JENNAIR JGD3536G 36 Inch Gas Downdraft Cooktop User Guide
- September 17, 2024
- JENNAIR
Table of Contents
JENNAIR JGD3536G 36 Inch Gas Downdraft Cooktop
Product Specifications
- Model: JGD3536G
- Overall Width: 36 in / 91.4 cm
- Overall Depth: 21 1/2 in / 54.6 cm
- Width of Cooktop Base: 34 1/2 in / 87.7 cm
- Height: 19 15/16 in / 50.7 cm
- Gas Type: Natural Gas (Convertible to LP Gas with conversion kit)
Product Usage Instructions
- Follow the provided dimension guide for proper installation clearances and dimensions.
- This cooktop is factory-set for natural gas use.
- To convert to LP gas, a qualified service technician must use the LP gas conversion kit provided.
- The JX3TM downdraft cooktops support duct-free ventilation with the JDA7000WX* filter kit.
- Ensure proper installation to ventilate air into the room through the toe kick of the base cabinet.
FAQ
- Q: Can the cooktop be converted to LP gas?
- A: Yes, the cooktop can be converted to LP gas using the LP gas conversion kit provided.
- Q: What are the recommended clearances for installation?
- A: Refer to the dimension guide for specific opening/clearance dimensions to ensure safe and proper installation.
PRODUCT DIMENSIONS
MODEL # | **JGD3536G*** |
---|---|
in | |
A | Overall width |
B | Overall depth |
C | Width of the cooktop base |
D | Width of assembled blower motor and plenum |
E | Height from blower motor to the underside of the cooktop |
46.5
F| Width from left side of cooktop base to blower motor| 101/4| 26.0
G| Width from plenum to right side of cooktop base| 913/16| 24.9
H| Height of cooktop base| 41/8| 10.5
I| Height of cooktop with grates| 19/16| 4.0
J| Height from gas inlet to top of grates| 73/16| 18.3
K| Depth of cooktop base| 1915/16| 50.7
L| Height from plenum to underside of cooktop| 163/4| 42.6
TOP VIEW
FRONT VIEW
SIDE VIEW
IMPORTANT: Dimensional specifications are provided for planning purposes
only.
Do not make any cutouts based on this information. Refer to the Installation
Guide before selecting cabinetry, verifying electrical/gas connections, making
cutouts or beginning installation.
All JennAir® appliances are appropriately UL, CUL or CSA approved.
OPENING/CLEARANCE DIMENSIONS
FRONT VIEW
SIDE VIEW
TOP VIEW
IMPORTANT: Dimensional specifications are provided for planning purposes
only.
Do not make any cutouts based on this information. Refer to the Installation
Guide before selecting cabinetry, verifying electrical/gas connections, making
cutouts or beginning installation.
All JennAir® appliances are appropriately UL, CUL or CSA approved.
MODEL # | **JGD3536G*** |
---|---|
in | |
A | Width of the combustible area above the cooking surface (minimum) |
36 | 91.4 |
B | Width from cooktop to fixed wall or other combustible material |
(minimum) | 6 |
C | Width to center of vent opening option (minimum) |
D | Width to outer edge of outlet (minimum) |
**E***
| Height to bottom of uncovered wood or metal cabinet above the cooking surface (minimum)|
30
|
76.2
F| Height to bottom of uncovered wood or metal cabinet (minimum)| 18|
45.7
G| Height to center of vent opening option| 1411/16| 37.3
H| Height to top edge of outlet (minimum)| 12| 30.5
I| Height to top of gas installation area| 6| 15.2
J**| Depth to center of vent opening option| 171/8| 43.5
K| Depth of gas installation area| 6| 15.2
L| Depth of upper cabinet (recommended)| 13| 33.0
M| Depth from cutout to wall (minimum)| 23/8| 6.1
N| Width of cutout| 343/4| 88.3
O| Depth of cutout| 1915/16| 50.6
P| Depth from cutout to front of countertop (minimum)| 21/8| 5.4
e| Recommended electrical access location
g| Recommended gas supply line location
v| Recommended venting location – see pages 3-4 for ducting
information
-
Dimension can be reduced by 6″ (15.2 cm) when the bottom of the wood or metal cabinet is covered by not less than 1/4″ (0.6 cm) flame retardant millboard covered with not less than No. 28 MSG sheet metal, 0.015″ (0.4 mm) stainless steel, 0.024″ (0.6 mm) aluminum or
0.020″ (0.5 mm) copper. -
Based on installation in a 24″ (61.0 cm) deep by 341/2″ (87.6 cm) high base cabinet with an 11/2″ (3.8 cm) thick countertop.
GAS REQUIREMENTS
Natural Gas
- This cooktop is factory-set for use with natural gas.
LP Gas Conversion
- Conversion must be done by a qualified service technician. To convert to LP gas, use the LP gas conversion kit provided with the cooktop.
