“`html
Technical Specifications
-
Sensitivity: 6 Adjustable Zones with sensitivity levels
0-255 -
Zone Indications: 6 Zones
-
Overhead Control Unit: All Electronics- LED, Alarm light, LED
bar graph, Control Touch padsIntegrated to eliminate wire
exposure -
Password protection: Settings 4-Digit customizable
password -
Self Diagnostics: Upon Startup/Reset Unit will
Self-Diagnose -
Battery Pack (Optional): 8-10 Hours of Backup Battery
Charge -
Warranty: 24-Month standard warranty Limited Parts/Labor
-
Interior Size: 78.74in(H) x 32in(W) x 19.69in(D)
-
Exterior Size: 86.61in(H) x 37.2in(W) x 22.83in(D)
-
Shipping weight: 2 Pieces per unit – Legs:123.46lbs
Head:30.86lbs -
Temperatures: -20C to 60C Operating, -20C to 50C Storing
-
Power: Weatherproofing IP55 Water/Dust resistant
Product Features
General Information
Regional Sensitivity: The maximum sensitivity
can detect metal content as small as a paper clip, in
self-regulation between 0-255 sensitivity detection requirements
may need to be adjusted. Be sure to determine the items you are
looking for beforehand and remove keys, jewelry, belt buckles, and
steel toe boots to prevent false alarms. Also make sure that the
unit is at least 4 feet from any metal frame door or revolving
door.
Waterproof: Made of PVC synthetic materials,
the unit is waterproof for mild outdoor usage.
Smart Statistics: Intelligent traffic and alarm
counting function; can automatically detect the number of passing
individuals and the number of alarms that have gone off.
Anti-Interference Ability: Digital, analog, and
left and right balanced technology help in preventing false alarms
and false negatives, and greatly improve the anti-jamming
capability.
Safety Protection: Double password protected,
allowing only authorized personnel operation and access. Multiple
passwords allow for better security parameters. Parameter settings
are automatically stored without interrupting power supply
protection, both safe and convenient.
Product Usage Instructions
1. Setting Up the Walk-Through Metal Detector
Ensure the walk-through metal detector is placed on a flat
surface in the desired location. Connect the power supply according
to the manufacturer’s instructions.
2. Adjusting Sensitivity Levels
Use the control touch pads on the overhead control unit to
adjust the sensitivity levels of the detector. Depending on your
requirements, set the sensitivity levels between 0-255 for each of
the six zones.
3. Operating the Detector
Once the detector is set up and sensitivity levels are adjusted,
instruct individuals to walk through the detector one at a time.
Monitor the LED indicators and alarm lights for any alerts.
FAQ
Q: How can I reset the password on the walk-through metal
detector?
A: To reset the password, follow the manufacturer’s instructions
for password customization. Typically, there is a reset option that
allows you to set a new password.
Q: Can the walk-through metal detector be used outdoors?
A: Yes, the walk-through metal detector is made of waterproof
materials and can be used for mild outdoor applications.
Q: What should I do if there are false alarms triggered by the
detector?
A: Ensure that individuals passing through have removed any
metal items on their person such as keys, jewelry, belt buckles, or
steel toe boots. Additionally, check for any interference from
nearby electronic devices or moving metal objects that may be
causing false alarms.
“`
MD-6ADA USER MANUAL
1
MEDICAL SAFETY
Metal Defender makes every effort to ensure its products are safe for use.
Extensive research by Metal Defender has produced no information which would
indicate that its products have any adverse effects on medical implants,
pregnancy, recording media or magnetic strips. Metal Defender makes every
effort to cooperate with medical device manufacturers and to communicate with
agencies such as the United States Food and Drug Administration and Health
Canada as a means of assuring product safety. The electromagnetic fields
produced by Metal Defender products are similar to those encountered in the
daily environment and meet U. S. and International standards for
electromagnetic emissions. Metal Defender recognizes that certain medical
devices may have additional requirements which may require special care. Any
recommendations or directives issued by personal physicians or medical device
manufacturers should be followed. If, for any reason, (e.g. doctors orders,
etc.), a patron objects to being scanned with a metal detector, it is
recommended that alternative procedures be used. The following should be
considered when developing a security checkpoint screening plan.
·Traffic Flow – Traffic flow should remain consistent and encourage
unrestricted traffic flow as a means of minimizing the time a person remains
within the archway of a walk- through metal detector.
·Alternative Screening – Alternative screening methods such as scanning with a
handheld metal detector, hand searching or denial of access should be clearly
defined in checkpoint screening procedures as approved alternatives to
screening with the walk- through metal detector.
·Personnel Training – Security screening personnel should be instructed in the
care of persons with special medical needs and use of alternative screening
methods that meet the requirements of medical practitioners or medical device
manufacturers
2
PLEASE READ THE FOLLOWING INSTRUCTION CAREFULLY BEFORE OPERATON
Regarding to how to how to use the machine correctly and safely, please
attention to the following instructions. make sure you have read it before
operation. 1. It’s available for both indoor and outdoor use, please use
canopy to protect it against rain. 2. Choose the smooth and stable
installation place, don’t touch the detector during security checking to avoid
false alarm. 3. Make sure there’s no big metal object or strong magnetic field
around the detector within 2 meters. 4. Keep the detector far from the power
line and communication cable. 5. Detector probe must not install in high
temperature or wet circumstance. 6. Do not disassemble the control units
except the professional technician. 7. Please wait l minute for its self-
diagnosing when machine start. 8. We advise to have a power cord on the
ceiling, easier to connect to the detector. 9. Follow the user manual and make
sure the right wire connection when machine start.
INTERFERENCE
The interference during the walk through metal detector working,are mainly as
follow:
Electronic Jamming Working frequency for the Walk Through metal detector is
4KHz-8KHz. around the work environment should exclude the electronic products
that have the almost similar working frequency such as generator, TV etc.
Moving metal objects Interference The Walk Through metal detector will be
interfered by the moving metal objects, around the work environment should not
have turnstile and from vehicle etc. big moving metal objects.
Interference Between Products And Products During using 2 pieces or more Walk
Through metal,should avoid using the same frequency(the work frequency can be
seen on the packing box),the minimum distance between two doors should be
above 0.5m to avoid the mutual interference for the Walk Through metal
detectors.
3
Technical Specifications
Metal Defender’s MD-6A Walk-through Metal Detector provides pinpoint accuracy
and discrimination features. This detector is effective in all environments
including but not limited to airports, government buildings, correctional
facilities, and sports venues. While being cost effective it also provides the
same security that professionals worldwide receive from other brands.
Sensitivity
6 Adjustable Zones with sensitivity levels 0-255
Zone Indications
6 Zones
Overhead Control Unit
All Electronics- LED, Alarm light, LED bar graph, Control Touch padsIntegrated to eliminate wire exposure
Password protection
Settings 4- Digit customizable password
Self Diagnostics
Upon Startup/Reset Unit will Self-Diagnose
Battery Pack (Optional)
8-10 Hours of Backup Battery Charge
Warranty
24-Month standard warranty Limited Parts/Labor
Interior Size
78.74in(H)x32in(W)x19.69in(D)
Exterior Size
86.61in(H)x37.2in(W)x22.83in(D)
Shipping weight
2 Pieces per unit – Legs:123.46lbs Head:30.86lbs
Temperatures
-20C to 60C Operating-20C to 50C Storing
Power
110-230VAC ± 10%
Weatherproofing
IP55 Water/Dust resistant
4
Product Features
· Alarm Display, LED lights determine metal objects on both side · Built in
power supply · Waterproof for mild outdoor usage
General Information
Regional Sensitivity: The maximum sensitivity can detect metal content as
small as a paper clip, in self-regulation between 0-255 sensitivity detection
requirements may need to be adjusted. Be sure to determine the items you are
looking for beforehand and remove keys, jewelry, belt buckles, and steel toe
boots to prevent false alarms. Also make sure that the unit is at least 4 feet
from any metal frame door or revolving door.
Waterproof: Made of PVC synthetic materials, the unit is waterproof for mild
outdoor usage.
Smart Statistics: Intelligent traffic and alarm counting function; can
automatically detect the number of passing individuals and the number of
alarms that have gone off.
Anti-Interference Ability: Digital, analog, and left and right balanced
technology help in preventing false alarms and false negatives, and greatly
improve the anti-jamming capability.
Safety Protection: Double password protected, allowing only authorized
personnel operation and access. Multiple passwords allow for better security
parameters. Parameter settings are automatically stored without interrupting
power supply protection, both safe and convenient.
Electromagnetic Radiation: EMC electromagnetic radiation standards; use of
weak magnetic field technology, safe for pregnant women, cell phones, film,
video tapes and other sound equipment.
Installation: This series metal detector has an integrated design, which
allows for easy installation or removal within 10 minutes.
Field of Use: Airport, schools, concert venues, events, railway stations,
docks, entertainment facilities, prisons, courts, government departments,
factories, examination room, shopping malls, community channels, security
check, and prohibited items inspection areas.
5
Installation Instructions
Please read through the following instructions to properly install, program,
and adjust the sensitivity of the Metal Defender walk-through metal detector.
1. Open the boxes and take out the 3 main pieces Left door panel, Right
door panel, and control unit. Place all on the Styrofoam in the position below
to properly secure the 3 pieces to form the frame of the unit (see diagram
below). The LED display on the control unit should be in the upright position
facing you. Each probe is identified with an “L” or “R”. Make sure the “L” or
“R” inside the control unit matches the corresponding probe. 2. Take the 8
bolts and nuts in the bag and make sure that they are pushed through each
screw hole on the probes and than through the holes in the control unit. 3.
Once you have the 8 bolts securely in place with the probes and control unit,
take the 8 nuts and tighten securely with the included Allan Wrench (you may
need a wrench to hold nut in place when tightening) 4. Each leg has 2 sets of
plugs, a round connector and a square power supply connector The Connectors
and the Ports are keyed by shape, so they will only go in one way. Carefully
lock them into place. This is the Power and communication supply from the CPU
to each of the probes/legs. Take care, but be sure to insert fully. (If not
inserted properly the LED’s will not work). Finally, Plug the DC connector
inside the main board to the corresponding leg/probe where the AC plug is
attached from outside the leg/probe.
6
5. Lock the cover of the control unit case with 4 bolts to prevent opening
while transporting. 6. Please have 2 people lift the detector vertically so it
is secure and standing upright on the bottom feet. Move the detector to where
you will want to install it. 7. Plug the AC plug into an electric outlet. Turn
the orange power button on. Your unit should light up and sound off one time.
If it does , your unit is up and running. You can adjust sensitivity for the
entire unit or for each of the individual zones (see below).
Understanding the Zones
A: Alarm Zone Locations There are 6 unique and precise zones that will
monitor and attempt to detect for metal each time somebody walks through. Each
zone can be individually programmed for a specific sensitivity. Each
individual zone will light up when metal is detected and a beep will sound to
alert security as to where the metal is located. B: Infrared Sensor Records
each person that passes by.
7
Understanding the Panel
PASS CNT: Will count the number of people that pass through the detector ALARM
CNT: Will count the number of times the detector found metal Enter: startup
and close,enter the option.
“”: left option, return, parameters to be the left or upward options. “”:
right option, parameters to be the right or downward options. “”: upward
option,parameters to be incremental adjustment. “”: downward option,
parameters to be reduction adjustment.
The specific function, please reference keypad operating instructions in the
relative setting pages.
8
Debugging
TURN ON After finishing cable connection, press the orange button the door
panel and then Press the “ENTER” in the control unit for 5s to turn on the
detector. ENTER IN TO SETTING INTERFACE Press “ENTER” to input password so as
to enter in to setting interface. Factory Password: 9000 0000. Universal
Password: 8888 8888
SENSITIVITY SETTING Press button “” or “” to opt the setting, the panel
displays H–0 200.
H–0: Overall sensitivity (0-255) H–1: Sensitivity of zone 1 (bottom)(0-255)
H–2: Sensitivity of zone 2 (0-255) H–3: Sensitivity of zone 3 (0-255) H–4:
Sensitivity of zone 4 (0-255) H–5: Sensitivity of zone 5 (0-255) H–6:
Sensitivity of zone 6 (top)(0-255) Press “ENTER” key enter into adjusting,
press “” or “” to adjust the sensitivity value, press “” to exit adjusting the
whole sensitivity, after adjusting the sensitivity value, press “ENTER” to
save and return back to the setting interface. FREQUENCY SETTING Press button
“” or “” to opt the setting, the panel displays F–1, 7800.
Press “ENTER” key enter into adjusting, press “” or “” to adjust the
frequency, press “” to exit adjusting, after adjusting the frequency value,
press “ENTER” to save and return back to setting interface.
9
ALARM SETTING Press button “” or “” to opt the setting, the panel displays
A–1, 200.
A–1: Alarm Volume (0-255) A–2: Alarm Duration (1-25) A–3: Alarm Tones (0-10)
Press “ENTER” key enter into adjusting, press “” or “” to adjust the alarm
volume/ alarm duration / alarm tones, press “” to exit adjusting, after
adjusting the alarm, press “ENTER” to save and return back to setting
interface. PASSWORD SETTING Press button “” or “” to opt the setting, the
panel displays P–1, 1234.
press “” or “” to increase/reduce the number, press”” or “” to make the left
and right optional among the numbers, after the password is advised ready and
then press “ENTER” to save the new password, Then all is setting ready and the
detector enter into normal working state.The specific method for setting
passing word is as follow (only 4 numbers for password) as the left 4 numbers
are old password, the right 4 numbers need to be set and will be used, so only
put into the left 4 numbers correct and then the right 4 new password numbers
can be be set successful.
10
FAQ
What if I cannot put in a location where the signal strength indicator will
not go off? If you cannot find a fitting location where the signal strength
indicator will not turn off, that is ok, it will just make the unit less
sensitive. It will still pick up metal from passer bys, but the sensitivity
levels will have to be adjusted higher. A good indication is to adjust your
sensitivity 2 points higher for every LED that remains lighted on the signal
strength indicator. If your desired sensitivity setting is 70, and if your
unit’s signal strength indicator continuously has 2 LED’s lit at all times,
adjust your sensitivity to 74 to accommodate for the surrounding metal around
the unit. Sometimes, even moving the unit a few inches or even 90 degrees can
help decrease the LED indicator.
What is the right sensitivity setting for me? The best way to determine what
sensitivity setting would work best for you is to start on the lowest
sensitivity setting 01 and find an article of metal that you wish to pick
up. Walk through with the object and increase gradually until the detector
picks up the metal. Start with a smaller piece of metal you wish to detect and
work from there. If set for smaller traces of metal, the unit will alarm for
larger pieces too. (The unit is defaulted at a 180 sensitivity).
Examples of minimum sensitivities settings and what will set unit off: 240
Paper clip, 210 Coin cell batteries, 200 Ring, Zippers, Buttons 180 Box
cutter, 180 Gun / Knife, 150 Cell Phone, 140 Belt Buckles, Set of Keys
I set up my unit, but it will not sound when I walk through with metal? Always
remember that the control panel with the buttons and LED should always be
facing away from the people walking through. Continue with the flowchart and
make sure that your alarm time length is not set at A 3-00. If set at A3-00,
the unit is on mute mode and will not give an audio alarm when metal is
detected. Secondly, please make sure that the internal AC plug is plugged into
the panel where the internal power source is plugged in. Also, please make
sure that the correct serial ports inside the head unit are securely fastened
in the proper locations. Last, replace the buzzer.
There seems to be a lot of alarm detections occurring, more than we want or
expected. Why is this? Before implementing a metal detector into your
security, one must have a plan as to how the equipment is going to best work
for them. The best way is to consult who is going to be monitoring the unit
and what is the purpose of the unit. For example, if you are looking to catch
people stealing small computer IC chips in their pockets, you are going to
need a high sensitivity to detect them. One must have a plan as to which items
are needed to be put aside before walking through. If you are not sure, or
would like a product specialist to assist creating a plan, feel free to
contact us at 815-467-6464.
The passerby units are not adjusting or are continuously increasing. What
should I do? The black circular discs on the inside of the panels are the
infrared sensors. These pick up when a person walks through the unit. If the
unit is not picking up the passerbys, the sensors may have fingerprints or
dirt on them. With a cloth towel with rubbing alcohol or window cleaner, rub
around the sensor to clean. Also, please check and make sure that the cables
are securely fastened to the metal detector leg panels and PC board. If this
connection is loose, the unit may not work.
11
SUGGESTED SINGLE LANE CONFIGURATION SUGGESTED MULTI-LANE CONFIGURAT
12
BRIEF MAINTENANCE
1. Can’t Start The Machine 1) Check whether power sockets properly. 2) Check
whether the power switch is on. 3) Check the fuse blew out (Only for Walk
Through model).
2. Can’t Account Passengers 1) Don’t work in the strong sunlight as it use
infrared sensor. 2) Check the left and right infrared sensor probe whether in
parallel.
3. Alarm Without Metal 1) First, exclude all the metal in ourself and go
through the detector. Find out which zones alarm and low down the zone
sensitivity accordingly until it is not alarm. 2) Check whether have
interference nearby such as big movable machine, high-power equipment. 3)
Check whether there are similar products nearby, if so change the
frequency(Original frequency show on the package carton box). 4) Make sure no
big wind and smooth around installation place.
4. With Metal But No Alarm 1) Follow the user manual and increase the zone
sensitivity and total sensitivity. 2) The factory default setting can detect a
coin diameter 25mm. Make sure the metal size is bigger,if not adjust the
sensitivity accordingly.
5.Single Zone No Alarm Make higher sensitivity then test again.Change the
corresponding zone signal collection card if problem is the same in highest
sensitivity.
6. Unnormal Communications 1) Follow the user manual and confirm whether is
the problem of left sensor or right sensor. 2) When confirmed which door frame
have communication problems, pull out its probe and reinsert for several
times,then test again. If problem the same, then replace the corresponding
signal collection card, main board and wire step by step until confirm the
problems.
7. Whole Machine Non-inductivity Check whether the communication is ok,
follow above 6 steps. If communication is ok, replace the mainboard or signal
board step by step.
8. LCD Screen Problems, LED Bar Graph Not Lighting,Buttons Not Working 1)
Replace the parts from other Walk Through metal detector to find the failure
parts
13
2 YEAR WARRANTY INFORMATION
Metal Defender warrants that each piece of security equipment manufactured by
Metal Defender is protected by the following limited parts and labor warranty
for a period of 24 (twenty-four) months (the “Warranty”). During this 24-month
period Metal Defender will inspect and evaluate all equipment returned to its
authorized repair station or factory to determine if the equipment meets Metal
Defender’s performance specifications. Metal Defender will repair or replace
at no charge to the owner all parts determined faulty. This Warranty does not
cover batteries nor any and all failures caused by abuse, tampering, theft,
failure due to weather, battery acid or other contaminants and equipment
repairs made by an unauthorized party. THIS WARRANTY IS EXPRESSLY IN LIEU OF
ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING THE WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THE BUYER ACKNOWLEDGES
THAT ANY ORAL STATEMENTS ABOUT THE MERCHANDISE DESCRIBED IN THIS CONTRACT MADE
BY SELLERS ‘ REPRESENTATIVES, IF ANY SUCH STATE-MENTS WERE MADE, DO NOT
CONSTITUTE WARRANTIES, SHALL NOT BE RELIED UPON BY THE BUYER, AND ARE NOT A
PART OF THIS CONTRACT FOR SALE. THE ENTIRE CONTRACT IS EMBODIED IN THIS
WRITING. THIS WRITING CONSTITUTES THE FINAL EXPRESSION OF THE
PARTIES’AGREEMENT AND IS A COMPLETE AND EXCLUSIVE STATEMENT OF THE TERMS OF
THIS AGREEMENT. The parties agree that the Buyers’ sole and exclusive remedy
against Seller shall be for the repair and replacement of defective parts. The
Buyer agrees that no other remedy (including, but not limited to, incidental
or consequential damages for lost sales, lost profits, injury to person or
property) shall be available to him.