Vartai SFO 80 DC Shaft Motor User Manual

September 18, 2024
Vartai

SFO 80 DC Shaft Motor

“`html

Specifications

  • Model: SFO 80, SFO 120, SFO 150
  • Input power: 80W, 120W, 150W
  • Supply voltage: DC24V
  • Motor voltage: DC24V
  • Motor torque: 8N.m (SFO 80), 16N.m (SFO 120, SFO 150)
  • Output torque: 16N.m
  • Output speed: 25 R/min
  • Max output revolution: 15 Circles
  • Safety warning: Yes
  • Output hole/shaft: Hole 25.6 with 90% environment humidity
  • Fire interface: Yes
  • Reception frequency: 433.92MHz with Rolling code decoding
  • Applicable door: Yes

Product Usage Instructions

Installation Instructions

  1. Thread the motor on the shaft and place the bracket on the
    side.

  2. Mark and punch the positioning hole on the wall, then fix the
    bracket with M8*50 expansion screws.

  3. Fix the motor on the bracket with M8*16 hex socket screws.

  4. Align the keyway pipe groove of the door body with the motor
    shaft groove, insert the pin key, and tighten the top screws.

  5. Remove the white cover and cover plate as indicated, if
    necessary.

  6. Add an installation bracket at the bottom of the motor to
    prevent swinging during operation.

  7. Insert the power cord into the motor socket and plug into the
    power source, ensuring the motor is in a locked state.

  8. Set limits on the circuit board if needed.

Optional Terminals and Connections

A. WALL BUTTON connections: 24V GND PB GND PE STOP IN OUT

B. PHOTOCELLS connections: 24V GND PB GND PE STOP IN OUT

C. SCRAM SWITCH connections: 24V GND PB GND PE STOP IN OUT

D. ELECTRONIC LOCK connections: 24V GND PB GND PE STOP IN
OUT

FAQ

Q: Can additional functions be added to the DC Shaft

Motor?

A: Yes, users can purchase and configure additional functions
such as electronic lock, infrared barrier prevention, rebound
switch, safety touch, smart camera, and remote control.

Q: How do I release the motor in case of an emergency?

A: The motor is equipped with a clutch. When the power is off,
pull the rope to clutch the motor and door.

“`

DC Shaft Motor
User Manual

1. Introduction
Applicable EnvironmentInstall in the garage, shops and other external doors Environmental temperatureBetween -20¥ and 40¥ Environmental humidityBelow 90%
2. Functional features
Electronic itineraryAccurate opening height and closing gap. Micro controlSingle key remote control, realize the cycle of opening, stopping, closing and stopping, the lights will be on automatically after opening and closing, and will be off automatically after 3 minutes.With overload, overheat, low voltage detection and other protection functions. Bluetooth control: Adopting Bluetooth control, stable signal, strong anti-interference ability, adjusting various parameters through the mobile app, easy to operate. Password protectionRolling code, theft prevention, safe and reliable.
DC motor Low noise, realizing soft start and soft stop, making the operation more stable, and protect the motor to extend service life. Emergency releaseThe motor is equipped with clutch, pull the rope when the power is off,
to clutch the motor and door.
3. External Function

Function
Function Description

Electronic lock
Theft prevention

Infrared
Barrier prevention

Rebound switch
Barrier prevention

Safety touch
Barrier prevention

Smart camera
Remote control

The above functions can be purchased and configured by users.