ELECTRICAL REQUIREMENTS
- 120 V, 60 Hz, AC only, 15 A fused, electrical circuit is required. A time-delay fuse or dedicated circuit is recommended.
VENTING REQUIREMENTS
- This cooktop must be exhausted outdoors unless using the duct-free filter kit (JDA7000WX*). Refer to kit instructions for further information.
LOCATION REQUIREMENTS
- To ensure cooktop base clearance, cabinet side walls need to be wider than the cutout.
- A minimum clearance of 2″ (5.1 cm) is recommended between the blower motor and cabinet for proper cooling. A 6″ (15.2 cm) clearance is recommended for servicing access.
- An under-counter built-in oven cannot be installed under this cooktop.
DUCT-FREE KIT
JDA7000WX – 175/8″ x 103/8″ x 71/2″
JX3™ DOWNDRAFT COOKTOPS WITH DUCT-FREE VENTILATION
The duct-free filter kit (JDA7000WX) is approved for use with JX3™ downdraft
cooktop models JGD3536G, JGD3430G,
JED4536G, JED3536G, JED4430G and JED3430G. The kit filters the air from
the downdraft system and ventilates the conditioned air into the room through
the toe kick of the base cabinet. Do not ventilate the air from the downdraft
system into the base cabinet, base cabinet pedestal, crawl space, wall or
attic.
PRODUCT DIMENSI
MODEL # | **JDA7000WX*** |
---|---|
in | |
A | Width of housing |
B | Height of housing |
C | Depth of housing |
D | Minimum height of toe kick |
E | Minimum depth to toe kick |
EXHAUST CUTOUT LOCATION
The cutout location in the toe kick area of the cabinet floor is dependent
upon the dimensions of the cooktop and base cabinet.
FRONT VIEW
SIDE VIEW
IMPORTANT: Dimensional specifications are provided for planning purposes
only.
Do not make any cutouts based on this information. Refer to the Installation
Guide before selecting cabinetry, verifying electrical/gas connections, making
cutouts or beginning installation.
All JennAir® appliances are appropriately UL, CUL or CSA approved.
DOWNDRAFT COOKTOP DUCTING ARRANGEMENTS
The diagrams below show typical duct arrangements for downdraft cooktops. JX3™
downdraft cooktops also offer a duct-free installation option. For more
details, refer.
DUCTING CONFIGURATIONS
- A. Roof jack
- B. 31/4″ x 10″ (8.3 cm x 25.4 cm) duct – 54′ (16.5 m) maximum
- C. Transition elbow
REAR DUCTING IN WALL TO ROOF
REAR DUCTING THROUGH WALL TO OUTSIDE
- A. 31/4″ x 10″ (8.3 cm x 25.4 cm) duct
- B. Transition elbow
SIDE DUCTING IN TOE KICK TO OUTSIDE
DUCTING REQUIREMENTS
COOKTOP | DUCT LENGTH | DUCT SIZE |
---|
Gas
| 10′ (3.0 m) or less*| 5″ (12.7 cm)
diameter*
Between 10′ (3.0 m) and 60′ (18.3 m)
| 6″ (15.2 cm) diameter
31/4″ x 10″
(8.3 cm x 25.4 cm)
Electric
| 10′ (3.0 m) or less**| 5″ (12.7 cm)
diameter**
Between 10′ (3.0 m) and 60′ (18.3 m)
| 6″ (15.2 cm)
diameter**
31/4″ x 10″
(8.3 cm x 25.4 cm)
- Gas cooktops must use 5″ (12.7 cm) diameter for runs of 10′ (3.0 m) or less.
- May be used to vent straight out the back of the cooktop and directly through the wall.
CALCULATING MAXIMUM DUCTING LENGTH
- Maximum ducting length is 60′ (18.3 m).
- Each 90° elbow equals 5′ (1.5 m) duct.
- Use no more than three 90° elbows.
- Flexible metal vent is not recommended.
- Do not install two elbows together.
NOTES:
-
For ducting runs up to 30′ (9.1 m), install the cooktop as shipped.
-
For ducting runs of 31′ (9.4 m) to 60′ (15.2 cm), remove the restricter ring on the blower inlet housing.
-
For altitudes above 4500′ (1272.0 m), reduce the recommended vent run by 20% for best performance.
-
A. 6″ (15.2 cm) diameter duct – 511/2′ (15.7 m) maximum
-
B. 6″ (15.2 cm) diameter wall cap
-
C. 6″ (15.2 cm) diameter elbow
-
D. 5″ (12.7 cm ) to 6″ (15.2 cm) diameter transition
THROUGH FLOOR BETWEEN JOISTS TO OUTSIDE
IMPORTANT: Dimensional specifications are provided for planning purposes
only.
Do not make any cutouts based on this information. Refer to the Installation
Guide before selecting cabinetry, verifying electrical/gas connections, making
cutouts or beginning installation.
All JennAir® appliances are appropriately UL, CUL or CSA approved.
®/™ ©2024 JennAir. All rights reserved. Used under license in Canada