Section 1: General Information

Before proceeding with the installation, read the manual
completely. This manual provides installation instructions for the
VersaFlo Integrated Bypass Accessory Kit for the JXi & JXiQ
pool and spa gas heater product line.

Section 2: Overview

2.1 JXIVFKIT: VersaFlo Integrated Bypass Kit

Before starting the installation, ensure you have all the parts
listed in the package contents. If any parts are missing or
incorrect, contact your local distributor or Zodiac Pool Systems
LLC technical support for assistance.

2.2 Efficiency

When the flow gate is in the bypass position, and water is
bypassing the heat exchanger, head loss through the heater is
significantly reduced. To maximize energy savings, combine with an
automation system and a variable speed filtration pump to reduce
pump speed while flow is bypassing the heater.

Section 3: Electrical Connections

Follow the steps to open the heater, route wire harness, and
connect at PCB as outlined in the manual.

Section 4: Bypass Physical Connections

Remove the access plate, bypass assembly, and install the new
bypass assembly as per the instructions provided.

Section 5: Initial Startup

Test the bypass assembly after installation to ensure proper
functioning.

Section 6: Professional Service and Maintenance

Refer to the manual for servicing, winterizing, spring startup,
and handling occasional freezing temperatures.

FAQ

Q: What should I do if some parts are missing from the

package?

A: If any parts are missing or incorrect, please call your local
distributor or Zodiac Pool Systems LLC technical support at
1.800.822.7933 for assistance.

“`

Installation and Operation Manual
VersaFloTM Integrated Bypass JXiTM & JXiQTM Pool and Spa Heaters
Essential installation and startup instructions are included in this manual. Additional operation and troubleshooting information is available online by scanning the QR code with your phone or visiting jandy.com
WARNING
If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. FOR YOUR SAFETY – This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exist. The maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual can be followed exactly. Before installing this product, read and follow all warning notices and instructions that accompany this product. Failure to follow warning notices and instructions may result in property damage, personal injury, or death. Improper installation and/or operation may void the warranty. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS · Immediately switch off main gas supply. · Do not try to light any appliance. · Do not touch any electrical switch; do not use any phone in your building. · Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. · If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Improper installation and/or operation can create unwanted electrical hazard which may cause serious injury, property damage, or death. ATTENTION INSTALLER ­ This manual contains important information about the installation, operation and safe use of this product. This information should be given to the owner/operator of this equipment.

ENGLISH

Jandy® VersaFloTM Integrated Bypass for JXiTM & JXiQTM Pool and Spa Heater | Installation & Operation Manual

Table of Contents

Section 1. General Information ………………… 3 1.1 Introduction ………………………………………… 3 1.2 Technical Assistance ……………………………. 3
Section 2. Overview…………………………………. 3 2.1 JXIVFKIT: VersaFlo Integrated
Bypass Kit ………………………………………….. 3 2.2 Efficiency ……………………………………………. 4
Section 3. Electrical Connections…………….. 5 3.1 Open the Heater ………………………………….. 5 3.2 Route Wire Harness……………………………… 8 3.3 Connect at PCB…………………………………. 10

Section 4. Bypass Physical Connections …. 10 4.1 Remove Access Plate…………………………. 10 4.2 Remove Bypass Assembly………………….. 10 4.3 Install New Bypass Assembly ……………… 11
Section 5. Initial Startup…………………………. 11 5.1 Test Bypass Assembly………………………… 11
Section 6. Professional Service and Maintenance …………………… 12
6.1 Servicing…………………………………………… 12 6.2 Winterizing and Spring Startup ……………. 12 6.3 Occasional Freezing Temperatures ………. 12

EQUIPMENT INFORMATION RECORD Date of Installation _____ Installer Information __ Initial Pressure Gauge Reading (with Clean Filter) ____ Pump Model _ Horsepower___ Notes



