Jandy JXi Versa Flo Integrated Bypass Pool and Spa Heaters Instruction Manual
- September 18, 2024
- Jandy
Table of Contents
JXi Versa Flo Integrated Bypass Pool and Spa Heaters
“`html
Specifications
-
Product: VersaFlo Integrated Bypass JXi & JXiQ Pool and Spa
Heaters -
Manufacturer: Jandy
-
Model: JXIVFKIT
Product Usage Instructions
Section 1: General Information
Before proceeding with the installation, read the manual
completely. This manual provides installation instructions for the
VersaFlo Integrated Bypass Accessory Kit for the JXi & JXiQ
pool and spa gas heater product line.
Section 2: Overview
2.1 JXIVFKIT: VersaFlo Integrated Bypass Kit
Before starting the installation, ensure you have all the parts
listed in the package contents. If any parts are missing or
incorrect, contact your local distributor or Zodiac Pool Systems
LLC technical support for assistance.
2.2 Efficiency
When the flow gate is in the bypass position, and water is
bypassing the heat exchanger, head loss through the heater is
significantly reduced. To maximize energy savings, combine with an
automation system and a variable speed filtration pump to reduce
pump speed while flow is bypassing the heater.
Section 3: Electrical Connections
Follow the steps to open the heater, route wire harness, and
connect at PCB as outlined in the manual.
Section 4: Bypass Physical Connections
Remove the access plate, bypass assembly, and install the new
bypass assembly as per the instructions provided.
Section 5: Initial Startup
Test the bypass assembly after installation to ensure proper
functioning.
Section 6: Professional Service and Maintenance
Refer to the manual for servicing, winterizing, spring startup,
and handling occasional freezing temperatures.
FAQ
Q: What should I do if some parts are missing from the
package?
A: If any parts are missing or incorrect, please call your local
distributor or Zodiac Pool Systems LLC technical support at
1.800.822.7933 for assistance.
“`
Installation and Operation Manual
VersaFloTM Integrated Bypass JXiTM & JXiQTM Pool and Spa Heaters
Essential installation and startup instructions are included in this manual.
Additional operation and troubleshooting information is available online by
scanning the QR code with your phone or visiting jandy.com
WARNING
If the information in these instructions is not followed exactly, a fire or
explosion may result causing property damage, personal injury or death. FOR
YOUR SAFETY – This product must be installed and serviced by a contractor who
is licensed and qualified in pool equipment by the jurisdiction in which the
product will be installed where such state or local requirements exist. The
maintainer must be a professional with sufficient experience in pool equipment
installation and maintenance so that all of the instructions in this manual
can be followed exactly. Before installing this product, read and follow all
warning notices and instructions that accompany this product. Failure to
follow warning notices and instructions may result in property damage,
personal injury, or death. Improper installation and/or operation may void the
warranty. Do not store or use gasoline or other flammable vapors and liquids
in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS ·
Immediately switch off main gas supply. · Do not try to light any appliance. ·
Do not touch any electrical switch; do not use any phone in your building. ·
Immediately call your gas supplier from a neighbor’s phone. Follow the gas
supplier’s instructions. · If you cannot reach your gas supplier, call the
fire department. Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
Improper installation and/or operation can create unwanted electrical hazard
which may cause serious injury, property damage, or death. ATTENTION INSTALLER
This manual contains important information about the installation, operation
and safe use of this product. This information should be given to the
owner/operator of this equipment.
ENGLISH
Jandy® VersaFloTM Integrated Bypass for JXiTM & JXiQTM Pool and Spa Heater | Installation & Operation Manual
Table of Contents
Section 1. General Information ………………… 3 1.1 Introduction ………………………………………… 3
1.2 Technical Assistance ……………………………. 3
Section 2. Overview…………………………………. 3 2.1 JXIVFKIT: VersaFlo Integrated
Bypass Kit ………………………………………….. 3 2.2 Efficiency ……………………………………………. 4
Section 3. Electrical Connections…………….. 5 3.1 Open the Heater …………………………………..
