METAL DEFENDER MD-H Walk Through Metal Detector User Manual
- September 19, 2024
- METAL DEFENDER
Table of Contents
MD-H Walk Through Metal Detector
“`html
Technical Specifications
-
Sensitivity: 5 Adjustable Zones with sensitivity levels
0-255 -
Zone Indications: 5 Zones
-
Overhead Control Unit: All Electronics- LED, Alarm light, LED
bar graph, Control Touch padsIntegrated to eliminate wire
exposure -
Password protection: Settings 4-Digit customizable
password -
Self Diagnostics: Upon Startup/Reset Unit will
Self-Diagnose -
Warranty: 24-Month standard warranty Limited Parts/Labor
-
Dimension: 78.74in(H) x 15.75in(W) x 5.51in(D)
-
Shipping weight: 1 Pieces per unit – 88.18 lbs
-
Temperatures: -20C to 60C Operating, -20C to 50C Storing
-
Power: Weatherproofing, IP55 Water/Dust resistant
Product Features
General Information
-
Regional Sensitivity: The maximum sensitivity can detect metal
content as small as a coin. Adjust sensitivity levels between 0-255
as needed. -
Preparation: Remove keys, jewelry, belt buckles, and steel toe
boots before operation to prevent false alarms. -
Distance: Ensure the unit is at least 4 feet away from any
metal frame door or revolving door. -
Waterproof: Made of PVC synthetic materials, suitable for mild
outdoor usage. -
Smart Statistics: Intelligent traffic and alarm counting
function for automatic detection of passing individuals and alarms
triggered. -
Anti-Interference Ability: Utilizes digital, analog, and
left-right balanced technology to prevent false alarms and improve
anti-jamming capability.
Product Usage Instructions
Interference Handling
Electronic Jamming: Avoid electronic products
with similar working frequencies (4KHz-8KHz) near the detector like
generators or TVs.
Moving Metal Objects Interference: Keep away
from large moving metal objects like turnstiles or vehicles to
prevent interference.
Interference Between Products: Maintain a
minimum distance of above 0.5m between two detectors to avoid
mutual interference.
Operation Guidelines
-
Ensure the unit is powered on and self-diagnosed upon
startup. -
Set the sensitivity levels based on the items being
detected. -
Use password protection for security settings.
-
Maintain the recommended temperature range during operation and
storage. -
Regularly check for any interference and adjust the detector
setup accordingly.
FAQ
Q: What should I do if the detector triggers false alarms
frequently?
A: Check for any nearby sources of interference
such as electronic devices or moving metal objects. Adjust the
sensitivity levels as needed and ensure proper distance from
potential interference sources.
“`
MD-H USER MANUAL
1
MEDICAL SAFETY
Metal Defender makes every effort to ensure its products are safe for use.
Extensive research by Metal Defender has produced no information which would
indicate that its products have any adverse effects on medical implants,
pregnancy, recording media or magnetic strips. Metal Defender makes every
effort to cooperate with medical device manufacturers and to communicate with
agencies such as the United States Food and Drug Administration and Health
Canada as a means of assuring product safety. The electromagnetic fields
produced by Metal Defender products are similar to those encountered in the
daily environment and meet U. S. and International standards for
electromagnetic emissions. Metal Defender recognizes that certain medical
devices may have additional requirements which may require special care. Any
recommendations or directives issued by personal physicians or medical device
manufacturers should be followed. If, for any reason, (e.g. doctors orders,
etc.), a patron objects to being scanned with a metal detector, it is
recommended that alternative procedures be used. The following should be
considered when developing a security checkpoint screening plan.
· Traffic Flow – Traffic flow should remain consistent and encourage
unrestricted traffic flow
as a means of minimizing the time a person remains within the archway of a
walk- through metal detector.
· Alternative Screening – Alternative screening methods such as scanning with
a handheld
metal detector, hand searching or denial of access should be clearly defined
in checkpoint screening procedures as approved alternatives to screening with
the walk- through metal detector.
· Personnel Training – Security screening personnel should be instructed in
the care of
persons with special medical needs and use of alternative screening methods
that meet the requirements of medical practitioners or medical device
manufacturers
2
PLEASE READ THE FOLLOWING INSTRUCTION CAREFULLY BEFORE OPERATON
Regarding to how to how to use the machine correctly and safely, please
attention to the following instructions. make sure you have read it before
operation. 1. It’s available for both indoor and outdoor use, please use
canopy to protect it against rain. 2. Choose the smooth and stable
installation place, don’t touch the detector during security checking to avoid
false alarm. 3. Make sure there’s no big metal object or strong magnetic field
around the detector within 2 meters. 4. Keep the detector far from the power
line and communication cable. 5. Detector probe must not install in high
temperature or wet circumstance. 6. Do not disassemble the control units
except the professional technician. 7. Please wait l minute for its self-
diagnosing when machine start. 8. We advise to have a power cord on the
ceiling, easier to connect to the detector. 9. Follow the user manual and make
sure the right wire connection when machine start.