Page 2

Jandy® VersaFloTM Integrated Bypass for JXiTM & JXiQTM Pool and Spa Heater | Installation & Operation Manual
Section 1. General Information
SAVE THESE INSTRUCTIONS

ENGLISH

1.1 Introduction
Read completely before proceeding with the installation. This manual provides installation instructions for the VersaFlo Integrated Bypass Accessory Kit for the JXi & JXiQ pool and spa gas heater product line.
1.2 Technical Assistance For technical support or questions, contact your local Zodiac® distributor or Zodiac Pool Systems LLC at 1.800.822.7933.
Section 2. Overview
2.1 JXIVFKIT: VersaFlo Integrated Bypass Kit
2.1.1 Package Contents Before starting, check that you have the correct parts as indicated below. If any parts are missing or incorrect, please call your local distributor or Zodiac Pool Systems LLC technical support at 1.800.822.7933 for assistance.
NOTE: Check the rating plate on your heater and note the serial number revision. If your heater serial number is revision “G” (GXXXXXX) or earlier you will also need to order: (R0719500) – PIB Kit (R0719400) – Flue Sensor Kit to complete the installation.

1 6

5

4 2

7 3

Item

Description

Qty.

1

VersaFlo Integrated Bypass w/JXiQ Wire Harness

1

2

Installation Hardware

6

3

5/16″ Light Duty Wrench

1

4

Knockout Bushing

1

5

Zip Tie

4

6

Seal

1

7

JXi Wire Harness

1

Page 3

ENGLISH

Jandy® VersaFloTM Integrated Bypass for JXiTM & JXiQTM Pool and Spa Heater | Installation & Operation Manual

2.1.2 Required Equipment

Safety Eyewear

Gloves

Phillips Screwdriver

Flat Screwdriver

2.2 Efficiency
The VersaFlo Integrated Bypass allows for increased hydraulic efficiency when the heater is not firing. When the JXi & JXiQ heater is not firing, a flow gate in the bypass assembly is moved to the bypass position, allowing the water flow within the heater header to bypass the heat exchanger and return directly to the pool. Please note, when in the bypass position a small amount of water will still flow through the heat exchanger. When the heater is firing, the flow gate moves to heat position which directs water through the heat exchanger. When the heater is turned off, the bypass will remain in the heat position for approximately one minute before moving to the bypass position.

When the flow gate is in the bypass position and water is bypassing the heat exchanger, the head loss through the heater is significantly reduced as illustrated in Figure 1. To maximize energy savings, combine with an automation system and a variable speed filtration pump to reduce pump speed while flow is bypassing the heater.
Use head loss chart below to determine the best flow rate or filtration run time to best optimize your water circulation system.

Design Head Loss ( ft Head) Design Pressure Drop (psi)

JXi/JXiQ 200K BTU Heater JXi/JXiQ 260K BTU Heater
20.0

JXi/JXiQ 400K BTU Heater JXi/JXiQ VersaFloTM Bypass
9.0

18.0

8.0

16.0 7.0
14.0 6.0
12.0 5.0
10.0 4.0
8.0
3.0 6.0
2.0 4.0

2.0

1.0

0.0

0.0

20

30

40

50

60

70

80

90

100

110

Flow Rate (GPM)

Figure 1. Head Loss Chart

Page 4

Jandy® VersaFloTM Integrated Bypass for JXiTM & JXiQTM Pool and Spa Heater | Installation & Operation Manual

ENGLISH

Section 3. Electrical Connections
Before beginning the installation or replacement of the VersaFlo Integrated Bypass the following steps must be taken.
a. All power to the heater and filter pump must be disconnected at the breakers.
b. The gas supply to the heater must be shut off. c. (Optional) The water can be drained from the
heater by removing the drain plug (drain plug & outer temp sensor on JXiQ models) at the header. See Figure 2.
JXI
JXIQ

