IQAir HealthPro Plus Air Purifier Installation Guide
- June 6, 2024
- IQAir
Table of Contents
Getting Started with Your IQAir® HealthPro® Series
Thank you for choosing IQAir for your air cleaning needs. These
instructions will assist you in getting started with your IQAir system in a
matter of minutes. Simply follow the instructions below. To access some of the
more advanced features of your IQAir system, such as the timer, please refer
to the user manual. We recommend that you familiarize yourself with the safety
instructions in the user manual before first use.
Your IQAir system is supplied with the following items:
- User manual
- User and promotional DVD
- Certificate of performance (individually numbered and hand-signed)
- Technical support and warranty registration card
- IQAir referral program card
- Power cord
- Remote control (incl. battery)
- Set of 4 casters
Setting Up Your IQAir System
A) Unpacking
To unpack your IQAir system, open the top of the box and remove the top foam
piece. Lay the box on its side and pull the air cleaner out by its top handle.
Place the system in its upright position and remove all packaging materials.
All related accessories are supplied in a separate top foam piece contained in
the box.
B) Installing the casters
Installing the casters is not necessary to operate the system; however, it may
facilitate moving the air cleaner from room to room. Please refer to the user
manual for caster fitting and removing instructions.
C) Choosing a suitable location
Your IQAir system should be placed in the room where air cleaning is needed
most. It should be located ideally one foot (30 cm) away from the nearest
vertical surface to allow for maximum air circulation.
D) Connecting to the power supply
Plug the connector end of the power cord into the base of the system. Locate a
suitable wall socket and connect the power cord. Your IQAir system is now in
standby mode ready to be switched on.
Using the Electronic Control Panel
A) Switching your IQAir system on and off
To switch the system on or off, simply press the POWER button, located on the
far left of the control panel. The system is intended to run continuously when
users are present. Operating the system 24 hours per day will not harm the
system.
B) Regulating the fan speed
To select the desired fan speed, simply press the ARROW button on the control
panel. When the top speed has been reached, the display will start again at
the lowest fan speed.
C) Setting the clock
Setting the time and day of the week is not necessary for your IQAir system to
keep track of filter life. However, setting the clock is required to program
the system’s daily and weekly timer. For detailed instructions, please refer
to the user manual, Time & Day Setting.
D) Determining the appropriate fan speed
To achieve a significant air quality improvement, your IQAir system should
ideally filter the room’s air volume at least twice per hour at the selected
fan speed. Please refer to the Air Exchange Rates section of the user manual
to determine how many air changes per hour can be achieved in differently
sized rooms at the various fan speed settings.
E) Monitoring filter life
Your IQAir system keeps track of the life of each filter, taking actual fan
speed and usage into account. When a filter is approaching the end of its
useful life, the green LED in the control panel will change color – — first to
orange, then to red. The filter replacement LED indicators are located on the
right side of the control panel within the illustration of the air cleaner.
F) Replacing filters
When a red LED indicator starts to show in the control panel, the
corresponding filter should be replaced. The position of the LED within the
illustration corresponds to the filter’s position within the air cleaner. That
means, if the lowest LED (labeled F1) turns red, the lowest filter (i.e., the
pre-filter) should be replaced. For detailed instructions on how to replace
filters, please refer to the user manual or the instruction leaflet supplied
with the replacement filter. Apart from replacing filters, the IQAir system is
virtually maintenance-free.
Caring for Your IQAir System 3
A) Cleaning the housing
Use a soft clean cloth for cleaning. If required, window cleaning fluid can be
used to remove stains. For tough, non-water-soluble stains, silicone spray can
be used. Do not use any solvents or organic cleaning fluids.
B) IQAir warranty
IQAir HealthPro Series systems come with a limited warranty of 5 years on
parts and labor, excluding filters. Please complete and return the enclosed
warranty registration card soon after purchase or register online at
www.iqair.com/support. The information will
allow us to provide you with swift service should service work become
necessary. At your request, we will also keep you updated with technical and
promotional information relating to your IQAir system. Also, should you refer
a friend, you will automatically qualify to receive a free pre-filter.
C) Technical support and repairs
Should technical issues or questions arise during or after the warranty
period, please contact your point of purchase or call the IQAir Technical
Support Team at 1-888-560-1020 (toll
free), or visit: www.iqair.com/support.