PowMr POW-HV-EU Series Pure Sine Wave Inverter
Product Information
Please keep this user manual for future reference. You must read, understand, and follow all safety instructions in this document to prevent property damage or personal injury.
- Review all instructions and warning labels before using the device.
- Do not disassemble the device. Send it to a qualified service center for repair or cleaning.
- Disconnect all wiring before maintenance to reduce the risk of electric shock.
- Only qualified personnel should assemble the device with the battery pack.
- Exercise caution when working with metal tools or around batteries.
- Follow installation procedures for disconnecting RC or DC terminals.
- Avoid using the product in areas with explosion hazards.
- Consult the battery manufacturer for compatibility.
- Avoid contact with foreign objects or liquids. Keep the product out of reach of children.
- The inverter must be connected to a permanent grounding system.
Product Usage Instructions
- The POW-HV-EU series inverters are versatile products suitable for a wide range of residential and commercial applications.
- This user manual provides operation and maintenance guidelines for these inverters.
- This manual is designed for professional technicians involved in the installation, operation, and maintenance of lithium batteries, as well as end users seeking technical information.
- Before using the product, carefully review this user manual and keep it in a readily accessible place for future reference.
FAQ
- Q: Can I disassemble the device for cleaning or repair?
- A: No, do not disassemble the device. Send it to a qualified service center for any necessary repairs or cleaning to avoid hazards.
- Q: What precautions should I take when working with batteries?
- A: Exercise extreme caution when working with metal tools or around batteries to prevent short circuits or explosions. Follow all safety instructions provided in the manual.
Important Safety Instructions
Please keep this user manual for future reference!
WARNING: You must read, understand, and follow all safety instructions in
this document.
Failure to follow safety regulations may result in property damage or personal
injury.
Basic Guidelines
- Before using the device, carefully review all instructions and warning labels on the device, battery, and in the manual.
- This product does not contain user-serviceable parts. Do not disassemble the device. If repair or cleaning is needed, send it to a qualified service center. Improper reassembly may lead to short circuits and fire hazards. Do not remove the front panel or operate the product if any panel shows a fault. All operational steps must be performed by qualified personnel. The warranty will be void if the inverter is tampered with.
- To reduce the risk of electric shock, disconnect all wiring before performing any maintenance or cleaning. Simply turning off the device does not eliminate the risk of electric shock.
- Warning: Only qualified personnel should assemble this device with the battery pack.
- Exercise extreme caution when working with metal tools or around batteries, as dropped tools can spark, short-circuit the battery or other electrical parts, and potentially cause explosions.
- When disconnecting AC or DC terminals, strictly follow the installation procedures outlined in the manual.
- Before using this product, read the provided instructions to become familiar with safety features and operating guidelines. This product is designed and tested to international standards and must be used only for its intended purpose.
Installation and Wiring
- Do not use this product in areas with gas or dust explosion hazards. Consult the battery manufacturer before use to ensure compatibility. Always follow the battery manufacturer’s safety instructions.
- Avoid contact with foreign objects or liquids. Do not touch the inverter with wet hands. Keep the product out of reach of children.
- Grounding Instructions: The inverter must be connected to a permanent grounding system to ensure compliance with local requirements and regulations. It grounding protection is suspected to be damaged, turn off the product to prevent accidental electric shock.
- To achieve optimal inverter performance, adhere to the required specifications and select appropriate cable sizes, which is crucial for proper operation.
- Carefully check that the battery voltage matches the inverter’s input DC voltage (12V). Voltage mismatches between the inverter and battery may cause severe damage.
- Reversing the positive and negative terminals between the inverter and the battery is strictly prohibited, as it will burn the inverter’s fuse.
- Avoid using excessively long battery cables, as they can cause voltage drops and reduce efficiency.
- Ensure the device is used in compliant environmental conditions. Do not operate the product in humid or dusty environments. Ensure adequate space around the product and keep ventilation openings unobstructed.
- Before starting the device, verify all connections are correct and securely fastened
- This inverter cannot be used in parallel with others and must not be connected to the public electricity grid.
- When the inverter is not in use, turn off the power and disconnect it from the system to prevent battery drain.