3.1 Open the Heater
1. Remove the screws holding the front heater panel in place to expose the raceway. See Figure 3.
2. Locate the raceway lock release label on the interior of the heater raceway.
3. Cut the zip tie to release raceway. See Figure 4 (a).
4. Using a screwdriver or comparable tool; press into the raceway release orifice until the raceway latch releases and the raceway swings free. See Figure 4 (b).
5. Swing the raceway up into a horizontal position. See Figure 4 (c).
6. Latch raceway into position using the bracket. See Figure 4 (d).
7. Remove the 4 screws holding the top cover in place. See Figure 5.
8. Remove the top cover being mindful not to damage or strain the user interface wiring. See Figure 5.

Figure 2. Drain Header
WARNING/ SHOCK HAZARD
Follow all applicable installation codes. Prior to installation or performing any service, turn off all switches and the main breaker in the pool/spa pump electrical circuit. Failure to comply may cause a shock or hazard resulting in severe personal injury or death. While disconnecting and/or connecting any electrical wiring, be careful not to damage or abrade any of the wiring.
WARNING
In order to prevent the risk of fire or electrocution, all electrical power and gas supply to the heater must be disconnected.

NOTE: Some heater models may require the removal of 6 or 8 screws.
Figure 3. Remove Front Panel

Page 5

ENGLISH

Jandy® VersaFloTM Integrated Bypass for JXiTM & JXiQTM Pool and Spa Heater | Installation & Operation Manual

A

tooltip

c

2A ATO

a

Y R ACT SW
24 VAC BYPASS

b

Y R ACT SW
24 VAC BYPASS

WPS HL

AUX LOUVER

d

2A AT

1

30 R Kit # R0984000 29 Only provide external power to items 7, 1

28

1 Fuse

27

2 Ignition Control LED

3 RS-485 LED

4 User Interface LED

26

5 User Interface

6 Blower 25
7 Power Input 5A @120/240V

8 Igniter/Flame Strength

24

9 Igniter

10 Transformer

23

11 Louver

12 Auxiliary

13 Spa 3 wire

22

14 Com

15 Pool 21

APS GPS GV

WPS HL

Figure 4. Access and Latch Raceway

Figure 5. Remove Top Panel Page 6

Jandy® VersaFloTM Integrated Bypass for JXiTM & JXiQTM Pool and Spa Heater | Installation & Operation Manual

ENGLISH

JXiQ

Optional VersaFloTM Bypass Accessory
Accessory Leads

B/BK G/BK PK PK

WATER PRESSURE
SWITCH

V GY W W
LIMIT LIMIT SWITCH SWITCH 135º F 150º F (57º C) (66º C)

WPS HL

Y R BYPASS ACT SW
24 VAC

2A ATO FUSE

AUX LOUVER
APS GPS GV

NO Y/BK O

Y

NC AIR
FLOW SWITCH

NC

BR W

GAS PRESSURE GAS
SWITCH VALVE

W

FLOAT

INLET OUTLET FLUE

INLET BLK BLK

W W

WATER

BLK BLK

TEMP

SENSOR
Remote Mode Set-Up 1. Press/Hold P M S for 5 seconds: SERVICE MENU 2. Press E : REMOTE

OUTLET WATER TEMP SENSOR

FLUE TEMP SENSOR

3. Select desired Remote Mode or . Press E

Wiring Configuration for Remote Modes

2 Wire
SPA COM POOL

3 Wire
SPA COM POOL

RS-485
1 2 34 R B Y G

USER INTERFACE

BLOWER MOTOR

IGN IGN / FS TRANSFORMER

BLK GY

RS-485

R BLK YEL GRN SPA COM POOL

LOUVER PUMP

BLK – BLACK BL – BLUE B/BK – BLUE WITH BLACK TRACE G/BK – GREEN WITH BLACK TRACE PK – PINK BR – BROWN G – GREEN GY – GRAY O – ORANGE R – RED V – VIOLET
W – WHITE Y – YELLOW Y/BK – YELLOW WITH BLACK TRACE

BLOWER W
BL RY BLK POWER

230V 115V
R L2 N BLK L1 L G GG

BL

R

BLK

24 VAC

W

Y

W

W

HOT SURFACE IGNITER

Ensure that L1 and NEU are not reversed.