INTERFERENCE
The interference during the walk through metal detector working,are mainly as
follow:
Electronic Jamming
Working frequency for the Walk Through metal detector is 4KHz-8KHz. around the
work environment should exclude the electronic products that have the almost
similar working frequency such as generator, TV etc.
Moving metal objects Interference
The Walk Through metal detector will be interfered by the moving metal
objects, around the work environment should not have turnstile and from
vehicle etc. big moving metal objects.
Interference Between Products And Products
During using 2 pieces or more Walk Through metal,should avoid using the same
frequency(the work frequency can be seen on the packing box),the minimum
distance between two doors should be above 0.5m to avoid the mutual
interference for the Walk Through metal detectors.
3
Technical Specifications
Metal Defender’s MD-H Walk-through Metal Detector provides pinpoint accuracy
and discrimination features. This detector is effective in all environments
including but not limited to airports, government buildings, correctional
facilities, and sports venues. While being cost effective it also provides the
same security that professionals worldwide receive from other brands.
Sensitivity
5 Adjustable Zones with sensitivity levels 0-255
Zone Indications
5 Zones
Overhead Control Unit
All Electronics- LED, Alarm light, LED bar graph, Control Touch padsIntegrated to eliminate wire exposure
Password protection
Settings 4- Digit customizable password
Self Diagnostics
Upon Startup/Reset Unit will Self-Diagnose
Warranty
24-Month standard warranty Limited Parts/Labor
Dimension
78.74in(H)x15.75in(W)x5.51in(D)
Shipping weight
1 Pieces per unit – 88.18 lbs
Temperatures
-20C to 60C Operating-20C to 50C Storing
Power
110-230VAC ± 10%
Weatherproofing
IP55 Water/Dust resistant
4
Product Features
· Alarm Display, LED lights determine metal objects on both side · Built in
power supply · Waterproof for mild outdoor usage
General Information
Regional Sensitivity: The maximum sensitivity can detect metal content as
small as a coin, in self-regulation between 0-255 sensitivity detection
requirements may need to be adjusted. Be sure to determine the items you are
looking for beforehand and remove keys, jewelry, belt buckles, and steel toe
boots to prevent false alarms. Also make sure that the unit is at least 4 feet
from any metal frame door or revolving door.
Waterproof: Made of PVC synthetic materials, the unit is waterproof for mild
outdoor usage.
Smart Statistics: Intelligent traffic and alarm counting function; can
automatically detect the number of passing individuals and the number of
alarms that have gone off.
Anti-Interference Ability: Digital, analog, and left and right balanced
technology help in preventing false alarms and false negatives, and greatly
improve the anti-jamming capability.
Safety Protection: Double password protected, allowing only authorized
personnel operation and access. Multiple passwords allow for better security
parameters. Parameter settings are automatically stored without interrupting
power supply protection, both safe and convenient.
Electromagnetic Radiation: EMC electromagnetic radiation standards; use of
weak magnetic field technology, safe for pregnant women, cell phones, film,
video tapes and other sound equipment.
Installation: This series metal detector has an integrated design. Plug Play.
NOTES: When you set up two units together, please set them at the distance of
80cm.
Field of Use: Airport, schools, concert venues, events, railway stations,
docks, entertainment facilities, prisons, courts, government departments,
factories, examination room, shopping malls, community channels, security
check, and prohibited items inspection areas.
5
Installation Instructions
Please read through the following instructions to properly install, program,
and adjust the sensitivity of the Metal Defender walk-through metal detector.
1. Open the boxes and take out the main body and the cablesg. 2. If install
two units. Please install them at a distance of 80+cm. 3. Plug the AC plug
into an electric outlet. Turn the orange power button on. Your unit should
light ue. If it does, your unit is up and running. You can adjust sensitivity
for the entire unit or for each of the individual zones (see below).
Understanding the Zones
A: Alarm Zone Locations There are 5 unique and precise zones that will
monitor and attempt to detect for metal each time somebody walks through. Each
zone can be individually programmed for a specific sensitivity. Each
individual zone will light up when metal is detected and a beep will sound to
alert security as to where the metal is located. B: Infrared Sensor Records
each person that passes by.
6
Understanding the Panel
IN: Will count the number of people that pass through the detector ALARM: Will
count the number of times the detector found metal Enter: startup and close,
enter the option. “”: left option, return, parameters to be the left or upward
options. “”: right option, parameters to be the right or downward options. “”:
upward option,parameters to be incremental adjustment. “”: downward option,
parameters to be reduction adjustment. The specific function, please reference
keypad operating instructions in the relative setting pages.