Transport and Storage
- Ensure all power cables are disconnected before storing or transporting the product.
- If the device is transported without its original packaging, any transport damage will not be covered.
- Store the product in a dry environment with a storage temperature range of – 10°C to 45°C.
Overview
Scope
This user manual provides product information, operation, and maintenance
guidelines for the POW-HV-EU series inverters. The POW-HV-EU series products,
developed by PowMr, are versatile inverters suitable for a wide range of
residential and commercial applications.
Intended Audience
This manual is intended for professional technicians involved in the
installation, operation, and maintenance of lithium batteries, as well as end
users seeking technical information.
Manual Usage
-
Before using the product, carefully review this user manual and keep it in a readily accessible place.
-
All information in this user manual, including images and symbols, is the property of PowMr.
Unauthorized use of any part or the entirety of this manual by non-company personnel is prohibited. -
Considering the possibility of updates and revisions to this manual, users should refer to the products included instructions as a reference. Users can obtain the latest user manual through the official website or by contacting customer service.
Product Description
Features
- Pure sine wave inverter output.
- Inverter output power up to 2500W/3500W.
- Suitable for converting 12VDC to 220V ≤ 10% AC output.
- Supports double surge output for 1 second.
- Built-in USB port with output up to 5V 2.4A.
- Built-in overload, short circuit, over-temperature, under-voltage, over-voltage, and reverse polarity protection.
- Equipped with a remote control panel for easy remote monitoring of data and status.
Basic System Architecture
The diagram below illustrates the basic application of the inverter.
- For other possible system architectures, please consult with your system integrator based on your requirements.
Product Appearance
① | Power Switch | ⑤ | USB Port |
---|---|---|---|
② | LCD Display | ⑥ | RC Output Ports |
③ | Communication Port | ⑦ | Battery Ports |
④ | Indicator Light | ⑧ | Fans |
Installation
Unpacking Inspection
Before assembly, carefully inspect the package to ensure that the items inside
are undamaged.
You should receive the following items in the package:
- Inverter device x1
- User manual x1
- Battery cables x2
- Remote control panel x1
- Dedicated communication cable x1
- Spare replacement fuses (6 PCS for 2.5K model, 8 PCS for 3.5K model)
- Battery terminal screw kit (1 pair)
Installation Tools
Prior to installation, prepare the following tools:
Installing the Device
Before choosing an installation location, consider the following points:
- Do not install the inverter on combustible building materials.
- Install it on a solid surface.
- For proper air circulation and adequate heat dissipation, leave approximately 150cm of space on both sides, the top, and the bottom of the device.
- The ambient temperature should be maintained between – 10°C and 45°C to ensure optimal operation.
- Ensure that other objects are positioned at a safe distance from the inverter surface as shown in the example diagram, to allow for proper heat dissipation and sufficient space for wiring removal.
Note: Only suitable for installation on concrete or other non-combustible
walls.
To install the unit, use 4 screws. It is recommended to use M4 or M5 screws.
Wiring
Cable Size and Breaker Specifications
Battery
Model | Gauge | Circuit Breaker Spec |
---|---|---|
POW-HV2.5K-12V-EU | 3AWG | 250R |
POW-HV3.5K-12V-EU | 2AWG | 300R |
AC Output
Model | Gauge | Circuit Breaker Spec |
---|---|---|
POW-HV2.5K-12V-EU | 13AWG | 15A |
POW-HV3.5K-12V-EU | 13AWG | 20A |
Enclosure Grounding
Please follow the diagram below to complete the grounding of the inverter
enclosure.
NOTE
- Ensure the inverter enclosure is grounded first. If the device enclosure becomes live due to a fault, grounding will quickly direct the current to the ground, preventing electric shock from contact with the live enclosure.
Battery Connection
Connect the positive and negative terminals of the battery as shown in the
diagram below. Be sure to install breakers that meet the required
specifications on the battery lines.
- First, connect the positive and negative battery cables to the battery terminal block.
- Then install the terminal cover.
NOTE
- The POW-HV-EU series inverter’s battery lines come with spare replacement fuses. Use them as needed.