230V 115V

R

L2 N

BLK

L1

L

G

G

G

System will automatically detect voltage configuration.

JXi

Alternate 120V Wiring*

120 VAC HEATER POWER

NEUTRAL R HOT BK

SUPPLY

G

Voltage Selector Card Must Be Rotated.

240 VAC HEATER POWER

R BK

SUPPLY G

R BL W

ACN1 F1
L2

BK BK BK

L1 ACH1 F2

TRANSFORMER

FUSE

W

R

BK

24 VAC

BL

Y

W
BK BL

BK

BLOWER

R Y

MOTOR

BL

W

BL BK R
F1 F2 24 FV+ FVVAC
IGNITION CONTROL

IGN 120

L1

L2

IGN FS

PSW

W

VAL GND

GY BK W BK O Y/BK BR Y

GY
W W
HOT SURFACE IGNITER

O Y/BK C NO
NC AIR FLOW SWITCH

BR Y GAS VALVE

VersaFloTM Bypass

WATER

TEMP

BK

SENSOR

BK

BR Y

VENT

TEMPERATURE W

LIMIT

240°C

W

(464°F)

UNIVERSAL CONTROLLER USER INTERFACE
POWER INTERFACE
BK O BL R

AquaLink RS

WTEAMTEPR(j)
COIL/AIR TEMP

GAS VALVE

(i)

UNIVERSAL CONTROLLER POWER INTERFACE

(h)

FTLEMP(g) INTUESREFRACE1(f) (e)

(d)
HIPRESS/ HILIMIT

BK OBL R

WW

(k)

BYPASS MOTOR

(l)SBWYPITACSHS

J3 CONNECTOR

FAN/

LOUVER

O

(a)

PUMP COMP/

Y/BK

IGN

R

24VAC

Y

(c)

(b)

REV VALVE

WATER PRESS

REMOTE SPA POOL COM

GY V

TO PUMP RELAY CONTACTS (IF USED)

FOR AIR LOUVER STARTER (IF USED)

W

LIMIT SWITCH 57°C (135°F)

LIMIT SWITCH 66°C (150°F)

57°C (135°F)

66°C (15W0°FA)TER
PRESS SWITCH

B/BK G/BK PK PK
BK – BLACK BL – BLUE BR – BROWN G – GREEN GY – GRAY O – ORANGE R – RED V – VIOLET W – WHITE Y – YELLOW Y/BK – YELLOW WITH BLACK TRACE B/BK – BLUE WITH BLACK TRACE G/BK – GREEN WITH BLACK TRACE PK – PINK

Figure 6. Wiring Diagrams

Page 7

ENGLISH

Jandy® VersaFloTM Integrated Bypass for JXiTM & JXiQTM Pool and Spa Heater | Installation & Operation Manual

3.2 Route Wire Harness
3.2.1 JXi Heater
NOTE: The new VersaFlo is equipped with the JXiQ wiring harness. Before installation on a JXi heater it will be necessary to replace the wire harness on the new VersaFlo with the included JXi wire harness.
1. Remove the three screws holding the bypass cover in place on the new VersaFlo, see Figure 7 (a).
2. Disconnect the two pink wires from the microswitch, see Figure 7 (b).
3. Disconnect the blue and green actuator wires, see Figure 7 (c).