5 3.2 Route Wire Harness……………………………… 8 3.3 Connect at PCB…………………………………. 10
Section 4. Bypass Physical Connections …. 10 4.1 Remove Access
Plate…………………………. 10 4.2 Remove Bypass Assembly………………….. 10 4.3 Install New
Bypass Assembly ……………… 11
Section 5. Initial Startup…………………………. 11 5.1 Test Bypass Assembly………………………… 11
Section 6. Professional Service and Maintenance …………………… 12
6.1 Servicing…………………………………………… 12 6.2 Winterizing and Spring Startup ……………. 12
6.3 Occasional Freezing Temperatures ………. 12
EQUIPMENT INFORMATION RECORD Date of Installation _____ Installer Information __ Initial Pressure Gauge Reading (with Clean Filter) ____ Pump Model _ Horsepower___ Notes
Page 2
Jandy® VersaFloTM Integrated Bypass for JXiTM & JXiQTM Pool and Spa Heater |
Installation & Operation Manual
Section 1. General Information
SAVE THESE INSTRUCTIONS
ENGLISH
1.1 Introduction
Read completely before proceeding with the installation. This manual provides
installation instructions for the VersaFlo Integrated Bypass Accessory Kit for
the JXi & JXiQ pool and spa gas heater product line.
1.2 Technical Assistance For technical support or questions, contact your
local Zodiac® distributor or Zodiac Pool Systems LLC at 1.800.822.7933.
Section 2. Overview
2.1 JXIVFKIT: VersaFlo Integrated Bypass Kit
2.1.1 Package Contents Before starting, check that you have the correct parts
as indicated below. If any parts are missing or incorrect, please call your
local distributor or Zodiac Pool Systems LLC technical support at
1.800.822.7933 for assistance.
NOTE: Check the rating plate on your heater and note the serial number
revision. If your heater serial number is revision “G” (GXXXXXX) or earlier
you will also need to order: (R0719500) – PIB Kit (R0719400) – Flue Sensor Kit
to complete the installation.
1 6
5
4 2
7 3
Item
Description
Qty.
1
VersaFlo Integrated Bypass w/JXiQ Wire Harness
1
2
Installation Hardware
6
3
5/16″ Light Duty Wrench
1
4
Knockout Bushing
1
5
Zip Tie
4
6
Seal
1
7
JXi Wire Harness
1
Page 3
ENGLISH
Jandy® VersaFloTM Integrated Bypass for JXiTM & JXiQTM Pool and Spa Heater | Installation & Operation Manual
2.1.2 Required Equipment
Safety Eyewear
Gloves
Phillips Screwdriver
Flat Screwdriver
2.2 Efficiency
The VersaFlo Integrated Bypass allows for increased hydraulic efficiency when
the heater is not firing. When the JXi & JXiQ heater is not firing, a flow
gate in the bypass assembly is moved to the bypass position, allowing the
water flow within the heater header to bypass the heat exchanger and return
directly to the pool. Please note, when in the bypass position a small amount
of water will still flow through the heat exchanger. When the heater is
firing, the flow gate moves to heat position which directs water through the
heat exchanger. When the heater is turned off, the bypass will remain in the
heat position for approximately one minute before moving to the bypass
position.
When the flow gate is in the bypass position and water is bypassing the heat
exchanger, the head loss through the heater is significantly reduced as
illustrated in Figure 1. To maximize energy savings, combine with an
automation system and a variable speed filtration pump to reduce pump speed
while flow is bypassing the heater.
Use head loss chart below to determine the best flow rate or filtration run
time to best optimize your water circulation system.