4. Technical Specifications

Model Input power Supply voltage Motor voltage Motor torque Output torque(N.m) Output speed(R/min) Max output revolution Level Safety warning Output hole/shaft Environment humanity Fire interface Reception frequency Decoding Applicable door

SFO 80

SFO 120

SFO 150

80W

120W

150W

230V±10% 50/60Hz 230V±10% 50/60Hz 230V±10% 50/60Hz

DC24V

DC24V

DC24V

8N.m

8N.m

8N.m

16N.m

16N.m

16N.m

25

25

25

15 Circles

15 Circles

15 Circles

S2

S2

S2

Yes

Yes

Yes

Hole 25.6
90%

Hole 25.6
90%

Hole 25.6
90%

Yes

Yes

Yes

433.92MHz

433.92MHz

433.92MHz

Rolling code

Rolling code

Rolling code

5. Installation Introduces

Product figure and dimension figure

1

2

6

PC NO

PART NAME

QTY

7

1 Shaft motor

1

8

2 Remote control

2

3 Power cord

1

4

M8x16 hexagon socket flat round head bolt

4

5

M6x14 hexagon socket flat round head bolt

2

6

M8x50 outer hexagonal round head expansion bolt

5

7 Bracket 1

1

8 Bracket 2

1

4

5

9

10

9 Flat key 6.359.5375

1

10 Locating sleeve

1

3

Dimension figure

6. Installation Figure Installation Step

1. The motor is threaded on the shaft, the bracket is placed on the side, the positioning hole is marked on the wall and punched, the bracket is fixed on the wall with M8*50 expansion screws.

2. The motor is fixed on the bracket with 8*16 hex socket screws, and then the door body is pushed to make the groove of the keyway pipe match the groove of the motor shaft,and the pin key is inserted. Install the locating sleeve and tighten the top screws.

3. At the arrow position on the white cover, push up wards to remove the white cover. at the arrow position on the cover plate, push down wards to remove the cover plate.

4. To prevent the motor from swinging during operation, an installation bracket is added at the bottom of the motor.adjust the bracket to find the appropriate position, fix the bracket to the wall with M850 expansion screws, and then fix the bracket to the bottom of the motor with M614 screws.
SET UP

CODE DOWN

5. Insert the power cord into the motor socket, plug into the power source, and power on the motor pulling down the green bead is locking, and during debugging, ensure that the motor is in a locked state.(pulling down the red bead is the clutch, pulling down the green bead is the lock.)

6. You can set the limit on the circuit board.
3

7. Optional Terminals and Connections

A WALL BUTTON

24V GND PB GND PE STOP IN OUT

PB GND

B PHOTOCELLS

24V GND PB GND PE STOP IN OUT

NC

24V GND PB GND PE STOP IN OUT

0V 12/24V
+24V GND

0V 12/24V COM NO/NC
PE GND
+24V
C SCRAM SWITCH

24V GND PB GND PE STOP IN OUT

GND STOP

D ELECTRONIC LOCK

24V GND PB GND PE STOP IN OUT

RED BLACK
4

GREEN YELLOW

8. Programming the Operator

Function settings

Corresponding numbers/characters

Setting Open Positions

1

Setting Close Positions

2

Close Force Adjusting

3

Auto-Lock Function

4

Adjusting of Opening Force

5

Adjusting of Closing Speed

6

Ventilation Position

7

Installation Direction Setting

8

Electronic Lock

9

Garden Function

A

Remote Control To Enter Into Learning Mode

b

Follow Function

C

Stop Switch NO/NC Setting

d

Maintenance Reminder Function

E

5

1.1

Preparing

1.1.1 Pull the green bead to ensure that the motor is in a locked state.

Plug in the power, the display screen will show the version number for 2 seconds, and then 1.1.2 the LED will turn off, and the motor will enter standby mode.

1.2

Setting open and close positions

1.2.1

Press and hold P, and release when the LED display shows “1”, entering the door upper limit setting state.

1.2.2

Then press and hold ” ¶” key until you reach the right position, it flashes “n” during the process.

1.2.3 Press “P” to confirm the open position. The display will then show “2” and wait for the close position setting.

1.2.4 Then press and hold “” key, it flashes “u” .

Press the “P” key to confirm finish the setting, it flashes “n”. door will automatically 1.2.5 run one complete cycle by moving to the fully opened position and back to fully
closed position.