7
Debugging
TURN ON After finishing cable connection, press the orange button the door
panel to turn on the detector. ENTER IN TO SETTING INTERFACE Press “ENTER” to
input password so as to enter in to setting interface. Factory Password:
000000 Universal Password: 888888
ALARM SETTING Press button”ENTER” to enter into the Alarm setting interface as
below:
Press button”” or ” to opt the setting. Press button “” or “” to adjust the
value. Press button “ENTER” to save and exit. SENSITIVITY SETTING Press
button”ENTER” to enter into the Sensitivity setting interface as below:
Press button”” or ” to opt the setting. Press button “” or “” to adjust the
value. Base Value is for overall sensitivity from 0-255. 1 ZONE VAL:
Sensitivity of zone 1 (0-255)
8
2 ZONE VAL: Sensitivity of zone 2 (0-255) 3 ZONE VAL: Sensitivity of zone 3
(0-255) 4 ZONE VAL: Sensitivity of zone 4 (0-255) 5 ZONE VAL: Sensitivity of
zone 5 (0-255) 6 ZONE VAL: Sensitivity of zone 6 (set 000) The sensitivity of
area 6 is for extended use, and the unused sensitivity of this area is set to
000. Press button “” or “” to turn on/down sensitivity. After setting, press
button “ENTER” to save exit. FREQUENCY SETTING Press button “ENTER” into the
Frequency setting interface. Frequency range: 000 — 099.
Press button”” or ” to opt the setting. Press button “” or “” to adjust the
value After setting, press button “ENTER” to save exit.
SYSTEM SETTING Press button “ENTER” into the IR setting interface.
1. TIME SET: YEAR, MONTH, DAY, CLOCK 2. DISPLAY: Backlight Time: 0-99s 3.
SYSTEM ADJUST: 1) Pass Speed Adjust: 0-100 person/min 2) System Check. (a. LED
Check) (b. Sound Check) 3) Factory Reset
9
4.PASSWORD MIDEFY Press button “” or “” to adjust the value.
After setting, opt “EXIT” Press “ENTER” to exit. Radar module distance
setting: The function of the radar module is to count the number of people
through the normal passage of the human body, and perform metal detection to
trigger the alarm. Enter password 686868, press the up/down key to set the
number, and press the “ENTER” to exit. The smaller the number, the farther the
distance is. The default value is 17. Enter the password 100001 to enable the
dual radar mode. Enter the password 100002, and then turn off the power and
power on again, indicating that the dual radar working mode is turned off
before and after.
Press button “” or “” to adjust the value. After setting, press button “ENTER”
to save exit.
QUICK SETTING
1. Put up the metal detector. 2. Cover the IR sensor to see if there is any
interference or false alarm. 3.Turn down the Sensitivity of overall or change
the frequency if all the zones alarm. 4. If you set up two units together,
please put them at a distance of 80cm, and then set them one by one. When you
are setting the unit1, please turn off unit2. After setting them well, please
leave them several mins for fitting with each other. If there is still false
alarm from the zone, turn down the sensitivity or change the frequency
10
FAQ
What if I cannot put in a location where the signal strength indicator will
not go off?
If you cannot find a fitting location where the signal strength indicator will
not turn off, that is ok, it will just make the unit less sensitive. It will
still pick up metal from passer bys, but the sensitivity levels will have to
be adjusted higher. A good indication is to adjust your sensitivity 2 points
higher for every LED that remains lighted on the signal strength indicator. If
your desired sensitivity setting is 70, and if your unit’s signal strength
indicator continuously has 2 LED’s lit at all times, adjust your sensitivity
to 74 to accommodate for the surrounding metal around the unit. Sometimes,
even moving the unit a few inches or even 90 degrees can help decrease the LED
indicator.
What is the right sensitivity setting for me?
The best way to determine what sensitivity setting would work best for you is
to start on the lowest sensitivity setting 01 and find an article of metal
that you wish to pick up. Walk through with the object and increase gradually
until the detector picks up the metal. Start with a smaller piece of metal you
wish to detect and work from there. If set for smaller traces of metal, the
unit will alarm for larger pieces too. (The unit is defaulted at a 180
sensitivity).
Examples of minimum sensitivities settings and what will set unit off:
240 Paper clip, 210 Coin cell batteries, 200 Ring, Zippers, Buttons 180
Box cutter, 180 Gun / Knife, 150 Cell Phone, 140 Belt Buckles, Set of
Keys
I set up my unit, but it will not sound when I walk through with metal?
Always remember that the control panel with the buttons and LED should always
be facing away from the people walking through. Continue with the flowchart
and make sure that your alarm time length is not set at A 3-00. If set at
A3-00, the unit is on mute mode and will not give an audio alarm when metal is
detected. Secondly, please make sure that the internal AC plug is plugged into
the panel where the internal power source is plugged in. Also, please make
sure that the correct serial ports inside the head unit are securely fastened
in the proper locations. Last, replace the buzzer.