Design Head Loss ( ft Head) Design Pressure Drop (psi)
JXi/JXiQ 200K BTU Heater JXi/JXiQ 260K BTU Heater
20.0
JXi/JXiQ 400K BTU Heater JXi/JXiQ VersaFloTM Bypass
9.0
18.0
8.0
16.0 7.0
14.0 6.0
12.0 5.0
10.0 4.0
8.0
3.0 6.0
2.0 4.0
2.0
1.0
0.0
0.0
20
30
40
50
60
70
80
90
100
110
Flow Rate (GPM)
Figure 1. Head Loss Chart
Page 4
Jandy® VersaFloTM Integrated Bypass for JXiTM & JXiQTM Pool and Spa Heater | Installation & Operation Manual
ENGLISH
Section 3. Electrical Connections
Before beginning the installation or replacement of the VersaFlo Integrated
Bypass the following steps must be taken.
a. All power to the heater and filter pump must be disconnected at the
breakers.
b. The gas supply to the heater must be shut off. c. (Optional) The water can
be drained from the
heater by removing the drain plug (drain plug & outer temp sensor on JXiQ
models) at the header. See Figure 2.
JXI
JXIQ
3.1 Open the Heater
1. Remove the screws holding the front heater panel in place to expose the
raceway. See Figure 3.
2. Locate the raceway lock release label on the interior of the heater
raceway.
3. Cut the zip tie to release raceway. See Figure 4 (a).
4. Using a screwdriver or comparable tool; press into the raceway release
orifice until the raceway latch releases and the raceway swings free. See
Figure 4 (b).
5. Swing the raceway up into a horizontal position. See Figure 4 (c).
6. Latch raceway into position using the bracket. See Figure 4 (d).
7. Remove the 4 screws holding the top cover in place. See Figure 5.
8. Remove the top cover being mindful not to damage or strain the user
interface wiring. See Figure 5.
Figure 2. Drain Header
WARNING/ SHOCK HAZARD
Follow all applicable installation codes. Prior to installation or performing
any service, turn off all switches and the main breaker in the pool/spa pump
electrical circuit. Failure to comply may cause a shock or hazard resulting in
severe personal injury or death. While disconnecting and/or connecting any
electrical wiring, be careful not to damage or abrade any of the wiring.
WARNING
In order to prevent the risk of fire or electrocution, all electrical power
and gas supply to the heater must be disconnected.
NOTE: Some heater models may require the removal of 6 or 8 screws.
Figure 3. Remove Front Panel
Page 5
ENGLISH
Jandy® VersaFloTM Integrated Bypass for JXiTM & JXiQTM Pool and Spa Heater | Installation & Operation Manual
A
tooltip
c
2A ATO
a
Y R ACT SW
24 VAC BYPASS
b
Y R ACT SW
24 VAC BYPASS
WPS HL
AUX LOUVER
d
2A AT
1
30 R Kit # R0984000 29 Only provide external power to items 7, 1
28
1 Fuse
27
2 Ignition Control LED
3 RS-485 LED
4 User Interface LED
26
5 User Interface
6 Blower 25
7 Power Input 5A @120/240V
8 Igniter/Flame Strength
24
9 Igniter
10 Transformer
23
11 Louver
12 Auxiliary
13 Spa 3 wire
22
14 Com
15 Pool 21
APS GPS GV
WPS HL
Figure 4. Access and Latch Raceway
Figure 5. Remove Top Panel Page 6
Jandy® VersaFloTM Integrated Bypass for JXiTM & JXiQTM Pool and Spa Heater | Installation & Operation Manual
ENGLISH
JXiQ
Optional VersaFloTM Bypass Accessory
Accessory Leads
B/BK G/BK PK PK
WATER PRESSURE
SWITCH
V GY W W
LIMIT LIMIT SWITCH SWITCH 135º F 150º F (57º C) (66º C)
WPS HL
Y R BYPASS ACT SW
24 VAC
2A ATO FUSE
AUX LOUVER
APS GPS GV
NO Y/BK O
Y
NC AIR
FLOW SWITCH
NC
BR W
GAS PRESSURE GAS
SWITCH VALVE
W
FLOAT
INLET OUTLET FLUE
INLET BLK BLK
W W
WATER
BLK BLK
TEMP
SENSOR
Remote Mode Set-Up 1. Press/Hold P M S for 5 seconds: SERVICE MENU 2. Press E
: REMOTE
OUTLET WATER TEMP SENSOR
FLUE TEMP SENSOR
3. Select desired Remote Mode or . Press E
Wiring Configuration for Remote Modes
2 Wire
SPA COM POOL
3 Wire
SPA COM POOL
RS-485
1 2 34 R B Y G
USER INTERFACE
BLOWER MOTOR
IGN IGN / FS TRANSFORMER
BLK GY
RS-485
R BLK YEL GRN SPA COM POOL
LOUVER PUMP
BLK – BLACK BL – BLUE B/BK – BLUE WITH BLACK TRACE G/BK – GREEN WITH BLACK
TRACE PK – PINK BR – BROWN G – GREEN GY – GRAY O – ORANGE R – RED V – VIOLET
W – WHITE Y – YELLOW Y/BK – YELLOW WITH BLACK TRACE
BLOWER W
BL RY BLK POWER
230V 115V
R L2 N BLK L1 L G GG
BL
R
BLK
24 VAC
W
Y
W
W
HOT SURFACE IGNITER
Ensure that L1 and NEU are not reversed.
