 16° C, maximum 32° C, Maximum relative
humidity 70%.
Switching on: If the unit has been laying on it’s side then allow at least 3
hours in upright position before switching on.
If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified person.
Ensure that the plug/socket is accessible at all times.
Strip plastic coating and clean the appliance before use.
This appliance contains R134a refrigerant under pressure. No part of unit
should be exposed to a naked flame. Maintenance of the refrigeration unit must
be carried out
by an accredited service provider or qualified refrigeration engineer.
During operation parts may become hot – avoid accidental contact.
Always disconnect this appliance before servicing, maintenance or cleaning.
This appliance must be earthed.
Keep these instructions in safe place near the unit for future reference.
TECHNICAL DATA
Height (mm) | 596 |
---|---|
Width (mm) | 250 |
Depth (mm) | 570 |
Weight (kg) | 32 |
Power rating(kW) | 3 |
Current rating (A) | 13 |
CHECK LIST OF ENCLOSURES
Warranty card
Instructions manual
Drip tray
Connection hose
Silicone drain hose assembly
INSTALLATION AND COMMISSIONING
This appliance must be earthed.
If replacing the plug connect the terminals as follows:
If replacing the plug connect the terminals as
Green and Yellow wire
Green and Yellow wire | Earth | E |
---|---|---|
Bluewire | Neutral | N |
Brown wire | Live | L |
Install this appliance on a level surface ensuring all vents are unobstructed.
Only install this unit in locations where it can be overseen by trained
personnel.
Inlet water pressure should be between 2 and 6 bar. (0.2MPa to 0.6MPa)
If water pressure exceeds 6bar fit a suitable pressure reduction valve.
Ambient air temperature shall be between 16° and 32°C
Electrical supply
The unit is supplied with a 13 amp plug to BS1363.
Water supply connection
Connect the supplied water inlet hose to the inlet connection point on the
filter head and the other end to the mains supply via an accessible isolating
tap with a ¾” BSP thread.
Use the hose set supplied with the appliance – any previous hose set is not to
be reused.
Potable water. If solid particles are known to be in the supply, add an extra
inline filter or strainer.
OPERATING INSTRUCTIONS
General arrangement
1 | Lid | 8 | Hot tank drain valve |
---|---|---|---|
2 | Touchscreen display | 9 | Drain pipe – thermal trip reset |
3 | Dispense button cold | 10 | Pressure reducing valve |
4 | Dispense spout cold | 11 | Water inlet point |
5 | Dispense button hot | 12 | Side condenser air vent |
6 | Dispense spout hot | 13 | Mains power inlet |
7 | Serial plate location | 14 | Drip tray |
Only qualified or trained personnel should use this appliance.
First Use
Switch on the electricity supplies and leave the boiler to fill for 30 minutes. There is a delay of 2 minutes for the chiller to come ‘ON’, this will happen every time when electricity is interrupted.
The unit will display ‘Wait’ whilst it fills and heats/cool. It will display
‘Ready’ when water can be drawn off.
Touchscreen display configuration
KEY | Icon | Pressing allows |
---|---|---|
1 | Power button | On, off, Timed and ECO modes |
2 | Timed operation | Access to timer settings |
3 | Clock | Access to clock |
4 | Hot status | Status screen |
5 | Cold status | Status screen |
6 | Status | Cold-ready to use/wait |
7 | Status | Hot-ready to use/wait |
8 | Chiller module | Power to chiller module |
9 | Water in | Hot tank water filling |
10 | Fault | F03- Power board error |
F04- Power board over temperature
F05- Power board fault
F06-Sensor fault
F07-Heating fault
F08-Thermistor fault
F09-Water supply fault
F10-Chiller condenser over heat
F11-Chiller- clean condenser
11| Element| Element ON
12| Filter| Filter life status
When the boiler is supplied timed mode and clock function are all turned off.
To select these options press the “Power button”, select the feature required
and follow the on-screen instructions.
To adjust the temperature, clock or to perform a boiler descale press “Ready”,
select the option and follow the on-screen instructions.
