Specifications:

  • Shock range
  • Light intensity range
  • Resolution ratio
  • Button
  • Led light
  • Display screen
  • Location mode
  • Memory point
  • Shadow data
  • Interrecord gap
  • Upload interval
  • Data upload method
  • Mode of starting freight
  • Freight stop mode
  • Repeat the start
  • Airplane mode
  • Alarm mode
  • Battery type
  • OTA upgrade
  • Classification of waterproof
  • Work environment
  • Storage environment
  • Specification and dimension

Product Usage Instructions:

Add Equipment:

Log on to the platform website: http://new.i-elitech.com or scan
the code to download and install the APP. Register, sign in, and
add devices as prompted.

Activation:

Long press the button for 5 seconds, and when the screen appears
normally, it indicates that the device is activated.

Airplane Mode:

Open: Long press the button for 5 seconds until
the screen displays a logo indicating the flight mode is
activated.

Close: Long press the button for 5 seconds
until the screen displays a sign indicating that the flight mode is
closed.

Start the Record:

Press the button for 5 seconds, and when the screen sign
indicates the startup record, it means the recording has started.
If the sign is flashing, it’s in delay countdown state before
recording starts automatically.

Stop Recording:

Long press the button for 5 seconds to stop the recording.

Data Export:

Connect the device to a computer via USB interface using a data
cable. The device will automatically generate data reports in PDF +
CSV format. Copy the report to your computer for saving.

FAQ:

Q: How can I export data from the device?

A: Connect the device to a computer using a data cable and the
device will automatically generate data reports in PDF + CSV
format.

Q: How do I activate Airplane Mode?

A: To activate Airplane Mode, long press the button for 5
seconds until the screen displays a logo indicating that Airplane
Mode is activated.

“`

User Manual
Glog 5 Disposable iot logger

Product presentation
Elitech single use loT data logger Glog 5 integrates multiple factors monitoring including temperature.humidity, light, shock, and 4G networking, to provide you with a comprehensive environmental datasolution, The device is equipped with world famous high-precision sensors, can collect and monitortemperature and humidity data in various environments, Rapid start can be set throueh phvsical button.platforms, or timer, to ensure the
humidity data loggers, but also innovates and upgrades onfunctions, providing you with a comprehensive and convenient environment data monitoring solution.
æ

ç

è

î

é

ê

í

ë

ì

æBackmounted hanging hole éStart-st op button ìPower supply + data interface îActivation / Flight mode button

ç Liquid crystal display êSerial number íBuilt-in sensor

èLED pilot lamp ëLight sensor

ç èé ê æ ë
í ì

æOperative mode çFunction declaration èAirplane mode éSignal condition

êBattery capacity ëLight and vibration alarm signs

ìTime and the number of record notes

íTemperature and humidity value

Note: To ensure the reliability of the data, when the battery power is less than 10% to 20%, please donot openthe record (20%)

Technical parameter

Shock range Light intensity range Resolution ratio Button Led light Display screen Location mode Memory point Shadow data Interrecord gap Upload interval Data upload method Mode of starting freight Freight stop mode Repeat the start Airplane mode Alarm mode Battery type OTA upgrade Classification of waterproof Work environment Storage environment Specification and dimension

0g~16g 0~52000Lux 0.1°C/0.1%RH/0.1g/1Lux Double button design Red and green, red and blue LED indicator lights Broken code display LBS + GPS (optional) 32000 Prestant +Afterstop 1min~24h; default: 5min 5min~24h; default: 60min 4G+2G Button pressing, platform, and timing Button, platform, and fill up
Key button, timing, electronic fence Overlimit, low power 3.0V disposable lithium manganese battery 4800 mAh Upgrade is available through the data management software and the platform IP65 (built-in) -30°C ~70°C, 0% RH ~ 100% RH (no condensation) 15~30°C20~75%RH 103 x 61.3 x 30 (mm)

Technical parameter
1.Add equipment Log on to the platform website: http://new.i-elitech.com, or scan the code to download and install the APP Register, sign in, and add devices as prompted.