7. Connect the blue and green wires to the blue and green actuator wires in the new VersaFlo, see Figure 9 (a).
8. Connect the two pink wires to the microswitch in the new VersaFlo, see Figure 9 (b).
9. Secure the bypass cover on the new VersaFlo using the three screws, see Figure 9 (c).
a c
b

c

a

b

Figure 7. VersaFlo Remove JXiQ Wiring
4. Pull out the two microswitch wires and the two actuator wires through the opening in the back of the VersaFlo one at a time without damaging grommet, set the JXiQ wire harness aside.
5. Examine the new JXi harness electrical connectors and wires to ensure that none of the wires or connectors are damaged or abraded.
6. Feed the wire terminal end of the two pink microswitch wires and the two green and blue actuator wires from the new JXi wiring harness through the opening in the back of the VersaFlo one at a time, see Figure 8.

Figure 9. Connect Microswitch and Actuator Wires
NOTE: Make sure the pink microswitch wires and the green and blue actuator wires are not pinched by the bypass cover on the new VersaFlo when tightening.
10. Pass the wire terminal end of the two pink wires and the green and blue wires from the new JXi wiring through the electrical orifice on the side panel. See Figure 10 (a). If using the low voltage knockout you may need to remove the cap and replace with the included knockout bushing, see Figure 10 (b).
NOTE: If your heater serial number is revision “G” (GXXXXXX) or earlier you will need to use the low voltage knockout to wire the heater, see Figure 10 (b).
Low Voltage
Knockout b
Electrical a
Orifice

Figure 8. Install JXi Wiring

Figure 10. JXi Electrical Orifice
11. Route the wire along the interior of the heater and behind the high voltage raceway.
12. Secure at raceway brace corner using the installed P-Clamp or the zip ties included with the kit.
13. Route through the standoff along center of the raceway brace. If no standoff is installed please secure with zip ties.
14. Pass the harness through the grommet at the low voltage raceway, see Figure 11 (c).

Page 8

Jandy® VersaFloTM Integrated Bypass for JXiTM & JXiQTM Pool and Spa Heater | Installation & Operation Manual

ENGLISH

RY BLK POWER

Low Voltage Knockout
b

c

Y R ACT SW
24 VAC BYPASS

WPS HL

2A ATO FUSE

USER INTERFACE

BLK GY

IGN IGN / FS TRANSFORMER

Electrical Orifice
a

PCB
Low Voltage Grommet

Figure 11. JXi Bypass Harness Routing

3.2.2 JXiQ Heater
1. Examine the electrical connectors and wires to ensure that none of the wires or connectors are damaged or abraded.
2. Feed the electrical harness through the electrical orifice on the side panel. See Figure 12 (a). If using the low voltage knockout you may need to remove the cap and replace with the included knockout bushing.
NOTE: If your heater serial number is revision “G” (GXXXXXX) or earlier you will need to use the low voltage knockout to wire the heater. See Figure 12 (b).
3. Route the wire along the interior of the heater and behind the high voltage raceway. See Figure 13.
4. Secure at raceway brace corner using the installed P-Clamp or the zip ties included with the kit.
5. Route through the standoff along center of the raceway brace. If no standoff is installed please secure with zip ties.
6. Pass the harness through the grommet at the low voltage raceway, see Figure 14 (b).

Low Voltage
Knockout b Electrical a
Orifice
Figure 12. JXiQ Electrical Orifice and Voltage Knockout

Figure 13. Bypass Harness Routing

Low Voltage Knockout
a
Electrical Orifice
a

RY BLK POWER

b

Y R ACT SW
24 VAC BYPASS

APS GPS GV

WPS HL

AUX LOUVER

2A ATO FUSE

12

3

4

USER

H0774700_REVB

INTERFACE

28 27
26 25
24 23
22 21 20 FLOAT

30 R Kit # R0984000 29 Only provide external power to items 7, 11 & 12.

6

5

1 Fuse

16 RS-485

2 Ignition Control LED 17 Flue Temp

Ignition Timing Sequence:

7

3 RS-485 LED

18 Outlet Temp

Pre-Purge: 15 secs Heat Up: 40 secs

4 User Interface LED 19 Inlet Temp

Ignition: up to 7 secs

5 User Interface 6 Blower

20 Gas Valve

Inter Purge: 15 secs

Post Purge: 45 secs 21 Gas Pressure Switch Lockout will occur after

7 Power Input

22 Air Pressure Switch 3 successive failed

5A @120/240VAC

23 Louver Switch

ignition attempts.