1.2.6 “11” will be displayed to end the setting.displaying a “-” indicates that the setting has failed and the itinerary needs to be reset.

1.3

Adding transmitters

1.3.1 Press “C” key, it displays ” “.

1.3.2

Click the button on the remote control, then release and press the same button again, ” ” flashes.

1.3.3

Then it displays “11” to show setting is complete. repeat up steps to code a maximum of 20 different transmitters ‘ and/or buttons.

1.4

Clear /reset all remoter

1.4.1 When the unit has stored full codes, it flashes “F”, or preventing coding mistakes, it is necessary to cancel all the stored codes.

1.4.2 Press and hold “C” key, it displays ” “. hold more than 8 seconds.

1.4.3 It displays “C” flashing, show the code clearing is complete.

1.5

Auto-close function

Long press “¶” key and hold on until the number is displayed on the screen, then 1.5.1 release “¶” key, at this time, it will display “0” to “9”.

1.5.2 1.5.3

Press “¶” or “” to adiust. “0”means AUTO-CLOSE function is invalid. “1-9”
means that the time is:10s, 20s, 30s, 40s, 50s, 60s, 90s, 120s, 180s.

After setting, press “P” to confirm. Default setting: “0”.

1.6

Infrared function

1.6.1

Long press “” key and hold on until the number is displayed on the screen, then release “” key, at this time, it will display “II” or “H”.

Press “¶” or “” key to adjust whether the infrared is effective or not, and 1.6.2 press “P” key to confirm. “II” means the infrared is not effective, “H” means the
infrared is effective.

1.6.3 Default setting: “H”.

1.7

Close force adjusting

1.7.1

Press and hold the “P” key until it displays “3”. Then it will show the current rebound force setting (with “5” as the default).

1.7.2

Use “¶” or “” key to adjust the rebound force (9 is the max and 1 is the mini) . press “P” key to confirm.

1.8

Auto-lock function

1.8.1

Press and hold the “P” key until it displays “4”. (with “0” as the default for disabled automatic lock).

1.8.2

Press “¶” to change the setting. “1” to enable, “0” to disable. press the”P” key to
confirm.

1.9

Adjusting of opening force

1.9.1 Long press “P” key and hold on, it displays “5”. release “P” key, it display “1” to “9” adjustable.

1.9.2

Press “¶” or “” key to adjust. form “1” to “9”, there are 9 grades. “9” is max, and “1” is mini, press “P” key to save, return back to standby mode.

1.9.3 Default setting: “9”.

2.1

Adjusting of closeing speed

2.1.1

Press and hold the “P” key until it displays “6”. Then it will show the current opening force setting (with “7” as the default).

2.1.2

Press “¶”or “” to adjust. “5” is 50% of full speed, “6” is 60%, “7” is 70%, and “0” is 100%,press “P’ to confirm.

2.2

Set ventilation position

2.2.1

Long press “P” key and hold on, it displays “7”. release “P” key, it display “0” to “9” adjustable.

Press “¶” or “”key to adjust. the display “0”means that the ventilation function
2.2.2 is off; the display “1” to “9” means that the ventilation position is the set value (1-9)x5CM; press the “P” key to save and return to standby state.

2.2.3 Default setting: “0”.

7

2.2.4

Instructions: The height of ventilation position is calculated from the close limit. If the setting position is bigger than the open limit, it can only be opened to the open limit. after the door is completely closed, press the ventilation key on the remote control, and the door will open and stop at the ventilated position set.

If “0” is set, the door can be controlled by the ventilation key after learning. If “1” to “9” is set,
2.2.5 the ventilation key can only control the open ventilation position, and other keys must be
learned to control the door.

2.3

Installation direction setting

2.3.1

Long press “P” key and hold on, it displays “8”. release “P” key, it display “0” or “1” adjustable.

