SKYLUX VITRIA Flat roof window Instruction Manual

September 8, 2024
SKYLUX

SKYLUX VITRIA Flat roof window

General product description

The new Vitria glass flat roof window is made up of clear double glazing and features an optimised glass composition. The Vitria consists of a sleek white PVC frame with excellent insulation characteristics and sealing closures that attach to the curb below. These ensure good air and water tightness. The Vitria flat roof window features a ‘flush-design’ / ‘flat drainage surface’, where the glass panel seamlessly transitions and extends slightly above the PVC frame. This allows for efficient and smooth drainage of rainwater. The Vitria is suitable for flat roofs and can be installed at an inclination between a minimum of 4° to 25°. To prevent contamination of the outside of the glass, we recommend an inclination of 5°. The manually openable version also allows for fresh air ventilation: The manual spindle with eye is a copper spindle that reaches an opening of 300 mm when fully extended. It makes the flat Vitria window suited for manual opening for fresh air ventilation. For smaller sizes, the spindle with eye is a single spindle. For larger sizes, it is a double spindle. The double spindle is always equipped with a link rod. The spindle is pre-mounted and is delivered with matching hinges, top and bottom supports. The system opens and closes manually by means of a optional winding rod.

Variants available:

  • There is also an openable version of the Vitria flat roof window with an electric chain actuator for ventilation.
  • Standard installation of the fixed Vitria flat roof window on PVC curbs or PVC adapter frame; including set of spring steel clips
  • For installation of fixed Vitria flat roof window on polyester or metal curbs; including a special hinge set.

Features

  • openable version for fresh air ventilation; opens up to ± 30 cm

  • with pre-mounted single manual spindle

  • daylight size = light transmission surface

  • ‘flush design’ (the glass panel is higher than the PVC frame and connects seamlessly) for a sleek look and optimal rainwater drainage

  • double glazing, with optimised glass composition

  • good insulation value Ut* = Ug = 1.1 W/m²K

  • frame: extruded white PVC profile with good thermal properties

  • compatible: fits on various curbs

  • high air and water tightness

  • acoustic values: Rw = 39 dB (-1,-5)

  • plenty of dimensions in stock with fast delivery time

  • Ut = Ut = U value of the translucent part (= glass), determined in accordance with EN 1873:2014+A1:2016.

Specific characteristics: Skylux® PVC frame

  • Mechanical properties……………………………………………….. Impact-resistant frame quality PVC type Benvic S white
  • Density in accordance with ISO 1183………………. 1450 kg/m³
  • Fire class in accordance with EN 13501-1………E

Specific characteristics: Skylux® glass

  • Mechanical properties ………………………… HR++ double glazing
  • Type …………………………………………………………………………….. laminated (inner pane) + tempered (outer pane)
  • Thickness……………………………………………………………………. ± 32 mm
  • Weight ……………………………………………………………………….. ± 36 kg/m²
  • Light transmission according to EN 410 ….. clear 77%
  • Solar factor g (ZTA) according to EN 410……. 0,59
  • Sound insulation Rw according to EN 717-1 ….. 39 (-1,-5) dB
  • Ug value according to EN 673 ……………………….. 1,1 W/m²K
  • Safety glass NBN EN 356 ………………………………… min. type P2A (44.2) or type P4A(44.4) for larger sizes

Specific characteristics: assembled unit

  • Impact resistance in accordance with
  • EN 1873:2014+A1:2016 ……………………………………….. SB 1200*
  • Airtightness in accordance with
  • EN 1873:2014+A1:2016………………………………………………. Ap

The Vitria meets the highest impact resistance class, but is not suitable as walkable glass.

Specific characteristics: opening system: manual spindle with eye

Dimensions:

  • Length………………………………………………………………………………….220 mm
  • Diameter……………………………………………………………………………Ø 25 mm
  • Net weight…………………………………………………………………………..500 g/ spindle
  • Opening height………………………………………………………………..± 300 mm
  • Mounting sheets……………………………………………………………..white RAL 9010

Available daylight sizes

Note: Depending on the dimensions and corresponding weight of the glass flat roof window, we recommend using hoisting and/or lifting equipment, both during transport and installation.

Maintenance : It is essential to regularly clean the exterior of the flat glass panel to prevent the build-up of dirt and standing water. After all, even when installed at a minimum inclination of 4°, flat glass always bends slightly (up to 5 mm at 20°C).

To prevent heat buildup beneath the transparent window (whether plastic, hybrid or glass) and thus potential deformation or damage to the PVC curb, frame, skylight or electrical parts, we advise against the installation of a sealed surface (e.g. closed black loft hatch) beneath the roof windows. We recommend using a reflecting (e.g. white) surface and/or ventilation.

Technical drawings

  • on Skylux PVC curb:

Certificates
In accordance with performances of EN 1873:2014+A1:2016, but no CE, as there is no specific standard for glass flat roof windows.

SKYLUX NV
SPINNERIJSTRAAT 100 – B-8530 STASEGEM
T +32 (0)56 20 00 00
INFO@SKYLUX.BE
WWW.SKYLUX.EU

Documents / Resources

| SKYLUX VITRIA Flat roof window [pdf] Instruction Manual
VITRIA Flat Roof Window, VITRIA, Flat Roof Window, Roof Window, Window
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals