ECOLAB SP-10N-MOBYSPRAY Gallon Air Operated Portable Spray Equipment User Manual

June 13, 2024
ECOLAB

ECOLAB SP-10N-MOBYSPRAY Gallon Air Operated Portable Spray Equipment

ECOLAB SP-10N-MOBYSPRAY Gallon Air Operated Portable Spray Equipment User
Manual

READ ALL INSTRUCTIONS BEFORE OPERATING EQUIPMENT

WARNING

Symbols

Read this manual completely and understand the machine before operating or servicing it.

  • Read all instructions before installing or operating unit.
  • Always wear appropriate personal protective equipment (PPE) when operating or servicing unit.
  • Always follow all chemical safety precautions and handling instructions provided by the chemical manufacturer and Safety Data Sheet (SDS).
  • Never point the discharge trigger gun at yourself, another person, or any object you do not want covered in chemical.
  • Always depressurize unit after use (as described in the After Use Instructions), and store unit depressurized.
  • Do not exceed an incoming air pressure of 100 psi (7 bar).
  • Do not exceed a fluid temperature of 100˚F (37˚C).
  • Only use clean and dry air. Air must be filtered and free of moisture or pump life will be diminished. If needed, install an air dryer before unit.
  • Do not use an air lubricator before the unit.

PROTECT THE ENVIRONMENT

Please dispose of packaging materials, old machine components, and hazardous fluids in an environmentally safe way according to local waste disposal regulations.

 Always remember to recycle.

*Specifications and parts are subject to change without notice.

Specifications

Hose ………….. 30 feet reinforced hose, 3/8 inch inside diameter (9 meters reinforced hose, 9.5 mm inside diameter)
Tank Capacity…………………………………….12.5 gallons (47.3 liters)
Spray Output………………….. 2 gallons/minute (7.5 liters/minute)
Spray Output Distance………………… 10 to 12 feet (3 to 4 meters)
Liquid Temperature …………………… 40˚F to 100˚F (4.4˚C to 37˚C)

Dimensions

Length ………………………………… 18 in (457 mm) approximately
Width …………………………………. 14 in (356 mm) approximately
Height ………………………………… 42 in (1067 mm) approximately Weight, including discharge hose and wand:
(Empty) ………………………….. 40 lbs (18 kg) approximately

Requirements

Compressed Air Source Requirements: Air regulator (R25) is factory set at 50 psi (3.4 bar). Operating range is 40 to 80 PSI (3 to 5 bar) with 2 CFM (56.6 l/min).

Chemical Requirements: Follow all instructions from chemical manufacturer and Material Safety Data Sheet (MSDS).

Air Operated Double Diaphragm Pump Models Offered

P56: Polypropylene body with Santoprene diaphragm
P56V : Polypropylene body with Viton diaphragm
P56K : Polypropylene body with Kalrez diaphragm

Acceptable Products:

Chemical products used with this equipment must be formulated for this type of application and compatible with unit materials and pump seals. For more information on chemical compatibility, consult the manufacturer or SDS for your product.
DO NOT USE: All hydrocarbons

Operation Instructions

Wearing all PPE and observing all safety precautions dictated by the MSDS for your chemical:

  1. Fill the tank with the solution to be sprayed.
  2. Connect an appropriate compressed air line into the air inlet fitting (AP25).
  3. Squeeze the discharge trigger gun (PSG12) to begin spraying.

After Use Instructions

  1. Flush the unit with fresh water for 5 minutes.
  2. Disconnect the air line from the air fitting (AP25) and relieve any pressure remaining in the system by squeezing the discharge trigger gun (PSG12).
  3. Release the discharge trigger gun (PSG12) after all pressure has been relieved from the system.

Maintenance Instructions

To keep your portable unit operating properly, periodically perform the following maintenance procedures:

  • Check the air pump (P56/P56K/P56V) for wear and leaks.
  • Inspect hoses for leaks or excessive wear. Make sure all hose clamps are in good condition and properly secured.
  • Replace filter (AFR25) in regulator (R25) as needed.
  • Check the suction tube and screen for debris and clean as needed.
  • Drain compressor tank on a regular basis to ensure proper operation of pump.

Troubleshooting Instructions

  • Check to ensure that the discharge hose is uncoiled properly, and that there are no kinks that could obstruct fluid flow.
  • Check the air regulator bowl (ABR25) and air filter (AFR25) for debris such as water, oil, or rust particles. Clean by unthreading the air regulator bowl (ABR25) from the air regulator (R25).
  • Check the strainer (STR38-IL) for debris or other blockages, and clean as needed. Replace strainer if damaged. Strainer must be used.
  • If air passes through the pump (P56/P56K/P56V) without cycling, the pump needs to be replaced.
  • Check for proper air pressure on the air gauge (AG100). The air regulator (R25) is factory set at 50 psi (3.4 bar). Operating range is 40 to 80 PSI (3 to 5 bar) with 2 CFM (56.6 l/min).
  • If the unit operates at a reduced pressure:
  • Check the air compressor supplying the unit. If the pressure is less than 40 psi, turn the unit off until the compressor can catch up.
  • If the air supply is 50 psi (3.4 bar) or above, check the air gauge (AG100), which should read near 50 psi (3.4 bar). If the air gauge reads more or less than 50 psi (3.4 bar), adjust the pressure by turning the knob on the top of the air regulator (R25).

TANK ASSEMBLY **

**

ITEM NUMBER: TANK-10N-A

Tank Assembly

SPRAY GUN ASSEMBLY

ITEM NUMBER: SGA14

Spray Gun Assembly

DISCHARGE HOSE ASSEMBLY

ITEM NUMBER: H38-30

Discharge Hose Assembly

BACK PLATE

Inside View

Back Plate

BACK PLATE

Outside View

BACK PLATE

OPTIONAL COMPONENTS

WATER SEPARATOR

ITEM NUMBER: WS-20CFM

AIR HOSE ASSEMB LY

ITEM NUMBER: AH30

ITEM NUMBER DESCRIPTION
AG100 1.5 INCH DRY MODEL 20 DUAL SCALE GAUGE
AH30 30 ft Air Hose w/ Quick Connect Fittings
AP25 PLUG 1/4 NPTM AIR FITTING – BRASS
AS1-VS 1/4-20 X 1/2 PHIL TRUSS MACH SCREW 19-8 W/516 ORANGE VIBRASEAL PATCH
B8X58 8-15 X 5/8 inch PHIL FLAT TY-A 316 S.S.
BPS-58SO Back Panel Screw – 5/8 inch with Stand Off
BPS-SSR 1/4 INCH PUSHNUT BOLT RETAINER STAINLESS STEEL
COT 1/8 X 1 COTTER PIN 18-8 S/S
DFP7 7 INCH HINGED CAP ASSEMBLY – INCLUDES BLACK CAP, LID FLANGE AND HINGE

