marson MT6228E Fixed Mount Scanner User Guide
- September 9, 2024
- MARSON
Table of Contents
marson MT6228E Fixed Mount Scanner
Specifications
- Performance:
- Sensor: 1080 x 1280 (1.3M)
- FOV 1D 2D: UPC A, UPC E, EAN 8, EAN 13, Code 128, Code 39, Code 93, Code 32, Code11, Codabar, Plessey, MSI, Interleaved 2 of 5, IATA 2 of 5, Hong Kong 2 of 5, USPS Intelligent Mail, Pharmacode, RSS-14, RSS-14 Expanded, RSS-14 Limited, Composite Code-A, Composite Code-B, Composite Code-C
- Supported Codes: PDF 417, Micro PDF 417, Data Matrix, QR, Micro QR, Aztec, MaxiCode
- Interface: RS232, Ethernet (TCP Client/TCP Server/Modbus TCP)
- Power Supply: 12-24 VDC
- Max. Power Consumption: 11W @12VDC
- Physical Characteristics:
- Size (mm)
- Material: Aluminum Alloy
- Sealing: IP64
- Reliability:
- Storage Temp: -30~+70
- Working Temp: 0~+50
Product Usage Instructions
Installation
The following diagram shows the installation of the scanner.
Auto-tuning
- Press and hold the Tune Button for about 5 seconds until 2 beeps.
- Aim at the desired barcode. Release the Tune Button to start Auto-tuning. The scanner will beep continuously in the process.
- LED status indicates Auto-tuning result (Error or Good). If the result is Good, the settings will be stored permanently even after a power cycle. If the result is an Error, press the Tune Button once again for re-tuning.
Troubleshooting
If the scanner does not work properly:
- Check if the cable is connected firmly and is supplied by the original manufacturer.
- Check if the symbology (barcode type) is enabled.
- Check if the barcode quality is good.
- If the scanner still does not work properly, please contact your local distributor.
FAQ
-
Q: How do I know if the Auto-tuning was successful?
A: The LED status will indicate the Auto-tuning result. If it shows “Good,” the settings will be stored permanently. If it shows “Error,” you can re-tune by pressing the Tune Button again. -
Q: What should I do if the scanner is not working properly?
A: First, check the cable connection and ensure it is from the original manufacturer. Then check if the barcode type is enabled and if the barcode quality is good. If issues persist, contact your local distributor for assistance.
Out of Box
Introduction
1 | Good Read LED |
---|---|
2 | Tuning Mode LED |
3 | No Read LED |
4 | Power LED |
5 | Tuning Button/Scan Button |
6 | Mechanical Knob For Lens Focus (HD to LR Focus) |
I/O Cable
Pin
| Signal|
Function
---|---|---
Red| VIN (+)| 12-24 VDC
(11 W @12V)
Black| GND (-)
Purple| TX ( Scanner) /| RX (Host)| | RS232
Purple & White| RX (Scanner) /| TX(Host)|
Gray| Opto Isolated Output| GOOD READ
Brown| Opto Isolated Output| NG
White| Opto Isolated Input| Trigger
Installation
The following diagram shows the installation of the scanner.
Input Signal
PNP Input Signal
NPN Input
Output Signals
Specification
Specification Chart
Performance
Sensor| 1080 x 1280 (1.3M)
FOV| Horizontal 29° (H), Vertical 34° (V)
1D
| UPC A, UPC E, EAN 8, EAN 13, Code 128, Code 39, Code 93, Code 32,
Code11, Codabar, Plessey, MSI, Interleaved 2 of 5, IATA 2 of 5, Hong Kong 2 of 5, USPS Intelligent Mail, Pharmacode, RSS-14, RSS-14 Expanded, RSS-14 Limited, Composite Code-A, Composite Code-B, Composite Code-C
2D| PDF 417, Micro PDF 417, Data Matrix, QR, Micro QR, Aztec, MaxiCode
Motion Tolerance
| Continuous Scan Mode : 1 m/s Pulse Trigger Mode : 2 m/s
Interface
Supported Host Interfaces|
RS232, Ethernet (TCP Client/TCP Server/Modbus TCP)
Input| 1 Optoisolated input (NPN/PNP/Relay)
Output| 2 Optoisolated output (Good/NG)
Power Supply| 12-24 VDC
Max. power consumption| 11W @12VDC
Physical Characteristics
Size (mm)| 44 (W) × 53 (D) ×29 (H)
Material| Aluminum Alloy
Sealing| IP64
Reliability
Storage Temp| -30℃~+70℃
Working Temp| 0℃~+50℃
Regulatory| TBA
Depth of Field
Lens Focus
| HHD|
LR
---|---|---
Resolution| 1D : ≥3 mil ; 2D : ≥7 mil| 1D : ≥3 mil ; 2D: ≥7 mil
DOF
| Code 39 (5 mil) : 50 mm ~ 120 mm
Data Matrix (7 mil) : 40 mm ~ 120 mm QR (7 mil) : 40 mm ~ 110 mm
| Code 39 (5 mil): 120 mm ~ 320 mm
EAN 13 (13 mil): 70 mm ~ 550 mm
QR (10 mil): 170 mm ~ 220 mm
Field of View
Distance (mm)
| Horizontal (mm)|
Vertical (mm)
---|---|---
100| 53| 61
150| 79| 91
200| 106| 122
300| 158| 182
Dimension
Dimension (mm)
Auto-tuning
- Press and hold the Tune Button for about 5 seconds until 2 beeps.
- Aim at the desired barcode. Release the Tune Button to start Auto-tuning. The scanner will beep continuously in the process.
- LED status indicates Auto-tuning result (Error or Good). If the result is Good, the settings will be stored permanently even after a power cycle. If the result is Error, press the Tune Button once again for re-tuning.
Troubleshooting
If the scanner does not work properly, please do the following first:
- Check if the cable is connected firmly and is supplied by the original manufacturer.
- Check if the symbology (barcode type) is enabled.
- Check if the barcode quality is good.
If the scanner still does not work properly, please contact your local distributor.