230V 115V
R
L2 N
BLK
L1
L
G
G
G
System will automatically detect voltage configuration.
JXi
Alternate 120V Wiring*
120 VAC HEATER POWER
NEUTRAL R HOT BK
SUPPLY
G
Voltage Selector Card Must Be Rotated.
240 VAC HEATER POWER
R BK
SUPPLY G
R BL W
ACN1 F1
L2
BK BK BK
L1 ACH1 F2
TRANSFORMER
FUSE
W
R
BK
24 VAC
BL
Y
W
BK BL
BK
BLOWER
R Y
MOTOR
BL
W
BL BK R
F1 F2 24 FV+ FVVAC
IGNITION CONTROL
IGN 120
L1
L2
IGN FS
PSW
W
VAL GND
GY BK W BK O Y/BK BR Y
GY
W W
HOT SURFACE IGNITER
O Y/BK C NO
NC AIR FLOW SWITCH
BR Y GAS VALVE
VersaFloTM Bypass
WATER
TEMP
BK
SENSOR
BK
BR Y
VENT
TEMPERATURE W
LIMIT
240°C
W
(464°F)
UNIVERSAL CONTROLLER USER INTERFACE
POWER INTERFACE
BK O BL R
AquaLink RS
WTEAMTEPR(j)
COIL/AIR TEMP
GAS VALVE
(i)
UNIVERSAL CONTROLLER POWER INTERFACE
(h)
FTLEMP(g) INTUESREFRACE1(f) (e)
(d)
HIPRESS/ HILIMIT
BK OBL R
WW
(k)
BYPASS MOTOR
(l)SBWYPITACSHS
J3 CONNECTOR
FAN/
LOUVER
O
(a)
PUMP COMP/
Y/BK
IGN
R
24VAC
Y
(c)
(b)
REV VALVE
WATER PRESS
REMOTE SPA POOL COM
GY V
TO PUMP RELAY CONTACTS (IF USED)
FOR AIR LOUVER STARTER (IF USED)
W
LIMIT SWITCH 57°C (135°F)
LIMIT SWITCH 66°C (150°F)
57°C (135°F)
66°C (15W0°FA)TER
PRESS SWITCH
B/BK G/BK PK PK
BK – BLACK BL – BLUE BR – BROWN G – GREEN GY – GRAY O – ORANGE R – RED V –
VIOLET W – WHITE Y – YELLOW Y/BK – YELLOW WITH BLACK TRACE B/BK – BLUE WITH
BLACK TRACE G/BK – GREEN WITH BLACK TRACE PK – PINK
Figure 6. Wiring Diagrams
Page 7
ENGLISH
Jandy® VersaFloTM Integrated Bypass for JXiTM & JXiQTM Pool and Spa Heater | Installation & Operation Manual
3.2 Route Wire Harness
3.2.1 JXi Heater
NOTE: The new VersaFlo is equipped with the JXiQ wiring harness. Before
installation on a JXi heater it will be necessary to replace the wire harness
on the new VersaFlo with the included JXi wire harness.
1. Remove the three screws holding the bypass cover in place on the new
VersaFlo, see Figure 7 (a).
2. Disconnect the two pink wires from the microswitch, see Figure 7 (b).
3. Disconnect the blue and green actuator wires, see Figure 7 (c).
7. Connect the blue and green wires to the blue and green actuator wires in
the new VersaFlo, see Figure 9 (a).
8. Connect the two pink wires to the microswitch in the new VersaFlo, see
Figure 9 (b).
9. Secure the bypass cover on the new VersaFlo using the three screws, see
Figure 9 (c).
a c
b
c
a
b
Figure 7. VersaFlo Remove JXiQ Wiring
4. Pull out the two microswitch wires and the two actuator wires through the
opening in the back of the VersaFlo one at a time without damaging grommet,
set the JXiQ wire harness aside.
5. Examine the new JXi harness electrical connectors and wires to ensure that
none of the wires or connectors are damaged or abraded.
6. Feed the wire terminal end of the two pink microswitch wires and the two
green and blue actuator wires from the new JXi wiring harness through the
opening in the back of the VersaFlo one at a time, see Figure 8.
Figure 9. Connect Microswitch and Actuator Wires
NOTE: Make sure the pink microswitch wires and the green and blue actuator
wires are not pinched by the bypass cover on the new VersaFlo when tightening.
10. Pass the wire terminal end of the two pink wires and the green and blue
wires from the new JXi wiring through the electrical orifice on the side
panel. See Figure 10 (a). If using the low voltage knockout you may need to
remove the cap and replace with the included knockout bushing, see Figure 10
(b).
NOTE: If your heater serial number is revision “G” (GXXXXXX) or earlier you
will need to use the low voltage knockout to wire the heater, see Figure 10
(b).
Low Voltage
Knockout b
Electrical a
Orifice
Figure 8. Install JXi Wiring
Figure 10. JXi Electrical Orifice
11. Route the wire along the interior of the heater and behind the high
voltage raceway.
12. Secure at raceway brace corner using the installed P-Clamp or the zip
ties included with the kit.
13. Route through the standoff along center of the raceway brace. If no
standoff is installed please secure with zip ties.
14. Pass the harness through the grommet at the low voltage raceway, see
Figure 11 (c).
Page 8
Jandy® VersaFloTM Integrated Bypass for JXiTM & JXiQTM Pool and Spa Heater | Installation & Operation Manual
ENGLISH
RY BLK POWER
Low Voltage Knockout
b
c
Y R ACT SW
24 VAC BYPASS
WPS HL
2A ATO FUSE
USER INTERFACE
BLK GY
IGN IGN / FS TRANSFORMER
Electrical Orifice
a
PCB
Low Voltage Grommet
Figure 11. JXi Bypass Harness Routing
3.2.2 JXiQ Heater
1. Examine the electrical connectors and wires to ensure that none of the
wires or connectors are damaged or abraded.
2. Feed the electrical harness through the electrical orifice on the side
panel. See Figure 12 (a). If using the low voltage knockout you may need to
remove the cap and replace with the included knockout bushing.
NOTE: If your heater serial number is revision “G” (GXXXXXX) or earlier you
will need to use the low voltage knockout to wire the heater. See Figure 12
(b).
3. Route the wire along the interior of the heater and behind the high
voltage raceway. See Figure 13.
4. Secure at raceway brace corner using the installed P-Clamp or the zip ties
included with the kit.
5. Route through the standoff along center of the raceway brace. If no
standoff is installed please secure with zip ties.
6. Pass the harness through the grommet at the low voltage raceway, see
Figure 14 (b).
Low Voltage
Knockout b Electrical a
Orifice
Figure 12. JXiQ Electrical Orifice and Voltage Knockout
Figure 13. Bypass Harness Routing
Low Voltage Knockout
a
Electrical Orifice
a
RY BLK POWER
b
Y R ACT SW
24 VAC BYPASS
APS GPS GV
WPS HL
AUX LOUVER
2A ATO FUSE
12
3
4
USER
H0774700_REVB
INTERFACE
28 27
26 25
24 23
22 21 20 FLOAT
30 R Kit # R0984000 29 Only provide external power to items 7, 11 & 12.
6
5
1 Fuse
16 RS-485
2 Ignition Control LED 17 Flue Temp
Ignition Timing Sequence:
7
3 RS-485 LED
18 Outlet Temp
Pre-Purge: 15 secs Heat Up: 40 secs
4 User Interface LED 19 Inlet Temp
Ignition: up to 7 secs
5 User Interface 6 Blower
20 Gas Valve
Inter Purge: 15 secs
Post Purge: 45 secs 21 Gas Pressure Switch Lockout will occur after
7 Power Input
22 Air Pressure Switch 3 successive failed
5A @120/240VAC
23 Louver Switch
ignition attempts.