PIN
DFP7-C| 7 INCH FILL CAP POLYPRO BLACK
DFP7-F| 7 INCH TANK LID FLANGE POLYPRO
DFP7-PIN| HINGE PIN FOR DFP7-C & DFP7-C
DFP7-C-BL| 7 INCH FILL CAP POLYPRO BLUE PANTONE
DFP7-C-GN| 7 INCH FILL CAP POLYPRO GREEN PANTONE
DFP7-C-RD| 7 INCH FILL CAP POLYPRO RED PANTONE
DFP7-C-YL| 7 INCH FILL CAP POLYPRO YELLOW PANTONE
DP-A| DRAIN PLUG ASSEMBLY FOR TANK-10N TANK-20N
DP| FRONT DRAIN PLUG FOR PORTABLE UNIT POLYPRO
DP-G| FKM SQUARE CUT DRAIN PLUG GASKET
DP-INSERT| 304 STAINLESS DRAIN PLUG INSERT
EC12| OETIKER CLAMP 21.0-706R
EC14-2| OETIKER CLAMP 13.8
F38SS| STAINLESS 3/8 INCH FERRULE
FWAX15| FLAT AXLE WASHER
FWP12| 7/8 ID X 1.5 OD X 0.05 THK SSFW
H14B-H| 1/4 INCH BLUE HOSE- Available per ft
H38B-H| 3/8 inch BLUE HOSE – Available per ft
HBSS1238| STAINLESS HOSE BARB 1/2mpt X 3/8 barb Tariff 8479.90.9496
HBSSEL1438| STAINLESS HOSE BARB ELBOW 1/4 INCH NPT X 3/8 HOSE BARB
HBSSEL1814| 304 STAINLESS ELBOW 1/8 INCH NPT X 1/4 INCH HOSE BARB
HHPB3414| HEX HEAD POLY REDUCER BUSHING 3/4 X 1/4
P14| COUNTERSUNK PLUG-HEXAGON 1/4
P56| 5700 PUMP WITH SANTOPRENE SEALS – INCLUDES HOSE BARBS, AIR FITTING, AND AIR PORT
P56K| 5700 PUMP WITH KALREZ SEALS – INCLUDES HOSE BARBS, AIR FITTING, AND AIR PORT
P56V| 5700 PUMP WITH VITON SEALS – INCLUDES HOSE BARBS, AIR FITTING, AND AIR PORT
20756103B| Polypro G57 Air Port x HB Straight, w/ Viton O-ring
HB14P| 1/4in BRASS HB AIR FITTING /G57/P56
HB5638| HOSE BARB FOR P56 PUMP
HB5638K| HOSE BARB FOR P56K PUMP
HB5638V| HOSE BARB FOR P56V PUMP
P56-BRKT| PUMP BRACKET- STAINLESS STEEL
P56-BRKT-SCREW| HI LO SCREW FOR RETAINING P56-BRKT
PLPF| PORTABLE FOAMER BACK PLATE W/ HINGE AND HOLES
PLPF-PIN| 302 STAINLESS PORTABLE PLATE HINGE PIN
PLUG 3/4| TUBING PLUG 3/4 ( FITS 11/16 HOLE)
PSG12| Assembly with o-rings included/1/2in POLY SPRAY GUN W/ GRAY HNDL. & 316SS
PSGORV| PSG12 VITON O RING
PVCV34FM| PVC VALVE 3/4in FPT X 3/4in MPT
PW124-120| 1/2in BLACK POLY PRO X 4in – SCH.120 – 1/2in MPTOE & 1/4in FPTOE
R25| AIR REGULATOR – SILVER COLOR – 1/4fpt TWO PORT 1/8fpt TWO PORT – INCLUDES FILTER AND BOWL
AFR25| AIR FILTER for R25
ABR25| METAL AIR BOWL for R25
S142058-VS| 1/4-20 X 5/8 PHIL TRUSS MACHINE SCREW 18-8 W/#516 VIBRASEAL ORANGE PATCH
SC1212| S.S. COUPLER 1/2in BY 1/2in
SSA14| SS304 MALE/FEMALE ADAPTOR 1/4 NPT X 1/4 NPT
SSAXLE14| 14 ½” long with the 5/8” diameter bar & 2 through holes with countersinks beveled ends
SSC38| WORM GEAR CLAMP, S/S (.25-.63)
SSP12| STAINLESS STEEL AXLE PLATE – 2.5 inch X 1 inch – 2 HOLE
ST2520| VEEJET NOZZLE – BRASS 2520
STR38-IL| IN LINE STRAINER 3/8 BARB 20 MESH 304 STAINLESS EDPM GSKT
TANK-10N| 10 GALLON NATURAL TANK
TW916| 1/2 INT TOOTH L/W 410SS
W15| NONMARKING WHEEL FOR PORTABLE UNITS
WS-20CFM| TSUNAMI WATER SEPARATOR 20 CFM

Customer Support

Ecolab Austria
Erdbergstrasse 29
1030 Wien
Telephone: 43 1 715 25 50
Fax: 43 1 715 25 50 2850

Ecolab Denmark
Carl Jacobsens Vej 29-37
2500 Valby
Telephone: 45 36 15 85 85
Fax: 45 36 15 84 48

Ecolab Germany
Ecolab Deutschland GmbH
Ecolab-Allee 1
40789 Monheim am Rhein
Telephone: 49 2 173 599 0

Ecolab United Kingdom
David Murray John Building
Swindon, Wiltshire
SN1 1NH
Telephone: 44 1793 51 12 21
Fax: 44 1793 61 85 52

http://www.ecolab.com/

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>