There seems to be a lot of alarm detections occurring, more than we want or
expected. Why is this?
Before implementing a metal detector into your security, one must have a plan
as to how the equipment is going to best work for them. The best way is to
consult who is going to be monitoring the unit and what is the purpose of the
unit. For example, if you are looking to
11
catch people stealing small computer IC chips in their pockets, you are going
to need a high sensitivity to detect them. One must have a plan as to which
items are needed to be put aside before walking through. If you are not sure,
or would like a product specialist to assist creating a plan, feel free to
contact us at 815-467-6464. The
passerby units are not adjusting or are continuously increasing. What should I
do? The black circular discs on the inside of the panels are the infrared
sensors. These pick up when a person walks through the unit. If the unit is
not picking up the passerbys, the sensors may have fingerprints or dirt on
them. With a cloth towel with rubbing alcohol or window cleaner, rub around
the sensor to clean. Also, please check and make sure that the cables are
securely fastened to the metal detector leg panels and PC board. If this
connection is loose, the unit may not work.
12
BRIEF MAINTENANCE
1. Can’t Start The Machine 1) Check whether power sockets properly. 2) Check
whether the power switch is on. 3) Check the fuse blew out (Only for Walk
Through model).
2. Can’t Account Passengers 1) Don’t work in the strong sunlight as it use
infrared sensor. 2) Check the left and right infrared sensor probe whether in
parallel.
3. Alarm Without Metal 1) First, exclude all the metal in ourself and go
through the detector. Find out which zones alarm and low down the zone
sensitivity accordingly until it is not alarm. 2) Check whether have
interference nearby such as big movable machine, high-power equipment. 3)
Check whether there are similar products nearby, if so change the
frequency(Original frequency show on the package carton box). 4) Make sure no
big wind and smooth around installation place.
4. With Metal But No Alarm 1) Follow the user manual and increase the zone
sensitivity and total sensitivity. 2) The factory default setting can detect a
coin diameter 25mm. Make sure the metal size is bigger,if not adjust the
sensitivity accordingly.
5.Single Zone No Alarm Make higher sensitivity then test again.Change the
corresponding zone signal collection card if problem is the same in highest
sensitivity.
6. Unnormal Communications 1) Follow the user manual and confirm whether is
the problem of left sensor or right sensor. 2) When confirmed which door frame
have communication problems, pull out its probe and reinsert for several
times,then test again. If problem the same, then replace the corresponding
signal collection card, main board and wire step by step until confirm the
problems.
7. Whole Machine Non-inductivity Check whether the communication is ok,
follow above 6 steps. If communication is ok, replace the mainboard or signal
board step by step.
8. LCD Screen Problems, LED Bar Graph Not Lighting,Buttons Not Working 1)
Replace the parts from other Walk Through metal detector to find the failure
parts
13
2 YEAR WARRANTY INFORMATION
Metal Defender warrants that each piece of security equipment manufactured by
Metal Defender is protected by the following limited parts and labor warranty
for a period of 24 (twenty-four) months (the “Warranty”). During this 24-month
period Metal Defender will inspect and evaluate all equipment returned to its
authorized repair station or factory to determine if the equipment meets Metal
Defender’s performance specifications. Metal Defender will repair or replace
at no charge to the owner all parts determined faulty. This Warranty does not
cover batteries nor any and all failures caused by abuse, tampering, theft,
failure due to weather, battery acid or other contaminants and equipment
repairs made by an unauthorized party. THIS WARRANTY IS EXPRESSLY IN LIEU OF
ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING THE WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THE BUYER ACKNOWLEDGES
THAT ANY ORAL STATEMENTS ABOUT THE MERCHANDISE DESCRIBED IN THIS CONTRACT MADE
BY SELLERS’ REPRESENTATIVES, IF ANY SUCH STATE-MENTS WERE MADE, DO NOT
CONSTITUTE WARRANTIES, SHALL NOT BE RELIED UPON BY THE BUYER, AND ARE NOT A
PART OF THIS CONTRACT FOR SALE. THE ENTIRE CONTRACT IS EMBODIED IN THIS
WRITING. THIS WRITING CONSTITUTES THE FINAL EXPRESSION OF THE PARTIES’
AGREEMENT AND IS A COMPLETE AND EXCLUSIVE STATEMENT OF THE TERMS OF THIS
AGREEMENT. The parties agree that the Buyers’ sole and exclusive remedy
against Seller shall be for the repair and replacement of defective parts. The
Buyer agrees that no other remedy (including, but not limited to, incidental
or consequential damages for lost sales, lost profits, injury to person or
property) shall be available to him.
14
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>