8 Igniter/Flame Strength 24 Auxiliary Switch
10
9 Igniter 5A @120VAC 25 High Limits Switch
8
10 Transformer 11 Louver 12 Auxiliary 13 Spa 3 wire 14 Com 2 wire / 3 wire 15 Pool 2 wire / 3 wire
26 Water Pressure Switch
27 VersaFloTM Switch 28 VersaFloTM Actuator 29 24 VAC R 30 24 VAC Y
CAUTION HIGH VOLTAGE DISCONNECT 9 WIRING BEFORE SERVICING Input Power: 120/240
VAC (5A)
24 VAC (3A), 50/60Hz Ambient: 0°F(-18°C) to 176°F(80°C) UL 60730-1, UL
60730-2-5 CSA E60730-1, CSA C22.2 No. 60730-2-5
19
18
17
INLET OUTLET FLUE
16 RS-485
13 14 15
IGN IGN / FS TRANSFORMER
BLK GY
24 VAC, 50/60 Hz 11 12
R BLK YEL GRN SPA COM POOL
LOUVER PUMP
PCB
Low Voltage Grommet
Figure 14. JXiQ Bypass Harness Routing
Page 9
ENGLISH
Jandy® VersaFloTM Integrated Bypass for JXiTM & JXiQTM Pool and Spa Heater | Installation & Operation Manual
3.3 Connect at PCB
3.3.1 JXi Heater
1. Remove factory installed jumper from Bypass Switch (J22).
2. Connect the 2 pin GR/B and B/BK at the board position Bypass Motor (J21).
3. Connect the 2 pink wires to the 2 terminal connector at board position
Bypass Switch (J22) polarity does not matter.
4. Replace zipties as needed.
3.3.2 JXiQ Heater
1. Carefully pass the harness through the low voltage grommet on the raceway,
see Figure 14 (b).
2. Connect the quick connect 4 terminal connector GR/BK, B/BK, PK, and PK at
the board position Bypass (27 & 28). See Figure 13 (bypass).
3. Replace zipties as needed.
WARNING/ SHOCK HAZARD
Follow all applicable installation codes. Prior to installation or performing
any service, turn off all switches and the main breaker in the pool/spa pump
electrical circuit. Failure to comply may cause a shock or hazard resulting in
severe personal injury or death. While disconnecting and/or connecting any
electrical wiring, be careful not to damage or abrade any of the wiring.
Section 4. Bypass Physical Connections
4.1 Remove Access Plate 1. Remove the six screws securing the access plate. 2.
Remove the access plate and seal.
Figure 15. Remove Access Panel 4.2 Remove Bypass Assembly 1. Remove the three
screws holding the bypass
cover in place. 2. Remove the six screws securing the bypass
assembly. 3. Remove the previously installed bypass and seal. 4. It is advised
that the removed bypass and seal be
marked to ensure that they are not confused with the replacement/upgrade
equipment.
1
4
5
6
32
NOTE: Follow the torque pattern when reassembling.
Use 5/16″ torque wrench on two interior screws
Figure 16. Install VersaFlo Assembly
Page 10
Jandy® VersaFloTM Integrated Bypass for JXiTM & JXiQTM Pool and Spa Heater | Installation & Operation Manual
ENGLISH
4.3 Install New Bypass Assembly
1. Remove the three screws holding the bypass cover in place.
2. Ensure that the seal is properly seated. 3. Secure the bypass assembly to
the header with
six screws.
a. Start all six screws by hand. b. Torque the screws in place following the
torque
sequence shown above the note in Figure 16. c. There is an included 5/16″
wrench that can be
used to tighten the 2 interior screws. Do not overtighten!
a
Bypass Gate In Closed Position
Section 5. Initial Startup
5.1 Test Bypass Assembly
1. Restore electrical power to the heater and filter pump.
2. Confirm that the VersaFlo Integrated Bypass is enabled at the heater.
3. On heater user interface; press and hold the
POOL
MENU
SPA
,
and
buttons
for several seconds (while heater is in standby).