During the adjusting, if the setting direction is wrong. it only needs press “¶” or 2.3.2 “” key to adjust change the “0” or “1” in the menu of 8 to solve the problem.
After setting, press “P” to confirm.

2.3.3 Default setting: “0”.

2.4

Electronic lock

2.4.1 2.4.2

Long press “P” key and hold on, it displays “9”. release “P” key, it display “0” or “1” adjustable.
Press “¶” or “” key to adjust. “1”means the electronic lock function on, “0” means the electronic lock function off, after setting, press “P” key to confirm.

2.4.3 Default setting: “0”.

2.5

Garden function

2.5.1

Long press “P” key and hold on, it displays “A”. release “P” key, it display “0” to “2” adjustable.

Press “¶” or “” key to adjust. “1”means the garden function opens. during the 2.5.2 door opening and receive the control signal, the door will stop, again received the
control signal, will open the door till the top, closed the door when receive the signal.

2.5.3

“2”means the garden function opens. when the door is closed, press the remote control, and the door will be opened directly after the door stops. when the door is opened, press the remote control, and the door will be opened to the top without signal control.

2.5.4 “0”means the garden function off. after setting, press “P” key to confirm.

2.5.5 Default setting: “0”.

2.6

Remote control to enter into learning mode

2.6.1

Long press “P” key and hold on,it displays “b”. release “P” key, it display “0” or “1” adjustable.

2.6.2

Press the “¶” displays “1”, press “” displays “0”,press “P” key to save settings, return to standby mode. “0”: Remote control learning is not supported. “1”: When the coded remote control presses 2+4 at the same time and holds for 5s, it enters the coded state and flashes the light at the same time. After learning successfully or 10s, it will return to standby state.

2.6.3 Default setting: “0”.

8

2.7

Follow function

2.7.1 2.7.2

Long press “P” key and hold on, it displays “C”. release “P” key, it display “0” to “9” adjustable.
Pressthe “¶” or “” key to adjust the settings. The display is “0”,indicating invalid function; the display is 1-9, indicating 1-9 seconds.

2.7.3 Default setting: “0”.

2.7.4

This function is only effective when the photoelectric protection and automatic door closing function are turned on and when the external infrared ray is connected.

2.8

Stop swltch NO/NC setting

2.8.1

Long press “P” key and hold on,it displays “d”. release “P” key, it display “0” or “1” adjustable.

2.8.2

Press “¶” or “” key to adjust. “0”means the function is NO, “1” means the terminal is NC. after setting, press “P” key to confirm.

2.8.3 Default setting: “0”.

2.9

Maintenance reminder function

2.9.1

Long press “P” key and hold on,it displays “E”. release “P” key, it display “0” or “9” adjustable.

Press “¶” or “” key to adjust the maintenance times of the door body. “0” is 2.9.2 closed,1=5000, 2=10000,3=15000… 9=45000, after selecting the maintenance
times, press the setting key to confirm and finish the setting.

2.9.3 When the set value is reached, each time the light starts flashing and alarms for 2 minutes.

2.9.4

When you need to reselect counting, first select “0”, then set the required value, and then start counting again.

2.9.5 Count to fully open the door plus 1 time. Default setting: “0”.

3.1

Restore factory setting

3.1.1 Quickly press the “P” key 8 times, and the digital display screen will show the “program version”,
then the screen will display “-” and the program will be restored to factory settings.

3.1.2

After restoring the factory settings, all settings will be cleared and need to be reset.

9

Built- in Bluetooth
1. Install the Built- in Bluetooth application Download and install ” Home Blue.T ” APP from the Google Play or Apple APP Store. or scan the QR code below to download. install the ” Home Blue. T ” APP.

Android

iOS

2. Operation Instructions 1. Please note Bluetooth must be turned on for device setup. 2. Open the Built- in Bluetooth application and enter the main page.then click ” Device List “. 3. Then Click “Add Device”.Scanning for nearby recognizable devices…then Click ” Connect “. 4. Press ” CODE ” button onthe door opener, and whenthe matching light turns onentering Bluetooth
pairingmode. Then click ” Next Step” to start Bluetooth pairing. 5. Note the name and click ” Complete”.