2.Activation Long press the button for 5 seconds, and the
screen appears normally, indicating that the device is activated.
Note: Click the button screen to display normally, indicating that the device is activated;

3.Airplane mode
Open: long press the button for 5 seconds, the screen is successfully started;

display logo indicates that the flight mode

Close: long press the button for 5 seconds, the screen

sign indicates that the flight mode is closed;

Note: For other flight modes, please operate through the platform or APP.

4.Start the record Press the button for 5 seconds and the screen
signindicates the startup record; if the sign is flashing, the delay countdown state is entered. After the delay, the record starts automatically;
5.Stop recording Long press the button for 5 seconds, the
screen display µsign instructions to stop recording successfully;

6.Data export
The device is connected to the computer USB interface through the data cable, and automatically generates data reports in PDF + CSV format. You can copy the generated report to your computer for saving.

Report generation

Device is connected to the computer

Operating instructions for freight management
1. After logging in to the platform or APP, click the ‘Freight Management’ menu of the main menu; 2. Click the “Configure” menu on the home page to create and add “user management”, “Carrier”, “location”, “alarm preset” and “freight template” successively; 3. Click the “Freight Management” menu on the home page to create and manage the freight transport;
Note: For detailed operation manual, see the operation instructions in the platform or APP;

The LED indicator light has the instructions

Device Statu s/ Operation Malfunction/Low Battery (below 5%) No Calibration No Activation No Start Start Recording Delayed/ Scheduled S ta rt
R ecording
Stop Recording
R ecordingSt opped
Report Generating USB Connecting Clear Report Label Communication Normal Communication Error Start Airplane Mode Stop AirplaneMode Clear the report logo

LED Indicator Display No Flashing Green & R ed Flashing x 2 R ed & R ed Flashing x 2 Green & R ed Flashing x 1 Green Flashing x 5 Green to Red Flashing x 1 Green Flashing x 1(OK) Red Flashing x 1(Alarming) Red Flashing x 5 Green Flashing x 2 (OK) Red Flashing x 2 (Alarming) Green to Red Flashing x 1 Green & R ed On Green & R ed Flashing Blue Flashing x 3 Red & Blue Flashing x 3 Blue Flashing x 5 Blue Flashing x 5 At the same time flashing

Triggering Method Short Press But ton Short Press But ton Short Press But ton Short Press But ton Short Press But ton x 5s
Short Press But ton x 10s or Auto Flashing
Long Press Right But ton x 5s
Short Press But ton
/ Connect USB Long Press Left But ton x 5s Flashing When Connectingto Network Flashing When Connectingto Network Long Press Left But ton x 5s Long Press Left But ton x 5s Long Press Left Button x 5s (USB connected)

LCD explicit declaration
Number of points recorded Low power
Data not uploaded, probe fault

Number of points not uploaded The number of uses has been used
Data not uploaded, probe fault

Safety Instructions
To ensure installing and using the productcorrectly, please read carefully and abide by thefollowing instructions:
Batte r y æPlease use the original battery rather than any other ones, to avoid possible damage or errorto device. çDo not disassemble battery without permission. No squeezing, hittin g, heating or burning the battery, otherwise battery may explode and lead to a fire.
Device æThis device is prohibitedto be used in environments with flammable orexplosive gas, otherwise, an explosion/fire may be caused. ç contact manufacturer or supplier.
Precautions
° If the device will not be in usefor a long period of time, the device should beremoved and stored in the package box in a dry and cool environment.
° even damage the device.
° Do not use the device outdoors, to avoid short circuit, burn, and other malfunctions caused by bad weather such as raining and thunder-lightings.
° networking status.
° Use the data logger within its measurement range. ° Do not impact the data logger withforce. °
³ Temperature deviation: Stabilizing time too short for placing the device in the measurement environment. Near or even exposedto a heat/cold source.
³ Humidity deviation: Stabilizing time too short for placing the device in the measurement environment. Long time exposed in steam, fog, waterfall or condensation environment.
³ Pollution: Exposedto dust or other polluted environment.
V 1.2

FCC Warning
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonableprotection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: – Reorient or relocate the receiving antenna. – Increase the separation between the equipment and receiver. – Connect the equipment into an outlet on a circuit di erent from that to which the receiver is connected. – Consult the dealer or an experienced radio/TV technician for help.
FCC RF exposure statement: