Connector Instruction
-
Insert the connector boot onto the cable
-
Strip outer jacket about 50mm to reveal 900-micron fibers
-
Using the label, measure from the end of the buffer and make a mark between the 250µm and 125µm section
-
Strip the buffer to the mark using the middle hole, then the small hole on the stripper in short increments
-
Cleave your fiber strand to 10mm from the mark
-
Strip the remaining 20mm of buffer using the middle hole on the stripper
-
Clean any impurities from your cable using alcohol and a lint-free cloth
-
Insert the fiber into the connector body until the strand meets resistance and bows slightly
-
Remove the connector jig
-
Lock the fiber inside the connector by pressing the amber button
-
Screw the boot onto the connector body and trim any exposed Kevlar yarn
-
To remove or re-terminate the connector, simple unscrew the boot and replace the jig