4. The service menu will activate.
Using BYPASS option.
scroll to VERSAFLO
5. Verify that the bypass option is enabled.
BYPASS ENABLED
If not, enable the bypass option.
MENU
Press
to exit service mode.
6. Turn on the filter pump.
b
Bypass Gate In Open Position
Figure 17. Bypass Gate and Actuator Positions
7. Inspect for leaks at the bypass header seal and look for any leaks inside
the bypass housing.
8. If no leaks are observed, turn on power to the heater and activate.
9. Keep the header actuator control in the OFF (closed) position. The
actuator will be in the down stroke (extended) position, see Figure 17 (a).
10. Restore gas to the heater. 11. Turn the header actuator control in the ON
(open)
position, and observe that shortly before the heater fires, the actuator will
move to the up stroke (open) position. See Figure 17 (b). 12. Turn the heater
off. After approximately a oneminute delay the actuator will return to the
down position (OFF). See Figure 17 (a). 13. After completing all of the steps
to test the bypass accessory and confirming correct operation, replace the
bypass housing cover using three (3) screws.
Page 11
ENGLISH
Jandy® VersaFloTM Integrated Bypass for JXiTM & JXiQTM Pool and Spa Heater | Installation & Operation Manual
Section 6. Professional Service and Maintenance
6.1 Servicing
WARNING
SERVICING SAFETY: Service procedures can be hazardous because they involve
fuel, gas, electricity, moving parts and procedures which require testing or
temporary bypass of safety controls. For this reason, the heater must be
serviced only by a qualified professional service technician.
IMPROPER SERVICE HAZARD: The heater incorporates unique design features.
Incorrect service of this heater can result in personal injury or damage to
property. To avoid such hazards, the heater must be serviced only by a
qualified professional service technician.
Zodiac Pool Systems LLC requires that you call a qualified service technician
to perform all service and repairs on the heater. To locate a licensed or
qualified technician or independent service company in your area, contact
Zodiac® Technical Support at: 1.800.822.7933 or www.jandy.com.
Before servicing the heater:
· Confirm that the heater control is set to either POOL or SPA.
· Confirm the temperature set point for either POOL or SPA is high enough to
make the heater run given the current water temperature.
· Inspect the Thermal Regulator Valve (TRV) for proper operation and replace
if there are signs of scaling or corrosion.
NOTE: The TRV ensures the heater operates at optimal efficiency and proper
maintenance of the TRV can extend the life of the heater.
6.2 Winterizing and Spring Startup
In areas where freezing temperatures occur in Winter and the pool or spa will
not be used, the pool should be winterized by a qualified pool service
technician. Refer to the JXi & JXiQ Installation and Operation Manuals
provided with the heater for complete instructions on winterizing and spring
startup.
6.3 Occasional Freezing Temperatures
In areas where there are occasional overnight freezing temperatures, the
filter pump is often used to keep water circulating through the pool
equipment. Although the heater control is OFF, power to the heater must be
left on. The bypass accessory has a feature built into the controller circuit
board to sense the ambient air temperature. When the air temperature
approaches freezing, the bypass gate closes to keep water circulating through
the heat exchanger and avoid freezing. Power to the heater must be left on to
allow the circuit board to operate.
A Fluidra Brand | Jandy.com | Jandy.ca 2882 Whiptail Loop # 100, Carlsbad, CA
92010, USA | 1.800.822.7933 2-3365 Mainway, Burlington, ON L7M 1A6, Canada |
1.800.822.7933
©2024 Fluidra. All rights reserved. The trademarks and trade names used herein
are the property of their respective owners.
H0787800_REVB
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>