8 Igniter/Flame Strength 24 Auxiliary Switch

10

9 Igniter 5A @120VAC 25 High Limits Switch

8

10 Transformer 11 Louver 12 Auxiliary 13 Spa 3 wire 14 Com 2 wire / 3 wire 15 Pool 2 wire / 3 wire

26 Water Pressure Switch
27 VersaFloTM Switch 28 VersaFloTM Actuator 29 24 VAC R 30 24 VAC Y

CAUTION HIGH VOLTAGE DISCONNECT 9 WIRING BEFORE SERVICING Input Power: 120/240 VAC (5A)
24 VAC (3A), 50/60Hz Ambient: 0°F(-18°C) to 176°F(80°C) UL 60730-1, UL 60730-2-5 CSA E60730-1, CSA C22.2 No. 60730-2-5

19

18

17

INLET OUTLET FLUE

16 RS-485

13 14 15

IGN IGN / FS TRANSFORMER

BLK GY
24 VAC, 50/60 Hz 11 12

R BLK YEL GRN SPA COM POOL

LOUVER PUMP

PCB
Low Voltage Grommet

Figure 14. JXiQ Bypass Harness Routing

Page 9

ENGLISH

Jandy® VersaFloTM Integrated Bypass for JXiTM & JXiQTM Pool and Spa Heater | Installation & Operation Manual

3.3 Connect at PCB
3.3.1 JXi Heater
1. Remove factory installed jumper from Bypass Switch (J22).
2. Connect the 2 pin GR/B and B/BK at the board position Bypass Motor (J21).
3. Connect the 2 pink wires to the 2 terminal connector at board position Bypass Switch (J22) polarity does not matter.
4. Replace zipties as needed.
3.3.2 JXiQ Heater
1. Carefully pass the harness through the low voltage grommet on the raceway, see Figure 14 (b).
2. Connect the quick connect 4 terminal connector GR/BK, B/BK, PK, and PK at the board position Bypass (27 & 28). See Figure 13 (bypass).
3. Replace zipties as needed.
WARNING/ SHOCK HAZARD
Follow all applicable installation codes. Prior to installation or performing any service, turn off all switches and the main breaker in the pool/spa pump electrical circuit. Failure to comply may cause a shock or hazard resulting in severe personal injury or death. While disconnecting and/or connecting any electrical wiring, be careful not to damage or abrade any of the wiring.

Section 4. Bypass Physical Connections
4.1 Remove Access Plate 1. Remove the six screws securing the access plate. 2. Remove the access plate and seal.
Figure 15. Remove Access Panel 4.2 Remove Bypass Assembly 1. Remove the three screws holding the bypass
cover in place. 2. Remove the six screws securing the bypass
assembly. 3. Remove the previously installed bypass and seal. 4. It is advised that the removed bypass and seal be
marked to ensure that they are not confused with the replacement/upgrade equipment.

1

4

5

6

32
NOTE: Follow the torque pattern when reassembling.
Use 5/16″ torque wrench on two interior screws
Figure 16. Install VersaFlo Assembly

Page 10

Jandy® VersaFloTM Integrated Bypass for JXiTM & JXiQTM Pool and Spa Heater | Installation & Operation Manual

ENGLISH

4.3 Install New Bypass Assembly
1. Remove the three screws holding the bypass cover in place.
2. Ensure that the seal is properly seated. 3. Secure the bypass assembly to the header with
six screws.
a. Start all six screws by hand. b. Torque the screws in place following the torque
sequence shown above the note in Figure 16. c. There is an included 5/16″ wrench that can be
used to tighten the 2 interior screws. Do not overtighten!

a
Bypass Gate In Closed Position

Section 5. Initial Startup

5.1 Test Bypass Assembly
1. Restore electrical power to the heater and filter pump.
2. Confirm that the VersaFlo Integrated Bypass is enabled at the heater.
3. On heater user interface; press and hold the

POOL

MENU

SPA

,

and

buttons

for several seconds (while heater is in standby).