- After completing the connection, carefully check if the positive and negative cables are connected correctly and if the terminals are securely fastened.
Remote Control Panel Connection
Connect the remote control panel to the inverter using the dedicated
communication cable provided in the package.
Operation
Starting the Inverter
After closing the battery circuit breaker, start the inverter using the power
switch on the inverter body or the power switch on the remote control panel.
NOTE
- The switch on the remote control panel and the switch on the inverter body are independent.
- If you start the inverter using the power switch on the inverter, you must use this switch to turn off the inverter; you cannot use the remote control panel to do so.
- Similarly, if you start the inverter using the remote control panel, you must use the remote control panel to turn it off.
Connecting Loads
- After the inverter starts normally, connect the plugs of the loads.
- Ensure all cables are properly installed and securely connected.
DANGER
- Before connecting the AC output, ensure all loads are in the off state. Do not operate while the system is live.
- Check that the cables used meet the requirements. Thin or poor-quality cables pose serious safety hazards.
Remote Control Panel Overview
Functions of the Remote Control Panel
- Remote control of the inverter’s power on/off status.
- View battery voltage through the LCD display.
- Display battery capacity.
- Display inverter status.
NOTE
- The switch on the remote control panel and the switch on the inverter body are independent. If you start the inverter using the power switch on the inverter, you must use this switch to turn off the inverter; you cannot use the remote control panel to do so.
- Similarly, if you start the inverter using the remote control panel, you must use the remote control panel to turn it off.
Protection Functions
Troubleshooting
System Maintenance
- To maintain optimal long-term performance, it is recommended to perform the following checks twice a year:
- Ensure airflow around the all-in-one machine is not obstructed; clean any dirt or debris from the heat sink.
- Inspect all exposed wires for insulation damage due to sun exposure, friction with surrounding objects, dryness, insect or rodent damage, etc. Repair or replace wires as necessary.
- Verify that indicators and displays are consistent with device operation; take corrective action for any faults or error displays.
- Check all terminal connections for corrosion, insulation damage, signs of high temperature, or burning/discoloration marks; tighten terminal screws.
- Check for dirt, nesting insects, and corrosion; clean as required.
Damage Disclaimer
The company assumes no responsibility for damage caused under the following
conditions:
- Improper use or use in unsuitable locations.
- Damage caused by operating environment temperatures exceeding specified limits.
- Unauthorized disassembly and repair of the all-in-one machine.
- Damage due to force majeure: damage occurring during transport or unloading of the all-in- one machine.
Non-Warranty Conditions
The following conditions are not covered by warranty:
- User-configured batteries.
- Equipment damage caused by improper operation according to user guidelines.
- Machine damage due to natural disasters such as fire or flood.
- Products beyond the warranty period, subject to paid repair services.
Specifications
Model | POW-HV2.5K-12V-EU | POW-HV3.5K-12V-EU |
---|---|---|
System Voltage (Input Voltage) | 12VDC | |
Output Voltage | 220VRC±10% | |
Output Waveform | Pure Sine Wave | |
Output Frequency | 50Hz | |
USB Output | 5V/2.4R | |
No-load Power Consumption | <1R | <1.5R |
Surge Capacity | ≤5000W | ≤7000W |
Efficiency | ≥85% | |
Low Voltage Warning Level | 10.5±0.3V | |
Low Voltage Cut-off Level | 9.5±0.2V | |
High Voltage Protection Level | 15.5±0.5V | |
Lo Voltage Recovery Level | 11.8±0.3V | |
High Voltage Recovery Level | 15.7±0.3V | |
Overload, Protection | 120~125% | |
Overtemperature Protection | >80℃ | |
Operating Temperature Range | -10℃~+45℃ | |
Alititude | ≤3000m | |
Dimension(LxWxH) | 352x207x85mm | 390x207x85mm |
Net weight | 4.18kg | 5.38kg |
CONTACT
SHENZHEN HEHEJIN INDUSTRIAL CO., LTD
- Tel/Fax: +86 755-28219903
- Email: support@powmr.com
- Web: www.powmr.com
- Add: Henggang Street, Longgang District, Shenzhen, Guangdong, China
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>