10

3. Main control page
– Function 1 key or 3 keys on the transmitter; – Displays the number of runs;Maintenance Reminder Function; – Electronic Lock Openings/Closings; – Infrared Function Openings/Closings; – Courtyard Function Openings/Closings;.

4. Setting control page

Auto-closing Time
Remotes Coding Limits Setting Force Adjust Back To Factory Setting

Click the settings button to view the current device settings status; Click on the function line to set it, and the functions that can be set include

Auto-closing Time; Follow Function; Ventilate Function; Closing Speed; Remotes Coding;

Limits Setting; Force Adjust; STOP Switch; Back To Factory Setting.

5. PDervsicoenacloCdenctleeraring

Click on “Personal” on the homepage to enter the personal center; FLoenagtupreres:ssAdthmeinhiissttroartiocralOdpetvioicnes,, WOnaernCinlgic,kdMelaeitnetethneandceev,icAeb, normal Alarm, FanededcbliackckC, oNnafmirme Ytoocuor mDpelveitcee.the code clearing.

11

9. Common Problems and Troubleshooting Methods

Problem

Causes

Solution

The light does not work The power is not on after power on, and the motor does not work Fuse damaged

Check the socket and connect the power
Replace the same type of fuse tube

Screw loose of the pressure Tighten the screw of the pressure

The motor does not run plate of speed line

plate of speed line

after learning the route Wrong route learning

First learn the upper limit, then the lower limit

The motor opens normally but cannot close

The photo beam protection function is enabled,the photo beam accessories are not connected, misaligned or the light is blocked

Cancel the set, align transmitters and receivers, clear obstacles on the light

The push button is normal, but remote control operation is invalid

The remote control is not coded

Recode

The battery of the remote Replace with a new battery

control has run out

of the same model

The automatic locking function is enabled

Disable the automatic locking function

The remote control distance is significantly closer
The brightness of indicator light is obviously darker

Low battery power

Replace with a new battery of the same model

When “A” is displayed Automatic locking is on

According to 1.8 the automatic locking function is cancelled

When “b” is displayed Membered

Adjust the appropriate rebound force according to 1.7

When “d” is displayed

The stroke is too short

Reset the upper and lower

when debugging the stroke limit according to 1.2

12

Problem When “F” is displayed When “h” is displayed When “H” is displayed When “L” is displayed When “P” is displayed When “r” is displayed When “S” is displayed

Causes

Solution

The pairing record is full
The red and black wires of the motor are plugged in reverse
Speed measurement abnormal

According to 1.4 Clear Code
Change the direction of the motor wire
Check whether the control line wiring is normal

Electronic lock function open

Turn off electronic lock according to 2.4

Low voltage Infrared effective Emergency stop

Check whether the input voltage is normal
According to 1.6 cancel infrared protection
Check the emergency stop switch

13

WARNING

The power shall be connected by professional person to the socket meeting the construction standards, electrical guidelines and corresponding supply voltage, with well grounded.
Please use the remote control within sight and 30 meters from the motor to avoid safety accidents. Do not stand or cross under the running door. Children are not allowed to play with the remote control.
Installed away from fire, moisture, electromagnetic interference and other places. The installation person shall wear protective glasses and gloves during the installation.
Do not replace or remove parts. Please carefully check the whole door system (hinges,
door bearings, wire ropes, spring and fixed parts) for wear and damage before installation. In the process of route setting, function adjusting and remote control, please ensure that no person or object is in the door driving area. Do not hang the weight on the clutch rope. make sure that no people (especially children) or objects in the door driving area before installation. Only professionals can replace working parts (internal parts of gearbox, chains, anti-drop card, etc.), especially safety parts.

14

240814