4. The service menu will activate.

Using BYPASS option.

scroll to VERSAFLO

5. Verify that the bypass option is enabled.

BYPASS ENABLED

If not, enable the bypass option.
MENU

Press

to exit service mode.

6. Turn on the filter pump.

b
Bypass Gate In Open Position
Figure 17. Bypass Gate and Actuator Positions
7. Inspect for leaks at the bypass header seal and look for any leaks inside the bypass housing.
8. If no leaks are observed, turn on power to the heater and activate.
9. Keep the header actuator control in the OFF (closed) position. The actuator will be in the down stroke (extended) position, see Figure 17 (a).
10. Restore gas to the heater. 11. Turn the header actuator control in the ON (open)
position, and observe that shortly before the heater fires, the actuator will move to the up stroke (open) position. See Figure 17 (b). 12. Turn the heater off. After approximately a oneminute delay the actuator will return to the down position (OFF). See Figure 17 (a). 13. After completing all of the steps to test the bypass accessory and confirming correct operation, replace the bypass housing cover using three (3) screws.

Page 11

ENGLISH

Jandy® VersaFloTM Integrated Bypass for JXiTM & JXiQTM Pool and Spa Heater | Installation & Operation Manual

Section 6. Professional Service and Maintenance
6.1 Servicing
WARNING
SERVICING SAFETY: Service procedures can be hazardous because they involve fuel, gas, electricity, moving parts and procedures which require testing or temporary bypass of safety controls. For this reason, the heater must be serviced only by a qualified professional service technician.
IMPROPER SERVICE HAZARD: The heater incorporates unique design features. Incorrect service of this heater can result in personal injury or damage to property. To avoid such hazards, the heater must be serviced only by a qualified professional service technician.
Zodiac Pool Systems LLC requires that you call a qualified service technician to perform all service and repairs on the heater. To locate a licensed or qualified technician or independent service company in your area, contact Zodiac® Technical Support at: 1.800.822.7933 or www.jandy.com.

Before servicing the heater:
· Confirm that the heater control is set to either POOL or SPA.
· Confirm the temperature set point for either POOL or SPA is high enough to make the heater run given the current water temperature.
· Inspect the Thermal Regulator Valve (TRV) for proper operation and replace if there are signs of scaling or corrosion.
NOTE: The TRV ensures the heater operates at optimal efficiency and proper maintenance of the TRV can extend the life of the heater.
6.2 Winterizing and Spring Startup
In areas where freezing temperatures occur in Winter and the pool or spa will not be used, the pool should be winterized by a qualified pool service technician. Refer to the JXi & JXiQ Installation and Operation Manuals provided with the heater for complete instructions on winterizing and spring startup.
6.3 Occasional Freezing Temperatures
In areas where there are occasional overnight freezing temperatures, the filter pump is often used to keep water circulating through the pool equipment. Although the heater control is OFF, power to the heater must be left on. The bypass accessory has a feature built into the controller circuit board to sense the ambient air temperature. When the air temperature approaches freezing, the bypass gate closes to keep water circulating through the heat exchanger and avoid freezing. Power to the heater must be left on to allow the circuit board to operate.

A Fluidra Brand | Jandy.com | Jandy.ca 2882 Whiptail Loop # 100, Carlsbad, CA 92010, USA | 1.800.822.7933 2-3365 Mainway, Burlington, ON L7M 1A6, Canada | 1.800.822.7933
©2024 Fluidra. All rights reserved. The trademarks and trade names used herein are the property of their respective owners.
H0787800_REVB

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals