VETEK OCS-V High Resolution Digital Crane Scale User Guide

September 13, 2024
VETEK

OCS-V High Resolution Digital Crane Scale

“`html

Product Information

Specifications

  • Accuracy: Chinese GB/T 11883-2002 CIII eqv. OIML R76
  • Tare Range: 100% F.S.
  • Zero Range: 4% F.S.
  • Stable Time: 10 seconds
  • Overload Safety: 100% F.S. + 9e 120% F.S.
  • Load Battery: 18650 lithium battery
  • Battery: DC5V charger
  • Battery Life: >20 hours
  • Display: 115*41mm LED display

Product Usage Instructions

Operation and Maintenance

  • Do NOT overload the scale to avoid damaging the load cell and
    voiding the warranty.

  • Do NOT leave the load hung on the scale for extended periods as
    it can decrease accuracy and shorten the load cell’s life.

  • Inspect the shackle, hook, clips, pins, and screws regularly
    before using the scale.

  • Check the battery frequently and replace dead batteries with
    new ones promptly.

  • Rotate the load instead of the scale if needed.

  • Avoid using the scale under thunder or rain conditions.

  • Hang the scale on a shelf in a dry and well-ventilated room; do
    NOT place it directly on the ground.

  • Do NOT attempt to repair the scale yourself; contact your local
    representative for assistance.

  • Use only the original DC5V charger; do NOT use external
    chargers.

FAQ

Q: How do I change the Auto-Off Timing on the scale?

A: Press the corresponding keys as described in the User Setup
section to access the Auto-Off Timing setting. Then, use the
provided instructions to change the timing value to your desired
setting.

Q: What is the default Idle Mode Timing setting for the

scale?

A: The default Idle Mode Timing setting is 30 seconds. You can
adjust this setting using the instructions provided in the User
Setup section.

“`

OCS-V
User Guide
Manual_OCS-V_V1 ENG

High Resolution Digital Crane Scale

User Guide

For good performance and precise measurement, be careful with daily operation and maintenance.

Do NOT overload scale. This will damage loadcell and void
warranty.
Do NOT leave load hung on the scale for long. This will
decrease scale’s accuracy and shorten loadcell’s life.
Inspect shackle and hook before using. Check clips, pins and
screws regularly.
Check battery frequently. When scale runs out of power, replace
the dead batteries with new ones.
Rotate load rather than scale if needed. Do NOT use scale under thunder or rain. Hang scale on shelf in dry and well-ventilated room. Do NOT
place scale on the ground directly.
Do NOT attempt to repair scale yourself. Contact your local
representative.
Do NOT use external chargers, Use the original DC5V charger.

Specifications

Accuracy Tare Range Zero Range Stable Time Overload Safety Load Battery Battery Life Display

Chinese GB/T 11883-2002 CIII eqv. OIML R76 100% F.S. 4% F.S. 10sec 100% F.S. + 9e 120% F.S. 18650 lithium battery DC5V charger >20hour 115*41mm LED display

Page 1 of 4

High Resolution Digital Crane Scale

Op. Temp.

-10 ~ +40

User Guide

Display & Keys
Scale Keys
Key Name Function Power-on
On/Off Power-off
Zero Zero

Hold Lock/unlock

Tare Tare in/out

Remote Keys

Key

Name Function

Zero

ZeroChange digit

Tare

Tare in/outMove digit

Hold Lock or unlockConfirm &Next

Page 2 of 4

High Resolution Digital Crane Scale

Acc.

2nd functionChange digit

User Guide

Del.

2nd functionMove digit

F1

2nd function

F2

Unit Switch

Off

Long press to power off

2nd

2nd function

User Setup

Press

first then press shows.

to enter User Setup menu.

Auto-Off Timing

Press to enter Auto-Off Timing.

shows.

Press

or

to change timing value.

Auto-Off Timing can be set to: (disabled), (5min),

(10min), (15min), (30min), (60min).

Display Brightness

Press Press

br to enter Backlight Brightness. — shows.

or

to change brightness value.

Display Brightness can be set to 0-7 levels.

Press Press

Idle Mode Timing

idE to enter Idle Mode Timing.

— shows

or

to change timing value.

Page 3 of 4