All units are fitted with a settings PIN lock. Press Ready and then Settings
to access the PIN setting screen. Master PIN code is available from Lincat
Service should you
forget the user set PIN.
Filter Replacement
The filter display shows the estimated life remaining in the filter cartridge.
A reminder message is displayed when the filter needs changing.
To replace the filter:
Twist the base of the filter (E) 90 degrees to the left and lower the
cartridge out of the appliance. It will contain a small amount of water. Only
use a genuine Lincat Filter.
Insert the new filter into the recess and lock in place by twisting to the
right.
Press the “Filter life icon” and follow the on-screen instructions to reset
the filter life.
Drain off approximately 5 litres of water to remove any loose carbon particles
from the filter.
The boiler will not fill if the filter is removed as the filter head
incorporates a shut-off valve.
F10-Chiller condenser over heat: This could be due to condenser fan not
working, condenser air outlet blocked or condenser blocked.
F11-Chiller- clean condenser: This is a regular periodic warning to ensure the
condenser fins are not blocked that should be kept clean to ensure optimum
operation of cooler water cooling system.
SPARES LIST
Part number | Description |
---|---|
PR111 | Control/Display board |
PR101 | Auxiliary power board |
PR100 | Power board |
TH88 | Tank over heat cut out |
TH123 | Steam/over flow over heat cut out |
TH124 | Hot tank thermistor |
TH126 | Cold block thermistor |
WL13 | Level sensor cable |
CA179 | Interconnect data cable |
CA207 | Condenser signal cable |
EBCM01 | Chiller module |
CLEANING
Do not use a water jet or steam cleaner, and do not immerse this appliance.
Clean all panels with warm water and mild detergent and do not use abrasive
materials. Dry with a soft cloth.
Slide out and empty the drip tray regularly, and wipe the dispensing tap
spouts daily to remove limescale deposits.
DESCALING
De-scaling is an important maintenance task and must be performed to maintain
the warranty. Failure to descale a unit may result in the boiler overfilling
and leaking from
the overflow.
Lincat offer a purpose designed de-scaler powder, part number DP10 that can be
used should you require it.
SERVICING, MAINTENANCE AND COMPONENT REPLACEMENT
ll maintenance and component replacement on this appliance should be carried out by one of our recommended service engineers.
FAULT FINDING
Please refer to the Service Help Desk number on the final page of this manual.
PARE PARTS LIST
For spare parts for your water boiler/chiller please contact the Lincat Spares department on 01522-875510. Refer to the serial plate for the model and serial number of your water boiler, as this will help us quickly identify the part you require.
CCESSORIES
Part Number | Description |
---|---|
BR57 | Wall bracket |
DP10 | Descaler powder |
SERVICE INFORMATION
For help with the installation, maintenance and use of your Lincat equipment, please contact our service department:
UK: 01522 875520
For non-UK customers, please contact your local Lincat dealer
All service work, other than routine cleaning should be carried out by one of our authorised service agents. We cannot accept responsibility for work carried out by other persons.
To ensure your service enquiry is handled as efficiently as possible, please tell us:
Lincat reserve the right to carry out any work under warranty, given reasonable access to the appliance, during normal working hours, Monday to Friday, 08:30 to17:00.
GUARANTEE
This unit carries a comprehensive UK mainland 2 year warranty.
This requires you maintain and care for your product and follow maintenance instructions. If you fail to maintain your unit or damage components Lincat may charge you for a warranty repair.
The guarantee is in addition to, and does not diminish your statutory or legal
rights.
The guarantee does not cover:
- Accidental damage, misuse or use not in accordance with the manufacturer’s instructions
- Consumable items (such as filters, glass, bulbs, slot toaster elements and door seals.)
- Damage due to incorrect installation, modification, unauthorised service work or damage due to scale, food debris build-up, etc.
The manufacturer disclaims any liability for incidental, or consequential damages. Attendance is based on reasonable access to the appliance to allow the authorised technician to carry out the warranty work.
This page intentionally blank
Documents / Resources
|
Lincat EB3FX Water Boiler and
Chiller
[pdf] Instruction Manual
EB3FX, Water Boiler and Chiller
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>