7029V000 Fotobunky Sommer 7029 Instruction Manual

September 12, 2024
SOMMER

7029V000 Fotobunky Sommer 7029

Specifications:

  • Art.-Nr.: 7029V000
  • 100% MADE in EU
  • TX Sender
  • Receiver (RX)
  • Input Voltage: 12-24 Vac/dc
  • Power Consumption: Max 500 mA and 48 V ac/dc
  • IP Rating: IP55
  • Compliance: EN 60529, 2002/95/EC

Product Usage Instructions

Installation:

  1. Mount the device using the wall mounting screws provided.
  2. Connect the wires through the passage holes for proper connection.
  3. Ensure the circuit is properly aligned and secured.

Synchronization Activation/Deactivation:
To activate synchronization only on 12/24Vac, follow these steps:

  1. Set switch 1 to ON position.
  2. To deactivate synchronization, set switch 1 to OFF position.

Minimum Power Setting:
To set minimum power to avoid reflections, follow these steps:

  1. Set switch 2 to ON position.
  2. To revert to normal power setting, set switch 2 to OFF position.

Frequently Asked Questions (FAQ):

  1. Q: What is the input voltage range for the device?
    A: The device supports an input voltage range of 12-24 Vac/dc.

  2. Q: How do I activate synchronization only on 12/24Vac?
    A: Set switch 1 to the ON position to activate synchronization only on 12/24Vac. Set it to OFF to deactivate synchronization.

  3. Q: What is the maximum power consumption of the product?
    A: The product has a maximum power consumption of 500 mA and supports up to 48 V ac/dc.

Instructions and warnings

7029V000-Fotobunky-Sommer-7029-\(1\)

1 ON activate the synchronisation only 12/24
1 OFF  deactivate the synchronisation

2 ON

| maximum power maximale puissance
---|---
2 OFF|  minimum power (avoid reflections)

7029V000-Fotobunky-Sommer-7029-\(2\)

2 ON|

  • Deactivate the planing intervention time and you can use the synchronisation

---|---
1 OFF
2 OFF| Planning intervention time of 300 ms

Technical features

 power supply| Vac/dc| * 13,5 / 24
12 / 24
---|---|---
l limit power supply| | 18-35 Vdc
15-28 Vac
max. range up| m| 20
 Operating temperature| | – 10 °C
+ 60 °C
 TX power absorption e| mA| 25
RX power absorption| mA| 35
output relay contact| | max 500 mA e 48 V ac/dc
protection| IP| 55 EN 60529

EC declaration of confirmity
Art.-Nr.7029V000

complies with the following relevant provisions: 2014/30/UE, 2014/35/UE
Ernestino Bandera
Administrator
01/06/2017

EB TECHNOLOGY S.r.l.
Corso Sempione 172/5, 21052 Busto Arsizio VA Italy
posta@ebtechnology.it
www.ebtechnology.it

A bottom
B wallmount fixing screws
C holes passage spin connection
D circuit
E sphere support
F rotating block
G fixing screws rotating block
H cover
  • Open the photocell with a screwdriver between the botton and the wall.
  • • GB It is recommended: TX Micro switch 2-OFF minimum power and apply the adhesive inside the container of the RX photocell, in particular in cases of
    reflection (floors, walls, and shiny or particularly reflecting surfaces, etc). If using two pairs of photocells simultaneously, for example inside and outside a sliding gate, pay attention on the parallelism to prevent any undesired reflection phenomen.

Adhesive power Reduction RX

(Blenden)

synchronisation

  • activate the synchronisation only 12/24Vac

7029V000-Fotobunky-Sommer-7029-\(6\)

  • When you use in AC and the synchronisation is activated, the light receiver remains partially lit.

100 %
MADE in EU

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals